Specialties Quality, Durability, Reliability. FIrE ProTECTIon

Similar documents
E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing

Additional Bulletins applicable to all F1RES LL Sprinklers Wall Wetting - Bulletin 007 Design and Installation - Bulletin 140

Model F3 Dry Sprinklers

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

FIRE SUPPRESSION SPRINKLER SYSTEM

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

SECTION SPRINKLER SYSTEMS

Model F1FR Series Quick Response Standard Spray

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

40.15 V34, K8.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

40.10 V27, K5.6. Standard Spray; Upright, Pendent and Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

Gas Station & C Store SECTION CWM Job No

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS

40.31 V34, K14.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

Norminal Sprinkler Temperature Rating

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

B. Section Identification for Fire Suppression Piping and Equipment.

SECTION WET-PIPE SPRINKLER SYSTEMS

Standard response. elo sprinklers

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

SECTION WET FIRE SPRINKLER SYSTEMS

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

standard response/ quick response extended coverage

DISCONTINUED PRODUCT

40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE

A. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure.

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

Non-Storage / Special Protection / Storage Sprinklers

Norminal Sprinkler Temperature Rating

SPRINKLERS TABLE OF CONTENTS

Residential Sprinkler For Sloped Ceilings

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

Refer to the specific sprinkler or spray nozzle technical data pages for sprinkler listings and approvals.

40.50 V38, K5.6. Adjustable Concealed Standard Spray Pendent Standard and Quick Response

quick response horizontal sidewall sprinkler vk360 (K8.0)

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

TECHNICAL DATA. Viking Technical Data may be found on. The Viking Corporation s Web site at.

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

A. All Fire Suppression System design and installation shall comply with the most current and adopted version of NFPA 13.

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

standard/quick response extended coverage light and ordinary hazard elo sprinklers

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

40.11 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

quick response Sprinkler 105a October 25, 2010

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

Microfast quick response Fusible element hsw sprinkler

DISCONTINUED PRODUCT. reference publication

Sprinkler Guards Model C Model D

SPRINKLER HEAD. Vertical Sidewall Sprinkler MODEL: SD2133, SD2121 DESCRIPTION MAXIMUM COVERAGE TECHNICAL SPECIFICATION SPRINKLER OPERATION RATINGS

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

S p e c i a l P u r p o s e S p r i n k l e r s. Attic Spaces Retail Windows High Security Institutions Minimal Water Damage Conditions

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

Environmental Health & Safety

standard response large orifice dry

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

A sprinkler operates automatically when the heat-actuated element is heated to, or above, its thermal rating.

B. Related Sections: The following Sections contain requirements that relate to this Section.

mirage standard response concealed pendent sprinkler vk492 (K5.6)

TECHNICAL DATA. Page 1 of 6

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

Model F1 FR56 Recessed. Quick Response Standard Spray. Bulletin 014 Rev. G OJ

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SPRINKLER HEAD. Upright, Pendent & Recessed Pendent Sprinklers MODEL: SD1010, SD1015, SD1030, SD1032 DESCRIPTION TECHNICAL SPECIFICATION

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

Transcription:

_specialties:pcsectiond_new 2/6/2012 4:46 PM Page -36 36 SECTIon Specialties Quality, Durability, Reliability FIrE ProTECTIon In addition to our plumbing business, LYNCAR has been a leading supplier to the Canadian fire protection industry for over 40 years. LYNCAR provides fire protection wholesalers with thousands of products including: Escutcheons and wallplates A full line of GLOBE sprinkler heads Sprinkler gauges Signage and labels for fire protection systems Beam clamps, ring hangers and other pipe-hanging accessories for sprinkler systems Electrical items such as Potter switches Fire-rated specialty chemicals such as pipe sealants and premixed anti-freeze Specialty valves Head guards Many other fire sprinkler specialties Please contact our order desk or check our website for more information on how we may serve your customers fire protection needs, or to get our fire protection wholesale catalogue.

_specialties:pcsectiond_new 2/6/2012 4:46 PM Page -37 The BEST Plumbing Specialties. One Source. 37 SPrInKLEr heads SPrInKLEr heads STAnDArD response 1/2 IPS G566115501 G56015502 - Temperature rating 155º - 5mm glass bulb sprinklers 1/2 orifice x 1/2 NPT - K FACTOR 5.6 - culus & FM approved G565115502 G566115501 G567015502 G565115502 SPrInKLEr heads QUICK response 1/2 IPS Upright - 1/2 IPS brass Horizontal sidewall - 1/2 IPS chrome Pendent - 1/2 IPS chrome G561515501 G562615502 - Temperature rating 155º - 3mm glass bulb sprinklers 1/2 orifice x 1/2 NPT - K FACTOR 5.6 - culus & FM approved G560115502 G561515501 G562615502 G560115502 Upright - 1/2 IPS brass Horizontal sidewall - 1/2 IPS chrome Pendent - 1/2 IPS chrome

_specialties:pcsectiond_new 2/6/2012 4:46 PM Page -38 38 SECTIon head ConCEALED, S.r. & Q.r. ThE InCh Specialties Quality, Durability, Reliability SPrInKLEr heads - Water working pressure rating 175 PSI - Factory tested hydrostatically to 500 PSI - Maximum low temperature glass bulb rating is -67ºF (-55ºC) - Strong wrap around pin, drop in design - Available in 155º - White plate 2-3/4 diameter - culus and FM approved G560615501W G565315501W Quick Response Standard Response residential ThE InCh - Water working pressure rating 175 PSI - Factory tested hydrostatically to 500 PSI - Maximum low temperature glass bulb rating is -67ºF (-55ºC) - Strong wrap around pin, drop in design - Available in 155º - White plate 2-3/4 diameter - culus and FM approved G490615501W Residential residential SPrInKLEr head 1/2 IPS - 3mm frangible glass bulb - Residential sprinklers are the ultimate in life safety and fire control - Install in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direction of the approving authorities having jurisdiction. - Temperature rating 0 155º F (68º C) - Water working pressure rating 175 PSI - Chrome pendent 155º - culus approved G561015502 Pendent, K FACTOR 5.6

_specialties:pcsectiond_new 2/6/2012 4:46 PM Page -39 The BEST Plumbing Specialties. One Source. 39 recessed ESCUTChEon SPrInKLEr - Recessed escutcheon for pendent sprinkler head - Chrome or white standard - Also available in black & brass - Sprinkler head sold separately FInISh IPS 205200 Chrome 1/2 205215 Chrome 3/4 205210 White 1/2 205225 White 3/4 ESCUTChEon recessed ThrEADED 2 PC PLATE - Made to allow for minor adjustments to pipe or ceiling pitch - Can be removed or reinstalled, allowing access above removable ceiling panels without shutting down the sprinkler system - Threaded skirt & cup for 1/2 adjustment 205213 Chrome 205214 White ESCUTChEon recessed retrofit - 3 piece recessed escutcheon - Centre section splits into 2 pieces and snap together - Chrome plated escutcheon without shutting down the system 205200r Chrome, 1/2 IPS STAnDArD ESCUTChEon 1 PC - Standard Escutcheon for pendent sprinkler head. - Chrome or White standard. FInISh IPS 205100 Chrome 1/2 205105 Chrome 3/4 205110 White 1/2 205105W White 3/4 oversized repair PLATE - Increase the coverage area when using 2 pc recessed plates or 1 pc plates - Used in repair when hole is oversized from previous sprinkler - Also suitable for earthquake zone areas where 1 is required for the flange - Total coverage is 5 - Sprinkler head sold separately 205301 Chrome 205302 White

_specialties:pcsectiond_new 2/6/2012 4:46 PM Page -40 40 SECTIon Specialties Quality, Durability, Reliability SPrInKLEr head CABInETS - LYNCAR stocks spare head cabinet for 6 or 12 heads - Sprinkler head sold separately 305621 6 head box 305619 12 head box head GUArDS 305660 305699 305675 305692 ESCUTChEon retrofit nipples ChEATEr BrASS hex - LYNCAR stocks many different head guards for fire sprinkler applications STYLE 305660 Red 1 pc 2 hook 1/2 or 3/4 IPS 305675 Red 2 pc heavy duty 1/2 IPS 305690 Red 1 pc 2 hook with shield 305692 Mini guard chrome for 1/2 or 3/4 IPS 305699 Head guard for recessed plate - These rings are used to conceal oversized holes and cutting errors in ceiling tiles, drywall or other ceiling materials - These products split so the system does not have to be shut down or the sprinkler head removed. The 1-1/2" ID is standard and the 2-1/2" ID is for semi recessed escutcheons - 4" coverage FInISh ID od 205240 White - Kydex 1-1/2 4 205242 White - Kydex 2-1/2 4-1/2 IPS brass cheater nipples, used when the sprinkler head requires adjustment down from the existing position ADUSTMEnT 205623 1/2 205624 3/4 205625 1 205626 1-1/2 205627 2 order Desk: (800) 263 7011 lyncar.com 24 hr. order Fax: (800) 459 6227

_specialties:pcsectiond_new 2/6/2012 4:46 PM Page -41 The BEST Plumbing Specialties. One Source. 41 PoTTEr FLoW & PrESSUrE SWITChES SWITCh PoTTEr FLoW - Potter flow switch - Paddle type flow switch - Available from 1 to 10 pipe sizes - Service pressure to 450 PSI, - ULC and FM approved SIZE 4070112 1/2-2 4070200 2 4070300 3 4070400 4 4070600 6 SWITCh PoTTEr PrESSUrE ** Also available as double contact models SWITCh PoTTEr osy & PCvS - Potter pressure switches - Single & double contacts - ULC and FM approved 4071102A Low pressure double contact (PS10-2A) 407110 Low pressure single contact (PS10) 407140 Air pressure single contact (PS40) ** 4071120 Pressure supervision switch (PS120) ** - Potter OSY & PCVS supervisory switches are double contact switches, for OSY valves or for PIB valves - FM approved part#404072 - OSY part#404073 - PCVS 404072 OSY 404073 PCVS order Desk: (800) 263 7011 lyncar.com 24 hr. order Fax: (800) 459 6227