HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Similar documents
Distributors for Floor Heating Systems

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

CALIS-TS-3-D. HERZ Armaturen. Standard Sheet for 7745, 7746, 7761 Edition 0700 (0999) Three-Way Valves in 3-D Design for One-Pipe Systems

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

TS RD 7761 RD, 7761 RD

HERZ Regulating valve 4002

HERZ Differential Pressure Control Valve 4002

Mikrotherm. Manual Radiator Valves With presetting

Say heating. Say Herz. HERZ-Supply Engineering

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Thermostatic valves with radiator connection systems

Control valves for floor heating systems. Floor Heating Manifolds

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Regulux. Radiator lockshield with drain-off facility. To be precise.

Multilux 4-Eclipse-Set

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Valid from

Thermostatic valve bodies

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Flush individual room control for floor heating systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Thermostatic valve bodies

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Problem-solvers The Radiator Solution Range

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Thermostatic shower valve with 2 way diverter, brass faceplate and handles - V51

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Art-Line. Absolutely Brilliant Temperature control was never so good

MINIATURE THERMOSTATIC VALVE

Thermostatic Valve and Trim

INDIVIDUAL HEATING. Installation Manual e Skirting Heating Classic. Skirting Heating Delta. HEATING. COOLING. COMFORT.

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

RA15/6T & TB Conversion Valve

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION

INSTALLTION FOR THERMOSTATIC VALVES

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

INSTALLATION INSTRUCTIONS

Aquatique. Shower heads. Fixed and adjustable height heads. Aquatique shower kits installation guide page 1

Owner s Guide and Installation Manual

Installation and operating instructions. DK energy storage and DK energy buffer

General System Layout Sketch

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

RA 2000 Series RA 15/6T & TB Conversion Valve

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems

Thermostatic head with wax sensor

Tuzio Milano Towel Warmer

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Safety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

INSTALLATION INSTRUCTIONS

For more information on Pegler Yorkshire visit Heating Controls. Radiator valves with new integral push-fit inlet

INSTALLATION INSTRUCTIONS

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

SOLUTIONS GUIDE. For total efficiency

Thermostatic shower valve with 3 way control, brass faceplate and handles - V52

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

2 DESCRIPTION OF SYSTEM COMPONENTS

Heating Controls Thermostatic and Manual Radiator Valve range

Wave. BATH SHOWER MIXER MONOBLOC With Kit Deck Mounted

Owner s Guide and Installation Manual

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Automatic balancing valves ASV-PV (new generation) DN 32-50

Radiator Valve Program

installation and operation manual for Hunter Ceiling Fans

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

Thermostatic mixing valves with interchangeable cartridges

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Thermostatic Bar Valves

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

INSTALLATION FOR THERMOSTATIC VALVES

Standard. thermostatic valve body without presetting

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

FOR INSTALLING AND USING

INSTALLATION INSTRUCTIONS

Temperature Sensor TRG Original Installation Instructions English

Installation S

STRAIGHT AND ANGLED THERMOSTATIC VALVES

INSTALLATION INSTRUCTIONS

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

thermostatic valve body with stepless precision presetting

SOLUTIONS GUIDE. For total efficiency

Transcription:

HERZ-Thermostatic and Return Valves Standard Sheet for DE LUXE Edition 1000 (0999) This series consists of HERZ radiator thermostats, HERZ-TS-90 thermostatic valves and HERZ return valves. These components all have a special smooth coating. A separate standard sheet is available for HERZ thermostatic heads DE LUXE. Valve Series 7923 7924 Thermostatic Valves H = Dimension HERZ thermostat R = 1/2" H T =26,5+H H T =26,5+H 7958 7959 7928 7923 7924 Thermostatic Valves with Compression Union H = Dimension HERZ thermostat R = 1/2" Ø = 10 16 H T =26,5+H H T =26,5+H 7958 7959 7928 Return Valves R = 1/2" 3725 3726 3725 Return Valves with Compression Union R = 1/2" Ø = 10 16 3726 Compression Union 6292 6284 We reserve the right to make modifications necessitated by technological progress. HERZ Armaturen Richard-Strauss-Straße 22 A-1230 Wien

Explanations Radiator connection with cone seal, special socket for threaded pipe and compression union, R = 1/2", with screw cap. Compression union 6292 for pipe external diameter 15 mm with cover sleeve to be ordered separately. Radiator connection with cone seal R = 1/2", pipe connection with male thread M 22 x 1.5 for compression union, with crew cap and compression union cover. Compression union 6284 for pipe external diameters 10 16 mm to be ordered separately. Colours Straight valve Angle model Reverse angle model Valve to the left of radiator Valve to the right of radiator Chrome 1 7923 41 1 7924 41 1 7928 41 1 7958 41 1 7959 41 Anthracite (ruthenium plated) 1 7923 42 1 7924 42 1 7928 42 1 7958 42 1 7959 42 Gold 1 7923 43 1 7924 43 1 7928 43 1 7958 43 1 7959 43 White (RAL 9010) 1 7923 44 1 7924 44 1 7928 44 1 7958 44 1 7959 44 Black matt 1 7923 49 1 7924 49 1 7928 49 1 7958 49 1 7959 49 Colours Straight valve Angle model Reverse angle model Valve to the left of radiator Valve to the right of radiator chrome 1 7923 51 1 7924 51 1 7928 51 1 7958 51 1 7959 51 Anthracite (ruthenium plated) 1 7923 52 1 7924 52 1 7928 52 1 7958 52 1 7959 52 gold 1 7923 53 1 7924 53 1 7928 53 1 7958 53 1 7959 53 White (RAL 9010) 1 7923 54 1 7924 54 1 7928 54 1 7958 54 1 7959 54 Black matt 1 7923 59 1 7924 59 1 7928 59 1 7958 59 1 7959 59 Radiator connection with cone seal, special socket for threaded pipe and compression union, R = 1/2", with screw cap. Compression union 6292 for pipe external diameter 15 mm with cover to be ordered separately. Radiator connection with cone seal R = 1/2", pipe connection with male thread M 22 x 1.5 for compression union, with crew cap and compression union cover. Compression union 6284 for pipe external diameters 10 16 mm to be ordered separately. Colours Straight valve Angle model Straight valve Angle model Chrome 1 3725 41 1 3726 41 1 3725 51 1 3726 51 Anthracite (ruthenium plated) 1 3725 42 1 3726 42 1 3725 52 1 3726 52 Gold 1 3725 43 1 3726 43 1 3725 53 1 3726 53 White (RAL 9010) 1 3725 44 1 3726 44 1 3725 54 1 3726 54 Black matt 1 3725 49 1 3726 49 1 3725 59 1 3726 59 For universal models Compression union cover (coloured), locking nut (male thread) and olive for pipe external diameter 15 mm. For models with compression union Locking nut (female thread) and olive for pipe external diameters 10, 12, 14, 15 and 16 mm. The coloured compression union cover is supplied with the valve. Colours For pipe external diameter. Chrome 1 6292 41 10 mm 1 6284 00 Anthracite (ruthenium plated) 1 6292 42 12 mm 1 6284 01 Gold 1 6292 43 14 mm 1 6284 03 White (RAL 9010) 1 6292 44 15 mm 1 6284 04 Black matt 1 6292 49 16 mm 1 6284 05 Special colours, colour combinations and other metallic coatings can be supplied upon request. HERZ-TS-90 Thermostatic Valves HERZ Return Valves Compression Union Special Colours 2

HERZ-Thermostat- und Rücklaufventile DE LUXE Max. operating temperature 90 C Max. operating pressure 10 bar Hot water purity in conformity with ÖNORM H 5195 or VDI-guideline 2035 When using HERZ compression unions for copper and steel pipes, observe the permissible temperatures and pressures as specified in EN 1254-2:1998 Table 5. Operating Data Compression Union Water heating systems. Field of Application Iron pipe connection with cover cap and cover sleeve, with cone seal, installed. Spare part order number: 1 6210 44, without cap and cover sleeve. Radiator Connection HERZ universal models are equipped with special sockets. They are suitable for connecting either a threaded pipe R = 1/2" or a calibrated soft-steel or copper pipe with an external diameter of 15 mm. The compression union 6292 must be ordered separately. During installation, replace the socket cover ring of the valve with the compression union cover. The compression union cover (two parts) is snapped on after installation of the compression union. Compression Union Connections Valves with connections for compression unions are fitted with a male thread M 22 x 1.5 on the pipe side and have been prepared for the installation of compression union 6284. The compression union cover (two parts) is snapped on after installation of the compression union. We recommend use of support sleeves for the installation of soft steel or copper pipes with compression unions. For perfect installation, it is imperative to lubricate the thread of the locking nut (male thread and female thread) as well as the olive itself with silicon oil. We refer to our instructions for installation. Valves with Compression Union Connections 1. Unlock the nut cover ring by shortly turning anti-clockwise. Subsequently, pull it back and slacken the nut. 2. Install the connection with cover sleeve and nut cover ring by means of a 10 mm Allen key. 3. Unlock the socket sleeve by shortly turning anti-clockwise and remove it. Install the valve onto the threaded pipe and align. Slide the sleeve onto the valve and lock it by shortly turning clockwise. 4. Connect the valve and the nut and fasten by means of a 27 mm key. Slide the cover ring onto the nut and lock it by shortly turning clockwise. Valve Installation HERZ-TS-90 HERZ Return Valve O-ring set 1 6890 00 1 6810 90 Accessories HERZ changing tool 1 7780 00 1 7780 00 For changing the O-ring and/or For changing the thermostat upper part the O-ring Keys 1 6807 90 1 6807 90 For changing the O-ring and/or For changing the thermostat upper part the O-ring Valve upper part 1 6390 91 Radiator connection without 1 6210 44 1 6210 44 cover cap and cover sleeve Spare Parts Compression union cover for models with compression union connection Chrome 1 6280 51 Anthracite (ruthenium plated) 1 6280 52 Gold 1 6280 53 white (RAL 9010) 1 6280 54 Black matt 1 6280 59 3

HERZ-TS-90-Thermostatic Valve Changing the Thermostatic Upper Part The thermostatic upper part can be removed and/or changing by means of the HERZ-changing tool while the system is under pressure: retrofitting the valve with a thermostatic valve upper part with fixed, stepped kv-value or with an upper part with pre-setting function. This permits regulation of the radiator flow rate to individual requirements; in order to clean the spindle seat seal and/or change the thermostatic upper part. This permits easy removal of defects in thermostatic radiator valves, caused, e.g., by foreign substances such as dirt, welding or soldering residues. Follow the operating instructions supplied with the HERZ-changing tool. Special Design Features HERZ-Changing Tool An O-ring is used as a spindle seal. It is located in a brass chamber which can be changed during operation. The O-ring keeps maintenance requirements at a minimum and permits lasting ease of valve operation. Changing the O-Ring Chamber 1. Remove the HERZ-thermostatic head. 2. Unscrew the O-ring chamber with the O-ring and replace with a new one. During this change use a wrench to hold the upper part. After removal of the thermostatic head the valve is completely open and therefore sealed tight towards upstream. However, a few drops of water may leak out. 3. For re-assembly follow the above steps in reverse sequence. Order number of O-ring set: 1 6890 00 Spindle Seal HERZ-TS-90 O-Ring Chamber The screw cap serves for operation during the installation phase (pipe flushing). The thermostatic valve is formed by removing the screw cap and screwing in the thermostatic head without draining the heating system. Setting the nominal lift with the screw cap: On the knurled part of the circumference of the screw cap there are two setting marks (webs) in alignment with the + and marks. 1. Close the valve by turning the screw cap clockwise. 2. Mark the position corresponding to the setting mark +. 3. Turn the screw cap anti-clockwise until the setting mark is at the position marked under item 2. HERZ-Thermostatic Valve Nominal Lift The thermostatic valve is installed in the radiator intake in such a way that the flow comes from the socket side, or the compression union side. Wherever possible, the thermostatic head should be in a horizontal position in order to guarantee optimum room temperature control with minimum interference. Installation 4

HERZ Return Valves The return valve permits shut off on the radiator return connection. When both, the intake and return valves are shut off (thermostatic head in position 0 ) the radiator can be removed while the system is under pressure without having to close off the rest of the system. The return valve permits exact control of the water flow rate through the radiator in accordance with the desired heat output, as well as hydraulic balancing of the system. Field of Application After removing the cover plate, the valve spindle is screwed in completely by turning it clockwise with a screwdriver. Any pre-setting steps must be set again after opening the valve. Shutting off the Radiator 1. Unscrew cover plate. 2. Screw the valve spindle in completely with a screwdriver. After doing so, the valve is shut. 3. Unscrew the valve spindle by means of a screwdriver in accordance with the value to be set (according to diagram); e.g. for pre-setting step 3 make 3 anti-clockwise turns. 4. Re-install cover plate. The valve spindle is secured against unintended unscrewing. Pre-Setting An O-ring is used as a spindle seal. It is located in a brass chamber which can be changed during operation. The O-ring keeps maintenance requirements at a minimum and permits lasting ease of valve operation. The O-ring chamber is changed by means of the HERZ changing tool. For detailed instructions consult the operating instructions supplied with the HERZ changing tool, item HERZ-DE-T-90-Changing the O-Ring. Spindle Seal Changing the O-Ring Chamber The seat seal is metallic and therefore wear.resistant. Seat Seal The valve is protected against unauthorized operation by a plastic screw cap. Anti-Tamper Security Pre-setting step = Return Valve 3725 Return Valve 3726 turns Straight Version Angle Version 0.25 0.12 0.12 0.5 0.3 0.3 0.75 0.5 0.5 1 0.65 0.65 1.25 0.9 0.9 1.5 1.1 1.15 1.75 1.35 1.5 2 1.55 1.75 2.5 1.9 2.2 3 2.1 2.5 open 2.3 2.8 kv-value Table Return Valves 5

HERZ-Standard Diagram HERZ-TS-90 Art. No. 7923 7924 Dim. DN 15 R=1/2" Valve dimensioning [ p] has to be performed in accordance with the VDMA-Instruction Sheet for Planning and Hydraulic Balancing of Heating Systems with Thermostatic Radiator Valves ( p max. = 0.2 bar). kv-value Pressure drop p Standard flow rate qm We reserve the right to make modifications. HERZ Armaturen Richard-Strauss-Straße 22 A-1230 Wien 6

HERZ-Standard Diagram HERZ-Return Valves Art. No. 3725 Dim. DN 15 R=1/2" Die Ventilauslegung [ p] ist entsprechend dem VDMA-Merkblatt über Planung und hydraulischen Abgleich von Heizungsanlagen mit thermostatischen Heizkörperventilen vorzunehmen. kv-value Pressure drop p Standard flow rate qm We reserve the right to make modifications. HERZ Armaturen Richard-Strauss-Straße 22 A-1230 Wien 7

HERZ-Standard Diagram HERZ-Return Valves Art. No. 3726 Dim. DN 15 R=1/2" kv-value Pressure drop p Standard flow rate qm We reserve the right to make modifications. HERZ Armaturen Richard-Strauss-Straße 22 A-1230 Wien