VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

Similar documents
DAIKIN VRV AHU SYSTEM

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FBQ. DC Duct Heat Pump or Cooling Only

EHH SERIES DRAW THROUGH FAN COILS CFM

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Up to SEER 26.1 Wall Mount Heat Pump

Double Skin Casing Air Handling Units

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Double Skin Air Handling Units

Highly Efficient,Powerful Heating and Cooling.

YAH SERIES FAN COIL UNITS

FAQ. Wall Mount Heat Pump or Cooling Only

VRV IV i-series heat pump

Inverter Wall Mounted

DAIKIN Modular Inverter Air Cooled Chiller

FTQ. Daikin Inverter Ducted Heat Pump

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

LV Series. SEER 20+ Wall Mount Heat Pump

LV Series. SEER 15+ Concealed Built in Heat Pump

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

Advance Release September 2009

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Split Type Air Conditioners

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Inverter Wall Mounted

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

FOR REPLACEMENT USE PCV1213. Cooling Only 50 Hz

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

DAIKIN FAQ SERIES HEATING & COOLING SYSTEMS. INDOOR WALL-MOUNTED UNITS Up to 18.6 SEER / Up to 9.4 HSPF Up to 12.7 EER

Double Skin Air Handling Units

Modular Air Handling Unit

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Centeral Station Air Handling Unit

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

Submittal Data Performance Data Electrical Data

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7

HEATING & COOLING COIL PRODUCTS

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

Air conditioners Cooling only

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

NFZP Variable Refrigerant Flow Guide Specification

ROOFTOP PACKAGED AIR CONDITIONERS

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

Technical Data Ducted Three Phase Split System Air Conditioner

The plug & play fresh Air Solution

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Integrated VarIable refrigerant flow ahu/pau (r410a)

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

Daikin air conditioners for your home, shops, restaurants and offices

Digital Inverter 4 series 8 & 10HP

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

SKYPAK II, 3 Ton Series, gives you a

FAN COIL UNITS. The optimal solution for limited space

Compact design & easy maintenance

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Si REMOVAL PROCEDURE. 2.5/3.2/3.5 kw Class. Outdoor Unit Inverter Pair Type

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Inverter Wall Mounted

GUIDE SPECIFICATIONS AQUARIUS ii

VariCool VAV Engineering Guide

Water-Cooled Self-Contained Units

technical guide Water-Cooled Self-Contained Units

39G Air Handling Unit

Product Specifications. Vertical Floor Consoles By First Co.

ED-FUW-2014 (50 Hz/60 Hz) Catalogue/Engineering Data. Large-Sized Chilled Water Fan Coil Unit (50/60 Hz) FUW040A DAIKIN INDUSTRIES, LTD.

Table of Contents. Page 2

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Transcription:

Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. PREVIEW Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. APVVDT1402 If you have any enquiries, please contact your local importer, distributor and/or retailer. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. Daikin Industries (Thailand) Ltd. ed Business Center II Building, Floor 17 591 Sukhumvit Rd, Sukhumvit 33, North Klongton, Wattana, Bangkok 10110 System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA *Specifications, designs and other content appearing in this brochure are current as of April 2014 but subject to change without notice. All rights reserved

Airport Introduction Daikin release a new standard series unit model AHUR-CA/SA (Single Skin / Double Skin). It is a DX AHU system that is specially designed to work with the outdoor unit. This new model release is an inlet temperature control type AHU. This will enable the users to reduce maintenance costs and enjoy more space savings. Lobby AHUR-CA/SA also improves the indoor air quality from haze, pollutants, etc using the options of pre-filers and primary filters. are the only total AHU solutions provided and manufactured completely by Daikin. Hospital Total Daikin Solutions Applications Air Handling Factory (All products manufacture by Daikin Factory) Control Wiring Remote Control Wiring (P1 P2) System Connection Overview Liquid Gas Shopping Mall What is VRV Application Daikin VRV system is a multi-split type air conditioner for commercial buildings that uses variable refrigerant flow control developed by Daikin. For small to large commercial spaces Daikin offers a range of R-410A inverter condensing units for use in conjunction with Air Handling s (AHU) from 6 HP to 60 HP. AHU provide large volumes and high ESPs (External Static Pressure) enabling the use of extensive ductwork runs. The refrigerant flows through the copper pipes using R-410A and operates like a large VRV fan coil unit. Sports Hall Showroom Warehouse It enables long piping length up to 165m and maximum level difference (between outdoor and indoor units) of 90m to provide more design flexibility which can match even large-sized buildings. It allows one touch selection control using intelligent Touch Manager and includes options to link with BACnet to enhance the Building Management System (BMS). 01 Daikin AHU represents the ideal solution for large storage places, atrium, lobby, banquet halls, showrooms, exhibition halls, shopping malls, etc. It also have the options to customize the specifications such as the filtration type, direction of air in-take and discharge, service access door and blower type (backward or forward curves and plug fan). 02

Comparison Table and Diagram for Conventional AHU System and System Conventional AHU System Harnessing current and latest technology of VRT Inverter controlled system (only Z - Control) Can be easily controlled via standard wired remote control (BRC1E62) Comes in dual skin type model - double skin panel model and single skin panel model Easily manage using intelligent Touch Manager central control system Communication protocol using DIII-Net to communicate with all existing Dakin communication devices and even BMS. Can be placed indoor or outdoor* *Optional items required Benefits of using Quality assured are manufactured by Daikin factory. Ease of the installation No additional system such as cooling tower, chiller, and long water piping system are required. This also reduces the total system maintance costs. Flexible design of the ducting system. Cover large area with different ducting configuration. can provide ESP up to 500Pa* (Standard Model) Total solution concept Integrating an AHU into the total building climate system enables both design and installation procedures to be based on a single common technology. This simplifies project follow-up, installation, commissioning and maintenance since only one party is involved. system can be coupled and mixed with other type indoor unit to work together concurrently. (Connection ratio 50% - 110%) Options Wide range of options are available to meet your design requirements. Please contact Daikin s Sales regarding below mentioned options: Fan Type Backward Curve Aerofoil Plug Fan AHU Coil Material Type Blue Fin Copper Fin Gold Fin Aluminum Tube Stainless Tube Anti-Corrosive Epoxy Coating AHU Drain Pan Type Steel Coating with Acrylic Enamel Galvanized Steel AHU Air Filter Type Medium Filter Extra Filter Synthetic Bag HEPA Aluminum Cartridge ULPA Special Option Electric Heater Mixing Box Outdoor Roof Panel Thickness 50mm Customisation Airflow Capacity ESP Discharge Direction Piping Outlet Require Frequent Maintenance ( Tower + Chiller) Easy Maintenance (same as common A/C System) Higher Cost Due to Frequent Maintenance No Additional Maintenance Cost Require Larger Installation Space (AHU, Chiller, Tower) Require Small Installation Space (AHU, VRV) Complex System (HVAC Ducting, Chiller and Water Piping) Simple System (HVAC Ducting) Extensive Control (Variable Frequency Device, Variable Air Volume Control) Simple Control (Remote Control / intelligent Touch Manager) Free Space Tower Lobby Lobby AHU Chiller Conventional AHU System Max. 90m Features of Inlet Temperature control System AHU Underground Basement Carpark System * For ESP more than 500Pa, please contact Daikin s Sales 03 04

Inlet Temperature Standard Series Range Possibility Z (Ts/Tr control): The standard series are available from the capacity range of 6HP to 60HP, also with airflow ranging from 3,240 CMH 28,080 CMH. Using Daikin wired remote controller (BRC1E62 optional) Set point can be fixed via standard Daikin wired remote controller. Remote ON/OFF can be achieved by an optional adapter KRP4AA51. 60 HP No additional external controller is required. The cooling load is determined from the air suction temperature and set point on the Daikin controller. 28.08 Capacity 50 HP 23.40 40 HP 18.27 30 HP Standard Series Coil, Expansion Valve Kit and Control Box AHUR-CA/SA standard series model is using the DX coil. Each DX coil will be connected to one external expansion valve kit (EKEXV) and controlled by one control box kit (EKEQMCB). Standard Series Coil 3 Type of Coils - 6HP used by 6HP, 12HP AHU unit - 8HP used by 8HP, 16HP AHU unit - 10HP used by 10HP, 20HP, 30HP, 40HP, 50HP, 60HP AHU unit 14.04 9.36 16 HP ON / OFF 8.16 12 HP KRP4AA51 6.48 10 HP 4.68 8 HP Ts Te 4.08 6 HP Daikin control box: EKEQMCB 3.24 0 5 10 15 20 25 30 Expansion Valve Kit (EKEXV) Td 3 Type AHU Expansion Valve Kit - EKEXV140 for 6HP Coil - EKEXV200 for 8HP Coil - EKEXV250 for 10HP Coil AHU BRC1E62 Tr Room Control Box Kit (EKEQMCB) Airflow (x 103 CMH) Expanded Line Up for Daikin VRV Indoor Series Comparison for External Static Pressure and Capacity between and Duct Typed offers higher ESP and Capacity as compared to duct typed unit. VRV AHU Expansion Valve Kit 200 400 Te = Evaporating temperature AHU = Air Handling FXMQ FXMQ 0 Ts = Air suction temperature Td = Air discharge temperature Tr = Room temperature 0 600 10 20 30 40 50 60 70 External Static Pressure (Pa) From To FXMQ 100 Pa 270 Pa 250 Pa 500 Pa Capacity (HP) VRV AHU Control Box Kit EKEXV140 Casing Colour Ivory white Material Metal Dimensions H x W x D mm Weight Kg Operation Range Min. ~ Max. CDB Type / OD mm R-410A Braze connection / 9.52 Gas Type / OD mm Heat Insulation Braze connection / 9.52 Both inlet and outlet Power Supply Phase Frequency Hz Voltage V H x W x D mm Kg Min. ~ Max. CDB FXMQ 2 HP 10 HP Operation Range 6 HP 60 HP Refrigerant Piping connections Outdoor Colour Material Weight To Multi Application Casing Dimensions From EKEQMCB EKEXV200 EKEXV250 Type Liquid 401 x 215 x 78 2.9-5.0 ~ 46.0 White grey Resin 132 x 400 x 200 3.6-10.0 ~ 40.0 1 50 230 Operation Range Entering Air Temperature On Heat Exchanger AHU Outdoor Expansion Valve Kit Control Box 05 VRV 4 Temperature Range 14 C WB 35 C DB / 25 C WB -5 C DB 43 C DB -20 C WB 46 C DB -10 C WB 40 C DB Height AHUR-CA/SA operation is similar as other VRV indoor unit. Following table is the list of operation range limit condition for the AHU unit to work. Width Front View Depth Side View 06

VRV Connection to AHU Configuration 6 60 HP 6 Single VRV System Connection Configuration Multiple Connections with Other Indoor Configuration Each coil up to 10 HP (Max combination of 6) = 60 HP Up to 60 HP Max.6 circuits VRV Combined System Connection Configuration Control Wiring 07 Remote Control Wiring (P1 P2) Liquid Multiple VRV Systems Connection Configuration Gas 08

3 AHU SPECIFICATION (CA/SA) AHU SPECIFICATIONS 1 2 3 4 5 6 7 8 CASING / INSULATION (CA SERIES) CASING / INSULATION (SA SERIES) CASING-FRAME COIL TUBE FIN HEADER FRAME WORKING PRESSURE FAN TYPE WHEEL HOUSING FRAME MOTOR VIBRATION ISOLATOR DRAIN PAN AIR FILTER 25mm Thickness Single Skinned Panel 0.5mm Thickness White Colourbond Steel Sheet 25mm Thickness PU Foam 40Kg/M 3 20mm Thickness Single Skinned Panel 1.2mm Thickness Steel Sheet with Ivory White Powder Coated 20mm Thickness PU Sponge 18Kg/M 3 Density Steel Made With Black Colour Epoxy Paint DX Coil Copper Tube Aluminum Made Copper Tube Galvanized Steel 10Kg/cm 2 G or Below (Brand = Kruger) Double Inlet Forward Curved Centrifugal Belt Drive Fan Galvanized Steel Galvanized Steel Steel With Polyester Powder Coated (Brand = Inline) Three-Phrase Induction Motor Totally Enclosed Fan-Cooled Type Protection = IP55 Insulation Class = F Spring Isolator Drawings and Dimension of AHU Model AHUR06CA/SA AHUR08CA/SA AHUR10CA/SA AHUR12CA/SA AHUR16CA/SA AHUR20CA/SA AHUR30CA/SA AHUR40CA/SA AHUR50CA/SA AHUR60CA/SA Dimension W x D x H (mm) 1300 x 1300 x 1100 1300 x 1200 x 1100 1500 x 1200 x 1100 1400 x 1500 x 1300 1400 x 1500 x 1300 1500 x 1500 x 1300 1500 x 1900 x 1900 1500 x 1900 x 2200 2800 x 2000 x 1800 2800 x 2100 x 1800 * Dimension does not include Control Box, Expansion Valve and Pre-filter 1.2mm (SUS 304) Beneath The Drain Pan is Covered With 20mm PE Insulation 35Kg/M 3 Density (Brand = AAF) Type = R29 Class = G3 (AFI = 80%) washable Size = Full (24" x 24" x 2") Half (12" x 24" x 2") Frame Galvanized Steel Width Front View Height Depth Side View 110 (Filter) Model AHUR06CA/SA AHUR08CA/SA AHUR10CA/SA AHUR12CA/SA AHUR16CA/SA Total Capacity 16.9 16.8 16.7 16.5 16.4 22.9 22.8 22.7 22.4 22.3 28.4 28.3 28.2 28 27.8 34 33.8 33.7 33.3 33 45.5 45.3 45.1 44.7 44.5 NET *1 Total Sensible Capacity 12.4 12.3 12.2 12 11.9 16.8 16.7 16.6 16.3 16.2 20.9 20.8 20.7 20.5 20.3 25 24.8 24.7 24.3 24 33.3 33.1 32.9 32.5 32.3 Total Capacity 17.9 24.0 29.8 35.8 48.0 GROSS *2 Sensible Capacity 13.4 17.9 22.3 26.8 35.8 Air Flow CMH 3,240 4,080 4,680 6,480 8,160 Ent.Temp. ⁰CDB/⁰CWB 27/19 27/19 27/19 27/19 27/19 Lea.Temp. ⁰CDB/⁰CWB 14.4/13.1 13.6/12.7 12.5/12.4 14.4/13.1 13.6/12.7 Coil Type DX.COIL(R410A) ф8mm. WAVE SLIT SURFACE & STRAIGHT EDGE Coil Face Area m 2 0.491 0.443 0.54 0.982 0.886 Coil Face Vel. m/s 1.83 2.56 2.41 1.83 2.56 Air PD.In Coil Pa 100 100 100 100 100 Air PD.In Pre Filter *3 Pa 80 80 80 80 80 Air Filter Size 12"X24X2" *3 PCS. 1 1-2 2 Air Filter Size 24"X24X2" *3 PCS. 1 1 2 2 2 Air PD.In Casing Pa 30 30 30 30 30 ESP.Initial Pa 250 300 350 450 500 250 300 350 450 500 250 300 350 450 500 250 300 350 450 500 250 300 350 450 500 Total Statics Pressure Pa 460 510 560 660 710 460 510 560 660 710 460 510 560 660 710 460 510 560 660 710 460 510 560 660 710 Fan Type Model FSA315CM FDA250TM FDA250TM FDA315TM FDA315TM Fan Motor *4 1.5 2.2 1.5 2.2 2.2 3.0 2.2 3.0 4.0 3.0 4.0 POLE 4 4 4 4 4 Power Supply Volt/Ph./Hz. 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 FLA amp. 3.7 5.0 3.7 5.0 5.0 6.76 5.0 6.76 8.8 6.76 8.8 Machine Weight kg 485 495 480 485 530 540 610 620 630 630 640 Outlet Sound Level ( Pressure ) dba 84 85 86 88 89 77 78 79 81 82 77 78 79 81 82 87 88 89 92 93 87 88 89 91 92 Control Box Kit Model / PCS. EKEQMCBV3 / 1 pcs. EKEQMCBV3 / 1 pcs. EKEQMCBV3 / 1 pcs. EKEQMCBV3 / 2 pcs. EKEQMCBV3 / 2 pcs. Expansion Valve Kit Model / PCS. EKEXV140 / 1 pcs. EKEXV200 / 1 pcs. EKEXV250 / 1 pcs. EKEXV140 / 2 pcs. EKEXV200 / 2 pcs. Liquid pipes mm 9.5 (Brazing connection) 9.5 (Brazing connection) 9.5 (Brazing connection) 9.5 (Brazing connection) x 2 9.5 (Brazing connection) x 2 Piping Gas pipes *5 mm 19.1 (Brazing connection) 22.2 (Brazing connection) 28.6 (Brazing connection) 19.1 (Brazing connection) x 2 22.2 (Brazing connection) x 2 Connections Drain pipes mm 32 32 32 32 32 Refrigerant Control Electronic expanison valve Electronic expanison valve Electronic expanison valve Electronic expanison valve Electronic expanison valve Panel CA/SA Double Skinned/Single Skinned Capacity Index 157 214 266 313 429 Model AHUR20CA/SA AHUR30CA/SA AHUR40CA/SA AHUR50CA/SA AHUR60CA/SA Total Capacity 57.3 57.1 56.9 56.4 56.2 86.1 85.8 85.5 84.9 84.6 115 114 114 113 113 144 143 143 142 141 172 172 171 170 169 NET *1 Total Sensible Capacity 42.3 42.1 41.9 41.4 41.2 63.6 63.3 63 62.4 62.1 84.5 84.2 83.8 83 82.6 106 106 105 104 104 127 127 126 125 124 Total Capacity 59.6 89.4 119.2 149.0 178.8 GROSS *2 Sensible Capacity 44.6 66.9 89.2 111.5 133.8 Air Flow CMH 9,360 14,040 18,720 23,400 28,080 Ent.Temp. ⁰CDB/⁰CWB 27/19 27/19 27/19 27/19 27/19 Lea.Temp. ⁰CDB/⁰CWB 12.5/12.4 12.5/12.4 12.5/12.4 12.5/12.4 12.5/12.4 Coil Type DX.COIL(R410A) ф8mm. WAVE SLIT SURFACE & STRAIGHT EDGE Coil Face Area m2 1.08 1.62 2.16 2.7 3.24 Coil Face Vel. m/s 2.41 2.41 2.41 2.41 2.41 Air PD.In Coil Pa 100 100 100 100 100 Air PD.In Pre Filter *3 Pa 80 80 80 80 80 Air Filter Size 12"X24X2" *3 PCS. 2 2-4 4 Air Filter Size 24"X24X2" *3 PCS. 2 4 6 8 8 Air PD.In Casing Pa 30 30 30 30 30 ESP.Initial Pa 250 300 350 450 500 250 300 350 450 500 250 300 350 450 500 250 300 350 450 500 250 300 350 450 500 Total Statics Pressure Pa 460 510 560 660 710 460 510 560 660 710 460 510 560 660 710 460 510 560 660 710 460 510 560 660 710 Fan Type Model FDA355TM FDA450TM FDA500TM FDA560TM FDA630TM Fan Motor *4 3.0 4.0 4.0 5.5 5.5 7.5 7.5 11 11 POLE 4 4 4 4 4 Power Supply Volt/Ph./Hz. 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 FLA amp. 6.76 8.8 8.8 11.5 11.5 15.3 15.3 22.3 22.3 Machine Weight kg 665 675 880 895 980 1000 1420 1460 1540 Outlet Sound Level (Pressure) dba 82 83 84 86 88 85 86 87 89 91 85 86 87 89 89 86 87 87 89 90 84 84 85 87 88 Control Box Kit Model / PCS. EKEQMCBV3 / 2 pcs. EKEQMCBV3 / 3 pcs. EKEQMCBV3 / 4 pcs. EKEQMCBV3 / 5 pcs. EKEQMCBV3 / 6 pcs. Expansion Valve Kit Model / PCS. EKEXV250 / 2 pcs. EKEXV250 / 3 pcs. EKEXV250 / 4 pcs. EKEXV250 / 5 pcs. EKEXV250 / 6 pcs. Liquid pipes mm 9.5 (Brazing connection) x 2 9.5 (Brazing connection) x 3 9.5 (Brazing connection) x 4 9.5 (Brazing connection) x 5 9.5 (Brazing connection) x 6 Piping Gas pipes *5 mm 28.6 (Brazing connection) x 2 28.6 (Brazing connection) x 3 28.6 (Brazing connection) x 4 28.6 (Brazing connection) x 5 28.6 (Brazing connection) x 6 Connections Drain pipes mm 32 32 32 32 32 Refrigerant Control Electronic expanison valve Electronic expanison valve Electronic expanison valve Electronic expanison valve Electronic expanison valve Panel CA/SA Double Skinned/Single Skinned Capacity Index 532 798 1064 1330 1586 * Dimension does not include Control Box, Expansion Valve and Pre-filter Notes: 1. Net capacity includes indoor fan heat. 2. Gross capacity does not include indoor fan heat. 3. With pre filter, AAF synthetic R29 & class G3 (Wasable) eff 80-85%. 4. Motor is induction motor class F, IP 55. 5. It is necessary to reduce piping size by reducer when connection (19.1 15.9, 22.2 19.1, 28.6 22.2) 6. The connection ratio of the outdoor unit must be within the limits specified by the outdoor unit and must additionally be within 50% and 110%. Conversion formular kcal/h=kwx860 cfm=m3/minx35.3 09 10