Self-Contained & Split System Reverse Cycle Air Conditioners s 05-07-10-12-16-18-24 General Description Marvair's water source self-contained and split system reverse cycle air conditioners are designed for use in either fresh or salt water. These units are built in capacities of 5,000; 7,000; 10,000; 12,000; 16,000; 18,000 and 24,000 TUH. The self-contained units are complete packaged units, factory charged and wired. The split systems are comprised of two parts, a condensing section comprised of the compressor section and the air handler SP16RC-00 section. Field installed refrigerant tubing and wiring connects the two sections. Units are available for operation on 115V, 60 Hz; 208/230V, 60 Hz and 220/240V, 50 Hz. The units are built using R-22, R407C or R410A refrigerant. oth R407C and R410A are environmentally friendly, nonozone depleting and accepted DEAH07RC & CU07RC for use throughout the European Community. The reverse cycle air conditioners feature rotary and scroll compressors with a suction line accumulator and high and low refrigerant pressure switches. The coaxial tube-in-tube condenser is constructed of corrosion resistant cupronickel water tubing and copper refrigerant tubing. To ensure years of dependable performance, the units feature: A stainless steel base pan with multiple condensate drain openings allows the rapid disposal of condensate. The base pan is embossed to add rigidity and to keep the components out of the condensate. An insulated pad minimizes movement and sound. On the split systems, the compressor section and the air handler are mounted in a stainless steel trays. Structural supports and control box constructed of superior corrosion resistant aluminum. The aluminum is primed and then a white heat cured polyester finish is applied for the optimum in durability and aesthetics. A five foot long (151 cm), heavy duty multiwire cable harness facilitates the remote mounting of the control box. This complete cable assembly seals all the wires into the harness to minimize the chance of corrosion. The evaporator coil is constructed of lanced fins and rifled copper tubing for optimum heat transfer. The coil has a baked polyester enamel finish - no paint - and is rated to 1,000 hours when tested to ASTM 117. A compact, motorized impeller type blower moves the conditioned air quietly and efficiently through duct work. ackward curved, corrosion resistant centrifugal fans feature extremely long blades for high efficiency and low noise. Maintenance free ball bearings never need oiling. All units are built to the requirements of UL standard 484, 7th Edition. Marvair is an ISO 9001-2000 registered company. All self contained and split systems units (unless designated otherwise) meet applicable AYC and US Coast Guard regulations, CE directives and all applicable Air Conditioning and Refrigeration Institute standards. 1 Self Contained_Split PD 6/09-9 supercedes 9/08-8
Installation Installation on both self contained and split system units is simplified with a readily accessible terminal strip for both the power and control (low voltage) wiring. The control box is located on the side of the self contained units and in the compressor section of the split systems. However, the control box can be easily mounted on the opposite side or on the top of the unit or even remotely mounted on a bulkhead. A five foot (151 cm) multiwire cable harness provides a durable and quick electrical connection between the unit and the control box. Condensate line ports (5/8 nylon tube) on both ends and both sides of the base pan facilitate the drain line connections. Factory provided hold-down clamps are included. On the split system units, threaded refrigerant connections on both the compressor section and the air handler eliminate the need for a braising. The compressor section is shipped with a holding charge and, in many cases, no additional refrigerant is required. Thermostats All units can be controlled by either the MachAir II OLED or the MachAir I thermostat/controller. The MachAir II OLED and the MachAir I thermostat/controller display shows whether the unit is in the heating or cooling or fan only or dehumidification mode, set point temperature ( F or C), cabin temperature ( F or C) and fan indicator. The cooling or heating can be selected manually or the Auto mode selects whichever is required automatically. The fan speed can be controlled automatically or manually. Includes wall mounted controller/ display. See the MachAir II OLED Product Data Sheet for complete information on the MachAir II OLED thermostat/controller. Accessories Accessories are required and ordered separately. Sea Water Pump Kit. Air duct, supply grille(s) and return grille. Plumbing fittings. Thermostat/controller. Identification - Self-Contained Units P S S = Marine Refrigerant P = R22 C = 407C A = R410A Controller = Electronic Control oard Nominal 05 = 5,000 TUH 07 = 7,000 TUH 10 = 10,000 TUH 12 = 12,000 TUH 16 = 16,000 TUH 18 = 18,000 TUH 24 = 24,000 TUH System Type AC = Air Conditioner RC = Reverse Cycle A = 208/230V, 1ø, 60 Hz = 115V, 1ø, 60 Hz F = 220/240V, 1ø, 50 Hz Note: 18,000 TUH models are only available with 60 Hz units. Identification - Split System Condensing Section Orientation* L = Left Hand R = Right Hand C Electronic Thermostat/ Controller M2 = MachAir II oard Marine Refrigerant P = R22 C = 407C A = R410A Controller = Control oard Note: 18,000 TUH models are only available with 60 Hz units. Nominal 07 = 7,000 TUH 10 = 10,000 TUH 12 = 12,000 TUH 16 = 16,000 TUH 18 = 18,000 TUH 24 = 24,000 TUH System Type AC = Air Conditioner RC = Reverse Cycle A = 208/230V, 1ø, 60 Hz = 115V, 1ø, 60 Hz F = 220/240V, 1ø, 50 Hz Identification - Split System Air Handler Section DEAH Electronic Thermostat/ Controller M2 = MachAir II oard Direct Expansion Air Handler Nominal 07 = 7,000 TUH 10 = 10,000 TUH 12 = 12,000 TUH 16 = 16,000 TUH 18 = 18,000 TUH 24 = 24,000 TUH System Type AC = Air Conditioner RC = Reverse Cycle A = 208/230V, 1ø, 60 Hz = 115V, 1ø, 60 Hz F = 220/240V, 1ø, 50 Hz Orientation* L = Left Hand R = Right Hand * When looking at the compressor from the end of the unit, if the coil is on your right side, the unit is a right handed unit. If the coil is on your left, it is a left handed unit. Self Contained_Split PD 6/09-9 2
Water Flow Chart Water Flow* for Reverse Cycle Systems (TUH) Water Flow at the Unit 5,000 1.4 GPM / 5.3 LPM 7,000 2.0 GPM / 7.6 LPM 10,000 2.9 GPM / 11.0 LPM 12,000 3.5 GPM / 13.3 LPM 16,000 4.7 GPM / 17.8 LPM 18,000 5.25 GPM / 19.9 LPM 24,000 7.0 GPM / 26.5 LPM * ased upon 85 F (29.5 C) inlet water measured at the inlet of the unit. Air Flow and Grille Chart Self Contained Unit or Air Handler Nominal Air Flow CFM/m 3 per Hour Opening for Return Air Grille (in 2 /cm 2) Opening for Supply Air Grille(s) (in 2 /cm 2) Hose Size (in/cm) Marvair P/N for lower to Hose Adapters Outside Diameter of Hose Adapter (in/cm) 5,000 150/255 64/415 32/210 4/10.2 7,000 250/425 100/645 40/260 5/12.7 Not required. Not required. lower has 4" lower has 4" (10.2cm) round (10.2cm) round diameter opening. diameter opening. 901341 (5" round hose adapter) 4-3/4" (12cm) 10,000 300/510 100/645 60/390 5 or 6*/ 12.7 or 15.2* 90134 (5" round hose adapter) or 90135 1 (6" round hose adapter) 4-3/4" (12 cm) or 5-3/4" (14.6 cm) 12,000 360/612 140/900 70/450 6/15.2 90135 1 (6" round hose adapter) 5-3/4" (14.6 cm) 16,000 385/654 168/1,110 84/540 6 or 7*/ 15.2 or 17.8* 90135 (6" round hose adapter) or 90136 1 (7" round hose adapter) 5-3/4" (14.6 cm) or 6-3/4" (17.15cm) 18,000 420/714 168/1,110 84/540 7/17.8* 90136 1 (7" round hose adapter) 6-3/4" (17.15cm) 24,000 700/1,190 240/1,550 192/1,240 8* or 10/ 20.3* or 25.4 90568 2 (8" oval hose adapter) 10" x 4" (25.4 x 10.2 cm) * Use larger size if duct run is greater than 10 ft. (3 meters). 1 Shipped standard with unit. 2 Two adapters are shipped with each two ton unit. 3 Self Contained_Split PD 6/09-9
Performance/Electrical Data for Self-Contained Units - s SP, 60 Hz, R-22 Refrigerant Performance/Electrical Data for Self-Contained Units - s SP, 50 Hz, R-22 Refrigerant Circuit Ampacity reaker (amp) (TUH) (kg) Refrig. SP*05F 5,000 220 50 2.9 10.1 3.5 10 19 R-22 SP*07F 7,000 220 50 3.8 13.4 4.7 10 25 R-22 SP*10F 10,000 220 50 4.8 16.8 5.9 10 29 R-22 SP*12F 12,000 220 50 6.1 21.3 7.5 10 30 R-22 SP*16F 16,000 220 50 7.3 25.4 8.9 15 30 R-22 See Performance/Electrical Data for Self-Contained units - SA24, 60 Hz, R410A Refrigerant. Performance/Electrical Data for Self-Contained Units - s SC, 50 Hz, R-407C Refrigerant Circuit Ampacity reaker (amp) (TUH) (kg) Refrig. SC*05F 5,000 220 50 2.9 10.1 3.5 10 19 R-407C SC*07F 7,000 220 50 3.5 12.1 4.2 10 25 R-407C SC*10F 10,000 220 50 4.8 16.8 5.9 10 29 R-407C SC*12F 12,000 220 50 6.1 21.3 7.5 10 30 R-407C SC*16F 16,000 220 50 7.3 25.4 8.9 15 30 R-407C See Performance/Electrical Data for Self-Contained units - SA24, 60 Hz, R410A Refrigerant. 1 Amps will vary with actual voltage, inlet water temperature and inlet air temperature and humidity. Amps will be approximately 50% higher in the heating mode. Circuit Ampacity reaker (Amp) (TUH) (Lbs) Refrig. SP*05 5,000 115 60 5.33 18.7 6.5 10 41 R-22 SP*07 7,000 115 60 6.67 23.4 8.1 15 55 R-22 SP*07A 7,000 230 60 3.4 11.8 4.1 10 55 R-22 SP*10 10,000 115 60 7.5 26.4 9.1 15 63 R-22 SP*10A 10,000 230 60 5.0 17.5 6.1 10 63 R-22 SP*12 12,000 115 60 9.8 34.5 12.0 20 66 R-22 SP*12A 12,000 230 60 5.3 18.6 6.5 10 66 R-22 SP*16 16,000 115 60 12.0 42.0 14.6 20 67 R-22 SP*16A 16,000 230 60 6.8 23.6 8.2 15 67 R-22 SP*18 18,000 115 60 16.0 56.1 19.6 30 68 R-22 SP*18A 18,000 230 60 8.0 27.9 9.7 15 68 R-22 See Performance/Electrical Data for Self-Contained units - SA24, 60 Hz, R410A Refrigerant. Performance/Electrical Data for Self-Contained Units - SA24, R-410A Refrigerant Circuit Ampacity reaker (amp) (TUH) (kg) Refrig. SA24RCF 24,000 220/240 50 13.34 16.00 16.5 25.0 50 R-410A SA24RCA 24,000 208/230 60 14.30 19.20 17.7 30.0 50 R-410A Self Contained_Split PD 6/09-9 4
Dimensional Data - Self-Contained 05 (inches & mm) LEFT HAND UNIT REMOTE CONTROL OX 5-7/8 [149mm] 2-11/16 [68mm] FILTER A Marvair A 8-1/2 [215mm] COMPRESSOR HEAT EXCHANGER 10-1/8 [256mm] LOWER 16-1/8 [409mm] 17-7/8 [455mm] FRONT VIEW SIDE VIEW USHING SCHEDULE MK QTY ID 15/16 [25 mm] 11/16 [20 mm] WATER OUT 5/8" O.D. (15.8 MM) ACK VIEW LOWER OPENING 4" (102mm) O.D. WATER OUT FRONT VIEW 9-15/16 [252mm] 10-1/2 [268mm] WATER IN 12-1/8 [307mm] WATER IN 5/8" O.D. (15.8 MM) 2-1/2 [64mm] CONDENSATE FITTING.563 O.D. (14.2 MM) (TYPICAL) For 5/8" (14.2mm) condensate tubing. FOAM PAD 1/2" (13mm) WEIGHT: 41 LS / 19 KG NOTE: THE ELECTRICAL CONTROL OX FOR ALL 5,000 MODELS IS ALWAYS REMOTELY MOUNTED. 5 Self Contained_Split PD 6/09-9
Dimensional Data - Self-Contained s 07-10-12-16-18 (inches & mm) LOWER IN POSITION FOR VERTICAL DISCHARGE CONTROL OX 5/8" (15 mm) OD 8-3/4" 222 mm ACK (LOWER) VIEW 7" 178 mm 5/8" (15 mm) OD RIGHT HAND UNIT FRONT (EVAPORATOR) VIEW 13" 330 mm 1/2" 13 mm 1/2" / 13 mm CLOSE CELL INSULATION RIGHT SIDE VIEW LEFT SIDE VIEW 14-1/8 359 mm 3-1/4 83 mm CONTROL OX 1 25 mm 13-1/2" 343 mm 10-1/8 257 mm CONTROL OX 2-3/4" / 70 mm For 5/8" (14.2mm) condensate tubing DIMS A C D E F G H I J K L WT. 07 21-1/4" (540mm) 12-1/4" (311mm) 22-3/8" (568mm) 3-1/2" (89mm) 9-1/8" (232mm) 10-7/8" (276mm) 7-1/2" (191mm) 9" (229mm) 10" (254mm) 4" (102mm) 9" (229mm) 55 Lbs (25 kg) 10 22-7/8" (581mm) 13-5/8" (346mm) 24-1/2" (622mm) 3-3/8" (86mm) 13" (330mm) 7" (178mm) 9-3/4" (248mm) 10-3/4" (273mm) 3-1/2" (89mm) 10-3/8" (264mm) 63 Lbs (29 kg) 12 22-7/8" (581mm) 13-7/8" (352mm) 24-3/4" (629mm) 3-3/8" (86mm) 13" (330mm) 7" (178mm) 9-3/4" (248mm) 10-3/4" (273mm) 3-1/2" (89mm) 10-3/8" (264mm) 66 Lbs (30 kg) CONTROL OX DIMENSIONS - 11 x 3-1/2 x 6-1/4"(279 x 79 x 159 mm) 16 23-3/4" (603mm) 13-5/8" (346mm) 25-3/4" (654mm) 3-3/8" (86mm) 11-1/2" (292mm) 13-1/8" (333mm) 6-3/4" (171mm) 9-3/8" (238mm) 10-1/2" (267mm) 3-1/2" (89mm) 10-1/8" (257mm) 67 Lbs (30 kg) 18 23-3/4" (603mm) 13-5/8" (346mm) 25-3/4" (654mm) 3-3/8" (86mm) 11-1/2" (292mm) 13-1/8" (333mm) 6-3/4" (171mm) 9-3/8" (238mm) 10-1/2" (267mm) 3-1/2" (89mm) 10-1/8" (257mm) 68 Lbs Self Contained_Split PD 6/09-9 6
Dimensional Data - Self-Contained 24 (inches & mm) CONTROL OX 5-7/8 [149] 2-11/16 [68] A MARVAIR A 10-1/8 [256] LEFT SIDE VIEW FRONT VIEW USHING SCHEDULE MK QTY ID 15/16 (25 mm) 11/16 (20 mm) RIGHT SIDE VIEW RIGHT HAND UNIT FILTER CONTROL OX RIGHT SIDE VIEW 10" x 4 " (254mm x 102 mm) OD OVAL ADAPTER (TYP.) COIL LOWER OX COMPRESSOR WRAP COIL 16-13/16 [427] 18 [457] 10" x 4 " (254mm x 102 mm) OD OVAL ADAPTER (TYP.) 29-3/16 [741] ACK VIEW LEFT SIDE VIEW WATER OUT 5/8" O.D. (15.8 MM) 14-9/16 [370] 16-13/16 [427] MARVAIR 1 [26] CONDENSATE FITTING.563 O.D. (14.2 MM) (TYP.) For 5/8" (14.2mm) condensate tubing CONTROL OX WATER IN 5/8" O.D. (15.8 MM) 14 [356] CONTROL OX WEIGHT: 111 LS / 50 KG There are two conditioned air outlet openings, one on the top and one on the right side. Each opening is a 9-7/8" x 4" (251mm x 102mm) oval opening. An oval adapter, Marvair part number 91568, should be used as a transition to duct on each opening. This adapter has an outside diameter of 10" x 4" ( 254 mm x 102 mm). For optimum performance, both openings must be used. Insufficient air flow can cause ice to form on the evaporator coil in the cooling mode and premature activation of the circuit breaker in the heating mode. 7 Self Contained_Split PD 6/09-9
Performance/Electrical Data for Split System Condensing Section, CP, 60 Hz, R-22 Refrigerant Current Amps Performance/Electrical Data for Split System Condensing Section, CC, 50 Hz, R-22 Refrigerant Current Amps 2 Condensing unit amps include one air handler. 3 Amps will vary with actual voltage. Self Contained_Split PD 6/09-9 8 reaker (Amp) (TUH),2 (Lbs/kg) CP/M07RC 7,000 115 60 6.7 23.4 8.1 15 39/18 CP/M07RCA 7,000 230 60 3.4 11.8 4.1 10 39/18 CP/M10RC 10,000 115 60 7.5 26.4 9.1 15 45/20 CP/M10RCA 10,000 230 60 5.0 17.5 6.1 10 45/20 CP/M12RC 12,000 115 60 9.8 34.5 12.0 20 47/21 CP/M12RCA 12,000 230 60 5.3 18.6 6.5 10 47/21 CP/M16RC 16,000 115 60 12.0 42.0 14.6 20 47/21 CP/M16RCA 16,000 230 60 6.8 23.6 8.2 15 47/21 CP/M18RC 18,000 115 60 16.0 56.1 19.6 30 48/22 CP/M18RCA 18,000 230 60 8.0 27.9 9.7 15 48/22 See Performance/Electrical Data for Split System Condensing Section, CA, 60 Hz, R-410A Refrigerant. reaker (amp) (TUH),2 (kg) CP/M07RCF 7,000 220 50 3.8 13.4 4.7 10 18 CP/M10RCF 10,000 220 50 4.8 16.8 5.9 10 20 CP/M12RCF 12,000 220 50 6.1 21.3 7.5 10 21 CP/M16RCF 16,000 220 50 7.3 25.4 8.9 15 21 See Performance/Electrical Data for Split System Condensing Section, CA, 60 Hz, R-410A Refrigerant. Performance/Electrical Data for Split System Condensing Section, CC, 50 Hz, R-407c Refrigerant Current Amps reaker (amp) (TUH),2 (kg) CC/M07RCF 7,000 220 50 3.5 12.1 4.2 10 18 CC/M10RCF 10,000 220 50 4.8 16.8 5.9 10 20 CC/M12RCF 12,000 220 50 6.1 21.3 7.5 10 21 CC/M16RCF 16,000 220 50 7.3 25.4 8.9 15 21 See Performance/Electrical Data for Split System Condensing Section, CA, 60 Hz, R-410A Refrigerant. Performance/Electrical Data for Split System Condensing Section - CA24, R-410A Refrigerant Electrical Data - DEAH, 50 Hz Circuit Ampacity reaker (amp) (TUH) (kg) Refrig. CA24RCF 24,000 220/240 50 13.34 16.00 16.5 25.0 36 R-410A CA24RCA 24,000 208/230 60 14.30 19.20 17.7 30.0 50 R-410A Unit (TUH) Volts Full Load Amps 3 (m 3 /hr) (kg) Air Flow DEAH07RCF 7,000 240 50 0.44 360 10 DEAH10RCF 10,000 240 50 0.58 495 11 DEAH12RCF 12,000 240 50 0.58 495 12 DEAH16RCF 16,000 240 50 0.86 580 12 DEAH24RCF 24,000 240 50 0.86 968 20 F = 220/240V 1 Amps will vary with actual voltage, inlet water temperature and inlet air temperature and humidity. Amps are approximately 50% higher in the heating mode.
Electrical Data - DEAH, 60 Hz Unit (TUH) Volts Full Load Amps 3 Air Flow (CFM) (Lbs/kg) DEAH07RC 7,000 115 60 0.85 250 22/10 DEAH07RCA 7,000 230 60 0.44 250 22/10 DEAH10RC 10,000 115 60 1.14 300 25/11 DEAH10RCA 10,000 230 60 0.58 300 25/11 DEAH12RC 12,000 115 60 1.14 360 26/12 DEAH12RCA 12,000 230 60 0.58 360 26/12 DEAH16RC 16,000 115 60 1.75 385 27/12 DEAH16RCA 16,000 230 60 0.86 385 27/12 DEAH18RC 18,000 115 60 1.95 400 27/12 DEAH18RCA 18,000 230 60 0.94 400 27/12 DEAH24RCA 24,000 230 60 0.86 700 44/20 = 115V A = 230V 3 Amps will vary with actual voltage. Split System Air Handler s 07-10-12-16-18 Dimensional Data (inches/mm) & (lbs/kg) CONDENSATE FITTING.563 O.D. (14.2 MM) (TYPICAL) For 5/8" (14.2mm) condensate tubing. FRONT VIEW SIDE VIEW SIDE VIEW Dimensions - inches(mm) H L W Lbs(kg) DEAH07RC 11.50 (292) 12.88 (327) 11.03 (280) 22 (10) DEAH10RC 13.50 (343) 14.88 (378) 11.03 (280) 25 (11) DEAH12RC 13.50 (343) 14.88 (378) 11.03 (280) 26 (12) DEAH16RC 13.50 (343) 15.38 (391) 11.03 (280) 27 (12) DEAH18RC 13.50 (343) 15.38 (391) 11.03 (280) 27 (12) Note: 18,000 TUH models are only available with 60 Hz units. 9 Self Contained_Split PD 6/09-9
Split System Condensing Section s 07-10-12-16-18 Dimensional Data (inches/mm) & (lbs/kg) 8-3/4" 222mm W (OX) SeaMach 2-5/8" 67mm H 10-1/8" 257mm L FRONT VIEW W (PAN) SIDE VIEW 39 (18) 45 (20) 47 (21) 47 (21) 48 (22) Self Contained_Split PD 6/09-9 Note: 18,000 TUH models are only available with 60 Hz units. 10
Split System Condensing Section 24 Dimensional Data (in./mm) 15.9mm 357mm 9.5mm 531mm ISOMETRIC VIEW 15.9mm 257mm 446mm 15.9mm FRONT VIEW 360mm WEIGHT: 79 LS / 36 KG SIDE VIEW 11 Self Contained_Split PD 6/09-9
Split System Air Handler Section 24 Dimensional Data (in./mm) SUCTION LINE 15.9mm 5/8" FLARE 102 mm 4" CONDITIONED AIR DISCHARGE LIQUID LINE 9.5mm 3/8" FLARE 241mm 9 1/2" 588mm 23 1/8" TOP AND SIDE CONDITIONED AIR DISCHARGE 10 x 4 (254mm x 102mm) OD OVAL ADAPTER (EA) 437mm 17 3/16" WEIGHT: 44 LS / 20 KG CONDENSATE FITTING.563 O.D. (14.2 MM) (TYPICAL) For 5/8" (14.2mm) condensate tubing. 362mm 14 1/4" NOTE: There are two conditioned air outlet openings, one on the top and one on the right side. Each opening is a 9-7/8" x 4" (251mm x 102mm) oval opening. An oval adapter, Marvair part number 91568, should be used as a transition to duct on each opening. This adapter has an outside diameter of 10" x 4" ( 254 mm x 102 mm). For optimum performance, Marvair strongly recommends that both openings be used. Please consult the Marvair website at www.marvair.com for the latest product literature. Complete installation instructions are in the SeaMach Installation and Service Manual. Detailed dimensional data is available upon request. A complete warranty statement can be found in each product s Owner's Manual, on our website or by contacting Marvair at 229-273-3636. As part of the Marvair continuous improvement program, specifications are subject to change without notice. P.O. ox 400 Cordele, Georgia 31010 156 Seedling Drive Cordele, Georgia 31015 Ph: 229-273-3636 Fax: 229-273-5154 Email: marvair@airxcel.com www.marvair.com Self Contained_Split PD 6/09-9 12 Marvair Marine UK Unit 8 Arena usiness Centre Holyrood Close Poole, Dorset H17 7FL. +44 1202 606405 www.marvair.co.uk Marvair, Division of AIRXCEL, Inc. 6/09