incontrol Systems Inc. Flame and Gas Detection

Similar documents
Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Global Gas Detection and Monitoring Solutions

3M Oldham OLCT 100. Description. Fixed Gas Detector

OLC(T) 100 FIXED GAS DETECTOR

Products and performance

SIL 2. Ultima X Series Gas Monitors CERTIFIED

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

The Art of Gas Detection

Industrial Grade Gas Detection

Sieger Apex. Flexibility that meets your requirements

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Two-Channel Gas Controller

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Model D12-IR. Digital Gas Transmitter...

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Industrial Grade Gas Detection Detecting The Difference

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

GAS DETECTORS. When every second counts

Zareba Sensepoint Pro

MSA Gas Detection. for the Water and Wastewater Industries. Does your facility meet NFPA 820?

Dräger REGARD -1 Control System

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Recalibrate the way you look at gas detection

Warranty Registration

Model D12. Digital Gas Transmitter

Industrial Grade Gas Detection

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone:

Monitores Personales. Personal Monitor

SenSmart Universal Gas Detector Series

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Dräger Flame 2100 Flame Detection

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Dependable Solutions for Gas Detection

YOUR PARTNER IN FIRE & GAS DETECTION

ALTAIR 5X Multigas Detector Product Specification

Dräger Polytron Pulsar 2 Open Path Gas Detector

S5000 Gas Monitor. GMS5000.com

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Toxic Gas Detection. Model F12. Toxic Gas Detection

MSA Fixed Gas & Flame Detection for the Automotive Industry

Dräger Polytron 8310 IR Detection of flammable gases and vapour

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Dräger Polytron 5700 IR Detection of flammable gases and vapours

MSA Flame and Gas Detection. [ for the Oil, Gas and Petrochemical Industries ]

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Personal & Portable Gas Monitors

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

For the Safety of Your

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Dräger PointGard 2100 Detection of toxic gases and vapours

EXAMPLES OF HOW TO ORDER

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

EXAMPLES OF HOW TO ORDER

Transmitters/Sensors. OLCT Series

Equipment. Model R002. Description. SF6 leak detector

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Dräger Polytron 8000 Stationary gas detector (EC)

ST More than the sum of their components GAS DETECTION SYSTEMS

Dräger Flame 2500 (IR3) Flame Detection

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

HOW TO SPECIFY A DELPHIAN SYSTEM

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Better detection. Better protection. Fixed Gas & Flame Detection Product Overview - North America Region

INSTALLATION AND OPERATING INSTRUCTIONS

PRODUCT CATALOGUE. Gas & Air Quality Detectors Controllers Transmitters

M2A Transmitter Operator s Manual

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Fixed Gas Detectors Portable Gas Detectors Flame Detectors SmartWireless Control Solutions Gas Analyzers GF-00002A-EN

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Dräger Flame 2500 Flame Detection

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

RIG RAT III. Wireless Multi-Point Gas Detection System. The Stand-Alone Solution

Dräger X-am 7000 Multi-Gas Detection

VENTIS PRO SERIES. Product Guide

ULTIMA X5000. MSAX5000.com

Dräger Flame 2100 (UV) Flame Detection

Transcription:

incontrol Systems Inc. Flame and Gas Detection

Our flame and gas detectors are globally certified to the latest product approval standards Wherever toxic or combustible gases are part of an industrial process or a by-product of it, they pose a threat to people, property, and, productivity. incontrol Systems Inc. provides a complete line of rugged, reliable, stationary gas and flame detectors and various types of addressable and conventional controllers to serve as your first line of defense against gas and flame threats. Our Industrial line incorporates the full spectrum of sensing technologies (electrochemical, catalytic bead, open-path, and, point Infrared) for gas detectors and (Ultra-Violent, Infrared, Ultra-Violent/Infrared, and, Triple-Infrared) for flame detectors; We design, build, test, and commission complete flame and gas safety systems that range from conventional panels to faulttolerant, addressable systems. Our flame and gas detectors are globally certified to the latest product approval standards. Whether your need is to monitor gas hazards in a large area or several discrete locations from a convenient central site, incontrol Systems has a solution. Our products application include: Oil & Gas Petrochemicals & Refineries Chemical & Refrigeration Industries Power Plants Water & Wastewater Treatment Parking & Utility Rooms Commercial Sector Made in Canada

Gas Detectors Infrared Gas Transmitter / Sensor ICSIR-2000 Series Industrial strength smart sensor technology Specific % LEL or % volume of combustible gases RS-485, 4-20 ma and 0-10 VDC outputs Two 1 Amp SPDT form C relays Explosion proof, and duct mount enclosures Non-intrusive calibration and configuration with display unit Toxic Transmitter / Sensor ICST-1000 / ICST-2000 Series Industrial electrochemical sensing technology H2S, CL2, CL02, SO2, HCN, CO, NO2, HCL, NO, H2, NH3, O3, O2, ETO etc. detection 4-20 ma output Explosion proof, weather proof, duct mount and general purpose enclosures Non-intrusive calibration, optional relays and RS-485 Combustible Transmitter / Sensor ICSC-1200 / ICSC-2000 Series Industrial catalytic bead sensing technology CH4, C3H8, H2, C2H2, C2H6, C4H10, C5H12 etc. detection 4-20 ma output Explosion proof and duct mount enclosures Non-intrusive calibration, optional relays and RS-485 Commercial Toxic / Combustible Transmitter / Sensor ICS5 Series Smart sensor technology allows pre-calibrated replacement of sensors Uses electrochemical, Catalytic bead and infrared sensors Backlit 3 line display Displays concentration, relay status, STEL, TWA and daily peak value Keypad on front and scrolling of different functions 4-20 ma, 2-10 V, RS-485, Modbus, BACnet 3 on-board user programmable relays standard Non-intrusive calibration Nema 4X enclosure, splash guard and duct mount available Wall mount with knockouts (2 knockouts on back and every side) Sealed sensor housing Removable terminal blocks for ease of installation Commercial CO2 Transmitter / Sensor ICS-M10 Series Commercial infrared sensing technology CO2 range fully adjustable RS-485, 4-20 ma, 2-10 V outputs Two 1 amp SPDT form C Relays Wall or duct mount Push button controls for configurations

Controllers i-controller Series Accepts up to 30 RS-485 daisy chained sensors Accepts up to 8 of ANY 4-20 ma input Controls up to 99 DPDT form C relays Provides 8, 4-20 ma outputs Built-in LCD display and keypad Fully programmable, includes software Internet enabled, real time communications NEMA 1 or NEMA 4X enclosures i-controller Accessories i-switch, fully programmable and addressable manual relay overide switch i-logger, data logger with removable flash drive for concentrations and events for all transmitters and relays i-net, assigns an IP address to the i-controller for remote real time reading, programming and data logging i-rap Remote Annunciator Panel Display of gas concentration and relay status 4 fully addressable relays Separate horn, strobe and buzzer outputs Operates on RS-485 network Manual override of relays ICS4 Controller Four channel controller Display of concentration and relay status 4 fully addressable relays Separate on-board strobe, horn and buzzer outputs 4-20 ma retransmission available in averaging or peak modes Modbus output to external BAS

Flame Detection SharpEye Flame Detectors operate in the harshest environmental conditions and are self-contained, stand-alone devices. These devices are designed for direct connection to control and alarm systems or automatic fire extinguishing systems. 40/40 Series Flame Detectors The exciting new range of 40/40 SharpEye detectors offer enhanced reliability and durability with a massive 5-year warranty and an enhanced detection distance. 20/20 Series Flame Detectors The 20/20CTIx is a self-contained IR3 flame detector that also incorporates a color video camera. Thus the fire can be viewed and verified at a remote location. It detects a fire at up to 100 ft (30 m) in less than 10 seconds. The video signal output is available in either NTSC or PAL format. 20/20 Mini Flame Detectors The 20/20 range also includes Mini IR3 and Mini UV/IR detectors which offer a lower cost, lower power, compact design in a general purpose (non-ex approved) format. The 20/20MI IR3 is also available. Accessories incontrol Systems provides a range of accessories to ensure that your SharpEye Flame Detectors are installed and operating correctly. Open Path Gas Detectors We offer several open path solutions: Hydrocarbon The SafEye Series 700 and 200 Open Path Flammable Gas Detectors use our flash source technology to offer the highest reliability and availability with high immunity to false alarms from sunlight and stack flares. Toxic For toxic gas detection, we offer the SafEye Series 400 with flash source technology for the detection of Hydrogen Sulfide (H2S), Ammonia (NH3) and aromatic hydrocarbons. Accessories A Commissioning/Alignment Kit is needed on site to set-up and get your SafEye running, as well as for future checks. We also offer an I.S. approved hand-held unit.

incontrolsystemsinc. 75ShieldsCourt,Unit4,Markham Ontario,L3R9T4Canada Tel:+19054150400 inquiry@incontrolsystems.net www.incontrolsystems.net