THE WALL-MOUNT 6-TON AIR CONDITIONERS

Similar documents
GREEN REFRIGERANT R-410A

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

GREEN REFRIGERANT R-410A

WALL-MOUNT HEAT PUMPS - (60HZ)

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features

GREEN REFRIGERANT R-410A

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Q-TEC QC-Series Chilled Water Air Conditioner

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models

Q-Tec TM QC-Series Chilled Water Air Conditioner

Q-TEC Q24A-Q60A Air Conditioners

THE WALL-MOUNT TM QUIET CLIMATE HEAT PUMPS

THE WALL-MOUNT HEAT PUMPS EER, (60HZ)

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

GREEN REFRIGERANT R-410A

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps

Q/Tec TM QA-Series Air Conditioners

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

Installation Instructions

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

Q/Tec TM QW-Series Water-to-Air Heat Pumps

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

INSTALLATION INSTRUCTIONS

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

1.5 to 3 Ton 208V to 460V 60hz Air Conditioner Specifications

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS W18H1 W24H1 W30H1 W36H1 W42H1 W48H1 W60H1

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR

REPLACEMENT PARTS MANUAL

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

I-TEC I30A1D-I60A1D 2-Stage Compressor High Efficiency Air Source Air Conditioners w/dehumidification

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH421 WH483 WH602

Product Guide. Wallmount. Air Conditioners & Heat Pumps

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc.

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

SKYPAK II, 3 Ton Series, gives you a

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

INSTALLATION INSTRUCTIONS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

50TM COMBINATION HEATING/COOLING UNITS

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

48PGD/E/F/L/M/N PG20-28

PAJ3. Product Specifications

50TM TFF COMBINATION HEATING/COOLING UNITS

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Commercial High-Efficiency Condensing Units

Product Data. Fig. 1 - Unit 50VR -A

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

62DA,DB,DC,DD,DE,DF07-38

General Description. Operation

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

REPLACEMENT PARTS MANUAL

General Description. Safety Listed

General Description. Safety Listed

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS

RGE 13 A T - 1 A

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

Transcription:

THE WLL-MOUNT -TON IR CONDITIONERS Model W7 - Right Side Control Panel Model W7L - Left Side Control Panel, Btuh 9.5 EER Hz The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities. Factory or field installed accessories are available to meet specific job requirements. Engineered Features GREEN REFRIGERNT R-4 luminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. Twin Blowers: Move air quietly. Most models feature multispeed blower motors providing airflow adjustment for high and low static operation. Motor overload protection is standard on all models. ir Conditioner Compressor: Scroll Compressors eliminate need for crankcase heater. R-4 Refrigerant: Designed with R-4 (HFC) nonozone depleting refrigerant in compliance with the Montreal protocol and EP requirements. Phase Rotation Monitor: Standard on all 3 phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Galvanized Gauge Zinc Coated Steel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand hours of salt spray tests per STM B7-3. Foil Faced Insulation: Standard on all units. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Components: re easily accessible for routine inspection and maintenance through a left side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or toggle disconnect switch. Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory installed for all ½ through 5 ton models. Filter Service Door: Separate service door provides easy access for filter change. One Inch, Disposable ir Filters: re standard equipment. Optional one inch washable filters available and filter racks permit the addition of " pleated filter. Factory or field installed. Condenser Fan and Motor Shroud ssembly: Slides out for easy access. Barometric Fresh ir Damper: Standard on all units. llows up to 5% outside fresh air. Optional ventilation packages available. Built-in Circuit Breakers: Standard on all electric heat versions of single (3/ volt) and three phase (3/ volt) equipment. Toggle disconnects are standard on all electric heat versions of three phase (4 volt) equipment. Slope Top: Standard feature for water run-off. Top Rain Flashing: Standard feature on all models. ME # 357-93-E Liquid Line Filter Drier: Standard on all units. Protects system against moisture. Compressor Control Module: Standard on all units. Built-in off-delay timer adjustable from 3 seconds to 5 minutes. -minute on-delay if power interrupt. -second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. larm output for alarm relay. High & Low Pressure Switches are uto-reset: Standard on all units. Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Complies with efficiency requirements of NSI/SHRE/IESN 9.-7. Certified to NSI/RI Standard 39-3 for SPVU (Single Package Vertical Units). Intertek ETL Listed to Standard for Safety Heating and Equipment NSI/UL 995/CS. No. 3-5, Third Edition. Commercial Product - Not intended for Residential application. Form No. S349-5 Supersedes S349-9 Page of

Capacity and Efficiency Ratings Models Volts Operating Voltage Range Compressor Type Phase Cap. BTUH CFM / ESP ( Rated Wet Coil) EER W7-, W7L- 3/ 97-53 SCROLL,, /. 9. 5 W7-B, W7L-B 3/ 97-53 SCROLL 3,, /. 9. 5 W7-C, W7L-C 4 44-5 SCROLL 3,, /. 9. 5 Capacity is certified in accordance with NSI/RI Standard 39-3. EER = Energy Efficiency Ratio and is certified in accordance with NSI/RI Standard 39-3. ll ratings based on fresh air intake being % closed (no outside air introduction). Specifications Models Rating HZ RL Compressor BCSC LR HP / RPM / SPD Outdoor Fan Motor Indoor Blower Motor Filter Size Inches) Std Shipping IMPORTNT While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires in accordance with the National Code and all existing local codes. FL DI / CFM HP / RPM / SPD F L. ( Weight W7-, W7L- 3/-.9 / 3 3 45 / / / -Spd 4. 4" / 3,5 / /,7 / -Spd. 3. 3 x 3 x 5 W7-B, W7L-B 3/-3 3 /.. / / / -Spd 4. 4" / 3,5 / /,7 / -Spd 3. 3 x 3 x 5 W7-C, W7L-C 4-3 4. 4. 7 3/4 / / -Spd. 7 4" / 3,5 / /,7 / -Spd. 9 x 3 x 5 Specifications MODELS Maximum size of the time delay fuse or HCR type circuit breaker for protection of field wiring conductors. Based on C copper wire. ll wiring must conform to the National Code (NEC) and all local codes. 3 These Minimum Circuit mpacity values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest revision), article 3 for power conductor sizing. Caution: When more than one field power conductor circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding mpacity djustment Factors when more than 3 conductors are in a raceway. Electric Heat Table----Refer to Specifications for vailability by Unit Model Heater Packages - Field Installed (W7 Only) Form No. S349-5 Supersedes S349-9 Page of Rated Volts & Phase W7-, Z / W7L-, Z W7-5 / W7L-5 W7- / W7L- 3/- W7-5 / W7L-5 W7- W7-B, BZ / W7L-B, BZ W7-B9 / W7L-B9 3/-3 W7-B5 / W7L-B5 W7-B W7-C, CZ / W7L-C, CZ W7-C9 / W7L-C9 4-3 W7-C5 / W7L-C5 Nominal KW 5. 9.. 5... No. 3 Field Minimum Power Circuit Circuits mpacity or or 49 49 59 5 43 43 53 3 3 7 SINGLE CIRCUIT Maximum External Fuse or Circuit Breaker 9 5 5 5 3 3 35 Field Power Wire Size 4 Ground Wire Size 3 Minimum Circuit mpacity 59 59 B 5 DUL CIRCUIT Maximum External Fuse or Circuit Breaker B Field Power Wire Size B Ground Wire Size B Indoor Blower Performance CFM at 3 Volts 3 43 3 t 4V () t V () t 4V () t 4V () Kw -Ph 3-Ph Btuh 5.. 7, 9.. 7,77. 4. 7 4,3 5.. 5 3.,95. 43. 3,434. 3. 3, 5 3 5 3 5 5 () These electric heaters are available in 3/V units only. () These electric heaters are available in 4V units only. Kw -Ph 3-Ph Btuh 3.7.,799.7. 7 3,3 7.5 3. 5,59. 54. 3.,39 3.5 37. 5 4,7 5. 7. 5,95 -Designed for adding Electric Heat to KW Units -Circuit Breaker Standard on 3/V Models -Pull Disconnect Standard on 4V Models -UL Listed -CUL Listed - Models -B Models -C Models ir Conditioner 3/- 3/-3 4-3 Models Heater Model # K W Heater Model # K W Heater Model # KW EHW-5 5 EHW7-B9 9 EHW5-C9 9 W7 EHW5- EHW5-B5 5 EHW5-C5 5 EHW5-5 5 EHW7-B EHW5- Field installed heater package not available for W7L models. Kw 3-Ph Btuh Kw 3-Ph Btuh 9.. 3,77.. 4, 3 5.. 5,95 3. 7. 3 47,99 W7 / W7L E.S.P. HIGH SPEED LOW SPEED In H O DRY / WET COIL DRY / WET COIL., /,, /,45., /,9,55 /,3., /, /.3, /,7 /.4,7 /, /.5, /,4 /

learances Required for Service ccess nd dequate Condenser irflow MODELS LEFT SIDE RIGHT SIDE W 7 / W7L " " Minimum Clearances Required to Combustible Materials MODELS W 7 / W7L " SUPPLY IR DUCT FIRST THREE FEET CBINET /4 " Dimensions of Basic Unit for rchitectural and Installation Requirements (Nominal) 4..5 Electric Heat Built In Slope Top Pitch.3.44. 43. 43. 9. Heater ccess Panel 9. Side Wall Mounting Brackets (Built In) Supply ir Opening. Circuit Breaker Disconnect ccess Panel (Lockable) 3.. 3.5 Condenser irflow is Blowthrough on ll Models Filter ccess Door Ventilation ir Low Voltage 5. 94.7 4.7 37. 3.5 44.9 4.43 33.7. Return ir Opening... Front View W7 Right Side View W7 Drain Back View W7 Bottom Installation Bracket. MIS-7 43. 43..44 9...3.5 Built In Slope Top Pitch 4.. Supply ir Opening Side Wall Mounting Brackets (Built In) 9. Electric Heat Heater ccess Panel. 3. Circuit Breaker Disconnect ccess Panel (Lockable). Return ir Opening 3.5 94.7 5. Filter ccess Door Ventilation ir 3.5... 44.9 4.43 33.7 37. 4.7 Low Voltage Condenser irflow is Blowthrough on ll Models Bottom Installation Bracket Back View W7L Left Side View W7L Drain Front View W7L MIS-73 Form No. S349-5 Supersedes S349-9 Page 3 of

Ventilation System Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. ll units are equipped with a barometric fresh air damper as the standard ventilation package. ll ventilation packages can be built-in at the factory, or field-installed at a later date. BROMETRIC FRESH IR DMPER - BFD STNDRD The barometric fresh air damper is a standard feature on all models. It is installed on the inside of the service door and allows outside ventilation air, up to 5% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The damper opens during blower operation and closes when the blower is off. djustable blade stops allow different amounts of outside air to be introduced into the building and can be easily locked closed if required. Barometric Fresh ir Damper BLNK OFF PLTE - BOP blank off plate is installed on the inside of the service door. It covers the air inlet openings, which restricts any outside air from entering the unit. The blank off plate should be utilized in applications where outside air is not required to be mixed with the conditioned air. MOTORIZED FRESH IR DMPER - MFD The motorized fresh air damper is internally mounted behind the service door and allows outside ventilation air, up to 5% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The two position damper can be fully opened or closed. The damper blade is powered open by a 4VC motor with spring return on power loss. The damper can be controlled by indoor blower operation or can be field connected to be managed based on building occupancy. Motorized Fresh ir Damper NOTE: The above vent systems are intake only without built-in exhaust capability. Building will likely require separate field installed barometric relief or mechanical exhaust elsewhere within the conditioned space. Balancing dampers in the return air grille may be required to achieve specified amount of outdoor air intake. COMMERCIL ROOM VENTILTOR - CRV The built-in commercial room ventilator is internally mounted behind the service door and allows outside ventilation air, up to 5% of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper. Commercial Room Ventilator The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field controlled based on room occupancy. Two versions are available: the CRVS is power open - spring return on power loss; the CRVP is power open and power return. Complies with NSI/SHRE Standard. Ventilation for cceptable Indoor ir Quality. ECONOMIZER - EIFM The built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. Economizer Energy Recovery Ventilator Standard Features: One Piece Construction - Easy to install with no mechanical linkage adjustment required. Exhaust ir Damper - Built in with positive closed position. Provides exhaust air capability to prevent pressurization of tight buildings. ctuator Motor - 4 volt, power open, spring return with built in torque limiting switch. Proportioning Type Control - for maximum free cooling economy and comfort. Moisture Eliminator & Prefilter - permanent, washable aluminum construction. Enthalpy Control - adjustable to monitor outdoor temperature and humidity. Minimum Position Potentiometer - adjustable to control minimum damper blade position for ventilation purposes. Mixed ir Sensor - to monitor outside and return air to automatically modulate damper position. WLL-MOUNT ENERGY RECOVERY VENTILTOR - ERVF The wall-mount energy recovery ventilator is a highly innovative approach to meeting indoor air quality ventilation requirements as established by NSI/SHRE Standard.. The ERVF allows from to 45 CFM (depending upon model) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases, this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 7% during summer and % during winter conditions. The ERVF consists of a unique rotary energy recovery cassette that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed - including limiting ventilation during building occupancy only. The ERVF is designed to be internally mounted behind the service door in the W7 or W7L model wall mount units. It can be built-in at the factory or field installed as an option. ERVF-*5C can be independently adjusted for intake and exhaust rates. Form No. S349-5 Supersedes S349-9 Page 4 of Manufactured under U.S. Patent Nos. 5,45,7; 5,3,744; 5,,.

Commercial Room Ventilator Performance Data - CRVS-5 and CRVP-5 W7, W7L HIGH SPEED TOTL ND VENTILTION IRFLOW irflow (cfm) 9 7 5 4 3 9 7 5 4 3 B C D E F Vent Position Total ir ESP Total ir. ESP Total ir.4 ESP Vent ir ESP Vent ir. ESP Vent ir.4 ESP irflow (cfm) 5 4 3 9 7 5 4 3 W7, W7L LOW SPEED TOTL ND VENTILTION IRFLOW B C D E F Vent Position Total ir ESP Total ir. ESP Total ir.4 ESP Vent ir ESP Vent ir. ESP Vent ir.4 ESP Form No. S349-5 Supersedes S349-9 Page 5 of

Performance and pplication Data- ERVF-*5C mbient O.D. DB/ WB F VLT 4 5 45 95 9 5 VENTILTION RTE 45 % EFFICIENCY CFM SUMMER COOLING PERFORMNCE (INDOOR DESIGN CONDITIONS DB/ WB) VENTILTION RTE 3 % EFFICIENCY CFM VENTILTION RTE 3 7% EFFICIENCY VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL 45 4 395 9477 44 77 5 5737 5 37 43 97 459 957 3 7 45 9477 9477 5 5 97 97 45 45 9477 9477 5 5 97 97 359 5 944 533 797 35 35 5 7374 9 9 4 547 3 4 5 934 395 797 4 77 5 77 5 53 43 957 547 4 7 35 5 9 797 3 93 5 793 35 35 557 547 9 5 5 797 797 5 5 547 547 5 5 797 797 5 5 547 547 359 97 7 533 3 45 35 5 7374 4 45 4 434 97 4 97 744 395 3 734 77 977 5 459 43 4 73 957 434 54 7 35 97 3 9 3 7 93 93 793 447 35 4 5 557 434 97 97 3 3 4 4 434 434 97 97 3 3 4 4 434 434 359 79 43 533 473 5794 35 5 7374 49 33 4 4 35 54 4 79 4 395 473 93 77 5 49 779 43 4 945 957 35 33 7 35 79 5 9 473 39 93 4 793 49 74 35 4 33 557 35 79 79 473 473 49 49 4 4 35 35 79 79 473 473 49 49 4 4 35 35 359 4 73 533 359 7374 35 45 7374 7 47 34 7 4 7 939 4 4 395 359 793 77 45 337 5 7 93 43 34 7 957 7 74 7 35 4 749 9 359 47 93 45 43 793 7 4 35 34 4995 557 7 334 4 4 359 359 45 45 7 7 34 34 7 7 4 4 359 359 45 45 7 7 34 34 7 7 4 43 935 395 579 37 77 5 5 5 33 49 43 9 957 5 5 7 35 43 99 9 579 449 93 5 793 33 5457 35 557 5 443 45 43 74 579 4 3543 5 5 33 33 35 5 99 5 4 43 43 579 579 5 5 33 33 5 5 7 35 35 9 9 93 93 793 793 35 35 557 557 45 45 74 74 3543 3543 33 33 35 35 99 99 CFM ERVF-*5C WINTER HETING PERFORMNCE (INDOOR DESIGN CONDITIONS 7 F DB) VENTILTION RTE mbient 45 CFM 3 CFM 3 CFM O.D. % EFF. % EFF. % EFF. DB/ F WVL WHR WVL WHR WVL WHR 43 944 5 4 3 4 3 45 3 34 55 79 53 49 4 395 5 97 777 4 533 45 5 97 5 4 4 45 4 5 94 97 797 35 7 3 4 4 34 99 3 944 555 3 9 7 5 7 749 5 47 45 955 43 944 5 4 34 5 73 34 4 7 4 NOTE: Sensible performance only is shown for winter application. LEGEND: VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent WVL= Winter Ventilation Load WHR = Winter Heat Recovery Form No. S349-5 Supersedes S349-9 Page of

pplication Data Outdoor Temperature F Model W7 W7L D.B./W.B. / / 7 5/ 7 Capacity Total Sensible Total Sensible Total Sensible Below F, unit requires a factory or field installed low ambient control. Return air temp. F. F F 5 F 9 F 95 F F 5 F F 5 F F 5 F 74, 53, 79, 5,4 94,3 5, 7, 5,4 7,3 5,4 9, 5,, 49,9 73,5 49,4 4,4 49,, 4,3 7, 4,3 79,9 4, 59, 4,7, 47,,5 4, 5, 45,,4 45,9 7,5 44,4 53, 43,,7 44,7 7, 4, 5,5 4,, 43,4 4, 4,7 47,9 4,5 57, 4,,5 3, 45,5 3,9 55, 4,7 57,3 3, 43,3 37,3 5,7 39,3 54, 34, Capacity Multiplier Factors % of Rated irflow - Rated + Total BTUH Sensible BTUH.9.95....5 Form No. S349-5 Supersedes S349-9 Page 7 of

ir Conditioning Wall-Mount Model Nomenclature W 7 X X X X X X SERIES NOMINL CPCITY 7 - Ton TYPE = Compressor & Controls - Right Side L = Compressor & Controls - Left Side Note: For KW and circuit breakers (3/ Volt) or toggle disconnects (4 Volt) applications, insert Z in the KW field of the model number. Ventilation Models W7, W7L Description Factory Installed Field Installed Code No. Part No. Barometric Fresh ir Damper - Standard X BFD-5 Blank-Off Plate B BOP-5 Motorized Fresh ir Damper M MFD-5 Commercial Ventilator - Spring Return w/exhaust V CRVS-5 Economizer - Fully Modulating E EIFM-5 C Economizer - Fully Modulating D N/ Energy Recovery Ventilator - 3 Volt R ERVF-5 3 Energy Recovery Ventilator - 4 Volt R ERVF-C5 3 Door Kit for ERVF (Required) N/ WMDK5- Low ambient control is required with economizer for low temperature compressor operation. For use only with V Control Module and TCS3 Controller. 3 Intake and exhaust can be independently adjusted. WMDK Door Kit must be ordered in addition to ERVF ssembly and color matched to unit ("X" = Beige; "4" = Buckeye Gray; "" = Dark Bronze) ir Conditioning Control Modules HPC LPC CCM 3 LC 4 LR 5 SK SK 7 ODT DDC 9 Factory Installed Code REVISION VOLTS & PHSE - 3/// B - 3///3 C - 4//3 KW VENTILTION OPTIONS (See Table Below) FILTER OPTIONS X - -inch Throwaway (Standard) W - -inch Washable P - -inch Pleated COLOR OPTIONS X - Beige (Standard) - White 4 - Buckeye Gray 5 - Desert Brown - Dark Bronze - luminum S - Stainless Steel W7, W7L Field Installed Part X N/ E CM- J Factory Only K CMC-5 and CM- M Factory Only N, WL Only ield Installed Only ield Installed Only CONTROL MODULES (See Chart Below) COIL OPTIONS X - Standard - Phenolic Coated Evaporator - Phenolic Coated Condenser 3 - Phenolic Coated Evaporator and Condenser OUTLET OPTIONS X - Front (Standard) N/ CMC- CM- F 5 F 4 V Factory Only Field Installed Only CM-4 Field Installed Only SK7 = Standard equipment for these specified models. HPC. High pressure control is auto reset. lways used with compressor control module (CCM) which is included. See note 3. LPC. Low pressure control is auto reset. lways used with compressor control module (CCM) which is included. See note 3. 3 CCM. Compressor control module has adjustable 3-second to 5-minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be - minutes plus % of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with retry) for high and/or low-pressure controls, and a -minute timed bypass for low-pressure control. 4 LC. Low ambient control permits cooling operation down to F 5 LR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls. SK. PTCR start kit can be used with all - single phase models. Increases starting torque -3x. Not used for -B or -C three phase models. Do not use if SK7 is used. 7 SK. Start capacitor and potential relay start kit can be used with all - single phase models. Increases starting torque 9x. Not used for -B or -C three phase models. Do not use if CMC-5 is used. ODT. Outdoor thermostat is adjustable from to 5 F. It is suitable for use as a compressor cut-off thermostat. 9 DDC. Incorporates 4 additional sensors: discharge air temperature, indoor blower airflow, compressor current, and dirty filter. These sensing devices function to input analog data such as temperature, as well as digital data such as airflow, compressor status or filter status. V control module should be ordered in conjunction with direct digital controller (DDC) model TCS3. Refer to DDC specification sheet S3 for more information. Form No. S349-5 Supersedes S349-9 Page of Bard Manufacturing Company, Inc. Bryan, Ohio 435 www.bardhvac.com Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. S349 May, Supersedes S349-9