EMI ENGINEERING SUBMITTAL

Similar documents
EMI ENGINEERING SUBMITTAL

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Specifications and Performance S2H

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

MACH N-407 Heat Pump Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller

R-410A Ductless Split Systems. Single Zone, Dual Zone & Multi Zone Air Conditioners & Heat Pumps. Chilled Water Fan Coils

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

MAC-120HE-03 Air-Cooled Chiller

Fujitsu Condenser Model Number: AOU18RLXFZ, AOU18RLXFZH, AOU24RLXFZ, AOU24RLXFZH, AOU36RLXFZ, AOU36RLXFZ1, AOU48RLXFZ1.

PAJ3. Product Specifications

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Commercial High-Efficiency Condensing Units

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Commercial High-Efficiency Condensing Units

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

R-410A DUCTLESS SPLIT SYSTEMS. Single Zone, Dual Zone & Multi Zone Air Conditioners and Heat Pumps

50TM COMBINATION HEATING/COOLING UNITS

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

NFZP Variable Refrigerant Flow Guide Specification

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

50TM TFF COMBINATION HEATING/COOLING UNITS

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL SPECIFICATIONS

SECTION VARIABLE REFRIGERANT FLOW SYSTEM

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

PACKAGE AIR CONDITIONER

Advance Release September 2009

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

30GT FLOTRONIC AIR-COOLED CHILLERS

SKYPAK II, 3 Ton Series, gives you a

GUIDE SPECIFICATIONS AQUARIUS ii

Incremental Comfort Conditioners

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

R4H4. Product Specifications

Enviromaster International LLC 5780 Success Dr. Rome, NY Nominal Capacities: 30,000-36,000 Btuh

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL SPECIFICATIONS

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

SKYPAK II Heating & Cooling Self Contained Packages

30GN FLOTRONIC II AIR-COOLED CHILLERS

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

48TM GAS HEATING/ELECTRIC COOLING UNITS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

R4H4. Product Specifications

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

WJH4 Product Specifications

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

Specifications and Performance

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

Split System Cooling Product & Performance Data

Split System Heat Pump Product Data

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

N4H4. Product Specifications

Nominal Circuit Capacities: 9,000 12,000 18,000 & 24,000 Btuh units.

48TF GAS HEATING/ ELECTRIC COOLING UNITS

2 shp 13 lc 1 36 t - 1 a

Product Specifications. Vertical Floor Consoles By First Co.

TECHNICAL SPECIFICATIONS

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Transcription:

(MH4) MULTI-ZONE HEAT PUMP AIR CONDITIONING SYSTEM Rev. 1.4 [3/05] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT DESIGNATION: SCHEDULE #: MODEL #: EMI ENGINEERING SUBMITTAL Submittal Data: MULTI-ZONE CAH (ceiling unit) FHP (fl oor unit) MH4 (Multi-Zone Condenser) TBH (T-bar unit) WHP (wall unit) CHP (ceiling unit) STANDARD FEATURES 5 Year Compressor/One Year Parts Warranty Anti-Short cycle Protection (Except TBH) Top Discharge Condenser Fan Purge (Except TBH) Enviromaster International LLC 1 Duratec Performance Package For Compressor Protection (9K-15K) - Suction Accumulator - Filter Drier - Hard Start Assist - Loss Of Charge Switch - Crankcase Heater - Manual Reset High Pressure Switch

PART ONE GENERAL The heat pump air conditioning system shall be an EMI AmericaSeries Multi-Zone split system per the equipment schedule. The system shall consist of two, three or four indoor air handler models per the air handler equipment schedule and matching AmericaSeries Multi-Zone condenser per the condenser equipment schedule. The units shall be made within North America. The systems shall be listed by Intertek Testing Service (ITS) and bear the ETL label (except TBH). All wiring shall be in accordance with the National Electrical Code (N.E.C.). The units shall be rated in accordance with ARI Standard 210/240 and bear the ARI label (except TBH). The units shall be manufactured in a facility certifi ed to ISO 9001, which is an international standard used to provide guidance in the development and implementation of an effective Quality Management System. The condensing unit shall contain an R-22 refrigerant charge for the evaporator sections and condenser circuits. System circuits shall meet or exceed 1992 Federal Standards. PART TWO WARRANTY The units shall have a manufacturer s warranty for a period of one (1) year from date of installation. The compressor shall have a warranty of fi ve (5) years from date of installation. If, during this period, any part should fail to function properly due to defects in workmanship or material, it shall be replaced or repaired at the discretion of Enviromaster International LLC. This warranty does not include labor. Manufacturer shall have fi fteen years experience in the U.S. market. PART THREE PERFORMANCE COOLING Each indoor unit, specifi ed by the air handler equipment schedule, shall provide a total minimum capacity, SEER and EER at ARI standard conditions per the chart below. The system net minimum total cooling capacity and circulating air rate at 80 F (DB)/67 F (WB) entering the indoor coil and 95 F (DB) air entering the outdoor coil for the circuit combination on equipment schedule shall be rated per the chart below. The total power consumption of the combined system listed on the equipment schedule shall not exceed the wattage listed on the chart below. Cooling Performance (MH4) Legend: 9 = 9,000; 2 = 12,000; 5 = 15,000; 08 = 18,000; 04 = 24,000; 03 = 30,000 Cooling Capacities (Btuh) Total Current Indoor Unit Outdoor Unit Power Compressor Fan Amps Zone 1 Zone 2 Zone 3 Zone 4 Total SEER EER (1) Amps (3) Combinations Consumption (W) Amps (2) Unit A Unit B Unit C Unit D Total 230V 9 + 9 + 9 9,400 9,400 9,400 28,200 2,820 10 10 11.4 12.4 9 + 9 + 9 + 9 9,400 9,400 9,400 9,400 37,600 3,760 10 10 15.2 16.2 2 + 2 + 2 11,200 11,200 11,200 33,600 3,360 10 10 14.4 15.4 2 + 2 + 2 + 2 11,200 11,200 11,200 11,200 44,800 4,480 10 10 19.2 1.0 20.2 5 + 5 + 5 14,200 14,200 14,200 42,600 4,260 10 10 19.2 or 21.9 5 + 5 + 5 + 5 14,200 14,200 14,200 14,200 56,800 5,680 10 10 25.6 1.8 28.6 08 + 08 17,100 17,100 34,200 3,420 10 10 14.8 15.8 04 + 04 22,400 22,400 44,800 4,480 10 10 19.2 20.2 03 + 03 28,600 28,600 57,200 5,720 10 10 23.4 25.4 MC2 = 2 Zone up to 15K Btu MC4 = 2 Zone over 18K Btu (1) To obtain EER: When mixing/matching various capacities, add individual circuit capacities to get total system capacity. Example: MC4D9908; 9,400 + 9,400 + 17,100 = 39,900 Btuh Then obtain total wattage by adding individual circuit wattage to get total system wattage. Example: MC4D9908; 940 + 940 + 1710 = 3,590 Watts To obtain EER rating divide total system capacity by total system wattage. Example: MC4D9908; 35,900 / 3,590 = 10 EER (2) Fan Amps: Use 1.0 for all 9K, 12K, 18K and 24K models. Use 1.8 for any unit containing a 15K or 30K circuit. (3) To obtain Total Amps (current) for specifi c model NOT on above chart: Example: MH49908; Compressor Amps + Fan Amps = Total Amps 7.6 + 7.5 + 1.0 = 16.1 Amps http://www.enviromaster.com 2 emi@enviromaster.com

HEATING The system shall provide a heating capacity and COP per chart below at ARI conditions, which is 70 F (DB) entering the indoor coil, and 47 F (DB)/43 F (WB) air entering the outdoor coil. The MH4 unit is limited range heat pump that will operate in heating mode down to 35 F +/- and turn off the compressor. At that time the electric heater in the EMI indoor unit (if option supplied) will operate to meet the heating need. Heating Performance (MH4) Legend: 9 = 9,000; 2 = 12,000; 5 = 15,000; 08 = 18,000; 04 = 24,000; 03 = 30,000 Total Current Indoor Unit Heating Capacities (Btuh) Outdoor Unit Power COP Compressor Fan Amps Amps (3) Combinations Consumption (W) (1) Amps (2) Unit A Unit B Unit C Unit D Total 230V 9 + 9 + 9 8,000 8,000 8,000 24,000 2,268 3.1 11.4 12.4 9 + 9 + 9 + 9 8,000 8,000 8,000 8,000 32,000 3,024 3.1 15.2 16.2 2 + 2 + 2 10,000 10,000 10,000 30,000 2,835 3.1 14.4 15.4 2 + 2 + 2 + 2 10,000 10,000 10,000 10,000 40,000 3,780 3.1 19.2 1.0 20.2 5 + 5 + 5 13,600 13,600 13,600 40,800 3,984 3.0 19.2 OR 21.9 5 + 5 + 5 + 5 13,600 13,600 13,600 13,600 54,400 5,311 3.0 25.6 1.8 28.6 08 + 08 16,000 16,000 32,000 2,929 3.2 15.0 15.8 04 + 04 20,800 20,800 41,600 4,062 3.0 18.4 20.2 03 + 03 26,500 26,500 53,000 5,175 3.0 23.0 25.4 (1) To obtain COP if you have a specific model NOT on this chart: Example: MH4D9908; (Total Btu Total W) 3.414 = COP (8,000 + 8,000 + 16,000) (756 + 756 + 1465) = COP 32,000 2,977 = 10.75 3.414 = 3.1 COP (2) Fan Amps: Use 1.0 for all 9K, 12K, 18K and 24K models. Use 1.8 for any unit containing a 15K or 30K circuit. (3) To obtain Total Amps (current) for specific model NOT on above chart: Example: MH49908; Compressor Amps + Fan Amps = Total Amps 7.6 + 7.5 + 1.0 = 16.1 Amps PART FOUR INDOOR UNIT Each Multi-Zone condenser shall be matched with any of the following Indoor Units. See equipment schedule for corresponding air handler selection: FHP (Floor Series) The indoor unit shall be factory assembled, wired and contain a low voltage transformer. The cabinet shall be fabricated of G60 galvannealed steel, fi nished in off-white with corrosion inhibiting polyester powder-coated paint. The evaporator fans shall be a forward curve centrifugal type, dynamically balanced and directly mounted to the motor(s) shafts. The motor(s) shall be PSC type with internal thermal overload protection. Return air shall be fi ltered by means of an easily removable electrostatic washable fi lter. The indoor unit shall have fresh air capability through the back of the unit. The evaporator coil shall be of nonferrous construction with louvered fi ns bonded to rifl ed copper tubing. The tubing shall have inner grooves for high effi ciency heat exchange. All tube joints shall be brazed with phoscopper or silver alloy. The coil shall be pressure tested at the factory. A condensate pan and drain shall be provided under the coil. System refrigerant fl ow shall be controlled by means of an orifi ce piston in the indoor unit. The unit electrical power shall be 208/230 Volts, 1 phase, 60 Hertz. The system shall be capable of satisfactory operation within voltage limits of 208/230 +/- 10% Volts. WHP (Wall Series) The indoor unit shall be factory assembled, wired and contain a low voltage transformer. The cabinet shall have a white paint fi nish. The evaporator fan shall be an assembly with line fl ow tangential fan direct driven by a single motor. The fan shall be statically and dynamically balanced and run on permanently lubricated bearings. An adjustable vane shall be provided with ability to change the airfl ow vertically. Return air shall be fi ltered by means of an easily removable electrostatic washable fi lter. The evaporator coil shall be of nonferrous construction Enviromaster International LLC 3

with louvered fins bonded to rifled copper tubing. The tubing shall have inner grooves for high efficiency heat exchange. All tube joints shall be brazed with phoscopper or silver alloy. The coil shall be pressure tested at the factory. A condensate pan and drain shall be provided under the coil. System refrigerant fl ow shall be controlled by means of an orifi ce piston in the indoor unit. The unit electrical power shall be 208/230 Volts, 1 phase, 60 Hertz. The system shall be capable of satisfactory operation within voltage limits of 208/230 +/- 10% Volts. CHP (Ceiling Series) The indoor unit shall be factory assembled, wired and contain a low voltage transformer. The cabinet shall be fabricated of G60 galvannealed steel, fi nished in off-white with corrosion inhibiting polyester powder-coated paint. The evaporator fans shall be a forward curve centrifugal type, dynamically balanced and directly mounted to the motor(s) shafts. The motor(s) shall be PSC type with internal thermal overload protection. The supply louvers shall be dual adjustable for airfl ow direction. Return air shall be fi ltered by means of an easily removable electrostatic washable fi lter. The indoor unit shall have fresh air capability through the top and back of the unit. The evaporator coil shall be of nonferrous construction with louvered fi ns bonded to rifl ed copper tubing. The tubing shall have inner grooves for high effi ciency heat exchange. All tube joints shall be brazed with phoscopper or silver alloy. The coil shall be pressure tested at the factory. A condensate pan and drain shall be provided under the coil. System refrigerant fl ow shall be controlled by means of an orifi ce piston in the indoor unit. The unit electrical power shall be 208/230 Volts, 1 phase, 60 Hertz. The system shall be capable of satisfactory operation within voltage limits of 208/230 +/- 10% Volts. CAH (Recessed Ceiling Series) The indoor unit shall be factory assembled, wired and contain a low voltage transformer. The indoor unit shall consist of galvanized steel chassis with fi re-resistant thermal and acoustic foam insulation and pearl grey high-impact polystyrene fascia. This unit shall fi t in the ceiling and have the capability of attaching a branch supply duct as well as a fresh air duct. The evaporator fan(s) shall be backward curved impeller centrifugal design, dynamically and statically balanced, and mounted on integral mounting rails. The evaporator motor(s) shall be multispeed, enclosed type with thermal protection and sealed lifetime bearings. The indoor unit shall have factory installed 1.5KW electric heat on the 9,000 and 12,000 Btuh models, 3KW electric heat on the 15,000,18,000 and 24,000 Btuh models and 5KW electric heat on the 36,000, 42,000 and 48,000 Btuh models. The indoor unit shall be equipped with an orifice piston in the evaporator and shall have 4-way adjustable air supply louvers, on the 9,000 and 12,000 Btuh models, and motorized 4-way adjustable air supply louvers on the 15,000,18,000, 24,000,30,000,36,000, 42,000 and 48,000 Btuh models. Return air shall be fi ltered by means of an easily removable fi lter(s). The evaporator coil shall be of nonferrous construction with louvered fi ns bonded to rifl ed copper tubing. The tubing shall have inner grooves for high effi ciency heat exchange. All tube joints shall be brazed with phoscopper or silver alloy. The coil shall be pressure tested at the factory. A condensate pan and drain shall be provided under the coil. An integral condensate pump capable of lifting 18 inches shall be provided. The unit electrical power shall be 208/230 Volts, 1 phase, 60 Hertz. The system shall be capable of satisfactory operation within voltage limits of 208/230 +/- 10% Volts. TBH (T-Bar Ceiling Series) The indoor unit shall be factory assembled, wired and contain a low voltage transformer. The cabinet shall be fabricated of heavy gauge galvanized steel. The ceiling insert grill shall be a designer white, aluminum, architectural panel with fi xed position intake louvers and fi xed, three way discharge louvers to minimize recirculation. Return grill shall be hinged for quick access to fi lter. The evaporator fan shall be an assembly with direct drive, double width, double inlet, and forward curved centrifugal fan in draw through confi guration. The motor shall be a PSC type, with overload protection and mounted on vibration isolators. Return air shall be fi ltered by means of an easily removable disposable standard 20 x 20 x 1 fi lter. The evaporator coil shall be of nonferrous construction with louvered fi ns bonded to rifl ed copper tubing. The tubing shall have inner grooves for high effi ciency heat exchange. All tube joints shall be brazed with phoscopper or silver alloy. The coil shall be pressure tested at the factory. A condensate pan and drain shall be provided under the coil. System refrigerant fl ow shall be controlled by means of an orifi ce piston in the indoor unit. The unit electrical power shall be 208/230 Volts, 1 phase, 60 Hertz. The system shall be capable of satisfactory operation within voltage limits of 208/230 +/- 10% Volts. http://www.enviromaster.com 4 emi@enviromaster.com

Sound Data (Indoor Models) Model Size dba Size dba Size dba Size dba FHP 09,12 48.6 15 56 18 57.2 24,30 60.6 WHP 09,12 48 15,18 51 24,30 54 N/A N/A CHP 09,12,15 46.3 18 50.8 24,30 56 N/A N/A CAH 09,12 35 15,18,24 41 30 45 N/A N/A TBH 09,12 52.1 18,24 54.1 N/A N/A N/A N/A Model Weight Specifications (Indoor Models) Model Size Weight (Lbs) Size Weight (Lbs) Size Weight (Lbs) FHP 9,12,15 110 18,24,30 120 N/A N/A WHP 09,12 85 15,18,24,30 115 N/A N/A CHP 09,12,15 115 18,24,30 135 N/A N/A CAH 09,12 50 15,18,24 86 30 128 TBH 09,12 160 18,24 165 N/A N/A PART FIVE CONTROL SYSTEM The FHP (floor) and WHP (wall) indoor unit control section shall consist of unit-mounted infrared compatible controls. Interconnect low-voltage Wiring shall run from indoor unit to outdoor unit direct. NO SPLICES. When running low voltage wiring a double insulated, 5-wire 18 gage cable is mandatory or use shielded 5-wire cable. The microprocessor shall be factory wired and located within the indoor unit. It shall have the capability of sensing return air temperature and indoor coil temperature; large ¾ LCD backlit display; operational range adjustable between 55º F and 95º F in one-degree increments; anti-short cycle compressor protection; minimum compressor run time; fan purge, fan remains on for 60 seconds after heat/cool call is dropped for improved effi ciency; freeze protection to prevent evaporator freeze ups; annunciation provides an audio feedback when the control settings are changed; universal control board allows the unit to operate with either a straight cool or heat pump condenser; two stage heating when optional electric heat and heat pump condenser are selected; fan operation of auto (cycling), high and low (constant), auto fan operation automatically selects fan speed according to heating or cooling demand ; dry mode operates cooling and electric heat simultaneously to remove humidity, optional electric heat must be selected; test operation allows ease of testing after installation (all timers are eliminated); non-volatile back-up memory, control settings are maintained for an indefi nite period during a power outage, when power is restored the equipment will resume operation after a three-minute compressor time delay; optional hand held infra-red controller. The control voltage between the indoor unit and the outdoor unit shall be 24 Volts A.C. The 24 Volts shall be generated from the indoor unit s 24 Volt 40VA transformer. The CHP (ceiling), CAH (recessed ceiling) and TBH T-bar indoor unit control system shall consist of 24V Wall Thermostat Control anti-short cycle compressor protection (excepttbh); fan purge, fan remains on for 60 seconds after heat/cool call is dropped for improved effi ciency (excepttbh); integral heating relay ensures that the fan operates whenever electric heat is energized; two stage heating capable when matched up with an EMI heat pump and an appropriate two stage thermostat. Wiring shall run from indoor unit to the 24V wall thermostat and to outdoor unit. NO SPLICES. When running low voltage wiring a double insulated 18 awg wire should be used. The control voltage between the indoor unit and the indoor units shall be 24 Volts A.C. The 24 Volts shall be generated from the indoor unit s 24 Volt 40VA transformer. Enviromaster International LLC 5

MH4 Piping Specifications Model Size Liquid (OD) Suction (OD) 09,12 1/4 1/2 15 1/4 5/8 18 3/8 5/8 24,30 3/8 3/4 PART SIX OUTDOOR UNIT The outdoor unit shall be completely factory assembled, piped and wired. Unit shall be of a multi-zone confi guration and contain multiple compressors sized per the equipment schedule. Each circuit is independent of the others. The cabinet shall be fabricated of G60 galvannealed steel, fi nished in off white with corrosion inhibiting polyester powdercoated paint. The unit shall be furnished with one (1) direct drive, propeller type fan arranged for vertical discharge when configured in the MH4 cabinet. The motor shall have inherent protection, be of the permanently lubricated type, and resiliently mounted for quiet operation. The fan shall be provided with a guard to prevent contact with moving parts. When equipment schedule calls for 9,000, 12,000 or 15,000 Btuh compressor circuits, the compressors shall be of the high-performance rotary type with Duratec package, which consists of an oversized accumulator, factory installed solid core fi lter drier, loss of charge switch and thermal overloads. When equipment schedule calls for 18,000, 24,000 or 30,000 Btuh compressor circuits, the compressors shall be of the high-performance reciprocating type with thermal overloads. The compressors shall be mounted as to avoid the transmission of vibration. The refrigeration system shall have the capability to operate with a maximum height difference of 35 feet and overall refrigerant tubing length of 100 feet between indoor and outdoor sections without the need for line size changes or additional oil. The condenser coils shall be of nonferrous construction with louvered fi ns bonded to rifl ed copper tubing. On FHP, WHP and CNR units with unit mounted controls, the system shall be controlled by the microprocessor in the indoor matching unit. The TBH, CAH and CHP are controlled by a 24V wall thermostat. Heating expansion is controlled by a TXV in the outdoor unit. The electrical power shall be 208/230 Volts, 1 phase, 60 Hertz. The system shall be capable of satisfactory operation within voltage limits of 208/230 Volts +/- 10%. PART SEVEN OPTIONAL EQUIPMENT Hand Held Infrared Remote Controller Option used to command the FHP and WHP unit-mounted controls. 24V Wall Thermostat Control Optional on the FHP (fl oor) and WHP (wall) indoor units anti short cycle protection. Infrared Control System (N/A on TBH) Optional on the CHP (ceiling) indoor unit. Infrared Control Package shall have the capability of sensing return air temperature and indoor coil temperature; large ¾ LCD backlit display; operational range adjustable between 55º F and 95º F in one-degree increments; anti-short cycle compressor protection; minimum compressor run time; fan purge, fan remains on for 60 seconds after heat/cool call is dropped for improved efficiency; freeze protection to prevent evaporator freeze ups; annunciation provides an audio feedback when the control settings are changed; universal control board allows the unit to operate with either a straight cool or heat pump condenser; two stage heating when optional electric heat and heat pump condenser are selected; fan operation of auto (cycling), high and low (constant), auto fan operation automatically selects fan speed according to heating or cooling demand; dry mode operates cooling and electric heat simultaneously to remove humidity, optional electric heat must be selected; test operation allows ease of testing after installation (all timers are eliminated); non-volatile back-up memory, control settings are maintained for an indefi nite period during a power outage, when power is restored the equipment will resume operation after a three-minute compressor time delay; optional hand held infra-red controller. http://www.enviromaster.com 6 emi@enviromaster.com

Electric Heat Optional on the following air handlers and shall be factory installed, only; automatic reset high temperature cutout and redundant high temperature fuse link: FHP Floor Indoor Unit: 9,000, 12,000 and 15,000 Btuh = 3 KW 18,000, 24,000 and 30,000 Btuh = 5 KW WHP Wall Indoor Unit: 9,000, 12,000, 15,000 and 18,000 Btuh = 3 KW 24,000 and 30,000 Btuh = 5 KW CHP Ceiling Indoor Unit: 9,000, 12,000 and 15,000 Btuh = 3 KW 18,000, 24,000 and 30,000 Btuh = 5 KW TBH T-Bar Indoor Unit: 9,000 and 12,000 Btuh = 3 KW 18,000 and 24,000 Btuh = 4.8 KW Wet Heat Chilled Water Internal Condensate Pump Shall be fi eld installed or factory installed and shall have the following head lift: FHP Floor Indoor Unit (all sizes) 12 feet WHP Wall Indoor Unit (all sizes) 4 feet CHP Ceiling Indoor Unit (all sizes) 4 feet CAH Recessed Ceiling Indoor Unit (all sizes) 18 inches TBH T-Bar Ceiling Indoor Unit (all sizes) 12 feet Low Ambient Control Optional on all models, heat pump is factory installed: Heat Pump Models: Factory Installed Shall consist of a hot gas bypass valve per circuit which maintains constant suction pressure Hard Start Shall be fi eld installed Sea Coast Coated Coils shall be factory installed; coating shall protect against corrosion due to acids, solvents and salt. 5780 Success Drive, Rome, NY 13440 Phone: 1-800-228-9364 FAX: 1-800-232-9364 Email: emi@enviromaster.com Enviromaster International LLC 7