MICRO GROW GREENHOUSE SYSTEMS, INC YNEZ RD., SUITE C-4, TEMECULA, CA PHONE (909) FAX (909) Revision 1.

Similar documents
MICRO GROW GREENHOUSE SYSTEMS, INC

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus

MICRO GROW GREENHOUSE SYSTEMS, INC YNEZ RD., SUITE C-4, TEMECULA, CA PHONE (909) FAX (909) Revision 1.

MICRO GROW. GREENHOUSE SYSTEMS, INC ZEVO DR., UNIT B-1, TEMECULA, CA PHONE (951) FAX (951)

Procom Greenhouse Control System

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

Growmaster Procom Precision Control, Multiple Zone Capability, Easy Operation

SC Installation, Operation & Application Guide

VX SERIES Wireless Thermostat with Occupancy Sensor

OWNER S MANUAL Venstar Inc. 08/07

Pump-Up Controller MODEL 4062

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

Pump-Down Controller MODEL 4052

Isolation Relay: If Needed. # 9. NO relay for TT To Thermostat NO relay. MZ308 Exquisite Heat Controller

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Installation Guide ULTRA-SAUNA HEATER. Proudly made in USA since 1964 MEDIUM HEATERS KW. Installation Instructions & User Manual

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

RATIO:GUARD Model E-1S EC Monitor

Installation Guide ULTRA-SAUNA HEATER. Proudly made in USA since 1964 SMALL HEATERS KW. Installation Instructions & User Manual

SC Installation, Operation & Application Guide

Your safety and the safety of others are very important.

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Installation, Start-Up, and Operating Instructions

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

7-Day. Digital Thermostat. residential. & 2-cool

SC Installation, Operation & Application Guide

WARNING Important Safety Information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Installation Guide ULTRA-SAUNA HEATER. Proudly made in USA since 1964 LARGE HEATERS KW. Installation Instructions & User Manual

Installation, Operation & Service Manual

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

SC Installation, Operation & Application Guide

HEAT HEAT HEAT COOL COOL

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

SC Installation, Operation & Application Guide

HEAT COOL. Meets Commercial California Title 24

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

OWNER S MANUAL Venstar Inc. 08/07

WARNING Important Safety Information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

WARNING Important Safety Information

INSTALLATION INSTRUCTION

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

OWNER S MANUAL Venstar Inc. 08/07

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

Owner s Manual. Digital Thermostat

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

WARNING Important Safety Information

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Owner s Manual. 5+2 Day Programmable Digital Thermostat

WARNING Important Safety Information

ICM 275. Replacement Description

OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER. AquatiControl Technology

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

MULTI-STAGE CHILLER CONTROL

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

SC Installation, Operation & Application Guide

RC-2000 Thermostat Installation Instructions

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Remote Relay Module (RRM)

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Hades 2. Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual. Notes: 1 Square = Foot/Feet

SC Installation, Operation & Application Guide

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

M770 ph Controller Owner s Manual

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

DAY/TIME Button: Selects hour, minute and day setting.

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

GAS MONITOR Model Model

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

Humidity Module OWNER S MANUAL. Complete Control from

Mark 25 Ultrapure Water Conductivity Analyzer

Programmable Thermostat

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEU22P7S RESIDENTIAL. Model HVAC SERVICE PARTS

Duct and Rough Service Carbon Monoxide Sensor

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

Transcription:

MICRO GROW GREENHOUSE SYSTEMS, INC 26 YNEZ RD., SUITE C-4, TEMECULA, CA 9259 PHONE (909)-296-3340 FAX (909)-296-3350 Revision.2, 0-24-02 Ventmate Plus

INSTALLATION PROCEDURES GROWMASTER, GROWMATE PLUS, AND VENTMATE PLUS PANEL MOUNTING Mount the control panel in an accessible location. Make sure that the location is free of vibration and in close proximity to the devices being controlled. Always consider voltage drop of electrical current when locating the control panel. Securely mount the panel. SWITCHING CONTACTORS AND RELAYS The control panel will operate the greenhouse equipment by way of load contactors and load relays. ALL RELAYS AND LOAD CONTACTORS USED MUST HAVE A SURGE SUPPRESSOR INSTALLED ACROSS THE COIL OF THE RELAY OR LOAD CONTACTOR. These surge suppressors are readily available from Micro Grow Greenhouse Systems, Inc. All load contactors and relays are also readily available from Micro Grow Greenhouse Systems, Inc. To decide which to use, follow this guide: LOAD CONTACTORS: Exhaust fans, pad pumps, horizontal air flow fans, heating pumps, fan jets, large heaters, crop lighting, and all other larger electrical loads over /6 H.P. LOAD RELAYS: Signal switching such as the small control lines for gas fired heaters, control lines for vent and shade system controls, small loads such as motorized shutters, other loads up to /6 H.P. CUSTOM CONTACTOR AND RELAY PANEL AVAILABLE A custom-built load contactor and load relay panel is available from Micro Grow Greenhouse Systems, Inc. This panel will contain all the required switching apparatus for your project, as well as a correctly sized machine tool transformer. Contact Micro Grow Greenhouse Systems, Inc. for pricing and availability. TRANSFORMERS A 24 VAC transformer will power the control panel. It is most important to use a MACHINE TOOL TYPE. A Machine Tool Transformer is a heavy-duty variety that will allow for high inrush currents that are associated with the use of load contactors and relays. Micro Grow Greenhouse Systems, Inc. stocks these types of transformers. Use no smaller than a 50 VA Machine Tool Transformer. For a system that has more than three load contactors connected, use a 00 VA Machine Tool Transformer. ELECTRICAL CIRCUITS The electrical circuit that feeds the machine tool transformer must have no other loads connected to it. This will prevent damaging surges from other related electrical devices. Follow all local and national codes in the connection of all the greenhouse equipment. Always allow for voltage drop conditions. Always consider that the greenhouse is a wet environment. Always follow the code rulings for disconnect switches and overcurrent devices on greenhouse equipment. USE A QUALIFIED AND LICENSED ELECTRICIAN AT ALL TIMES. WIRING METHODS Always use stranded wire when connecting cables or conductors to the actual circuit board of the control panel. This will allow flexibility. Use no smaller than #8 gauge-stranded wire for all

outputs. Use no smaller than the recommended wire size of stranded cable for inputs, generally #22 gauge. SENSOR CONDUCTORS: Route sensor conductors separately from control conductors. This is very important so as to reduce electrical interference. Never route sensor conductors in conduits used for other voltages. This is in violation of the electrical code and will cause dangerous interference to the control system. Always locate the actual sensor in the center of the range that is being controlled for accurate readings. Do not allow the sensor to come in contact with any greenhouse structure member such as a post that would give off any radiated heat and cause a false temperature reading. Do not locate the sensor where a particular piece of equipment would cause false readings, such as a heater blowing directly on the sensor. If using a weather station, mount the wind/rain sensor is a clear area, free of any wind obstructions. CONTROL CONDUCTORS: Route all control conductors separately from sensor conductors. This is very important so as to reduce electrical interference. Control conductors maybe routed in conduits that contain other power system wiring only if the insulation material on the conductors is the same as the power system wiring. Consult the national electrical code or local codes if in doubt about the insulation ratings of the wire in use. Remember; always use a qualified and licensed electrician. VENT SYSTEMS, SHADE SYSTEMS, ROLL UP CURTAINS When connecting a vent system, shade system, or roll up curtain ventilation system to the control panel, you must use a separate control box designed for that particular vent or shade system. These are readily available from Micro Grow Greenhouse Systems, Inc. Generally these separate control boxes feature overcurrent protection for the particular motor on the vent or shade system, provisions for direct limit switch connections, and a manual means of operating the vent or shade system independent of the main control system. These separate control boxes will connect the main control system either directly through the outputs of the control system, or they will require control relays for interconnection to the main control system. Consult the individual instructions that come with the vent or shade controls for detailed information. SYSTEM TESTING It is always important to completely and fully test the electrical system by energizing circuits and verifying equipment operations before automatically operating the equipment from the control panel. This would include setting all the vent and shade limit switches at the individual control panels. 2

PROGRAMMING SWITCHES There are two main programming switches located on the Ventmate Plus front panel. These are: RUN-SET SWITCH RUN - Returns the control to the run mode. SET-Advances through the program lights to program the system. VALUE SWITCH UP-Increases the value of the displayed item. DOWN-Decreases the value of the displayed item. PROGRAMMING LIGHTS The programming lights or LED's indicate the mode that the system is in when programming or operating. RUN - System is in the running mode. VENT A-This will light when set Vent A temperatures. VENT B-This will light when set Vent B temperatures. HEATING - This will light when setting heating temperatures. DEHUMIDIFY - This will light when setting the dehumidify setpoint. (Optional sensor required). SET MODE/CLOCK- This will light when setting up the day, night and DIF modes and the internal time clock. CALIBRATE - This will light when the system is in calibration mode. SET UP VENT - This will light when setting the vent timing, and time delays. TO PROGRAM VENT AND HEATING TEMPERATURES DAY TEMPERATURE SETPOINTS:. Toggle the SET switch down until the VENT A LED light is on by itself and the DAY MODE indicator on the LCD display is flashing, release the switch. 2. Hold the VALUE switch either UP or DOWN until the desired temperature is displayed, release switch. The Vent A temperatures for the day mode are now set. For Vent B, perform the above but substitute Vent B for Vent A. For heating:. Toggle the SET switch down until the HEATING LED light is on by itself and the DAY MODE indicator on the LCD display is flashing, release the switch. 2. Hold the VALUE switch either UP or DOWN until the desired value is reached, release switch. YOU CANNOT PROGRAM THE HEATING TEMPERATURES HIGHER THAN THE VENTILATION` TEMPERATURES. NIGHT TEMPERATURE SETPOINTS: 3

. Continue to toggle the SET switch down until the NIGHT MODE indicator on the LCD display is flashing on the LCD display along with either the VENT A, VENT B or the HEATING light, release the switch. 2. Hold the VALUE switch either UP or DOWN until the desired NIGHT value is displayed, release switch. TO SET THE DAY, NIGHT, AND DIF MODE TIMES The control can detect night automatically with the use of an external photocell. If no photocell is connected, it will use the internal 24-hour time clock. You can also use a combination of both if desired.. Continue to depress the SET switch until the SET MODE/CLOCK LED is on and the DAY MODE indicator on the LCD display is on. The word PHO will be displayed. This indicates that the control will use the photocell to go into the day mode. If the internal time clock preferable, use the value switch to advance to a time of day setting. The first value will be hours. Depress the SET switch again to set the minutes, and again to set AM or PM. 2. Depress the SET switch again so that the SET MODE/CLOCK LED is on and the NIGHT MODE indicator on the LCD display is on. Repeat the same procedure as in the above DAY MODE setting for the desired NIGHT MODE selection. 3. Depress the SET switch again so that the SET MODE/CLOCK LED is on and the DIF MODE indicator on the LCD display is on. If DIF is not to be activated, adjust the flashing value to OFF. If DIF is to be activated, adjust the flashing value, bef.x.x, to indicate the number of hours before sunrise to go into DIF. Depress the SET switch again and adjust the flashing value, AF. X.X, to indicate the number of hours after sunrise to come out of DIF. To Set the Clock:. Toggle the SET switch until the SET MODE/CLOCK LED is on and the Ventmate Plus is showing the current time. The item to be set will be flashing. Use the VALUE switch to raise or lower the flashing value. The first value will be hours. Depress the SET switch again to set the minutes, and again to set if it is AM or PM. 2. Return to the RUN mode by toggling the RUN-SET switch up. To Set Vent Information TO SET THE NUMBER OF STAGES: Toggle the SET switch until the SET UP VENT and VENT A LED is on. The number of stages for Vent A will be flashing. Use the VALUE switch to raise or lower the flashing value. The Ventmate Plus will automatically divide the percentage open for each stage. For example, a 4- position selection will allow each stage to open 25%. TO SET THE OPENING TIME: Toggle the SET switch until the SET UP VENT and VENT A LED is on and the LCD display is showing OP XXX, where the XXX is the time in seconds that the vent will take to go from a fully closed to a fully open position. Use the VALUE switch to raise or lower the flashing value. TO SET OVERRIDE POSITION: Toggle the SET switch until the SET UP VENT and VENT A LED is on and the LCD display is showing Or: XX, where the XX is the position that the vent will go to on an override signal input. Use the VALUE switch to raise or lower the flashing value. If an override is not being used, ignore this step. 4

TO SET SAFETY DELAY: A safety delay is the amount of time that your particular vent motor waits to operate upon being sent a signal. This delay is always built into the vent control cabinet. Consult your ventilation motor and controller supplier if you are not sure if you have a safety delay or not. Toggle the SET switch until the SET UP VENT and VENT A LED is on and the LCD display is showing SAF X, where the X is the delay in seconds to protect the vents against false reversals. If the vent starts to move immediately, after manually energizing it, there is most likely no time delay protection. Use the VALUE switch to raise or lower the flashing value. You may choose 0 as one of the choices. TO SET THE TIME DELAY: The time delay is the amount of time that the Ventmate Plus will wait before opening or closing the vent or turning on or off the heating stages. Toggle the SET switch until the SET UP VENT and VENT A LED is on and the LCD display is showing dly X, where the X is the delay in seconds on both energizing and de-energizing stages. Use the VALUE switch to raise or lower the flashing value. RUN MODE After all settings have been made, return to the RUN mode by toggling the SET switch down until the RUN LED light is on, release switch. The control will return to the RUN mode by itself when no other switches are depressed after a timed delay. HIGH and LOW HISTORY The control will automatically track the high and low readings for the past 24 hours for both inputs. The control will automatically display the high and low reading for the temperature and humidity (if in use). TO CALIBRATE THE CONTROL To calibrate the control system, follow these instructions:. Determine the actual temperature at the sensor location. It is best to do this either in the evening or early morning. The solar effect of the greenhouse will provide an inaccurate temperature reading. Always use a good calibration thermometer, digital or mercury, and allow the temperature to stabilize before proceeding. Make sure that all greenhouse heating or cooling equipment has been off, or has not changed operation status for several minutes before calibration. This will help to insure accurate readings. 2. At the control panel, toggle the SET switch till the CALIBRATE LED is on. This will put the control in the calibration mode. Once the control is in the calibration mode, hold the VALUE switch either UP or DOWN to enter a new temperature reading in the display. Release the switch when the desired value is reached. 3. Return to the RUN mode by holding the RUN-SET switch up until the RUN LED light is on, release switch. DIP SWITCH SETTINGS 5

The control system allows for customization of temperature separations and differentials between stage operations. These are determined by the settings of the DIP switches located on the inside of the circuit board of the control. Refer to the drawing of the actual control connections to set these DIP switches. PHOTOCELL The control is equipped with a photocell to detect day and night modes. The photocell is located on the bottom side of the control enclosure. Keep the photocell clean and unobstructed. OPERATIONAL TIPS Keep the cover securely fastened always. The enclosure is a weatherproof, gasket fitted device, but will not provide this degree of protection with the front cover open. In selecting the equipment for each stage, try to minimize energy use with the primary cooling or heating stages. This will insure a lower crop shock effect, and in turn, save on energy costs. CONTROL CARE AND UPKEEP Keep the front panel of control securely closed always. Prevent unauthorized personnel from changing the control settings or switches. Periodically clean the temperature sensor elements with a clean damp cloth to prevent any build-up. 6

THE DISPLAY W ILL ALTERNATE BETW EEN THE CURRENT TEM PERATURE,AN D TH E HIGHEST AND LOW EST READING DURING THE LAST 24 HOURS.THE CURRENT VENT PO SITION,TIME OF DAY AND MODE IS ALSO D ISPLAYED. EASY FRONT PANEL TOGGLE SW ITCHES FOR PROGRAM M ING AND CALIBRATION. PROGRAM M ING OF SEPARATE ST AT U S LIGHTS FOR EASY VEN TILATION AN D H EATING TEM PERATURES FOR DAY AND NIGHT SETTINGS,OPTIONAL DEHUMIDIFY, CALIBRATION AND M ODE SELECTIONS ARE FEATURED. VEN TM ATE CURRENT HIGH LOW RUN SET ON OFF AUTO RUN VEN T A VEN T B HEATING DEHUMIDIFY SET M O D E/CLOCK CALIBRATE SET UP VENT MODE DAY NIGHT DIF VEN T A OPEN VEN T A CLOSE VEN T B OPEN VEN T B CLOSE AIR CIRCULATION HEATING HEATING 2 DEHUMIDIFY EACH OUTPUT HAS A FRONT PANEL MOUNTED SWITCH TO SELECT THE M ODE OF OPERATION.THE PARTICULAR OUTPUT M AY BE LEFT OFF, M ANUALLY OPERATED,OR LEFT IN THE AUTOM ATIC PO SITION OF OPERATION. LIGHTED STATUS INDICATORS WILL SHOW ANY STAGE IN OPERATION,EITHER M ANUAL OR AUTOM ATIC. MICRO GROW G REEN HO USE SYSTEM S,INC. 26 Ynez Road,Suite C-4 Tem ecula,ca 9259 Phone 909.296.3340 Fax 909.296.3350 Project VENTM ATE PLUS FRO NT PANEL Drawn by Date Distributor O rderid G H 0/24/02 N/A N/A 7

24 VAC MACHINE TOOL TRANSFORM ER OPTIONAL HUM IDITY AIR TEM PERATURE PHOTOCELL OVERRIDE +5 VD C SEN SOR COM M ON USE A M ACHINE TOOL VARIET Y O N LY 00 VA IS RECOM M ENDED. IF A SM ALLER SIZED TRAN SFORM ER IS U SED,AD JUST THE FUSE PROT ECTION ACCORDINGLY.(See fuse note) THE CONTROL OUTPUTS ARE RATED AT AM P EACH M AXIMUM.DO NOT EXCEED THIS OR DAMAGE MAY RESULT.DO NOT EXCEED AM P FOR ANY SINGLE OUTPUT OR 4 AM PS TOTAL FOR ALL OUTPUTS. (2 AMPS TOTAL IF A 50 VA TRAN SFORM ER IS IN USE) 24 VAC COM M ON FOR ALL LOADS VEN T A OPEN VENT A CLOSE VEN T B OPEN VENT B CLOSE AIR CIRCULATION HEATING HEATING 2 DEHUMIDIFY 24VAC POW ER INPUT 24VAC POW ER INPUT OUTPUT # OUTPUT #2 OUTPUT #3 OUTPUT #4 OUTPUT #5 OUTPUT #6 OUTPUT #7 OUTPUT #8 COM 24 COM 2 3 4 5 6 7 8 2 FUSED OUTPUT 3 4 5 +5VD C COM COM SEN SO R INPUT TERM INAL STRIP 24 POW ER INPUT DIP SW ITCH IM PORTANT:DO NOT EXCEED 4 AM PS FOR THE FUSE RATING WHEN USIN G A 00 VA T RAN SFO RM ER O R 2 AM PS W H EN U SIN G A 50 VA TRANSFORM ER.USE A SLOW BLOW VARIETY. DIP SW ITCH CONFIGURATION # O FF #2 O FF # O FF #2 O N # O N #2 O FF # O N #2 O N #3 O FF #4 O FF #3 O FF #4 O N #3 O N #4 O FF #3 O N #4 O N #5 O FF #5 O N 2 DEGREES (FACTORY D EFAULT) 3 D EG REES D EG REES 4 D EG REES 2 DEGREES (FACTORY D EFAULT) 3 D EG REES D EG REE 4 D EG REES TURN OFF W H EN VEN T A IS O PEN (FACTORY DEFAULT SETTINGS) TURN OFF W H EN VENT A IS PAST STAGE #7 O FF #7 O N VEN T O PEN S T O 00% (FACTORY DEFAULT SETTINGS) VENT OPENS TO 95% ALL CON N ECTED 24 VAC LOAD RELAYS AN D CON TACTORS M UST H AVE A SURGE PROT ECTION DEVICE INSTALLED ACROSS THE COILS.SU RG E SU PPRESSION DEVICES ARE SU PPLIED W ITH EACH UNIT. ALL CORRECT LOAD CON TACTORS AN D CON TROL RELAYS ARE AVAILABLE FROM M ICRO GROW GREENHOUSE SYSTEM S.50 AN D 00 VA M ACH IN E TOOL TRAN SFORM ERS ARE AVAILABLE FROM MICRO GROW GREENHOUSE SYSTEM S.SEE YO U R D IST RIBUTOR OR CALL MICRO GROW FOR IMMEDIATE SH IPM ENT OF ALL REQUIRED CONNECTION DEVICES AND ACCESSORIES. VENTM ATE PLUS FILE:VENTMATE PLUS INPUTS & OUTPUTS.DW G 0/6/02 MICRO GROW G REEN HO USE SYSTEM S,INC. 26 Ynez Road,Suite C-4 Tem ecula,ca 9259 Phone 909.296.3340 Fax 909.296.3350 Project Drawn by GH 8 VENTM ATE PLUS INPUTS & OUTPUTS Date 0/24/02 Distributor N/A OrderID N/A

TEM PERATURE SEN SOR OPTIONAL STANDARD HUMIDITY SENSOR TO SENSOR TERM INAL ST RIP SENSOR COM M ON BLACK AIR,SO IL,OR RED OUTDOOR TEM PERATURE TO SENSOR TERM INAL ST RIP SENSOR COMMON +5 VD C HUMIDITY GREEN RED BLACK LOCATE SENSOR IN THE CENTER OF THE CONTROLLED AREA,AT BENCH OR CROP LEVEL, AW AY FROM DIRECT CONTACT W ITH GREENHOUSE METAL POSTS AND MEMBERS. LOCATE SENSOR IN THE CENTER OF THE CONTROLLED AREA,AT BENCH OR CROP LEVEL, AW AY FROM DIRECT CONTACT W ITH GREENHOUSE METAL POSTS AND MEMBERS. OPTION AL STAN D ARD AIR TEM PERATURE & HUM IDITY SEN SOR OPTION AL ASPIRATED AIR TEM PERATURE AND HUM IDITY SEN SOR TO SENSOR TERM INAL ST RIP SENSOR COMMON +5 VD C AIR TEM PERATURE GREEN RED HUMIDITY BLACK WHITE TRANSFORM ER FROM ROUTE TO SENSOR INPUT TERM INALS 24 VAC CO M M O N 24 VAC POW ER SENSOR COMMON +5 VD C AIR TEM PERATURE HUMIDITY WHITE BLUE GREEN RED ORANGE OR BROW N BLACK LOCATE SENSOR IN THE CENTER OF THE CONTROLLED AREA,AT BENCH OR CROP LEVEL, AW AY FROM DIRECT CONTACT W ITH GREENHOUSE METAL POSTS AND MEMBERS. LOCATE SENSOR IN THE CENTER OF THE CONTROLLED AREA,AT BENCH OR CROP LEVEL, AW AY FROM DIRECT CONTACT W ITH GREENHOUSE METAL POSTS AND MEMBERS. VENTM ATE PLUS SEN SO RS - PAG E O F 2 MICRO GROW G REEN HO USE SYSTEM S,INC. 26 Ynez Road,Suite C-4 Tem ecula,ca 9259 Phone 909.296.3340 Fax 909.296.3350 Project Drawn by GH VENTM ATE TEM PS & HUM IDITY SEN SO RS Date 0/24/02 Distributor N/A OrderID N/A 9

SENSOR COM M ON BLACK PHOTOCELL RED PHOTOCELL OVERRIDE INPUT SENSOR COM M ON OVERRIDE INPUT 8 4 5 RELAY IS A DPDT 4, 3.24 VAC COIL 2, 9.COM M ON TERM INALS 8, 5.NORM ALLY OPEN TERM INALS 4,.NORM ALLY CLOSED TERM INALS 4 2 3 9 24 VAC FROM OVERRIDE DEVICE SUCH AS W EATHERM ASTER OR W EATHERM ATE. VEN TM ATE PLUS SEN SO R - PAG E 2 O F 2 MICRO GROW G REEN HO USE SYSTEM S,INC. 26 Ynez Road,Suite C-4 Tem ecula,ca 9259 Phone 909.296.3340 Fax 909.296.3350 Project VENTM ATE PLUS PHO TO C ELL SEN SO R Drawn by Date Distributor O rderid G H 0/24/02 N/A N/A 0

WIND SPEED SEN SO R WEATHERSTAT SEN SO R SEN SO R COMMON +5 VD C WHT RED RAIN WIND OUTDOOR TEM PERATURE GRN BLK YEL RAIN SEN SO R OUTDOOR TEM P. SEN SO R LOW VOLTAGE SENSOR CABLE RAIN HEATER ORG 24 VAC BLU 24 VAC COM BRN 24 VAC 24 VAC COM PO W ER OUTPUT ST R IP 2 2 24 VAC COM 24 VAC POW ER IN P U T COM ST R IP 2 3 +5V COM DIP SW IT CH SEN SO R IN PU T ST R IP FACTORY JU M PE R DO NOT REM OVE DIP SW IT C H SET T IN G S The DIP sw itch can be used to change the wind time delays. Referto the Weatherstat manual. WEATHERSTAT /2" RIGID GALVANIZED MOUNTING CONDUIT 24 VAC TRANSFORM ER 40 VA M INIMUM RATING OUTPUT NOTE: THE OUTPUTS OF THE WEATHERSTAT MAY CONNECT DIRECTLY TO THE OVERRIDE INPUTS OF A CONTROL SYST EM CAPABLE OF ACCEPTIN G A 24 VAC SIG N AL.IF OTHER SW IT C H IN G IS DESIRED,THE OUTPUTS MAY BE CONNECTED TO THE COILS OF CONTROL RELAYS TO INTERRUPT THE AUTOM ATIC OPERATION OF VEN TS,RETRACTABLE ROOFS,ETC. VENTMATE PLU S DIRECT OVERRIDE CONNECTIONS 8 4 5 K-2 4 3 2 9 RAIN 8 5 4 K- 4 3 2 9 WIND WIND 24 VAC OUTPUT RAIN 24 VAC OUTPUT 24 VAC COM SE N SO R COMMON WIND/RAIN OVERRIDE FILE:VEN T M AT E PLUS DIRECT OVERRIDE.DW G 0/29/02 PHOTOCELL COM 2 3 4 5 6 7 8 OUTPUT # OUTPUT # 2 OUTPUT # 3 OUTPUT # 4 OUTPUT # 5 OUTPUT # 6 OUTPUT # 7 OUTPUT # 8 24 FU SED OUTPUT VENTMATE PLU S 24 POW ER IN PU T COM TERM INAL ST R IP SE N SO R IN PU T 2 3 4 5 +5VD C COM COM DIP SW IT CH RED BLACK LOCATE SENSOR IN TH E CEN TER OF TH E CONTROLLED AREA,AT BENCH OR CROP LEVEL, AW AY FROM DIRECT CONTACT WITH GREENHOUSE M ETAL PO STS AND MEMBERS. MICRO GROW G REEN HO USE SYSTEM S,INC. 26 Ynez Road,Suite C-4 Tem ecula,ca 9259 Phone 909.296.3340 Fax 909.296.3350 Project Drawn by GH VENTM ATE PLUS DIREC T O VERRIDE CONNECTIONS Date 0/29/02 Distributor N/A OrderID N/A

LIMITED WARRANTY Micro Grow Greenhouse Systems, Inc. warrants that all of the products Micro Grow Greenhouse Systems, Inc. manufactures are free from defects at the time of shipment by Micro Grow Greenhouse Systems, Inc. This warranty covers defects in workmanship and materials. No warranty is extended on any parts, materials, or components manufactured by others and purchased by Micro Grow Greenhouse Systems, Inc., and any warranty on these materials is limited to the warranty supplied by the original manufacturer or supplier of said products only. This warranty excludes any and all damages cause by installation by unqualified individuals, damage by misuse or neglect, shipment damage, alterations to original manufacturing, and improper installation or use for any reason than intended by manufacturer. This warranty may not be altered in any manner except with the written authorization of one the officers or owners of Micro Grow Greenhouse Systems, Inc. The only and sole liability of Micro Grow Greenhouse Systems, Inc. under this warranty is limited to repairing, replacing or the issuance of credit for any products returned to Micro Grow Greenhouse Systems, Inc., during the warranty period of twelve (2) months from date of shipment. This warranty is specifically conditioned upon Micro Grow Greenhouse Systems, Inc. being notified in writing promptly upon discovery of any product defects by the buyer or end user. The product must then be returned prepaid to Micro Grow Greenhouse Systems, Inc. within the twelve month warranty period for inspection by Micro Grow Greenhouse Systems, Inc. Upon inspection of said product, Micro Grow Greenhouse Systems, Inc. will notify buyer or end user of its findings. At Micro Grow Greenhouse Systems, Inc. sole discretion, the product will be replaced, repaired or a credit will be issued for the original sale price of the product, provided that damage has not occurred due to misuse, neglect, improper use or installation as outlined above, shipping damages or accident. MICRO GROW GREENHOUSE SYSTEMS, INC. SHALL NOT BE LIABLE FOR ANY DAMAGES BEYOND THE ACTUAL ORIGINAL COST OF THEIR PRODUCT EITHER DIRECTLY OR INDIRECTLY ARISING FROM DEFECTIVE PRODUCTS OR WORKMANSHIP. 2