Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

Similar documents
Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW

Remote Air Cooled Condensers C2 Series

Ducted Split System Air Conditioners Technical Data

Ducted Split System Air Conditioners Technical Data

Packaged Air Conditioning Custom Build Solutions

EC Motor Fan Coil Units. IMD-Y Series l/s

EC Motor Fan Coil Units. IMDL-Y Series l/s

Condensing Units CUS 15-60

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control

Evaporators 60HZ version

Kirby CO 2 Evaporators

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Helios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

LOW PROFILE EVAPORATORS

Kirby Commander Condensing Unit

HEATING & COOLING COIL PRODUCTS

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

Pool heating, efficiently

Transformer oil coolers BETA & CETA

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

GLIDER EVO GLIDER EVO. rcgroupairconditioning

Water Cooled Air Conditioners Applications Manual

SCA 620C AIR COOLED SCREW CHILLER

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

Goedhart VNS. Air coolers for agricultural applications Cu/Al R404A - CO 2. engineering for a better world. GEA Heat Exchangers

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material

Engineered efficiency - no matter where or what. KMe Coolers Fresh ideas from Searle. GEA Searle

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

High Heat COP. High/Low Stage

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

KELVIN Clim F497. Kelvin air conditioning

Evaporator E4 Series. Innovative Refrigeration Solutions. Floor Mounted Blast Chiller/Freezer F - Series

OPA RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control

Concealed Ducted Split Series R-407C MBH

EC Motor Fan Coil Units. IMDL-Y Series l/s

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

AIR COOLED CONDENSERS

Cooling Capacity 1.0kW - 8.5kW. Heating Capacity 1.0kW - 9.7kW. Hitachi. Inverter Wall Splits Air Conditioning. Giving you complete control

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. eco. series. Air Conditioning. Giving you complete control

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

Air Cooled Packaged Units

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

Heat Pumps for Swimming Pools extend the season or swim year round

PRODUCT RANGE: ROOFTOP PACKAGE

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

CENTRAL SPLIT UNIT UNIC

Antarctic-Unit Cooler/Air Cooler

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

500 EX Fusion Compressor Series

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

Modular Air Cooled Scroll Chillers

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Installation Instructions

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

AQUASNAP JUNIOR 30RHV

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

DIGIHEAT IN LINE HEATERS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

VA G 052 S

Transcription:

Modular Air Cooled Condensers Technical Data ACN Series Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 68 kw 155 kw MARCH 2010

ACN SERIES MODULAR AIR COOLED CONDENSERS General The ACN Series of modular air cooled condensers provide condensing liquid for coercial and industrial refrigeration applications. Applications The ACN Series is designed to be used for industrial applications, rack refrigeration, and remote condenser application. The ACN range of air-cooled condensers Total Heat of Rejection () value is based on condensing R404A at 50 C with a 15K temperature difference (TD) between surrounding ambient and condensing temperature of refrigerant). The ACN range is useable with a variety of different refrigerants including: R404A, R22, R134A, R407C, R507 and R410A. Capacities The ACN Series is available in nominal capacities of 68 kw to 155 kw Total Heat of Rejection () over 28 models. Multiple ACN units can be installed where greater capacity is required, or alternatively ask about the larger capacity models available. The capacities specified in this pamphlet relate to a specified range of conditions. Capacities at other conditions could vary considerably. To obtain the optimum unit selection for other conditions, contact your nearest temperzone office. FEATURES Casing. Made from the highest grade galvanised steel construction, powder coated inside and out for maximum moisture protection and utilising rust free stainless steel fasteners throughout. Heat Exchange Element (Coil). Die formed plate type aluminium fins mechanically bonded to high efficiency inner grooved (rifled) copper tube. Tested at 2068 kpa air pressure under water, the coils are suitable for 1600 kpa working pressure. Higher test pressures are available if requested. Coil fins are epoxy coated aluminium fins for added protection in salt laden or polluted atmospheres. Fans. Propeller fans are 630 or 710 diameter with a fixed pitch and five blades. They are individually partioned for maximum airflow and coil thermal performance. Fans are axial flow Ziehl-Abegg from the range FB and FE. The 710 diameter fan is from the FE range and is sickle-shaped diecast aluminium blades. The 630 diameter fan is from the FB range and 4 blade stamped aluminium impeller. Fan motors are asynchronous (AC motors) 100% speed controllable. Fan motor speed high/low delta/star switching may be applied if required, via a change-over switch. The fans assemblies are rated for 60 C maximum ambient temperature. Fan motors are 3 phase 400V +/-10%, 50 Hz and two speed and protected to IP54. Motor terminal boxes are made from impactproof and weather-proof plastic. The motors are protected from overtemperature with bimetal switch embedded in motor winding. Construction: Vertically up air discharge, horizontal tube/ fin heat exchange coil with sheetmetal casing. Coil circuits are free draining to liquid header thus avoiding poor system operation due to transient condensing pressures. Construction facilitates the adjacent placing and bolting together of separate units thus optimizing real-estate space. Electrical terminal box may be optimally positioned to minimze power cable run length. Coil tubesheets are aluminium and only semi-restrained so as to eliminate tube to tubesheet wear resulting from expansion and contraction of tube bundle during normal operation. Standard Equipment 1. Heat transfer coil (epoxy coated). 2. Propeller fans with three phase motors. 3. Fan guards. 4. Copper swage connections. 5. Stainless steel nuts and bolts. ELECTRICAL The electrical supply required (including voltage fluctuation limits) is: 3 phase 360-440 a.c. 50 Hz with neutral and earth.. Fan motors are pre-wired to a coon terminal block in the electrical box. NOMENCLATURE e.g. A C N 1 4 Series A - Air C - Cooled N - Condenser Size Nominal Capacity in kilowatts (Table 1 & 2) LOCATION & INSTALLATION To ensure maximum efficiency of operation, the following points need to be addressed prior to installation: 1. Locate pipework away from the ACN unit so that it is not an obstruction to the unit's air flow and does not provide a heat source to the air entering the coil. 2. Other plant adjacent to the unit must not be so close that it effects the air flow of the unit. 3. Colour of the mounting surface can create high solar gains that adversely affect (raise) the air entering temperature. 4. Adjacent buildings, plant and prevailing winds can cause down drafts, reducing air flow to the coils, thereby causing higher air entering temperatures and loss of performance. 5. Do not locate the unit near a parapet wall. If this can not be avoided then the unit should be raised on extended legs or installed on a plinth. Alternative Models Standard models have been developed to meet the needs of typical coercial applications. Should you have any special requirements, such as larger capacities or horizontal air discharge, contact your nearest temperzone sales office; temperzone engineers have over 35 years experience in designing air conditioning equipment for special applications. Note Materials and specifications subject to change without notice due to the manufacturer's ongoing research and development prograe. The manufacturer operates a quality management system that conforms to AS/NZS ISO 9001:2000. Refrigerant: J - R22 M - R404A N - R134A L - R407C K - R410A O - R507C T 6 D Three phase V Vertical discharge fans D - Delta connection S - Star connection 6-630 dia. fan 7-710 dia. fan

PERFORMANCE DATA Table 1 630 Dia. Fan 4 Pole Motor MODEL Delta Connection =1300RPM Star Connection = 910 RPM Heat of Rejection* Table 3 Correction Factors for Different Refrigerants R404A R22 R134A R407C R507 R410A 1 0.96 0.93 0.87 1 1 Heat of Rejection ACN 90-2 81.9 6050 88 68.2 4580 83 ACN 91-2 92.7 5830 88 72.9 4220 83 ACN 100-3 121.8 8500 90 98.9 6250 84 ACN 125-3 126.5 8250 90 100.3 5950 84 ACN 135-3 132.9 8830 90 109.9 6750 84 ACN 136-3 138.5 8750 90 110.4 6330 84 ACN 145-3 144.0 8600 90 120.0 6660 84 Table 2 710 Dia. Fan 6 Pole Motor *Heat of Rejection rating at 15 C TD MODEL Delta Connection = 900RPM Star Connection = 680 RPM Heat of Rejection* Heat of Rejection ACN 90-2 86.9 6660 80 73.9 5160 74 ACN 91-2 96.8 6160 80 81.7 4890 74 ACN 100-3 125.0 8750 82 104.1 6750 75 ACN 125-3 129.1 8500 82 109.9 6660 75 ACN 135-3 141.0 9580 82 118.9 7540 75 ACN 136-3 146.8 9400 82 122.9 7330 75 ACN 145-3 155.2 9100 82 131.2 7330 75 *Heat of Rejection rating at 15 C TD SELECTION EXAMPLE Required data: Required Total Heat of Rejection () 75 kw Refrigerant R22 Design Dry Bulb Ambient Temperature 35 C Desired Condensing Temperature 45 C Temperature Difference (TD) 10 C 1) Correct for Refrigerant Required Total Heat of Rejection = 75 Correction Factor (Table 3) 0.96 Corrected Total Heat of Rejection = 78.1 kw (A) Table equivalent Total Heat of Rejection = Corrected x Rating TD = 78.1 x 15 C TD Required TD 10 C TD = 117.15 kw i.e. required (B) 2) Identify Options available from Tables 1 & 2 that meet required (B) Option Unit Fan Dia. Motor Conn. Fan Speed 1 ACN135-3 710 680 RPM 118.9 kw 75 2 ACN136-3 710 680 RPM 122.9 kw 75 3 ACN100-3 710 680 RPM 125.0 kw 82 4 ACN145-3 630 910 RPM 120.0 kw 84 5 ACN100-3 630 1300 RPM 121.8 kw 90

3) Calculate Actual Condensing Temperature Actual Condensing Temperature ( C) = 15K TD x Corrected Total Heat of Rejection (A) Selected Table Total Heat of Rejection Option 1 Option 2 Option 3 ACN 135-3, 710 Dia., 680 RPM- ACN 136-3, 710 Dia., 680 RPM- ACN 100-3, 710 Dia., 900 RPM- 15 x 78.1 = 9.8K TD 15 x 78.1 = 9.9K TD 15 x 78.1 = 9.4K TD 118.9 122.9 125.0 add add add Design ambient C d.b. 35.0 Design ambient C d.b. 35.0 Design ambient C d.b. 35.0 Actual Cond. Temp. C 44.8 Actual Cond. Temp. C 44.5 Actual Cond. Temp. C 44.4 Option 4 Option 5 ACN 145-3, 630 Dia., 910 RPM- ACN 100-3, 630 Dia., 1300 RPM- 15 x 78.1 = 9.6K TD 15 x 78.1 = 9.6K TD 120.0 121.8 add add Design ambient C d.b. 35.0 Design ambient C d.b. 35.0 Actual Cond. Temp. C 44.6 Actual Cond. Temp. C 44.6 PHSICAL DATA Table 4 630 Dia. Fan 4 Pole Motor MODEL = 1300 RPM = 910 RPM FAN DETAILS COIL DETAILS CONNECTION PUMP-DOWN OPERATING MASS * No. Fans Total Start Total Run R/Deep FPM Gas Liquid Charge kg -R404a ACN 90-2 81.9 6050 88 68.2 4580 83 2 14 3.96 3 560 42 35 21.43 274 ACN 91-2 92.7 5830 88 72.9 4220 83 2 14 3.96 4 560 42 35 27.98 310 ACN 100-3 121.8 8500 90 98.9 6250 84 3 21 5.94 4 480 54 41 35.49 368 ACN 125-3 126.5 8250 90 100.3 5950 84 3 21 5.94 4 560 54 41 35.49 378 ACN 135-3 132.9 8830 90 109.9 6750 84 3 21 5.94 4 480 54 41 42.03 485 ACN 136-3 138.5 8750 90 110.4 6330 84 3 21 5.94 4 560 54 41 42.03 496 ACN 145-3 147.9 8600 90 121.8 6660 84 3 21 5.94 5 480 54 41 51.86 537 Table 5 710 Dia. Fan 6 Pole Motor kg *Based on 80% full / +35 SCT MODEL = 900RPM = 680RPM FAN DETAILS COIL DETAILS CONNECTION PUMP-DOWN OPERATING MASS * No. Fans Total Start Total Run R/Deep FPM Gas Liquid Charge kg R404a ACN 90-2 86.9 6660 80 73.9 5160 74 2 12.4 3.15 3 560 42 35 21.43 274 ACN 91-2 96.8 6160 80 81.7 4890 74 2 12.4 3.15 4 560 42 35 27.98 310 ACN 100-3 125.0 8750 82 104.1 6750 75 3 18.6 4.73 4 480 54 41 35.49 368 ACN 125-3 129.1 8500 82 109.9 6660 75 3 18.6 4.73 4 560 54 41 35.49 378 ACN 135-3 141.0 9580 82 118.9 7540 75 3 18.6 4.73 4 480 54 41 42.03 485 ACN 136-3 146.8 9400 82 122.9 7330 75 3 18.6 4.73 4 560 54 41 42.03 496 ACN 145-3 155.2 9100 82 131.3 7330 75 3 18.6 4.73 5 480 54 41 51.86 537 kg *Based on 80% full / +35 SCT

DIMENSIONS () Not to Scale PROJECTION ACN 90-2 ACN 91-2 42 INLET 42 INLET (1-5/8") Cu STUB 1160 O/A 994 420 835 35 OUTLET (1-3/8") Cu STUB 2179 MTG CTRS 2286 35 OUTLET 931.5 MTG 1040 ACN 100-3 ACN 125-3 (2-1/8") Cu STUB 1160 O/A 420 994 835 41 OUTLET (1-5/8") Cu STUB 2729 MTG CTRS 2836 41 OUTLET 931.5 MTG 1040 ACN 135-3 ACN 136-3 ACN 145-3 520 (2-1/8") Cu STUB 1160 O/A 994 41 OUTLET (1-5/8") Cu STUB 3279 MTG CTRS 3386 41 OUTLET 931.5 MTG 1040 Note Materials and specifications are subject to change without notice due to the manufacturer's ongoing research and development prograe. Certified dimensions available on request.

Available from temperzone limited Head Office, Auckland : 38 Tidal Rd, Mangere, N.Z. Private Bag 93303, Otahuhu, NEW ZEALAND. Email sales@temperzone.co.nz Website: www.temperzone.biz temperzone australia pty ltd Head Office, Sydney : 7A Bessemer St PO Box 6448, Delivery Centre, Blacktown, NSW 2148, AUSTRALIA. Email sales@temperzone.com.au AUCKLAND SDNE Ph. 0-9-279 5250 Ph. (02) 8822-5700 Fax 0-9-275 5637 Fax (02) 8822-5711 WELLINGTON ADELAIDE Ph. 0-4-569 3262 Ph. (08) 8376-1505 Fax 0-4-566 6249 Fax (08) 8376-1449 CHRISTCHURCH SINGAPORE Ph. 0-3-379 3216 Ph. SNG 6733 4292 Fax 0-3-379 5956 Fax SNG 6235 7180 MELBOURNE Ph. (03) 9551-7422 Fax (03) 9551-8550 BRISBANE Ph. (07) 3399-2544 Fax (07) 3399-2577 NEWCASTLE Ph. (02) 4962-1155 Fax (02) 4961-5101 REGISTERED S U P P L I E R PERTH Ph. (08) 9314-3844 Fax (08) 9314-3855 TOWNSVILLE Ph. (07) 4773-9566 Fax (07) 4773-9166 HOBART Ph. (03) 6272-0066 Fax (03) 6272-0506 03/10 Pamphlet No. 3189a temperzone limited 2010 Manx Press