Q/Tec TM QA-Series Air Conditioners

Similar documents
Q-Tec TM QC-Series Chilled Water Air Conditioner

Q-TEC QC-Series Chilled Water Air Conditioner

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps

Q-TEC Q24A-Q60A Air Conditioners

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

Q/Tec TM QW-Series Water-to-Air Heat Pumps

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS

GREEN REFRIGERANT R-410A

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features

WALL-MOUNT HEAT PUMPS - (60HZ)

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models

THE WALL-MOUNT HEAT PUMPS EER, (60HZ)

GREEN REFRIGERANT R-410A

THE WALL-MOUNT 6-TON AIR CONDITIONERS

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

I-TEC I30A1D-I60A1D 2-Stage Compressor High Efficiency Air Source Air Conditioners w/dehumidification

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A

QTEC SERIES PACKAGED AIR CONDITIONER Models: Q24A1 Q30A1 Q36A1 Q42A1 Q48A1 Q60A1

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

1.5 to 3 Ton 208V to 460V 60hz Air Conditioner Specifications

Product Guide. Wallmount. Air Conditioners & Heat Pumps

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

Wall Mounted Air Conditioners with Gas Heat Models AVGA

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

Scholar III Unit Ventilator

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

Installation Instructions

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

RGE 13 A T - 1 A

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

TECHNICAL SPECIFICATIONS

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

QW SERIES GEOTHERMAL R-410A STAGED CAPACITY PACKAGED HEAT PUMP INSTALLATION INSTRUCTIONS QW2S1 QW3S1 QW4S1 QW5S1. Models:

Product Data. Fig. 1 - Unit 50VR -A

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5

13 GEP A L P - 1 A

PAJ3. Product Specifications

SKYPAK II, 3 Ton Series, gives you a

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Commercial High-Efficiency Condensing Units

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

Commercial High-Efficiency Condensing Units

50TM COMBINATION HEATING/COOLING UNITS

QTEC SERIES PACKAGED AIR CONDITIONER Models: Q24A1D Q30A1D Q36A1D Q42A1D Q48A1D Q60A1D INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

MERIT Series R-410A - Upflow / Horizontal

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc.

MERIT Series R-410A - Upflow / Horizontal

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA

50TM TFF COMBINATION HEATING/COOLING UNITS

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

SKYPAK II, 3 Ton Series, gives you a

Submittal Data Performance Data Electrical Data

2 shp 13 lc 1 36 t - 1 a

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

QTEC SERIES PACKAGED HEAT PUMP Models: Q24H1 Q30H1 Q36H1 Q42H1 Q48H1 Q60H1 INSTALLATION INSTRUCTIONS

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

RSG16**S1M. Split System Air Conditioner 16 SEER

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

SKYPAK II Heating & Cooling Self Contained Packages

48PGD/E/F/L/M/N PG20-28

PAR5. Product Specifications

MACH N-407 Heat Pump Air-Cooled Chiller

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

MAC N-407 Air-Cooled Chiller

Transcription:

Q/Tec TM QASeries Air Conditioners The Q/Tec series self contained packaged air conditioner is designed to be installed inside a building structure against an exterior exposed wall. Q/Tec s design provides whisper quiet operation with total comfort for the occupants at efficiency levels up to 24% above the federal standard. This design eliminates the need for roofmounted equipment and outside condensing units and can meet your specific architectural requirements. Q/Tec s quiet technology provides extremely low sound levels (both indoor and outdoor) by using special components and materials in the construction of the unit. By using special motors, sound insulation and other sound absorbing features, we have built an air conditioner system that is significantly quieter than competitive product available today. Q/Tec is suitable for both new construction and renovation projects for schools, modular buildings and light commercial buildings. A variety of ventilation and dehumidification options are designed to address your project s indoor air quality and dehumidification requirements. The Q/Tec Series unique design allows all maintenance and service to be performed inside the building to facilitate multistory installations. Access to air filters and controls is accomplished through a hinged front panel for easy accessibility. All Q/Tec Series models are built on heavy duty permanent rollers for easy installation and removal from the wall sleeve for additional service access. Q/Tec s durable, easy to clean cabinet is aesthetically pleasing and comes standard with side and bottom trim pieces. Two types of cabinet finish are available: a durable two tone (slate and platinum) vinyl covered steel, or gray prepainted steel. Product Features Scroll Compressor The Copeland scroll compressor has been designed for increased efficiency, quieter operation with reduced shutdown noise and improved reliability for longer life. Eliminates need for crankcase heater and suction line accumulator. Phase Rotation Monitor Standard on all 3 phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Indoor Blower Motor All models feature a variable speed (ECM) motor providing super high efficiency, low sound levels and soft start capabilities. The motor is selfadjusting to provide the proper airflow rate at high static pressure for ducted installations without user adjustment or wiring changes. Optional dehumidification circuit (hot gas reheat) provides improved dehumidification when used with humidistat. Outdoor Fan Motor The PSC outdoor fan motor has double oil capacity sleeve bearings and is totally enclosed for extended life. Copper Tube/Aluminum Fin Coils Grooved copper tubing and enhanced aluminum fins provide maximum heat transfer and high energy efficiency. Evaporator coil constructed with hydrophilic fin stock that seals fin surface against aluminum oxide formation, is resistant to mold and mildew growth (tested to ASTM D3273, no growth), and reduces beading of condensate on the fin surface. Optional phenolic coated coils are available. Cabinet Constructed of 2 gauge prepainted or vinyl laminated galvanized steel. Choice of either two tone vinyl finish with slate front panels and platinum cabinet for designer appearance, or gray painted steel. Vinyl finish is very resistant to scratching and marring and is very easy to clean. Tamper resistant fasteners are provided for access panels. Unit includes builtin rollers for easy installation into wall sleeve and removal for service if necessary. Hinged, lockable front panel for filter service and access to primary functional electrical controls. Insulation Cabinet is fully insulated with foil covered, high density fiberglass insulation with sealed edge treatment and special sound deadening insulation material in the compressor section. All insulation is designed to resist mold and mildew growth and facilitate ease of cleaning. Electrical Components Are easily accessible for routine inspection and maintenance through front service panels. Circuit breaker standard on all 2/23V models and rotary disconnect standard on all 4V models. Circuit breaker/rotary disconnect access is through lockable access panel. Lock and key provided as standard equipment. Electric Heat Strips Backup electric heat strips feature automatic limit safety controls. Heater packages are factory installed for all models. See Electric Heat Table for available options. Hot Water Coil A plenum mounted hot water coil is available for both freeblow and ducted applications. Air Filters Oneinch disposable panel type air filters are standard. Optional twoinch pleated and twoinch fiberglass disposable air filters are available. Optional Energy Recovery Ventilator has a separate filter for exhaust air to keep ERV clean. Refrigerant Service Ports Located in filter compartment for easy access. Liquid Filter Dryer Standard on all models. High Pressure Switch Provides refrigerant circuit high pressure protection. Includes lockout circuit that is resettable from room thermostat. Compressor Control Module Provides short cycle protection for the compressor, which extends compressor life. Ventilation Packages Barometric fresh air damper standard on all units and allows up to % outside fresh air. Optional energy recovery ventilator can provide up to 45 cfm of outside air and exhaust through the unit while maintaining indoor comfort and humidity levels. Economizer, commercial room ventilator and blankoff plate are also available. Diagnostic Light System service indicates high or low pressure switch operation for compressor protection. Located inside control panel. Stainless Steel Drain Pans Provides extended life of the evaporator and condenser drain pans for maximum corrosion resistance. Side Trim Piece Extension Provides cabinet extension between interior wall and unit when wall thickness is between 2 inches to 4 inches. Standard feature shipped with all models. Optional trim kits for thinner walls available. Wall Sleeve Constructed of gauge galvanized steel, coated with epoxy primer and a baked on polyester enamel paint, which allows it to withstand hours of salt spray tests per ASTM B73. Required for all models. Ordered separately. Complies with efficiency requirements of ANSI/ASHRAE/IESNA 9.24. Certified to ANSI/ARI Standard 3923 for SPVU (Single Package Vertical Units). Commercial Product Not intended for Residential application. Form No S3329 Supersedes S3397 Page of 2

Capacity and Efficiency Ratings MODELS QA24 QA3 QA3 QA42 QA4 QA Cooling Capacity BTUH 24, 3,,2 4, 4, 53, EER 2.9.4 9.2 9. 9.5 9. Capacity is certified in accordance with ANSI/ARI Standard 3923. 2 EER = Energy Efficiency Ratio and is certified in accordance with ANSI/ARI Standard 3923. All ratings based on fresh air intake being % closed (no outside air introduction). Specifications 2, 2½ and 3 Ton MODELS LECTRICAL RATING HZ perating Voltage Range COMPRESSOR CIRCUIT A oltage ated Load Amps ranch Circuit Selection Current ock Rotor Amps FAN MOTOR & CONDENSER an MotorHPRPMSPD an Motor VoltsAmps andiacfm MOTOR & EVAPORATOR Blower Motor HPSPD lower MotorVoltsAmps CFM Cooling & E.S.P. w/filter (RatedWet Coil) ilter Sizes (inches) STD. HIPPING WEIGHTLBS. QA24A 3/2 QA24B 3/2 QA24C 45 QA3A 3/2 QA3B 3/2 QA3C 45 QA3A 3/2 QA3B 3/2 QA3C 4 445 E 2 2 3 4 3 2 2 3 4 3 2 2 3 3 O 973 4 973 4 973 V 23/2 4 23/2 4 23/2 4 R.2/. 9 5.7/. 2 3..3/2. 5 7.3/. 4. 4.4/. 3./. 9 5. 2 B. 9 7. 3. 4. 9 4. 5. 3. 9 5. 2 L 5/5 45/45 22. 4 72.5/72. 5 3/3 3 / 77/77 39 F /5 75 /5 75 /5 75 F 23/2. 4. 23/2. 4. 23/2. 4. F 2" 2" 2" /2 Variable /2 Variable /2 Variable B 23/2. 23/2 2. 7 23/2 3. 7 @. ESP @.5 ESP 2 @.5 ESP F x2x + xx x2x + xx x2x + xx S 5 5 5 Specifications 3½, 4 and 5 Ton MODELS LECTRICAL RATING HZ perating Voltage Range COMPRESSOR CIRCUIT A oltage ated Load Amps ranch Circuit Selection Current ock Rotor Amps FAN MOTOR & CONDENSER an MotorHPRPMSPD an MotorVoltsAmps andiacfm MOTOR & EVAPORATOR Blower Motor HPSPD lower MotorVoltsAmps CFM Cooling & E.S.P. w/filter (RatedWet Coil) ilter Sizes (inches) STD. HIPPING WEIGHTLBS. QA42A 3/2 QA42B 3/2 QA42C 45 QA4A 3/2 QA4B 3/2 QA4C 45 QAA 3/2 QAB 3/2 QAC 4 44 5 E 2 2 3 4 3 2 2 3 4 3 2 2 3 3 O 973 4 973 4 973 V 23/2 4 23/2 4 23/2 4 R.9/2. 2.4/3. 7 7. 9./2. 4 2./4.. 5.2/27. 5.5/7.. B 2. 3. 7 7. 2. 4 4.. 5 2. 9 7. 9. L 9/9 / 44 37/37 9/9 4 4/4 23/23 2 F /5 75 /3 /3 F 23/2. 4. 23/2. 9 4. 23/2. 9 4. F 2" 2" 75 2" 75 /2 Variable /2 Variable 3/4 Variable B 23/2 3. 7 23/2 3. 7 23/2 4. 9 2 @.5 ESP 4 @.2 ESP 55 @.2 ESP F x2x + xx xx + xx xx + xx S 53 5 5 Factory Builtin Electric Heat Table Nominal Kw 5.. 9.. 2. 5. Form No S3329 Supersedes S3397 Page 2 of 2 A t 24V () A t 2V () A t 4V (2) At 4V (2) Kw Ph Amps 3Ph Amps Btuh 5. 2. 7,5. 4. 4,47 9. 2. 7,77. 4. 7 4,3 2. 2. 9,95 5. 2. 5 3.,95 () These electric heaters are available in 23/2V units only. (2) These electric heaters are available in 4V units only. 5 2 3 5 3 4 5 5 Kw Ph Amps 3Ph Amps Btuh 3.7. 2,799 4.5 2. 5 5,9.7. 7 3,3 7.5 3.,59 9..,77.2 54. 3. 2,39 Kw 3Ph Amps Btuh Kw 3Ph Amps Btuh. 7. 2 2,47 5.52. 9,4 2 9.. 3,77.2. 4 2,2 3 2. 4. 4 4,95.4 3. 9 37, 3 5.. 5,95 3. 7. 3 47,99

Electrical Specifications Model Rated Volts and Phase No. Field Power Circuits QA24AZ A5 A 23/2 QA24BZ B 23/23 B9 QA24CZ C 43 C9 QA3AZ A5 23/2 A QA3BZ B 23/23 B9 B2 QA3CZ C 43 C9 C2 QA3AZ A5 23/2 A A5 or 2 QA3BZ B 23/23 B9 B5 QA3CZ C 43 C9 C5 QA42AZ A5 23/2 A A5 or 2 QA42BZ B 23/23 B9 B5 QA42CZ C 43 C9 C5 QA4AZ A5 23/2 A A5 or 2 QA4BZ B 23/23 B9 B5 QA4CZ C 43 C9 C5 QAAZ A 23/2 A5 or 2 QABZ B9 23/23 B5 QACZ C9 43 C5 3 Minimum Circuit Ampacity 2 3 55 5 24 33 2 7 32 57 34 43 4 23 2 33 5 3 2 2 53 4 27 33 33 5 3 2 53 3 4 27 5 3 2 2 53 3 4 27 4 59 4 32 3 55 7 9 2 Single Circuit Maximum External Fuse or Ckt. Brkr. 3 3 2 5 5 2 45 5 5 2 9 3 3 5 5 2 3 5 5 9 5 5 2 3 5 5 9 4 5 5 2 3 9 45 45 2 2 3 2 Field Power Wire Size 2 4 4 2 4 4 2 4 4 4 2 4 4 4 2 4 2 2 2 4 2 2 2 Ground Wire 3 Minimum Circuit Ampacity Ckt. A Ckt. B 2 Ground Wire Size Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. 2 Based on 75 C copper wire. All wiring must conform to the National Electrical Code and all local codes. 3 These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest revision), article 3 for power conductor sizing. CAUTION: When more than one field power conductor circuit is run through one conduit, the conductors must be derated. Pay special attention to note of table 3 regarding Ampacity Adjustment Factors when more than three conductors are in a raceway. 2 4 4 2 4 4 2 4 4 2 4 4 2 2 2 2 2 2 5 5 5 59 Dual Circuit Maximum 2 Field External Fuse Power or Ckt. Breaker Wire Size Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Form No S3329 Supersedes S3397 Page 3 of 2

Installation Overview Outside louver grille Unit installed with free blow plenum box Unit and Wall Sleeve Opening and Dimensions Form No S3329 Supersedes S3397 Page 4 of 2

Dimensions of Basic Unit for Architectural and Installation Requirements (Nominal) Drawings are not to scale Optional Hot Water Coil Performance Heating Capacity @ F Water and 7 F Return Air 9 BTU/HR 7 5.5GPM 2GPM 4GPM GPM GPM GPM 4 3 7 9 2 3 4 5 CFM Form No S3329 Supersedes S3397 Page 5 of 2

Cooling Application Data Outdoor Temperature F Model QA24 QA3 QA3 QA42 QA4 QA D.B./ W.B. 2 75/ 2 / 7 5/ 72 75/ 2 / 7 5/ 72 75/ 2 / 7 5/ 72 75/ 2 / 7 5/ 72 75/ 2 / 7 5/ 72 75/ 2 / 7 5/ 72 COOLING CAPACITY 75 o o 5 o 9 o 95 o o o 5 o 5,,2 2, 7, 32,, 3,3 22,9 33,4 22,2 39, 22, 37,7 27, 4,2 2,9 47,9 27, 43, 3, 45,9 29,7 54,7 3,4 49,4 33,9 52,7 32,9 2, 33,7 55,, 5, 34,7 7,, 23,9 7, 2, 7,2 3,4 7,5 29, 22,4 32,4 2,9 37,9 22,3,7 27, 3,9 2,4 45,5 2, 4, 29,5 44,2 2,9 5,7 29,4 4, 33,3 5, 32, 59,4 33, 52,5, 57,2 34,9,9,4 22,7 7,,2,9 29, 7, 2,4 2,9 3,5 2,7 3,2 2, 33,9 2,2 37,,9 43,2 2, 3,4 2, 42, 2,3 4,9 2,5 44, 32,5 49, 32,2 5,3 32,4 5,2,5 55,7, 4,,3 Below 5 F, unit requires a factory or field installed low ambient control. 2 Return air temp. F. 2,, 24,, 27,,5 27,3 2,4 3, 2,4 34, 2,3 32,2,4 3,4,4 4,,3 3, 27, 4,3 27, 4, 27,4 42, 3, 47,5 3, 53, 3, 4,, 54,3,,3 34,9 2,9,3 24,,4 2,7, 2, 2, 3, 2,2 33,4 2, 3,7 24,7,2 24,9 39, 24,5 34, 2,9 4, 27, 44,5 2, 4, 3, 4, 3,4 5, 3, 4,2 34, 53,, 5,9 34,4 2,3, 23,,2, 5,7,3 2,7 29,4 2, 32,2 2,3 29,4 23,9 34,2 24,3 37,4 23,5 33,5 2,2 39, 2, 42,7, 3,5 3,4 44, 3,9 49, 29,9 44, 34,4 5,9, 5, 33,9 9,7 5, 23,2,, 5,3 24,5 2,2 2,9 2,7 3,2 9, 2, 23, 33, 23,7,7 22, 32,3, 3, 2,2 4,, 37, 29,7 43, 3,4 47,2 29, 43, 33,9 5,9 34, 54,9 33,2 9,3 5,3 23, 5, 24,5 4, 23, 9,9 2,4 2,5 3,2 9,2 27, 22,4 32,2 23, 34,3 2,7 3,4, 37,4, 39, 24,2 3, 2,9 42,9 29, 45,7 2, 4,9 33,4 5, 34,5 53,2 32,4 o 9, 5, 22, 5,7 24, 4,5 23,4 9,5 2, 2,3 29,,7 2, 2,7 3,3 22,5 32,9 2, 3,7 24,5 3,9,5 3, 23,5, 2,2 42, 29,3 44,3 27, 4,9 32, 49,2 34, 5,7 3,4 Form No S3329 Supersedes S3397 Page of 2

Indoor Blower Performance Model Rated ESP. Max. ESP Rated CFM 2 Optional CFM 3 Continuous CFM 4 Dehumidification CFM 5 CFM @ Max ESP QA24.. 5 N/ A 5 7 QA3.5. N/ A 7 9 QA3.5. 2 5 75 QA42.5. 2 5 75 QA4.2. 4 5 75 QA.2. 55 4 Note: These units are equipped with a variable speed (ECM) indoor motor that automatically adjusts itself to maintain approximately the same rate of indoor airflow in both heating and cooling, dry and wet coil conditions and at both 23/2 or 4 volts. Max. ESP (inches WC) shown is with " thick disposable filter (reduced by.2 for 2" filter) 2 Rated CFM (based on ducted application) for heating and cooling operation. To obtain full rated CFM on models QA3, QA42, QA4, and QA, refer to installation instruction supplied with unit. 3 Reduced indoor airflow option to provide lowest possible indoor air sound level. Reduces system capacity performance by approximately 2%. 4 Continuous fan CFM is the total air being circulated during continuous fan mode. 5 Indoor airflow during periods of high humidity when system is operating under control of optional humidistat for maximum humidity reduction. Model QA24 when operating on 2nd stage heating the indoor air will increase to cfm. Ventilation System Packages QTec models are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a barometric fresh air damper as the standard ventilation package. All ventilation packages are factory installed. BAROMETRIC FRESH AIR DAMPER STANDARD The barometric fresh air damper is a standard feature on all models. It allows outside ventilation air, up to % of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The damper opens during blower operation and closes when the blower is off. Adjustable blade stops allow different amounts of outside air to be introduced into the building and can be easily locked closed if required. BLANK OFF PLATE OPTIONAL A blank off plate covers the air inlet openings which restricts any outside air from entering the unit. The blank off plate should be utilized in applications where outside air is not required to be mixed with the conditioned air. NOTE: The above vent systems are intake only without builtin exhaust capability. Building will likely require separate field installed barometric relief or mechanical exhaust elsewhere within the conditioned space. Balancing dampers in the return air grille may be required to achieve specified amount of outdoor air intake. COMMERCIAL ROOM VENTILATOR OPTIONAL The builtin commercial room ventilator is internally mounted and allows outside ventilation air, up to 5% of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a builtin exhaust air damper. The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field controlled based on room occupancy. Complies with ANSI/ASHRAE Standard 2. Ventilation for Acceptable Indoor Air Quality. Two Models Available: Spring return on power loss or deactivation Power return (will not close on power loss) ENERGY RECOVERY VENTILATOR OPTIONAL The energy recovery ventilator (ERV) is a highly innovative approach to meeting indoor air quality ventilation requirements as established by ANSI/ASHRAE Standard 2.. The ERV is internally mounted and allows up to 45 CFM (depending upon speed setting) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 4% during summer and 79% during winter conditions. The ERV consists of a unique rotary energy recovery cassette that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only. The ERV has a filter for the exhaust air to keep the rotary wheels clean and free of any debris introduced through the room return air grille. The intake and exhaust rates can be independently selected. Factory set on medium intake and low exhaust. ECONOMIZER OPTIONAL The builtin economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a builtin exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. Standard Features: One Piece Construction Easy to install with no mechanical linkage adjustment required. Exhaust Air Built in with positive closed position. Provides exhaust air capability to prevent pressurization of tight buildings. Actuator Motor 24 volt, power open, spring return with built in torque limiting switch. Proportioning Type Control for maximum free cooling economy and comfort. Moisture Eliminator & Prefilter permanent, washable aluminum construction. Enthalpy Control adjustable to monitor outdoor temperature and humidity. Minimum Potentiometer adjustable to control minimum damper blade position for ventilation purposes. Mixed Air Sensor to monitor outside and return air to automatically modulate damper position. Form No S3329 Supersedes S3397 Page 7 of 2

Commercial Room Ventilator Performance Tables QH242 VENTILATION MODE CFM TABLE.. 3. 5 A 2 75 B 3 5 C 5 4 D 5 5 2 95 E 375 32 29 25 QH242 COOLING & HEATING MODE CFM TABLE 2.. 3. 5 A 22 2 75 B 245 2 2 5 C 5 2 245 2 D 3 3 33 29 E 3 32 TABLE 3 QH32 Ventilation Mode CFM QH32 Ventilation Mode CFM QH422 Ventilation Mode CFM QH42 Ventilation Mode CFM.. 2. 3 A 4 2 B 7 C 22 2 95 D 29 E 4 4 3 QH32 COOLING & HEATING MODE CFM QH32 LOW SPEED COOLING & HEATING MODE CFM QH422 LOW SPEED COOLING & HEATING MODE CFM QH42 LOW APEED COOLING & HEATING MODE CFM TABLE 4.. 3. 5 A 2 23 2 22 B 25 245 24 C 3 3 29 D 4 4 39 3 E 45 4 445 43 QH32 HIGH SPEED COOLING & HEATING MODE CFM QH422 HIGH SPEED COOLING & HEATING MODE CFM QH42 HIGH SPEED COOLING & HEATING MODE CFM TABLE 5.. 3. 5 A 5 23 B 2 2 2 C 3 3 345 D 445 445 445 44 E 5 5 5 49 QH2 VENTILATION MODE CFM TABLE.. 3. 5 A 5 5 B 2 2 C 29 29 2 275 D 37 37 35 E 45 45 455 445 QH2 COOLING & HEATING MODE CFM TABLE 7.. 3. 5 A 2 23 23 B 25 2 5 5 C 345 34 D 47 47 455 45 E 5 57 55 5 NOTE: Ventilation airflow will increase up to 5 CFM during backup or emergency heat operation due to increased total airflow. Form No S3329 Supersedes S3397 Page of 2

Energy Recovery Ventilator Performance Tables Ambient O.D. DB/WB DegreesF VLT VENTILATION RATE 45 CFM 5% Efficiency VLS VLL HRT SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS 75 DB / 2 WB) HRS HRL VENTILATION RATE 375 CFM % Efficiency 7 22 22 29 29 293 293 793 793 2 75 5 42 42 274 274 43 43 233 233 2 LEGEND VLT = Ventilation Load Total HRT = Heat Recovery Total VLS = Ventilation Load Sensible HRS = Heat Recovery Sensible VLL = Ventilation Load Latent HRL = Heat Recovery Latent VLT VLS VLL HRT HRS 5 75 7 5 245 45 45 45 45 45 4 3952 9477 9477 9477 9477 9477 4475 77 5737 5 9 944 33 797 2 23 2 7374 2 75 245 934 3952 797 54 77 772 5 2 7 22 22 29 797 3 293 793 2 5 797 797 2 2 797 797 2 2 9 972 27 33 3 4 23 2 7374 5345 75 245 972 744 3952 3 734 77 977 5 5345 95 7 22 972 232 29 3 7 293 293 793 5345 5 972 972 3 3 5345 5345 972 972 3 3 5345 5345 9 729 243 33 473 5794 23 75 2 7374 49 75 245 729 475 3952 473 923 77 75 2 5 49 9 7 22 729 52 29 473 329 293 75 42 793 49 5 729 729 473 473 75 75 49 49 729 729 473 473 75 75 49 49 9 4 273 33 9 7374 23 45 22275 7374 272 75 245 4 5 3952 9 793 77 45 337 5 272 5 7 22 4 7492 29 9 47 293 45 243 793 272 5 4 4 9 9 45 45 272 272 4 4 9 9 45 45 272 272 75 245 243 9 3952 579 2372 77 2 52 5 33 7 22 243 9922 29 579 449 293 2 2 793 33 5 42 243 22 274 579 4 43 2 5 233 33 243 243 579 579 2 2 33 33 HRL VLT 37 43 972 972 92 2 523 43 2 22 2 459 43 447 2 4 4 335 2 779 43 274 2 4 4 47 2 932 43 42 2 324 324 49 43 5457 2 2 2 2 VENTILATION RATE 3 CFM 7% Efficiency VLS 972 972 972 4 4 4 4 4 4 4 4 4 4 324 324 324 324 324 2 2 2 2 VLL 459 29 2 45 73 755 2 945 3375 72 7 4995 29 5 2 2 HRT HRS 957 52 52 52 52 52 4 5427 957 5427 557 5427 5427 5427 5427 5427 4 434 957 434 557 434 434 434 434 434 4 3 957 3 557 3 3 3 3 3 4 27 957 27 557 27 27 27 27 27 957 5 557 5 99 5 5 5 557 99 HRL 375 3 4 9 97 524 75 54 33 22 939 74 334 52 4432 4 557 99 Ambient O.D. DB Degrees F NOTE: WINTER HEATING PERFORMANCE (INDOOR DESIGN CONDITIONS 7 F DB) VENTILATION RATE 45 CFM % Eff. 375 CFM % Eff. 3 CFM 2% Eff. WVL WHR WVL WHR WVL WHR 5 243 944 2 4 2 32 4 3 45 32 324 25 55 729 532 75 492 4 395 5 972 777 5 4 533 45 972 2 42 4 45 4 94 972 797 7 3 475 4 34 929 3 944 5552 2 322 29 27 27 749 2 472 45 955 2 243 944 2 42 2 324 5 273 234 22275 42 72 42 Sensible performance only is shown for winter application. LEGEND WVL = Winter Ventilation Load WHR = Winter Heat Recovery Form No S3329 Supersedes S3397 Page 9 of 2

Form No S3329 Supersedes S3397 Page of 2 This page intentionally left blank.

QSPSeries Sound Plenum The QSP3 QSP5 Series Sound Plenum has been designed for use with ALL Bard QTec Series units, both Generation I and Generation II systems. Installation is quick and easy with removal/replacement of six existing screws from the unit cabinet. Once installed the sound plenum enhances the current quiet operation of the QTec Series units, and the hinged door with cam locks provides easy access to the basic QTec system. Model selection is based on equipment cabinet size and finish. Sound Plenum Pt# Cabinet Finish Equipment Selection QSP34 QSP3V QSP54 QSP5V Painted Steel Gray QH2442 Texture Vinyl QH2442 Painted Steel Gray QH4 Texture Vinyl QH4 Front Panels Slate Finish, Side Panels Platinum Gray matching Qtec vinyl cabinet finishes. Features: Two Plenum Finishes To Match Unit Cabinets o Vinyl or Painted Steel Compatible With New or Existing Units Removable Cam Lock Hinge Doors Easy Unit Service Access Sound Absorbing Insulation Reduces Equipment dba Operating Levels o Up to 5 dba with Energy Recovery Ventilator option. o Provides general muffling of basic unit operation. Actual sound reduction may vary depending on system operating conditions and other site variables. MIS227 Form No S3329 Supersedes S3397 Page of 2

Q/Tec TM Model Nomenclature QA 42 A X X V X X X MODEL NUMBER QA Q/TEC Model CAPACITY 24 2 Ton 3 2½ Ton 3 3 Ton 42 3½ Ton 4 4 Ton 5 Ton VOLTS & PHASE A 23/2// B 23/2//3 C 4//3 KW Z KW 5 5KW KW 9 9KW KW 2 2KW 5 5KW VENTILATION OPTIONS X Barometric Fresh Air (Standard) B Blankoff Plate E Economizer (Not available on dehumidification versions) P Commercial Ventilator Motorized w/exhaust Power Return V Commercial Ventilator Motorized w/exhaust Spring Return R Energy Recovery Ventilator w/independent Intake & Exhaust Control FILTER OPTIONS X inch Fiberglass (Standard) F 2 inch Fiberglass P 2 inch Pleated COIL OPTIONS X Standard Phenolic coated evaporator* 2 Phenolic coated condenser 3 Phenolic coated evaporator and condenser coil* *and reheat if applicable INTERNAL CONTROLS X Standard High Pressure Switch Compressor Control Module w/time Delay G Low Pressure Control + Above J Alarm Relay + LAC + Above NOTE: Climate control option X, E or G must be ordered in conjunction with the dehumidification circuit. If X control option is selected, humidistat must be field supplied. For CS2A2 applications order X control option for field supplied and installed thermostat and humidistat, or G control option for factory installed electronic nonprogrammable/man or Auto C/O thermostat and humidistat. G option can be used without CS2A2 only if X or B ventilation option is used unless other control provisions are field supplied to limit ventilation to occupied periods. 2 Insert D for dehumidification with hot gas reheat. Reference Form F for complete details. Required Field Installed Accessories One Size/Color Must Be Used For Each Installatio n Outdoor Louver Grilles: Q LG (for 2 3½ Ton Models) QLG5 (for 4 5 Ton Models) Clear Anodized Aluminu m Q LG2 (for 2 3½ Ton Models) QLG (for 4 5 Ton Models) Medium Bronze Anodized Aluminu m Q LG3 (for 2 3½ Ton Models) QLG (for 4 5 Ton Models) Dark Bronze Anodized Aluminu m Wall Sleeves: Note Maximum dimension in inches of wall is shown ( ) F or all 2 through 3½ ton units Q WS42A (4") Q WS42A (") Q WS42A9 (9") Q WS42A2 (2") Q WS42A23 (23") QWS42A3 (3") F or all 4 through 5 ton units Q WS4A (4") Q WS4A (") Q WS4A9 (9") Q WS4A2 (2") Q WS4A23 (23") QWS4A3 (3") Optional Field Installed Accessories Additional Items As Determined By Job Specification s Drain Kit: QCDS4A REVISION SPECIALTY PRODUCTS 2 (NonStandard) Rear condensate drain system allows easy removal of unit from wall sleeve. COLOR V Platinum w/slate Front (Vinyl) 4 CLIMATE CONTROL X None A Electronic/Non Prog D Electronic/Prog E Electronic/Prog/Humidistat G Electronic NonProg/Humidistat NOTE: J module available on X climate control option only. Fits all models. QPBHW42DV QPBHW4DV NOTE: NOTE: The following accessory items must be selected so that the finish (color) is matched to the QAmodel that they will be used with. Side Trim Extension Kits: Required when wall thickness is less than ½ inches and works for walls down to inches thick. Used in place of standard trim kit supplied with unit to cover the space between unit and wall. QSTX42AV QSTX42A4 FreeBlow Plenum Boxes: QPB42V QPB424 Front supply, 4way deflection grille QPBS42V QPBS424 Same as QPB42, plus 2way deflection grille on each side QPB4V QPB44 Front supply, 4way deflection grille QPBS4V QPBS44 Same as QPB4, plus 2way deflection grille on each side Top Fill Systems for Finishing Plenum Boxes to Ceilings: QPBX429V QPBX4294 G ray paint Use with QPB42 or QPBS42 (adjusts to ceilings up to 9' " ) QPBX42V QPBX424 G ray paint Use with QPB42 or QPBS42 (adjusts to ceilings up to ' 2" ) QPBX49V QPBX494 G ray paint Use with QPB4 or QPBS4 (adjusts to ceilings up to 9' " ) QPBX4V QPBX44 G ray paint Use with QPB4 or QPBS4 (adjusts to ceilings up to ' 2" ) Cabinet Extensions for Ducted Applications: QCXAV QCXA4 2" height (adjusts for ceilings up to 9' 4"; add QPBX429 for 9'4" to ' finished ceiling heights) QCX5AV QCX5A4 2" height (adjusts for ceilings up to 9' 4"; add QPBX49 for 9'4" to ' finished ceiling heights) Hot Water Coils with Plenum Boxes: QPBHW42FV QPBHW42F4 FreeBlow plenum box QPBHW4FV QPBHW4F4 FreeBlow plenum box QPBHW42D4 QPBHW4D4 Ducted plenum box Ducted plenum box The same top fill system and cabinet extensions can be used with hot water coil plenum boxes as with standard plenum boxes. Unit Compatibilit y All models Unit Compatibilit y 2 3½ To n 2 3½ To n 4 5 To n 4 5 To n Unit Compatibilit y 2 3½ To n 2 3½ To n 4 5 To n 4 5 To n Unit Compatibilit y 2 3½ Ton 4 5 Ton Unit Compatibilit y 2 3½ To n 4 5 To n 2 3½ To n 4 5 To n Form No S3329 Supersedes S3397 Page 2 of 2 Bard Manufacturing Company, Inc. Bryan, Ohio 4 www.bardhvac.com Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. S33 February, 29 Supersedes S3397