GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

Similar documents
GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

Duct Cable GYTS-144B1.3

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

HELKAMA. Optical Fibre Cables

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Ø 1000 * 588 mm 50 kg

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Fibre Optic Cable. Catalogue.

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Fiber Optic Distribution Cables (6-144 Fibers)

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Fibre optic media options and trends

Fibre Specification Standards

Special Provision No. 683S28 December 2017

industry solutions: military

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

SPECIAL ELECTRICAL AND OPTICAL CABLES

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

Fiber Optics for Todays Industry Applications

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

Fibre (TIA) Field Test Specification

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Compact Module. Category 6A FTP Cabling System 1.1

DNVGL-CP-0402 Edition February 2016

STAND OUT FROM THE CROWD. Bisham Abbey, 14th May 2002 INTRODUCTION. Work Smart FIA. The Fibreoptic Industry Association STAND OUT FROM THE CROWD

FIRE RESISTANT CABLES

Hands-On CAT 5/6 & Fiber Optic Installer

STANDARD CONFORMANCE

MT-RJ Optical Fiber System Field Testing

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO

Clearlite Photonic Fibers

Fiber Optic Patch Cord and Pigtails

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Basic Professional Fiber Optic Installation

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

CATEGORY 6A FTP RJ45 SOLUTION

Caledonian Flame Retardant Coaxial Cables

Fibre Optic Basics FIA Summer Seminar 2014

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

ENHANCED FIRE PERFORMANCE CABLE

Catalogue Telecommunication Cables INTRODUCCIÓN

Communication Solutions for Energy Generation, Transmission and Distribution

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

FiberExpress Solutions

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

Telephone and Data Structured Wiring

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Certified Fibre Optic Specialist - Testing

Qualification Test Report LC Duplex Adapter For LC Cutouts

Main features of the JETnet system

This document is a preview generated by EVS

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Multi-Core Fire Resistant Cable

Detection of Solvents using a Distributed Fibre Optic Sensor

infrastructure for 10, 40 and 100Gbits/s readiness

Field Test Procedure for Optical Fibre Link Measurements

PRODUCT CATALOGUE Norröna

FIRE PERFORMANCE CABLE

Product Catalogue. External Management

SECTION COMMUNICATIONS FIBER CABINETS, ADAPTERS AND CONNECTORS

Reinforced FBG Sensors Serve Demanding Applications

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Fibre Solutions for Harsh Environments

Characterization of High Speed Optical Detectors for Purpose of OM4 Fibre Qualification: Selective Mode Detection

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description

High Performance LSZH Fire Resistant Cable

Transcription:

GOF Indoor and Outdoor Cables Documentation VWL 064.503 Version 1.1 Source Code M

GOF Installation Cables Cable matrix / overview Source code M Use Indoor In- / Outdoor Outdoor Type of cable Breakout Mini- Breakout Central Loose Tube Stranded Loose Tube Central Loose Tube Stranded Loose Tube Central Loose Tube CST I-V(ZN)HH I-V(ZN=B)H I/A-DQ(ZN=B)H I/A-DQ(ZN=B)H A-DQ(ZN)B2Y A-DQ(ZN)B2Y A-D(ZN)W2Y Stranded Loose Tube CST A-DF(ZN) 2YW2Y Stranded Loose Tube ADSS A-DF(ZN) 2YQ(ZN)2Y Fiber count 4-12 2-24 4 12 2 x 12 12-144 2-24 12-144 4-24 12-96 12-96 General Outer sheath LSZH LSZH LSZH LSZH LLDPE MDPE MDPE MDPE HDPE Sheath color green green green green black black black black black Armouring Aramid Glass yarn Glass yarn Glass yarn Glass yarn Glass yarn Corrugated steel Corrugated steel Water retardant yarn Application Laying procedure Termination Rodent Protection - + + + ++ ++ +++ +++ - Tertiary cabling Building backbone Campus backbone WAN Trunking Ducts, Trays Building riser raised floor Empty tube Ducts Directly in the ground Blowing On site termination Splicing VARIOline VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

Colour code fibers Breakout and loose tube cables Tube 1 (Blue) Tube 2 (orange) Fiber FOTAG IEEE 802.8 Fiber FOTAG IEEE 802.8 1 blau 13 blau 2 orange 14 orange 3 grün 15 grün 4 braun 16 braun 5 grau 17 grau 6 weiss 18 weiss 7 rot 19 rot 8 schwarz 20 schwarz 9 gelb 21 gelb 10 violett 22 violett 11 rosa 23 rosa 12 türkis 24 türkis Stranded loose tube cables Fiber colour 1 red 2 blue 3 green 4 yellow 5 violet 6 white 7 orange 8 grey 9 brown 10 black 11 turquoise 12 pink The max. fibercount per loose tube is limited to 12 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Breakout Cables I- V (ZN) HH / D03-050714 Indoor cables Fiber count 4-12 Enhanced fire resistance Number code for individual breakout identification Suitable for direct connector fitting UV stabilized LSZH sheath (color green) Wrapping LSOH sheath LSOH sheath Aramid yarn 900 µm Vollader Fiber count 4 6 8 12 Nominal cable Ø (mm) 6.6 7.6 9.3 9.7 Nominal weight (kg/km) 46 58 88 95 Maximum tensile strength (N) during installation 700 1100 1400 2200 IEC 60794-1-2 E1 in operation 180 280 370 560 IEC 60794-1-2 E1 Minimum bending radius (mm) static 70 80 95 100 IEC 60794-1-2 E11 Dynamic 80 95 115 120 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 2500 2500 2500 2000 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 30 up to plus 70 IEC 60794-1-2 F1 during installation minus 5 up to plus 50 IEC 60794-1-2 F1 in operation minus 10 up to plus 60 IEC 60794-1-2 F1 Heat of combustion (MJ/km) 870 1100 1300 1800 Properties in case of fire IEC 60332-1 IEC 60332-3C IEC 61034 IEC 60754-2 Outer sheath color Green (RAL6017/6018) Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 4 R314459 R314466 R314473 R314480 6 R314460 R314467 R314474 R314481 8 R314239 R314240 R314241 R314248 12 R314242 R314243 R341244 R314249 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Mini Breakout Cables I- V (ZN=B) H / D12-050714 Indoor cables Fiber count 2-24 Good fire resistance Glass yarn strength members Suitable for direct connector fitting UV stabilized LSZH sheath (color green) LSOH sheath Glass yarn 900 µm tight buffered fibre Fiber count 2 / 4 6 8 12 16 24 Nominal cable Ø (mm) 6.6 6.6 6.6 6.6 7.6 9 Nominal weight (kg/km) 22/25 28 33 41 51 71 Maximum tensile strength (N) during installation 500 800 800 800 1400 1600 IEC 60794-1-2 E1 in operation 130 190 250 250 320 500 IEC 60794-1-2 E1 Minimum bending radius (mm) Static 50 50 60 70 80 90 IEC 60794-1-2 E11 Dynamic 60 60 70 80 90 100 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 2000 2000 2000 2000 2000 2000 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 30 up to plus 70 IEC 60794-1-2 F1 during installation minus 5 up to plus 50 IEC 60794-1-2 F1 in operation minus 10 up to plus 60 IEC 60794-1-2 F1 Heat of combustion (MJ/km) 320 a) 460 540 720 920 1300 Properties in case of fire IEC 60332-1 IEC 61034 IEC 60754-2 Outer sheath color Green (RAL6017/6018) a) Heat of combustion with 4 Fibers is 380 MJ/km Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 2 R314486 R314488 R314490 R314492 4 R304081 R304073 R308315 R304135 6 R304082 R304074 R308316 R304136 8 R304083 R304075 R308313 R304137 12 R304084 304076 R308318 R304138 16 R314487 R314489 R314491 R314493 24 R304086 R304078 R308317 R304140 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Central Loose Tube Cables I/A- DQ (ZN=B) H / E14-051006 Indoor as well as outdoor use Central loose tube with 4-24 fibers (24 fibers is a bitube cable) Individually color coded fibers for identification Slight rodent protection through reinforced glass yarn UV stabilized LSZH sheath (color green) Swellable glass yarn LSOH sheath Waaterproof gel Central loose tuber fibre MM/SM Fiber count 4 to 12 16 to 24 Nominal cable Ø (mm) 6.2 7.2 Nominal weight (kg/km) 41 53 Maximum tensile strength (N) during installation 1500 1800 IEC 60794-1-2 E1 in operation 320 320 IEC 60794-1-2 E1 Short time tensile strength (N) some days???? IEC 60794-1-2 E1 Minimum bending radius (mm) static 65 75 IEC 60794-1-2 E11 dynamic 75 85 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 1500 3000 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC 60794-1-2 F1 during installation minus 5 up to plus 50 IEC 60794-1-2 F1 in operation minus 40 up to plus 70 IEC 60794-1-2 F1 Heat of combustion (MJ/km) 540 860 Minimum Kink diameter (mm) 60 IEC 60794-1-2 E10 Water penetration Compliant IEC 60794-1-2 F5B Properties in case of fire IEC 60332-1 IEC 61034 IEC 60754-2 Outer sheath color Green (RAL6017/6018) Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 4 R304093 R304088 R308217 R304143 6 R304094 R304089 R308310 R304145 8 R304095 R304090 R308218 R304146 12 R304096 R304091 R308214 R304147 2 x 12 R304097 R304092 R308215 R304148 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Stranded Loose Tube Cables I/A- DQ (ZN=B) H / N05-050720 Indoor as well as outdoor use Fiber count 12-144 (stranded loose tube) Excellent mechanical properties Water tight thanks to swelling tape Slight rodent protection through reinforced glass yarn UV stabilized LSZH sheath (color green) Strengthened yarn Central strength member Loose tube LSOH sheath Waaterproofing yarn Fiber count 12-72 96 144 Nominal cable Ø (mm) 12 13.6 17 Nominal weight (kg/km) 138 180 262 Maximum tensile strength (N) during installation 3500 3500 3500 IEC 60794-1-2 E1 in operation 700 700 700 IEC 60794-1-2 E1 Minimum bending radius (mm) static 120 140 170 IEC 60794-1-2 E11 dynamic 150 170 210 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 2500 2500 2500 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC 60794-1-2 F1 during installation minus 5 up to plus 50 IEC 60794-1-2 F1 in operation minus 40 up to plus 70 IEC 60794-1-2 F1 Heat of combustion (MJ/km) 2800 3300 4700 Minimum Kink diameter (mm) 100 IEC 60794-1-2 E10 Water penetration compliant IEC 60794-1-2 F5B Properties in case of fire IEC 60332-1 IEC 61034 IEC 60754-2 Outer sheath color Green (RAL6017/6018) Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 1 x 12 314494 314501 314507 314513 2 x 12 314495 314502 314508 314514 4 x 12 314497 314503 314509 314515 6 x 12 314498 314504 314510 314516 8 x 12 314499 314505 314511 314517 12 x 12 314500 314506 314512 314518 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Central Loose Tube Cables Rodent Protection A- DQ (ZN) B2Y / E08-051006 Source code : M Outdoor cables Central loose tube with 4-24 fibers Individually color coded fibers for identification Glass yarn rodent protection UV stabilized LLDPE sheath (color black) Glass yarn Waterproof gel Central loose tube Polyethylene sheath Fiber count 4 to 12 16 to 24 Nominal cable Ø (mm) 6.3 7.5 Nominal weight (kg/km) 32 44.5 Maximum tensile strength (N) during installation 1500 1500 IEC 60794-1-2 E1 in operation 320 320 IEC 60794-1-2 E1 Minimum bending radius (mm) static 100 100 IEC 60794-1-2 E11 dynamic 100 100 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 1500 1500 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC 60794-1-2 F1 during installation minus 5 up to plus 50 IEC 60794-1-2 F1 in operation minus 20 up to plus 60 IEC 60794-1-2 F1 Minimum Kink diameter 60 IEC 60794-1-2 E10 Water penetration Compliant IEC 60794-1-2 F5B Outer sheath color Black (RAL9005/9004) Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 4 R314519 R314521 R314523 R314525 6 R312789 R312791 R312792 R312797 8 R314520 R314522 R314524 R314526 12 R304153 R304150 R311387 R304156 24 R304154 R304151 R311388 R304157 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Stranded Loose Tube Cables Rodent Protection A- DQ (ZN) B2Y / H08-041117 Outdoor cables Fiber count 12-144 (stranded loose tube) Excellent mechanical properties Water tight thanks to swelling tape Glass yarn rodent protection UV stabilized MDPE sheath (color black) Central strength Central loose tube swellable glass yarn strengthened glass yarn Polyethylene sheath Fiber count 12-72 96 144 Nominal cable Ø (mm) 12 13.6 17 Nominal weight (kg/km) 112 149 222 Maximum tensile strength (N) during installation 3500 3500 3500 IEC 60794-1-2 E1 in operation 700 700 700 IEC 60794-1-2 E1 Minimum bending radius (mm) static 180 200 250 IEC 60794-1-2 E11 dynamic 180 200 250 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 3000 3000 3000 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC 60794-1-2 F1 during installation minus 5 up to plus 50 IEC 60794-1-2 F1 in operation minus 40 up to plus 70 IEC 60794-1-2 F1 Minimum Kink diameter (mm) 100 IEC 60794-1-2 E10 Water penetration Compliant IEC 60794-1-2 F5B Outer sheath color Black (RAL9005/9004) Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 1 x 12 314527 314532 314537 314542 2 x 12 314528 314533 314538 314451 4 x 12 304155 304152 311389 304158 6 x 12 314529 314534 314539 314452 8 x 12 314530 314535 314540 314453 12 x 12 314531 314536 314541 314454 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Central Loose Tube Cables Steel-Armored A- D (ZN) W2Y / E06-050719 Outdoor cable for application in harsh conditions Central loose tube with 4-24 fibers Individually color coded fibers for identification Reinforced rodent protection with corrugated steel CST UV stabilized MDPE sheath (color black) fiber Central loose tube Waterproof gel swellable aramid yarn Corrugated steel tape Polyethylene sheath Fiber count 4 to 12 16 to 24 Nominal cable Ø (mm) 8.2 9.7 Nominal weight (kg/km) 100 120 Maximum tensile strength (N) during installation 1200 1300 IEC 60794-1-2 E1 in operation 250 300 IEC 60794-1-2 E1 Minimum bending radius (mm) static 170 180 IEC 60794-1-2 E11 dynamic 170 180 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 4000 4000 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC 60794-1-2 F1 during installation minus 5 up to plus 50 IEC 60794-1-2 F1 in operation minus 40 up to plus 70 IEC 60794-1-2 F1 Minimum Kink diameter (mm) 250 IEC 60794-1-2 E10 Outer sheath color Black (RAL9005/9004) Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 4 312796 312795 312794 312793 2 x 4 314455 314456 314457 314543 12 304213 304210 311390 304216 2 x 12 304214 304211 311391 304217 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Stranded Loose Tube Cables Steel-Armored A- DF (ZN) 2YW2Y / I07-050720 Outdoor cable for direct ground installations Fiber count 12-96 (stranded loose tube) Water tight cable core Reinforced rodent protection with corrugated steel CST UV stabilized MDPE sheath (color black) Central Loose tube Waterproof glass yarn Currugated steel tape polyethylene sheath Fiber count up to 72 up to 96 Nominal cable Ø (mm) 15.6 16.9 Nominal weight (kg/km) 223 300 Maximum tensile strength (N) during installation 3000 3000 IEC 60794-1-2 E1 in operation 600 600 IEC 60794-1-2 E1 Minimum bending radius (mm) static 250 280 IEC 60794-1-2 E11 dynamic 250 280 IEC 60794-1-2 E11 Compressive strength (N/10cm) permanent 4500 4500 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC 60794-1-2 F1 during installation minus 5 up to plus 50 IEC 60794-1-2 F1 in operation minus 40 up to plus 70 IEC 60794-1-2 F1 Minimum kink diameter (mm) 150 IEC 60794-1-2 E10 Water penetration Longitudinally water tight IEC 60794-1-2 F5B Outer sheath color Black (RAL9005/9004) IEC 60794-1-2 F5B Order information Number of fiber Part number 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 1 x 12 R314544 R314548 R314552 R314556 2 x 12 R314545 R314549 R314553 R314557 4 x 12 R304215 R304212 R311392 R304218 6 x 12 R314546 R314550 R314554 R314558 8 x 12 R314547 R314551 R314555 R314559 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Stranded Loose Tube Cables Aerial ADSS A- DF (ZN) 2Y Q (ZN) 2Y / O04A-020603 Dielectric aerial cables ADSS Fiber count 12-96 (stranded loose tube) Water tight cable core Suitable for all standard span equipment High-voltage resistance of up to 132kV UV resistant HDPE sheath (color black) Central strength member Loose tube Water retardant yarns Polyethylene sheath Fiber count / loose tubes Up to 72 Up to 96 Nominal cable Ø (mm) 16.8 18.1 Nominal weight (kg/km) 255 291 Maximum pulling force (N) 12000 13000 IEC 60794-1-2 E1 Crush resistance (N/cm) 450 IEC 60794-1-2 E1 Standard packaging 2.1, 4.2, 6.1, 8.2 km drum IEC 60794-1-2 E11 Compressive strength (N/10cm) 4500 4500 IEC 60794-1-2 E3 Temperature range ( C) in storage minus 40 up to plus 70 IEC 60794-1-2 F1 during installation minus 5 up to plus 50 IEC 60794-1-2 F1 in operation minus 40 up to plus 70 IEC 60794-1-2 F1 Aussenmantelfarbe schwarz (RAL9005/9004) Bestellinformation Anzahl Fasern Artikelnummer 62,5/125 µm (OM1) 50/125 µm (OM2) 50/125 µm (OM3) 9/125µm (OS1;G652.D) 1 x 12 314560 314565 314570 314575 2 x 12 314561 314566 314571 314576 4 x 12 314562 314567 314572 314577 6 x 12 314563 314568 314573 314578 8 x 12 314564 314569 314574 314579 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Installation Cables FO cable marking / 300306 R&Mfreenet <Sheath> <DIN> <n> x <m> <Fiber> <Category> <Spec> <Manf. Ref.> <source code> <Meter marking> Digit Description <Sheath> Outer sheath material <DIN> Cable type designation based on DIN VDE 0888 <n> <m> <Fiber> A = outdoor cable I = indoor cable V = 900µm tight buffer fibre D = loose tube with jelly filling Q = swelling tape / swell able glass yarn F = water blocked cable core Y = PVC Number of tubes if loose tube cable Number of fibers (per tube if loose tube) Fiber type ZN = glass yarn reinforcement B = non-metallic rodent protection 2Y = outer sheath PE H = outer sheath halogen free (LSZH) HH = halogen free breakout cable (LSZH) W = corrugated steel armouring 11Y = Polyurethane G50/125 = 50/125µm multimode fiber H200/230 = 200/2300 polymer cald fiber (PCF) G62.5/125 = 62.5/125µm multimode fiber P980/1000 = 980/1000 polymer optical fiber (POF) E9/125 = E9/125µm singlemode fiber <Category> Fiber category according ISO/IEC 11801:2002 <Spec> Source code <Manf. Ref.> <Meter marking> OM1 / OM2 / OM3 = multimode fiber OH1 = PCF OS1(G.652.D) = singlemode fiber OP1 = POF Single fiber specification according datasheet Manufacturer. The logic is: if MM (GOF) fibre Attenuation / window / bandwidth Example for OM3: 3.0B1500 1.0F500 Attenuation is 3.0dB/km @ 850nm and 1.0dB/km @1300nm bandwidth is 1500Mhz km @ 850nm and 500Mhz km @ 1300nm if SM fibre Attenuation / window / chrom. dispersion Example for OS1: 0.39F3 0.25H18 Attenuation is 0.39dB/km @ 1310nm and 0.25dB/km @1550nm Chrom. dispersion is 3ps/km nm @1310nm and 18ps/km nm @1550nm if PCF or POF Not applicable M Number index for the traceability Cable is produced with a meter marking VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Installation Cables Sheathing material / B05 LLDPE, black This is the alternative PE material for cables for outdoor use. The material is UV stabilised using 2.5 ± 0.5 % carbon black and have excellent weathering resistance. The LLDPE material is used for UNI tube cables and when specified according to customer request. The LDPE meets the requirements of a number of national and international standards: ISO 1872-PE, KCHL, 18 - D003 ANSI C 8.35 ASTM D1248-84: Type I, Class C, Cat 5, grade J3, E5 BS 6234 03C, TS1 DIN VDE 0207 type 2YM2 NF C 32-060 The LLDPE fulfils the requirements of IEC 708-1 (test according to IEC 811) Corrugated steel tape armouring Corrugated steel tape armouring is used as rodent protection and as additional mechanical protection for outdoor cables for direct burial and for installation along railways and into sewers where the risk for rodent attack is high. Cables with corrugated steel tape and LDPE or HDPE jacket fulfils the requirements of: REA PE 90 (USA) As well as the requirements of several Railway administrations: Among them Banestyrelsen (Denmark), SNCF and RATP (France), BR (Great Britain). The steel tape is corrosion protected with a layer of chromium on both sides. The steel tape fulfils the requirements of: EN 10 202: 1989 ASTM A 657-87 The standard thickness of the steel tape is 0.155 mm ± 0.015 mm. Upon request tapes with a thickness of 0.250 mm may be supplied. There is a polymer film on both sides of the steel tape. The nominal thickness of the polymer film is 0.055 mm. The purpose of the polymer film is to ensure good adhesion between tape and outer (LDPE or MDPE) jacket and make the bonding of the overlap possible. The adhesion between steel tape and a polyethylene sheath is fulfilling the requirements of REA PE-90. A common trade name for this material is Zetabon. The steel tape is corrugated and folded over the cable core or an inner jacket. On top of the steel tape is extruded an outer polymer heath. Aramid yarns Aramid yarns are used as strength member for cables with tight buffered fibres, some cables with semi tight fibres and for UNI tube cable. Aramid yarns are also used in loose tube cables with central strength member as additional tensile reinforcement. There are no international or national standards for Aramid yarns. The most common trade names for Aramid yarns are Twaron and Kevlar. The tensile strength requirement for the cable determines the amount of Aramid yarn to be used. Glass yarns Glass yarns in the form of roving s are used as alternative strength member for UNI tube cables. Glass yarns are also used in loose tube cables with central strength member as additional tensile reinforcement. Thick layers of glaziers have appeared to be a good rodent protection scheme, however not as effective as steel armouring. VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Multi Mode Fiber 62.5/125 µm (OM1) / C02-060102 General information This fibre is a graded-index multimode fibre suitable for transmission speeds of up to 10 Gb/s. It has a 62.5 µm core diameter and a 125 µm cladding diameter. The fibre is designed for use at 850 and/or 1300 nm. This fibre is suitable for use in premises wiring application like LAN s with video, data and or voice services using LED, VCSEL and Fabry- Perot laser sources. The fibre is compliant with all relevant network standards. Specification Standards and norm Core Coating Optical properties This fibre fulfils the requirements of: IEC 60793-2-10 Category A1b; EN 60793-2-10: type A1b TIA/EIA-492AAAA Testing methods are in accordance with the following standards: IEC 60793-1-XX:2002 EN 60793-1-XX:2002 When cabled, the fibres fulfil the requirements for use in a number of cabling systems, among them are: EN 50 173:2002 category OM1. ISO/IEC 11801:2002 category OM1 IEEE 802.3-2002 with amendment 802.3ae - 2002. ANSI/TIA/EIA-568-B.3-2000 ANSI X3.166-1990 IEC 9314-3 IBM Fibre Optic Channel Links; ESCON The core is germanium doped. Dual layer UV curable acrylate, type DLPC9. The coating offers excellent stable stripping performance, and a unique high and stable value for the dynamic stress corrosion coefficient. This gives a greatly improved mechanical protection of the fibre when used in harsh environments. Attenuation (of cable with fibres): Numerical aperture: 0.275 ± 0.015. At 850 nm: 3.2 db/km In homogeneity of OTDR trace for any two At 1300 nm: 0.9 db/km 1000 metre fibre lengths: Max.: 0.2 db/km. Bandwidth (OFL): At 850 nm: At 1300 nm: Dimensional and mechanical properties 200 MHz km 500 MHz km Group index of refraction: At 850 nm 1.497 At 1300 nm: 1.491 Core diameter (µm) 62.5 ± 3.0 IEC/EN 60793-1-20 Cladding diameter (µm) 125 ± 2.0 IEC/EN 60793-1-20 Cladding non-circularity (%) 2 IEC/EN 60793-1-20 Core non-circularity (%) 6 IEC/EN 60793-1-20 Core-cladding concentricity error (µm) 3.0 IEC/EN 60793-1-20 Primary coating diameter - uncoloured (µm) 242 ± 7.0 IEC/EN 60793-1-21 Primary coating diameter - coloured (µm) 250 ± 15 IEC/EN 60793-1-21 Primary coating non-circularity (%) 5 IEC/EN 60793-1-21 Primary coating-cladding concentricity error (µm) 10.0 IEC/EN 60793-1-21 Proof stress level (GPa) 0.69 ( 1 %) IEC/EN 60793-1-30 Typical average strip force (N) 1.7 IEC/EN 60793-1-32 Strip force (peak) (N) 1.3 F peak.strip 8.9 IEC/EN 60793-1-32 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Multi Mode Fiber 50/125 µm (OM2) / C01-060102 Source Code:M General information This fibre is a graded-index multimode fibre suitable for transmission speeds of up to 10 Gb/s. It has a 50 µm core diameter and a 125 µm cladding diameter. The fibre is designed for use at 850 and/or 1300 nm. This fibre is suitable for use in premises wiring application like LAN s with video, data and or voice services using LED, VCSEL and Fabry- Perot laser sources. The fibre is compliant with all relevant network standards. Specification Standards and norm Core Coating Optical properties This fibre fulfils the requirements of: IEC 60793-2-10 Category A1a; EN 60793-2-10: type A1a ITU Recommendation G.651 TIA/EIA-492AAAB Testing methods are in accordance with the following standards: IEC 60793-1-XX:2002 EN 60793-1-XX:2002 When cabled, the fibres fulfil the requirements for use in a number of cabling systems, among them are: EN 50 173:2002 category OM2. ISO/IEC 11801:2002 category OM2 IEEE 802.3-2002 with amendment 802.3ae - 2002. ANSI/TIA/EIA-568.B.3-2000 This fibre may be used as an alternative for 62.5 µm fibre according to: ANSI X3.166-1990 and IEC 9314-3 The core is germanium doped. Dual layer UV curable acrylate, type DLPC9. The coating offers excellent stable stripping performance, and a unique high and stable value for the dynamic stress corrosion coefficient. This gives a greatly improved mechanical protection of the fibre when used in harsh environments. Attenuation (of cable with fibres): Numerical aperture: 0.20 ± 0.02. At 850 nm: 2.7 db/km In homogeneity of OTDR trace for any two At 1300 nm: 0.7 db/km 1000 metre fibre lengths: Max.: 0.2 db/km. Bandwidth (LED): At 850 nm: At 1300 nm: Dimensional and mechanical properties 600 MHz km 1200 MHz km Group index of refraction: At 850 nm 1.482 At 1300 nm: 1.480 Core diameter (µm) 50 ± 3.0 IEC/EN 60793-1-20 Cladding diameter (µm) 125 ± 2.0 IEC/EN 60793-1-20 Cladding non-circularity (%) 2 IEC/EN 60793-1-20 Core non-circularity (%) 6 IEC/EN 60793-1-20 Core-cladding concentricity error (µm) 3.0 IEC/EN 60793-1-20 Primary coating diameter - uncoloured (µm) 245 ± 1.0 IEC/EN 60793-1-21 Primary coating diameter - coloured (µm) 250 ± 15 IEC/EN 60793-1-21 Primary coating non-circularity (%) 5 IEC/EN 60793-1-21 Primary coating-cladding concentricity error (µm) 10.0 IEC/EN 60793-1-21 Proof stress level (GPa) 0.69 ( 1 %) IEC/EN 60793-1-30 Typical average strip force (N) 1.2 IEC/EN 60793-1-32 Strip force (peak) (N) 1.3 F peak.strip 8.9 IEC/EN 60793-1-32 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Multi Mode Fiber 50/125 µm (OM3) / C11-060102 Source code:m General information This fibre is a graded-index multimode fibre optimised for 10 Gb/s transmission speeds. It has a 50 µm core diameter and a 125 µm cladding diameter. The fibre is designed for use at 850, but can also be used at 1300 nm. The fibre is compliant with all relevant network standards. Range for 1000BASE SL: 1000 m Range for 10GBASE SX: 300 m Specification Standards and norm Core Coating Optical properties Dimensional and mechanical properties This fiber exceeds the requirements of: IEC 60793-2-10; Category A1a.2; EN 60793-2-10; Category A1a.2; ITU Recommendation G.651 TIA/EIA-492AAAC Testing methods are in accordance with the following standards: IEC 60793-1-XX:2002 EN 60793-1-XX:2002 FOTP-220 (DMD) The core is germanium doped. When cabled, the fibers fulfil the requirements for use in a number of cabling systems, among them are: EN 50173:2002 category OM3. ISO/IEC 11801:2002 category OM3. IEEE 802.3 2002 with amendment 802.3ae 2002. Dual layer UV curable acrylate, type DLPC9. The coating offers excellent stable stripping performance, and a unique high and stable value for the dynamic stress corrosion coefficient. This gives a greatly improved mechanical protection of the fibre when used in harsh environments. Attenuation (of cable with fibres): Bandwidth (LED): At 850 nm: 2.7 db/km At 850 nm: 1500 MHz km At 1300 nm: 0.7 db/km At 1300 nm: 500 MHz km Fibre attenuation (for reference only) Bandwidth (RML): At 850 nm: 2.5 db/km At 850 nm 2000 MHz km At 1300 nm: 0.7 db/km Numerical aperture: 0.200 ± 0.015. In homogeneity of OTDR trace for any two 1000 metre fibre lengths: Max.: 0.1dB/km. Group index of refraction: At 850 nm 1.482 At 1300 nm: 1.480 Core diameter (µm) 50 ± 3 IEC/EN 60793-1-20 Cladding diameter (µm) 125.0 ± 2.0 IEC/EN 60793-1-20 Cladding non-circularity (%) 2.0 IEC/EN 60793-1-20 Core non-circularity (%) 6 IEC/EN 60793-1-20 Core-cladding concentricity error (µm) 3.0 IEC/EN 60793-1-20 Primary coating diameter - uncoloured (µm) 242 ± 7 IEC/EN 60793-1-21 Primary coating diameter - coloured (µm) 250 ± 15 IEC/EN 60793-1-21 Primary coating non-circularity (%) 5 IEC/EN 60793-1-21 Primary coating-cladding concentricity error (µm) 12.5 IEC/EN 60793-1-21 Proof stress level (GPa) 0.69 ( 1 %) IEC/EN 60793-1-30 Typical average strip force (N) 1.2 IEC/EN 60793-1-32 Strip force (peak) (N) 1.2 F peak.strip 5 IEC/EN 60793-1-32 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

General information This enhanced Singlemode fibre provides improved performance across the entire 1260 nm to 1625 nm wavelength spectrum due to its low attenuation in 1383 nm the water-peak region. The fibre design is matched cladding. GOF Single Mode Fiber 9/125 µm (OS1, G.652.D) / C03e-060102 Specification Standards and norm Core Coating Optical properties Dimensional and mechanical properties This fibre fulfils the requirements of: IEC 60793-2-50 Category B.1.3 EN 60793-2-50: Class B1.3 ITU Recommendation G.652.D The older ITU designations A, B and C are also fulfilled. When cabled, the fibres fulfil the requirements for use in a number of cabling systems, among them is: EN 50 173-1: 2002, cat. OS1 + OS2 ISO/IEC 11801: 2002, cat. OS1 +OS2 IEEE 802.3-2002 incl. 802.3ae Testing methods are in accordance with the following standards: IEC 60793-1-XX: 2002 EN 60793-1-XX: 2002 The core is germanium doped. The fibre coating is dual layer UV curable acrylate. The fibre is coated using Draka Comteq s proprietary high quality coating systems. Attenuation (of cable with fibres): In the range 1310 nm - 1625 nm: 0.35 db/km At 1550 nm: 0.25 db/km In homogeneity of OTDR trace for any two 1000 metre fibre lengths Max.: 0.1 db/km Group index of refraction: At 1310nm: 1.467 At 1550nm: 1.4645 Cladding diameter (µm) 125.0 ± 1.0 IEC/EN 60793-1-20 Cladding non-circularity (%) 1.0 IEC/EN 60793-1-20 Core (MFD) non-circularity (%) 6 IEC/EN 60793-1-20 Core (MDF) -cladding concentricity error (µm) 0.6 IEC/EN 60793-1-20 Primary coating diameter - uncoloured (µm) 242 ± 7 IEC/EN 60793-1-21 Primary coating diameter - coloured (µm) 242± 7 IEC/EN 60793-1-21 Primary coating non-circularity (%) 5 IEC/EN 60793-1-21 Primary coating-cladding concentricity error (µm) 12.0 IEC/EN 60793-1-21 Proof stress level (GPa) 0.7 ( 1 %) IEC/EN 60793-1-30 Strip force (peak) (N) 1.3 Fpeak.strip 8.9 IEC/EN 60793-1-32 Chromatic dispersion coefficient: In the interval 1285 nm 1330 nm (ps/km nm) At 1550 nm (ps/km nm) At 1625 nm (ps/km nm) Zero dispersion wavelength, λ 0 (nm) Zero dispersion slope (ps/(nm 2 km)) Cut-off wavelength (λ c nm) Cut-off wavelength (λ cc nm) Mode field diameter at 1310 nm (µm) Mode field diameter at 1550 nm (µm) Macrobending loss at 1550 nm, 100 turns on a ø 60 mm mandrel (db) 2.8 17.0 22.0 13120± 10 0.090 High limit: 1330 Low limit: 1150 1260 9.0 ± 0.4 10.2 ± 1.0 IEC/EN 60793-1-42 IEC/EN 60793-1-44 IEC/EN 60793-1-45 0.05 IEC/EN 60793-1-47 Polarisation mode dispersion (PMD) coefficient, cabled (ps/ km) 0.2 IEC/EN 60793-1-48 PMD Q Link Design Value (ps/ km) 0.08 IEC/EN 60794-3 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Cabling Standards ISO/IEC 11801:2002 Fiber optic categories The category defines the performance of a cabling component components to verify the compliance components to design a link/channel values for performance comparison Multimode fiber 850nm 1300nm category core - Ø db/km Mhz km launch db/km Mhz km launch OM1 50µm & 62.5µm 3.5 200 over filled 1.5 500 over filled OM2 50µm & 62.5µm 3.5 500 over filled 1.5 500 over filled 3.5 1500 over filled OM3 50µm 1.5 500 over filled 3.5 2000 restricted Singlemode fiber 1310nm 1550nm category core - Ø db/km Mhz km db/km Mhz km OS1 9µm 1.00 N.A 1.00 N.A Fiber optic classes The class defines end to end performance of a link its supporting cabling design of networking equipment values for certification of the installation Channel attenuation limits Class OF-300 channel supporting application over a min. length of 300m Class OF-500 channel supporting application over a min. length of 500m Class OF-2000 channel supporting application over a min. length of 2000m Note: Multimode Singlemode 850nm 1300nm 1310nm 1550nm 2.55dB 1.95dB 1.80dB 1.80dB 3.25dB 2.25dB 2.00dB 2.00dB 8.50dB 4.50dB 3.50dB 3.50dB The total values include 1.5dB for connecting hardware. Additional connectors and splices may be used if the power budget of the application allows. Models of vertical (backbone) and horizontal optical fiber cabling In order to accommodate increase quantities of mated connections and splices used within a channel of a given class, the total length of the channel may have to be reduced to accommodate the additional attenuation. Spliced combined Direct combined Patched combined VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice

GOF Ethernet Applications Matrix ISO/IEC 11801:2002 / IEEE 802.3xx Applications according ISO/IEC 11801:2002 and EN 50173-1 (informative) Multimode Fast Ethernet 100Base-FX Gigabit Ethernet 1000Base-SX/LX 10Gbit Ethernet 10GBase-S 10Gbit Ethernet 10GBase-LX4 850nm 1300nm 850nm 1300nm 850nm 1300nm 850nm 1300nm OM1 N.A OF-2000 1) OF-500 N.A N.A N.A OF-300 OM2 N.A OF-2000 OF-500 OF-500 N.A N.A N.A OF-300 OM3 N.A OF-2000 OF-500 OF-500 OF-300 N.A N.A OF-300 Singlemode Gigabit Ethernet 1000Base-LX 10Gbit Ethernet 10GBase-LX4 10Gbit Ethernet 10GBase-L 10Gbit Ethernet 10GBase-E 1310nm 1550nm 1310nm 1550nm 1310nm 1550nm 1310nm 1550nm OS1 OF-2000 N.A OF-2000 N.A OF-2000 N.A N.A OF-2000 1) Maximum Length (Channel) according IEEE 802.3z (275m) Standardized applications according IEEE 802.3xx 62.5/125 (OM1) 50/125 (OM2) 50/125 (OM3) Note: 9/125 (OS1) Multimode Fast Ethernet 100Base-FX Gigabit Ethernet 1000Base-SX/LX 10Gbit Ethernet 10GBase-S 10Gbit Ethernet 10GBase-LX4 850nm 1300nm 850nm 1300nm 850nm 1300nm 850nm 1300nm Max. Length (m) N.A 2 000 275 550 33 N.A N.A 300 Max. IL (db) N.A 11.0 2.53 2.32 1.6 N.A N.A 2.0 Max. Length (m) N.A 2 000 550 550 82 N.A N.A 300 Max. IL (db) N.A 6 3.43 2.32 1.8 N.A N.A 2.0 Max. Length (m) N.A 2 000 550 550 300 N.A N.A N.A Max. IL (db) N.A 6 3.43 2.32 2.6 N.A N.A N.A The total values include 1.5 db for connecting hardware. Additional connectors and splices may be used if the power budget of the application allows. Singlemode Max. Length (m) Max. IL (db) Gigabit Ethernet 1000Base-LX 1310n m 10Gbit Ethernet 10GBase-LX4 10Gbit Ethernet 10GBase-L 10Gbit Ethernet 10GBase-E 1550nm 1310nm 1550nm 1310nm 1550nm 1310nm 1550nm 5 000 N.A 10 000 N.A 10 000 N.A N.A 40 000 4.5 N.A 6.2 N.A 6.2 N.A N.A 10.9 VWL 064.438-v2.0 GOF Indoor and Outdoor Cables - Changes without prior notice