Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

The display section precisely shows the current status to onsite operators. Displayable Status Easily Recognize the PV Easily See

UDC100 Universal Digital Controller Specifications

Nov 08 PRODUCT SPECIFICATION SHEET

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

TEMPERATURE CONTROLLER

Temperature Controllers

UDC 700 Universal Digital Controllers and Indicator Specifications

Temperature Controller

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Specification , July 2015

Universal controller for panel mounting Models CS6S, CS6H, CS6L

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Process & TeMPerATUre UniversAl input DigiTAl MeTers

MC-5 Series Micro Processor Temperature Controller

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

INSTRUCTION MANUAL Micro-computer based digital indicating controller

+ A B V B NO NC V COM PV PV

Metronomis. city beautification luminaire. lighting solutions that really last

Infrared port USB. Control Output 2. (built-in) SSR outputs

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

I/A Series 716C 1/16 DIN Temperature Controller

02/11/2015

ALM 1 OUT 1 2 FUNCTION AUTO TUNE. Figure 1 - UDC2000 Mini-Pro Controller. Features, continued

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

OWNER S HANDBOOK FOR WET & DRY VACUUM CLEANERS FLEXIO II / MODEL : Z 930 / Z 931

SX65 and SX75. Electronic process controllers

02/11/2015

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

E5CN/E5CN-U (48 x 48 mm)

Laboratory Gas Sensor Solutions

Oakton TEMP 9500 Advanced Multiparameter Controller

Series Temperature Controller Instruction Sheet

Model 144H. Product Data Sheet , Rev DB February Content

2-Stage Indoor Condensing Unit for Refrigeration Applications (15-30 HP) Product catalogue

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

TC515 and TC600 Installation Manual. a Winters company

Instruction manual for DIN rail mounting type indicating controller DCL-33A

Series Digital Controller Instruction Sheet

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Example of Applications and Parameter Functions

GCS-300 No.GCS31E

Fusion for refrigeration application

Instruction manual Micro-computer based digital indicating controller

NGC-40 Advanced Heat-Tracing Control System

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Programmable Temperature Controller (Digital Controller)

Copeland Scroll TM Compressor Fusion for refrigeration applications

F4 Process Controller Installation and Operation Guide

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Bulletin 900-TC. Bulletin 900 TC Temperature/Process Controllers. Certifications. Bulletin 900-TC8 Controller Models

Hardware Instruction Manual. SR Mini HG SYSTEM. High-performance Multi-point Control System IMSRM15-E4 RKC INSTRUMENT INC.

SR Mini HG SYSTEM. High-performance Multi-point Control System. SR Mini HG SYSTEM. Hardware Instruction Manual IMSRM15-E6 RKC INSTRUMENT INC.

R-Series Wiring Devices

Pure Glass. saturn.clipsal.com

Temperature. Table of Contents. Temperature Controllers pgs Indicators/Transmitters pgs Thermometers pgs

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

MICRO CONTROLLER S Z SERIES

HTC-915-CONT. Heat-Trace Control system

All Electric Servo Drive Injection Molding Machine

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

TEMPERATURE CONTROL MODULE MODEL R3-TC2

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

910 Series Single-point heat-tracing control system

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

DC1000 Series Digital Controller Product Manual August 2005

7EF/7HF/7EC/7ES Temperature Controllers

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

E5CN/E5CN-U (48 x 48 mm)

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Model 96VTR ¼ DIN Process Controller

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

Model 144H. Product Data Sheet , Rev DB February Content

Digital Temperature Controller E5AZ

E5CN/E5CN-U (48 x 48 mm)

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Model D12-IR. Digital Gas Transmitter...

E5AN/E5EN (96 x 96 mm and 48 x 96 mm)

TER Active Room Temperature Sensor (Controller),

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER


AutomationDirect. PC35 Configuration Sheet

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

E5CN Temperature Controller User s Manual

Digital Temperature Controller

Transcription:

Selection Guide To Temperature Controllers

E5 J Temperature Controllers Fuzzy Self-tuning with Advanced PID for Optimum Temperature Control No Tuning Required E5 J requires NO tuning after initial setting. Just set the desired temperature. Optimum PID constants are automatically calculated. The result is time saving. PID is checked at: DISTURBANCE Easy Setting Step 1 1 234567890 Choose sensor FINISH! Step 2 Plug in selected output unit ( Except for E5CJ) RISING EDGE SP CHANGE FLUCTUATION Step 4 PV SV Enter the set point Step 3 PV SV Set control period (Not required for current output) Input Selectable temperature input from a wide range of temperature sensors. Output Selectable plug-in modules of relay, voltage or linear output units, according to the application. Watertight The E5 J front panel meets the requirement of IP54 on E5AJ/E5BJ/E5EJ. Additional IP66/NEMA4 can be met with optional cover. Communication Function The E5AJ/E5EJ provide the optional RS232/RS422/RS485 communication functions and RUN/STOP operation by external input. RUN STOP

E5 K Digital Controllers Centralized Control of Various Data to Satisfy Application Needs such as Temperature, Humidity, Pressure, etc. SYSMAC α C200HX/HG/HE By connecting to a SYSMAC α communication board, data communication can be easily made using ladder instructions as protocol macro functions. IBM PC/AT or compatible PC Serial Communications E5AK and E5EK only Remote SP Transfer Output HEAT/ COOL K3TX Intelligent Signal Processor Temperature Input E5AK and E5EK only Analog Input Control Valve Output Temperature Sensors G3PX Power Controller ES1 Infrared Thermosensor G3PA SSR

SELECTION GUIDE Classification Product Model Economical Temperature Controllers E5EM E5C2 E5CS Appearance Dimensions (H x W x L) mm 96 x 48 x 100 48 x 48 x 96 48 x 48 x 100 Features P control Thumbwheel switch setting Maximum heater current: AC 5A/20A/30A single phase (SW selectable) Deviation indication (meter) / LED PV display ON/OFF or PD control Economical plug-in unit Panel adapter supplied PID or ON/OFF control Compact, panel mount or socket mount unit Large, easy to read LED display Selectable temperature ranges Input shift 8 alarm modes Model Variations Heater burnout alarm Digital indication Deviation indication (meter) Indication Accuracy ±1.5% max. of full scale ±2% max. of full scale (setting) ±0.5% of full scale, ±1 digit max. Control Modes P ON/OFF or PD Temperature Sensors and Input Ranges Type K Thermocouple: 0 to 399 C Type K Thermocouple: 0 to 1,200 C (7 scales) Type J Thermocouple: 0 to 400 C (3 scales) JPt100: -50 to 400 C (7 scales) Thermistor: -50 to 300 C (5 scales) Type K Thermocouple: 0 to 999 C (6 ranges) Type J Thermocouple: 0 to 500 C (5 ranges) JPt100, Pt100: -50 to 400 C (9 ranges) Thermistor: -50 to 300 C (10 ranges) Supply Voltage 100/110 or 200/220VAC, 50/60Hz 100/110 or 200/220VAC, 50/60Hz or 24VDC/AC Control Outputs Relay: SPDT, 3A, 250VAC (Resistive load) Relay: SPDT, 3A, 250VAC (Resistive load) Relay: SPDT, 3A, 250VAC (Resistive load) Voltage: 12VDC, 20mA Alarm: SPST-NO, 1A, 250VAC (Resistive load) Weight (Approx.) 340g 200g 170g Front Panel Approval Approved Standards & Markings UL, CSA, CE UL, CSA, CE * For further details, consult OMRON representatives.

General Purpose Temperature Controllers Advance Temperature Controllers E5 W E5 J E5 X E5AW: 96 x 96 x 100 E5BW: 72 x 72 x 100 E5CW: 48 x 48 x 100 E5EW: 96 x 48 x 100 Automatic tuning PID or ON/OFF control Selectable temperature ranges Displays Present Value and Set Value simultaneously Input shift 8 alarm modes E5AJ: 96 x 96 x 98 E5BJ: 72 x 72 x 98 E5CJ: 48 x 48 x 100 E5EJ: 96 x 48 x 98 Fuzzy advanced self-tuning, PID control with two degrees of freedom or ON/OFF control Selectable temperature inputs Plug-in output modules (except E5CJ) 4 event inputs (E5AJ, E5EJ) Heater burnout alarm 9 alarm modes E5AX: 96 x 96 x 89 E5BX: 72 x 72 x 89 E5CX: 48 x 48 x 87.5 E5EX: 96 x 48 x 89 Advanced PID control with two degrees of freedom improves stability and response speed Select from 7 temperature sensors for a total of 14 temperature ranges 8 alarm modes Heater burnout alarm Communication options (E5AJ, E5EJ only) RUN/STOP operation (E5AJ, E5EJ only) Position - proportional control Heat & cool control Communication options (E5AX, E5EX only) ±0.5% of full scale, ±1 digit max. ±0.5% of set value or ±1 C, ±1 digit max. ±0.3% of set value, 1 digit max. Type K Thermocouple: 0 to 999 C (6 ranges) Type J Thermocouple: 0 to 500 C (4 ranges) JPt100, Pt100: -50 to 400 C (9 ranges) or 24VAC/DC Type K Thermocouple: -200 to 1,300 C Type J Thermocouple: -100 to 850 C Type T Thermocouple: -199.9 to 400.0 C Type N Thermocouple: -200 to 1,300 C JPt100, Pt100: -199.9 to 650.0 C Type K Thermocouple: -200 to 1,300 C Type J/L Thermocouple: -100 to 850 C Type T/U Thermocouple: -200 to 400 C Type E Thermocouple: 0 to 600 C Type R/S Thermocouple: 0 to 1,700 C JPt100, Pt100: -99.9 to 450.0 C Relay: SPDT, 3A, 250VAC (Resistive load) Voltage: 12VDC, 20mA Alarm: SPST-NO, 1A, 250VAC (Resistive load) SSR: SPST-NO, 1A, 75-250VAC 24VDC, NPN / PNP, 20mA Linear: 4 to 20mA / 0 to 20mA 0 to 10VDC / 0 to 5VDC SSR: SPST-NO, 1A, 75 to 250VAC 24VDC, NPN / PNP, 20mA Current: 4 to 20mA DC 150 to 300g UL, CSA 170 to 360g UL, CSA, EN/IEC, CE 160 to 400g UL, CSA, SEV

Digital Controllers E5 K Special Purpose Temperature Controllers E5 F E5AK: 96 x 96 x 100 E5CK: 53 x 53 x 100 E5EK: 96 x 48 x 100 E5AF: 96 x 96 x 100 E5EF: 96 x 48 x 100 Modular structure Fuzzy self-tuning, advanced PID or manual control Auto/manual operation Heat & cool control Selectable temperature & analog input Multi-set point, SP ramp function Event input Plug-in control output & optional units Transfer output 11 alarm modes Position-proportional control (E5AK, E5EK only) Heater burnout alarm (E5AK, E5EK only) Communication options Remote set point (E5AK, E5EK only) Loop break alarm (E5AK, E5EK only) ±0.3% of indication value, ±1 digit max. Improve response to disturbance through Fuzzy logic Hybrid Fuzzy-PID control with auto-tuning Selectable temperature inputs Plug-in control output modules Displays Present Value and Set Value simultaneously Input shift Two alarm outputs with 9 modes each Easily adjustable Fuzzy parameters Communication options 8 memory banks (E5EF-B only) Heater burnout alarm ±0.3% of set value, ±1 digit max. Thermocouples types: K, J, T, E, L, U, N, R, S, B, W, PL II (-199.9 to 2,300 C) Platinum RTD: Pt100, JPt100 (-199.9 to 650.0 C) Current: 4 to 20mA, 0 to 20mA Voltage: 1 to 5VDC, 0 to 5VDC, 0 to 10VDC, 24VAC/VDC Relay: SPST, 3A(5A*), 250VAC (Resistive load) SSR: 1A, 75 to 250VAC* * 24VDC, NPN / PNP, 20mA* 12VDC, NPN / PNP, 20mA (E5CK only) Linear: 0 to 10VDC, 4 to 20mA 0 to 5VDC*, 0 to 20mA * E5AK/E5EK only 170 to 450g IEC IP66 UL, CSA, EN/IEC, CE Type K Thermocouple: -200 to 1,300 C Type J Thermocouple: -100 to 850 C Type T Thermocouple: -200 to 400 C Type N Thermocouple: 0 to 1,300 C JPt100, Pt100: -99.9 to 450.0 C Types E, R, S and B also applicable SSR: SPST-NO, 1A, 75 to 250VAC 24VDC, NPN / PNP, 20mA Current: 4 to 20mA DC 310 to 430g UL, CSA

TEMPERATURE CONTROLLERS Process Controllers ES100 Humidity Controllers E5RA 96 x 96 x 160 96 x 96 x 100 User-configurable advanced process controller Support software for programming and monitoring via PC Front panel keys can be assigned with any available function Incorporates Fuzzy Logic and advanced PID for high precision control Cascade control & proportional control can be performed Programmable up to 99 patterns and 99 steps (max. 400 steps) Programmable event function 4 key protection levels Advanced PID control of relative humidity with two degrees of freedom Easy maintenance with ceramic humidity component Displays Present Value and Set Value simultaneously Aging monitor for sensor 2 alarm outputs with 8 modes each Key protection Plug-in output modules Ramp/Soak programmable Built-in timers and tune signals Expansion I/O; communications ±0.1% of indication value, ±1 digit max. ±1% of set value, ±1 digit max. Thermocouples types: K, J, T, E, L, U, N, R, S, B, W, PL II (-199.9 to 2,300 C) Platinum RTD: Pt100, JPt100 (-199.9 to 600 C) Current: 4 to 20mA, 0 to 20mA Voltage: 0 to10mv, 0 to 100mV, -10 to 10mV, 0 to 1V, 1 to 5V, 0 to 5V, 0 to 10V Omron humidity sensor Part No: E54-RA Replacable humidity sensor module Part No: E54-RB SSR: SPST-NO, 1A, 75 to 250VAC 24VDC, NPN / PNP, 20mA Current: 4 to 20mA DC SSR: SPST-NO, 1A, 75 to 250VAC Current: 4 to 20mA DC 800g (IP66 with optional cover) UL, CSA, EN/IEC, CE 400g UL, CSA

Precision Temperature Control CYCLE CONTROL UNIT Employs a cycle control method that allows power control with minimal noise generation. Used in combination with G3PA to connect to single-and three-phase loads. Control signals can be input with the built-in adjuster, the external adjuster, or a DC signal current of 4 to 20 ma. Closely mounted to G3PA with the linking terminal. 100 to 240 VAC supply voltage. SOLID STATE RELAY Downsizing achieved through optimum design of heat sink. Dense mounting possible with linking terminals. Applicable with 3-phase loads. Replaceable power element cartridges. Conforms to VDE 0106 (finger protection), with a dielectric strength of 4,000 V between input and load. (see note) Conforms to VDE 0805, IEC 950. (see note) Note: Except for G3PA-420B/-430B OMRON ASIA PACIFIC PTE LTD 139 Joo Seng Road, #04-01 ATD Centre, Singapore 368362 Tel: (65)-2830006 Fax: (65)-2850682 With effect from December 1997: 83, Clemenceau Avenue, #11-01 UE Square, Singapore 239920 Malaysia Office: OMRON ELECTRONICS SALES AND SERVICE (M) SDN BHD (222675-U) 10th Floor, Block B Menara PKNS-PJ No.17 Jalan Yong Shook Lin 46050 Petaling Jaya Selangor Darul Ehsan, Malaysia Tel: (03)-7547323 Fax: (03)-7546618 Indonesia Office: OMRON ASIA PACIFIC PTE LTD INDONESIA REPRESENTATIVE OFFICE Wisma Danamon Aetna Life Tower, 16th Floor JL. Jend Sudirman Kav. 45-46 Jakarta 12930, Indonesia Tel: (021)-5770838 Fax: (021)-5770840 Thailand Office: OMRON ELECTRONICS CO., LTD Rasa Tower 20th Floor, 555 Phaholyothin Road Chatuchak, Bangkok 10900, Thailand Tel: (02)-9370500 Fax: (02)-9370501 Philippines Office: OMRON ASIA PACIFIC PTE LTD MANILA REPRESENTATIVE OFFICE 3rd Floor, Kings Court II Building 2129 Pasong Tamo Street, 1231 Makati City, Metro Manila, Philippines Tel: (02)-8112375 Fax: (02)-8112377 India Office: OMRON ASIA PACIFIC PTE LTD INDIA LIAISON OFFICE 59 Hemkunt, Opp. Nehru Place New Delhi- 110048, India Tel: (011)-6238431 Fax: (011)-6238434 Australia Office: OMRON ELECTRONICS PTY. LTD. Omron House 71 Epping Road, North Ryde, Sydney New South Wales 2113, Australia Tel: (02)-98786377 Fax: (02)-98786981 Toll Free: 1800-678838 New Zealand Office: OMRON ELECTRONICS LTD. 65 Boston Road, Private Bag 92620 Symonds Street, Auckland, New Zealand Tel: (09)-3584400 Fax: (09)-3584411 Visit our website at http://www.omron.com.sg Vietnam Office: OMRON ASIA PACIFIC PTE LTD HO CHI MINH REPRESENTATIVE OFFICE 99 Nguyen Thi Minh Khai Street, District 1 Ho Chi Minh City, SR Vietnam Tel: (08)-8301105 Fax: (08)-8301279 HANOI REPRESENTATIVE OFFICE Tel: (04)-8221273 Fax: (04)-8221278 Cat. No. X203-E1-1-SN * Note: Specifications subject to changes without notice. Printed in Singapore 0897-1B