K00364 Electronic Bin Thermostat

Similar documents
Demand Duo Principle of Operation:

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve

Safety & Installation Instructions

Model 1820 Dehumidifier

Digital Pail Heater Instruction Manual

CHR Inc. Custom Heaters & Research Digital Heating Jacket Instruction Manual

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Drop-In Refrigeration System

Safety & Installation Instructions

Model 76 Dehumidifier Control Installation Instructions

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com

For more Parts Information:

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

T-32-TS Touchscreen Thermostat. Installation Manual

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Safety & Installation Instructions

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

Installation Instructions

INSTALLER S & OWNER S MANUAL

PORTAGE & MAIN WOOD-FIRED OUTDOOR WATER FURNACE

Prodigy Plus - D Series Cuber Technical Review

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

INSTALLER S & OWNER S MANUAL

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

Smart Temp. Model

Model: Available in: Sapphire Black and Glacier White. 1 Series

MR3CCUHV Temperature/Defrost Control

Installation Instructions. Remanufactured Veeder-Root Overfill Alarm and. Acknowledgement Switch. Overfill Alarm PMP # OEM #

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Heat Pump Water Heater. Table of Contents

HOSHIZAKI AMERICA, INC. SERVICE BULLETIN

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

KIT NOTICE. These instructions are for replacing the three existing thermostats with a single new solid-state thermostat.

Refrigerated air dryers

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

Dixell Installing and Operating Instructions release 7.0

FOR SERVICE TECHNICIAN S USE ONLY

Installation Instructions

Model: Edge-HC. 1 edge-hc

CommStat 4 Controller

Installation & Service Manual

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Bottom Mount Refrigerator---Technical Information

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

Parts List. Modular Crescent Cuber. Models KM-515MAJ, MWJ, MRJ. hoshizakiamerica.com

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

Model 1870F Dehumidifier Installation and Operating Manual

Parts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com

Model: Available in : Sapphire Black and Glacier White. 1 Series

WARNING Important Safety Information

Powerblanket Thermostatic Controller (A421)

Model 1870 & 1870W Dehumidifier Installation Instructions

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

Parts List. Low-Profile Modular Crescent Cuber. Models KML-325MAJ KML-325MWJ. hoshizakiamerica.com

WARNING Important Safety Information

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

INSTALLATION INSTRUCTIONS TEC40 ELECTRONIC CONTROLLER

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

Installation Instructions

CM 3 Control System Update. Prodigy Cuber. Technical Review

Instruction Sheet

WARNING Important Safety Information

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

REACH-IN SAFETEMP (-AAC)

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

User s Manual

WARNING Important Safety Information

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

WARNING Important Safety Information

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

TECHNICAL SERVICE GUIDE

CAUTION. No-Load Performance, Controls in Normal Position

- Data Brochure Steam Control 279

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

FLCH4R Garage and Utility Electric Heater

TECH SHEET - DO NOT DISCARD PAGE

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

VX SERIES Wireless Thermostat with Occupancy Sensor

Rev This manual covers the following models: T771. Mounting and Battery Installation

Model GPT 3 Freeze Protection Thermostat

Transcription:

K00364 Electronic Bin Thermostat Installation Instructions This kit reduces overfill and condensation issues and can be used on any Manitowoc ice machine installed on an ice dispenser. Order kit number K00336 for the following models IB0620, IB0820, IB1020, QF0400 and QF2300. Control Settings Flake/Nugget/Chiplet: The control must be reset from the factory setting. Refer to the jumper and control settings. P4 Jumper The P4 jumper labeled Jump 1 is used to set the control for heating or cooling mode. Jump 2 is used to establish set point at either cut-in or cut-out. Ice Cube Machines: The machines use the factory control settings. The controller has a one-minute time delay anytime power is interrupted and restored. Positioning the Touchpad Jumpers Cubers Flake/Nugget/Chiplet P5 Jumper The P5 jumper position determines if the touchpad is locked or unlocked. The control is factory locked; to unlock, move the jumper from one pin to two pins. Setting Control Set point Value To view and adjust set point, follow these steps: RED SENSOR LEAD BLACK SENSOR LEAD MATCH WIRING TO ICE MACHINE VOLTAGE JUMPER LOCATIONS BIN SWITCH OR TOGGLE SWITCH A. Press MENU until the display flashes SP. B. Press MENU again to display the existing set point value. C. Press up or down (arrows) to change the set point value. D. Press MENU again to save the new value. The display returns to the sensed temperature. E. If no setup entry is made for 30 seconds, the control reverts to the normal temperature display. IMPORTANT: If MENU is not pressed after changing the set point value, the control reverts to the previously programmed set point value.

Manitowoc Ice, Inc. 2110 South 26 th Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA 8016563 Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879 Sheet 1 of 4 Web Site - www.manitowocice.com Rev. 03/14/06

Differential, Anti-Short Cycle Delay, Temperature Offset, or Sensor Failure Operation To set or verify the Differential, Anti-Short Cycle Delay, Temperature Offset or Sensor Failure Operation use the following method: Factory preset temperature control code settings, as follows: A. Press and hold MENU until the display changes to flashing SP. B. Press up and down (arrows) repeatedly until the desired function is displayed. C. Press MENU to display the function s current value. D. Press up and down (arrows) until the desired value is displayed. E. Press MENU to save the new value. The display returns to the sensor temperature. F. If no setup entry is made for 30 seconds, the control reverts to the temperature display. Any saved control settings are non-volatile and remain in the control s memory during power interruptions. Check Procedure WARNING Line voltage is present inside control. Contact with line voltage can cause serious injury or death. If the control system does not function properly, verify that the control is wired and set up properly. If the problem persists, use the following procedures to determine the cause of the problem 2. Fault Codes If the LCD displays an alarm or fault code (SF or EE): Fault Code Definition Solution SF flashing alternately with OP Open temperature sensor or sensor wiring See Step 3. Cycle power to reset control. SF flashing alternately with SH Shorted temperature sensor or sensor wiring See Step 3. Cycle power to reset control EE Program failure Reset the control by pressing MENU. If problem persists, replace the control. 3. Check for proper operation. IMPORTANT: Perform Steps 1 and 2 before performing these steps: A. Disconnect the load from the output relay terminals. B. Reconnect the sensor leads and supply power to the control. C. Replace the cover. D. Check the control settings for proper values. E. Press and hold MENU until SP appears. F. Press up and down (arrows) to change the set point temperature above and below the sensor temperature until the relay energizes and deenergizes. G. If the output relay does not perform as indicated, replace the control. H. If proper operation of the control is verified, reconnect the load. IMPORTANT: Follow these troubleshooting procedures in the order presented. Do not skip any of the steps in the procedures. 1. Check for proper voltage to the control. A. Remove the cover by loosening the four cover screws. B. Use an AC voltmeter to check the voltage between the common and 120V or 240V terminals. C. The voltage must be between 102 and 132 volts for 120V applications; 177 and 264 volts for 208/230V applications. D. If the voltage reading is not within the required range, check the power source and input power wires for problems.

8016563 Sheet 2 of 4 Rev. 03/14/06

Universal Thermostat Kit Installation Instructions FOR USE WITH DISPENSERS ONLY THIS CONTROL KIT IS INTENDED TO REDUCE OVERFILL AND CONDENSATION ISSUES 1. Remove all ice from dispenser. 2. Disconnect all power to the ice machine and dispenser at the service disconnect or fuse/breaker panel. 3. Move the ice machine and dispenser away from the wall for easier access. 4. Remove all panels and control box cover. 5. If an ice machine is already installed on the dispenser, raise and support the right side of the ice machine. Install the mounting bracket on the right-hand side of the dispenser 6 from the right rear corner. Compress the bracket to the thickness of the dispenser wall and tighten the two screws. 6. Route thermistor wire out back of the ice machine/dispenser (lower the ice machine, if supported). Remove unused knockout on the ice machine back panel, install romex connector and route wire into the ice machine compressor compartment. 7. Normally the controller can be mounted on the bulkhead flange. If not, a suitable area must be found for your model. Use controller bracket to locate mounting holes on the flange of the bulkhead. Drill two 9/32" diameter holes (used to mount the controller bracket - see View A). Do not mount the controller, at this time. 8. Route the four wires from the temperature control to the control box (insuring that the wires will not come in contact with any refrigeration tubing). IMPORTANT: The thermostat must be wired to match the voltage of the ice machine. The thermostat is pre-wired for 115 volts. Rewire thermostat, if your ice machine is 240 volts. 9. The control box line voltage wiring offers two options: Connect thermostat L1 (brown) and L2 (blue) wires to contactor (incoming line voltage side) L1 and L2. OR Disconnect incoming power line wire nuts. Remove quick-connect fittings from brown and blue wires and strip 1/2 of insulation from the wires. Connect incoming power L1, ice machine L1, and thermostat L1 (brown) wires together with wire nut. Connect incoming power L2, ice machine L2, and thermostat L2 (blue) wires together with wire nut. 10. Disconnect the red male/female connector bin switch wire and connect the red male wire from the controller to the red female bin switch wire. 11. Connect the white male bin switch wire to the white female wire of the controller. 12. Restore all power to the ice machine and the dispenser at the service-disconnect or fuse/breaker panel. 13. The factory setting on the thermostat will be correct for most applications. Adjust only when necessary. 14. With two screws, secure the controller bracket assembly to the flange of the bulkhead. 15. Reinstall the control box cover and all panels. Position the controller in a suitable location. It can be installed here on most ice machines. Use bracket to locate mounting holes - drill two 9/32" holes through bulkhead flange to secure controller Route sensor wire between dispenser and ice machine View A Install romex connector in a vacant knockout and route sensor wire into compressor compartment

8016563 Sheet 3 of 4 Rev. 03/14/06

Keypad Locked Out Jumper Position Red Lead Sensor Probe Route Sensor Wiring Here Black Lead Sensor Probe Blue Lead Power Brown Lead Power Red 22AWG Lead Bin Switch or Toggle Switch White 22AWG Lead Bin Switch or Toggle Switch FACTORY PRESET TEMPERATURE CONTROL CODE SETTINGS AS FOLLOWS: Set Point - SP: 40 Differential - DIF: 1 Anti Short Cycle Delay - ASD: 1 Temperature Offset - OFS: 0 Sensor Failure Operation - SF: 1 - Cube 0 - Flake/Nugget/Chiplet View C

8016563 Sheet 4 of 4 Rev. 03/14/06