Evaporator E4 Series. Innovative Refrigeration Solutions. Floor Mounted Blast Chiller/Freezer F - Series

Similar documents
Remote Air Cooled Condensers C2 Series

Kirby CO 2 Evaporators

500 EX Fusion Compressor Series

LOW PROFILE EVAPORATORS

Evaporators 60HZ version

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

YAH SERIES FAN COIL UNITS

Kirby Commander Condensing Unit

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

Kirby Drop-In Packaged Refrigeration Units

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

Engineered efficiency - no matter where or what. KMe Coolers Fresh ideas from Searle. GEA Searle

Why use Blast Chiller or Freezer?

Super-Flo Low Profile Unit Cooler

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

Low Flow Unit Coolers

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data Ducted Three Phase Split System Air Conditioner

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

AIR COOLED CONDENSERS

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

TEC Coolers. GEA Heat Exchangers. GEA Searle

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

New Industrial Dual Flow Unit Coolers

OPERATING INSTRUCTIONS

LOW PROFILE UNIT COOLER

Center Mount Unit Coolers

EHH SERIES DRAW THROUGH FAN COILS CFM

General Features. 01. CoolSmart Controller Professional Refrigeration Upright Cabinet Series

High Profile Evaporator

LOW PROFILE UNIT COOLER

ENGINEERING SPECIFICATIONS

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)

ENGINEERING SPECIFICATIONS

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

Compact SLIM. Air cooler GASC. Air coolers in a flat design with forced draught fans Optimal for commercial cooling. HFCs, CO 2 0.

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

GHF CXGHF GGHF. The all-in-one solution for commercial refrigeration! Güntner Info. High efficiency wall/ceiling-mounted air cooler. 0.

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

commercial refrigeration products

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Unit Features & Benefits RQPM/RQRM Series

Goedhart VNS. Air coolers for agricultural applications Cu/Al R404A - CO 2. engineering for a better world. GEA Heat Exchangers

KTL Two-Way Low Profile Evaporators

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Galletti Water chillers and heat pumps catalogue

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

recooler HP EQKR HEAT PUMP

Low Profile Unit Coolers

PLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE

TOSHIBA AIR CONDITIONING

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

High Heat COP. High/Low Stage

ACMVTECH HIGH EFFICIENCY UNITARY AHU

EDPAC International Close Control Air Conditioning Products E

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Air cooler BC50 Blast freezer

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Process glycol chillers

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Compact CUBIC. Air cooler GSF. Highly efficient compact air cooler Optimal for commercial refrigeration. HFCs 1 55 kw

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

Blow through unit coolers LEX. Standard coolers for cooling & freezing rooms

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

Wall Mounted Split Systems

QZHW Fan Coil Unit. Key features. Specifications

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Küba SG commercial

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Hi-Pres Cooling Products Catalogue. Product Catalogue

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

30RH B Nominal cooling capacity kw Nominal heating capacity kw

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

THE CARRIER COMFORT LINE

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Transcription:

Evaporator E4 Series Floor Mounted Blast Chiller/Freezer F - Series Ceiling Mounted Blast Chiller/Freezer C - Series Medium & Low Temperature Models

Application Benefits / Features NOMENCLATURE GREENHALGH EVAPORATORS High Efficiency Heat Exchanger Coil XX XXX X X Capacity steps in the range are compatible with most compressor capacities Optimised with inner grooved tube and designed to maximise the sensible capacity and minimise latent heat and frost losses Hydrophilic blue aluminium fins Leak tested at 31 bar pressure 8.5mm fin spacing for medium and low temperature applications Nominal Evaporator Capacity (XXX x 10) = Watts @ 6KTD R404A E4 Series Evaporators - Blast Chiller/Freezer Applications F = Floor Mounted C - Ceiling Mounted Number of Fans and Fan diameter STATE OF THE ART DESIGN SOFTWARE Greenhalgh thermodynamic & aerodynamic design software was developed, tested and proved in Germany and assures accurate designs FANS High energy-efficiency fans Fan nozzle designed for maximum air flow and air throw with reduced power input Ziehl Abegg fan motors as standard Motor protection to IP54 and insulation to class F Three phase fans as standard in this series: 415V/1N/50Hz Wiring to AS/NZS standards Example: E4-4433F/3.63 Nomenclature PERFORMANCE CORRECTION FACTORS F1 For Temperature Legend E4 = Series F = Floor Mounted 4433 = Capacity x 10 in Watts on R404A @ 6KTD C = Ceiling Mounted F or C 3 = Number of Fans 63 = Fan diameter x 10 in mm (630mm) DEFROST Designed for efficient cooling capacity during an 8 hour cycle under humid conditions Electrical defrost elements designed to thermodynamic calculation of latent heat/ frost energy related to an 8 hour defrost cycle Robust stainless steel electric defrost elements with high insulation cable connections to meet UL-SA5102 and CSA-LR19489 standards Factory tested at full load Defrost elements wired to terminal box suitable for moist conditions (IP66) and low temperature (tested at -40C) F.1 EVAPORATOR TEMPERATURE MULTIPLICATION FACTOR DUAL TEMPERATURE CAPACITY CORRECTION FACTORS -35 C -30 C -28 C -25 C -24 C -20 C -15 C -10 C -5 C 0 C 0.95 0.978 0.98 0.99 1.0 1.023 1.06 1.08 1.1 1.12 RATING CONDITION Options Customised fin spacing Coils for glycol applications Thermostatic expansion valve can be factory fitted by prior arrangement Overheat Klixon protection as standard EC fan motors For Calculation of the Evaporator Capacity under different conditions Rated Evaporator Capacity R404A in Watts 2 3

E4-f FLOOR MOUNTED Series Model Capacity in Watts @ 6KTD R404A R22 R134A l/s Air Flow Fan Motors Air Throw Fan Qty (m) x Ømm Amps Watts Power Supply Defrost Heater Watts Weight (kg) Inlet Connections Outlet Ext Equaliser Drain Length L Dimensions Width W Height H Dimensions Diagram E4 SERIES (8.5mm FIN SPACING - 3FPI) (BLAST FREEZER & BLAST CHILLER) FLOOR MOUNTED SERIES - HIGH STATIC FANS FOR PLENUM APPLICATIONS E4-2960-F/2.63 29600 28750 25100 7,431 30 2 x 630 9.60 5200 12000 280 22 x 2 42 6.35 2100 796 2465 E4-3490-F/2.63 34900 33760 29700 7,210 30 2 x 630 9.60 5200 13000 310 22 x 2 54 6.35 2200 796 2465 E4-4433-F/3.63 44330 42800 40000 11,229 31 3 x 630 14.40 7800 14000 410 22 x 4 54 x 2 6.35 2700 796 2655 E4-5260-F/3.63 52600 50800 46400 10,829 31 3 x 630 14.40 7800 15000 455 22 x 4 54 x 2 6.35 2800 796 2655 E4-6080-F/3.63 60800 59200 50100 15,104 32 3 x 630 19.20 10400 16000 680 22 x 4 64 x 2 6.35 3490 796 2845 380-415/3N/50 NPT 1 1/2 E4-7070-F/4.63 70700 69530 58900 14,528 32 4 x 630 19.20 10400 19800 740 22 x 4 64 x 2 6.35 3490 796 2845 E4-7640-F/3.80 76400 73430 71100 20,278 28 3 x 800 12.00 6000 20400 820 22 x 3 54 x 3 6.35 3600 1050 3434 E4-8670-F/3.80 86700 81000 80000 19,272 28 3 x 800 12.00 6000 25500 910 22 x 3 54 x 3 6.35 3600 1050 3434 E4-10770-F/4.80 107700 104000 94300 23,873 29 4 x 800 16.00 8000 27000 1180 22 x 3 54 x 3 6.35 4200 1050 3434 Detailed drawings for each model with full specifications available on request. Capacities based on 6KTD applications NOTE: All E4 Series are supplied with defrost elements fitted 4 5

E4-c CEILING MOUNTED Series Model Capacity in Watts @ 6KTD R404A R22 R134A l/s Air Flow Fan Motors Air Throw Fan Qty (m) x Ømm Amps Watts Power Supply Defrost Heater Watts Weight (kg) Inlet Connections Outlet Ext Equaliser Drain Length L Dimensions Width W Height H Dimensions Diagram E4 SERIES (8.5mm FIN SPACING - 3FPI) (BLAST FREEZER & BLAST CHILLER) ROOF MOUNTED SERIES E4-760-C/2.45 7600 7420 6500 2,918 16 2 x 450 2.10 1080 6000 108 16 35 6.35 1540 485 951 E4-1190-C/1.63 11900 11600 10300 4,422 30 1 x 630 4.80 2600 6000 150 22 42 6.35 1540 700 1268 E4-1660-C/1.63 16600 16200 13200 4,184 30 1 x 630 4.80 2600 8400 187 22 54 6.35 1540 700 1268 E4-2270-C/2.63 22700 22000 20000 8,688 32 2 x 630 9.60 5200 8000 257 22 54 6.35 2630 783 1268 NPT 1 1/2 E4-2600-C/2.63 26000 25250 23000 8,506 32 2 x 630 9.60 5200 8000 276 22 54 6.35 2630 783 1268 E4-3130-C/2.63 31300 30240 28600 8,143 31 2 x 630 9.60 5200 11200 310 22 x 2 64 6.35 2630 783 1268 E4-3600-C/2.63 36000 34600 33000 8,017 31 2 x 630 9.60 5200 11200 348 22 x 2 64 6.35 2630 783 1268 E4-4380-C/3.63 43800 42800 35500 13,283 34 3 x 630 14.40 7800 12600 419 22 x 2 54 x 2 6.35 380-415/3N/50 3430 783 1649 E4-5370-C/3.63 53700 52250 44500 12,871 34 3 x 630 14.40 7800 12600 482 22 x 4 64 x 2 6.35 3430 783 1649 E4-6190-C/3.63 61900 60120 51100 12,499 33 3 x 630 14.40 7800 18000 534 22 x 2 64 x 2 6.35 3430 783 1649 E4-7090-C/4.63 70900 68800 58400 17,210 34 4 x 630 19.20 10400 24000 724 22 x 2 64 x 2 6.35 4830 855 1580 NPT 2 1/2 E4-8100-C/4.63 81000 78300 60150 16,728 34 4 x 630 19.20 10400 24000 701 22 x 3 64 x 3 6.35 4830 855 1580 Detailed drawings for each model with full specifications available on request. E4-8417-C/3.80 84170 80400 78000 21,850 30 3 x 800 12.00 6000 26000 833 22 x 3 64 x 3 6.35 5230 940 1725 E4-9970-C/3.80 99700 94950 90000 21,449 30 3 x 800 12.00 6000 35100 1008 22 x 3 64 x 3 6.35 5230 940 1725 Capacities based on -24C SST/ 6KTD for low temperature models NOTE: All E4 Series are supplied with defrost elements fitted 6 7

Ph +61 2 9725 3318 Re-Order No. RA-E4-EVAPORATOR Unit 2/16 Vicars Place, Wetherill Park, Sydney, NSW, 2164, AUSTRALIA Tel: +61 2 9725 3318 I Fax: +61 2 9725 5719 www.refrigerationagencies.com.au