DETCON MODEL SERIES 700 GAS DETECTORS

Similar documents
Model Series 700. detcon. Environmentally Bulletproof Gas Detection Sensors. Multi-Layer Surge Protection Water-Proof Corrosion-Proof

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection

Industrial Grade Gas Detection

Fixed Gas Detectors Portable Gas Detectors Flame Detectors SmartWireless Control Solutions Gas Analyzers GF-00002A-EN

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Sieger Apex. Flexibility that meets your requirements

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

SIL 2. Ultima X Series Gas Monitors CERTIFIED

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

3M Oldham OLCT 100. Description. Fixed Gas Detector

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

OLC(T) 100 FIXED GAS DETECTOR

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Better detection. Better protection. Fixed Gas & Flame Detection Product Overview - North America Region

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Model D12. Digital Gas Transmitter

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Model D12-IR. Digital Gas Transmitter...

Dräger Polytron 8700 IR Detection of flammable gases and vapors

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

The Art of Gas Detection

S5000 Gas Monitor. GMS5000.com

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Fixed Gas & Flame Detection International Product Range Overview

GAS DETECTOR ST400EC PART.NO

Warranty Registration

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Model 1000 H 2 S E-Chem/ CO 2 Process Analyzer

ULTIMA X5000. MSAX5000.com

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Transmitters/Sensors. OLCT Series

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

ALTAIR 5X Multigas Detector

GAS DETECTORS. When every second counts

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

MSA Fixed Gas & Flame Detection for the Automotive Industry

Toxic Gas Detection. Model F12. Toxic Gas Detection

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

for Today s Industrial Environment

Operation and Maintenance Manual

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Dräger Flame 2100 Flame Detection

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

ESD3000 ESD200 Combustible / Toxic Gas Detector

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

incontrol Systems Inc. Flame and Gas Detection

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Frequently Asked Questions

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

INSTRUCTION MANUAL Detcon Model IR-700

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

INSTRUCTION MANUAL Detcon Model DM-700

MERIDIAN UNIVERSAL GAS DETECTOR

Dräger Flame 2500 Flame Detection

MSA Gas Detection. for the Water and Wastewater Industries. Does your facility meet NFPA 820?

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

Dräger Polytron 5700 IR Detection of flammable gases and vapours

FIXED POINT SINGLE OR DUAL GAS MONITOR WITH DUAL ANALOG OUTPUTS

SenSmart Universal Gas Detector Series

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Two-Channel Gas Controller

Contents. Fixed Gas Detectors. Flame Detectors. Portable Gas Detectors. DF-TV7 Series CTX PS PS200 ABC Docking Station

Dependable Solutions for Gas Detection

IGD.CO.UK

ESD500. ESD500 Combustible / Toxic Gas Detector

GAS PLUS ALARM SYSTEM

FM Approved Fire & Gas Detection System

M2A Transmitter Operator s Manual

GAS DETECTION International Gas Detectors CH4 NO

SEC 5000 IREvolution Gas Detector

Lamp Supply (Recommended)

SEC Signature Process Gas Analyzer

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

GENERAL MONITORS. Protection for life. Product Guide. Total Solution Provider for Gas and Flame Detection

Transcription:

DETCON MODEL SERIES 700 GAS DETECTORS

DETCON MODEL SERIES 700 GAS DETECTORS Model Series 700 Gas Detectors Description Detcon Model Series 700 industrial gas detection sensors are a new generation of intelligent sensor modules that incorporate and integrate several leading edge im prove ments. The sensors are specifically designed for harsh and extreme locations. This new and superior level of environmental durability in sensor design includes an electropolished 316 stainless steel housing, multi-layered transient spike protection circuitry and 100% en cap sulated electronics. The sensor electronics are completely protected and immune to water ingress and corrosion. The gas detector sensor elements are all plug-in components and can easily be replaced in the field. Operator interface is non-intrusive via a small hand held magnet. Configuration and routine calibration is intuitive and menu driven with fully scripted instructions. Sensor status is displayed on a built-in alphanumeric LED display. Model Series 700 intelligent sensor modules feature dual redundant outputs, a linear 4-20 milliamp analog signal and a Modbus RS-485 serial output. It is becoming increasingly important that safety systems meet the Safety Integrity Level (SIL) requirements of IEC 61508 and IEC 61511. The SIL rating can only be determined by considering the complete safety system. The Detcon 700 series sensor modules are designed with this in mind and feature a new and unmatched level of pre-emptive fault diagnostics. Application variables like input voltage range, operating temperature range, maintenance schedule, detector reliability and output integrity are all monitored and reported via the 4-20 ma and RS-485 serial output. As a component of a SIL rated system, the Safe Failure Fraction (SFF) of Detcon Model Series 700 sensors are designed to meet the requirements for any SIL 2 rated system. Model Series 700 sensors utilize six distinctive gas detection technologies to satisfy a wide range of industrial applications that require monitoring of oxygen, toxic and flammable gases. Sensors for Hydrogen Sulfide CHEMFET MOS Solid State Technology Harsh and Extreme Locations Wide Temperature & Humidity Range 10-year Sensor Warranty Electrochemical Technology Quick Response Time Long Term Calibration Stability Low Power Consumption Sensors for Combustible Gas Catalytic Technology Non-selective Combustible Gas Detector 3 to 5 Year Life Expectancy Rugged Construction Infrared Technology Combustible Hydrocarbon Gas Detector 5-Year Warranty Miniature Plug-in Optical Detector Sensors for Toxic Gases Electrochemical Technology Quick Response Time Long Term Calibration Stability Low Power Consumption Photo Ionization Universal Non-Selective VOC Sensor Miniature Plug-in Detector Oxygen Sensors CO2 Sensors Electrochemical Technology Quick Response Time Embedded Temperature Compensation 2-year Sensor Warranty Infrared Technology CO2 Gas Detector 5-Year Warranty Miniature Plug-in Optical Detector

ANATOMY OF A MODEL SERIES 700 Junction Box Surge Protection Termination RS-485 Modbus serial output Power 11.5-28 VDC 4-20 ma output 3/4 NPT Thread Fully Encapsulated Circuitry Eliminates failures due to water ingress, corrosion, and vibration Microprocessor Controlled Circuitry With advanced level of I/O protection Corrosion Resistant Electropolished 316SS sensor housing Viewing Lens and Display Scrolling alpha-numeric LED display. Displays reading, status, and supports user interface Internal Magnetic Programming Non-intrusive and simplified operator interface via handheld magnet. Plug-in Replaceable Gas Sensors Catalytic Bead, IR, Solid State H2S, Electrochemical, O2, PID Corrosion-Resistant Lower Housing Electropolished 316 SS threaded housing for quick release. Harsh Environment Splashguard Integral Calibration Port

Technology Features Environmentally Bulletproof Electropolished 316SS Construction 100% Encapsulated Circuitry Bullet-Proof I/O Protection Over-voltage Miswiring EMI/RFI Immunity Water-Proof, Corrosion-Proof, Vibration-Proof Modular and Serviceable Gold Plated Mating Pins Modular Design Plug and Play Components Minimal Spare Parts Universal Design Concept Quick Thread Release For Sensor Replacement Integral Calibration Port Failsafe User-Friendly Interface LED Display With Antiglare Cover Full Text Display Method Non-intrusive Interface

Installation & Integration Options Model Series 700 gas detectors provide the end-user with a wide variety of output & integration options. The standard intelligent sensor module features an industry standard 4-20 ma output and a RS-485 MODBUS RTU interface. These outputs can be used simultaneously. Additional integration options include a Remote Sensor/Alarm Relay, Wireless Interface and communication interface modules for HART, Foundation Fieldbus and Profibus. Shown below are some typical system integration approaches: 4-20 ma, Remote Sensor Separation & Local Relays Model 612-N1 4-20 ma Detcon Alarm Station Remote Sensor Separation Relays Local Relays Serial Input Model X40 RS-485 Detcon Alarm Station Relays High Density System - 4-20 ma or Serial Model MCX-32 Distributed I/O Controller RS-232, RS-485, Ethernet 4-20 ma Detcon Alarm Station RS-485 HMI Relays Wide Range DCS/DAS and Integration Options Remote Control Alarm Relay Hart RAM Hart Bridge Foundation Fieldbus Wireless Interface

Combustible Gas Sensor (matched pair catalytic bead) FP-700 Combustible Gas 0-100 % LEL -40 C to +75 C 2 Years Hydrogen Sulfide Gas Sensor (solid state metal oxide semiconductor) TP-700 Hydrogen Sulfide/H2S 0-100 ppm -40 C to +75 C 10 Year conditional Oxygen Gas Sensor (galvanic metal air battery) DM-700-O2 Oxygen/O2 0-25 % -20 C to +50 C 2 Years Combustible Hydrocarbon & Carbon Dioxide Gas Sensors (non-dispersive infrared optical - NDIR) IR-700-CH Combustible Hydrocarbons 0-100 % LEL-40 C to +75 C 5 Years pro-rated IR-700-CO2 Carbon Dioxide/CO2 0-3 % -40 C to +75 C 5 Years pro-rated Volatile Organic Compound (VOC) Gas Sensors (photo ionization detector - PID) PI-700-VOC Volatile Organic Compounds 0-10 ppm -20 C to +50 C 6 Months PI-701-VOC Volatile Organic Compounds 0-1,000 ppm -20 C to +50 C 6 Months Toxic Gas Sensors (electrochemical fuel cell) DM-700-C2H2 Acetylene/C2H2 0-100 ppm 20 C to +50 C 2 Years DM-700-NH3 Ammonia/NH3 0-100 ppm 20 C to +40 C 2 Years DM-700-AsH3 Arsine/AsH3 0-1 ppm 20 C to +40 C 1 1/2 Years DM-700-Br2 Bromine/Br2 0-5 ppm 20 C to +50 C 2 Years DM-700-C4H6 Butadiene/C4H6 0-100 ppm 20 C to +50 C 2 Years DM-700-CO Carbon Monoxide/CO 0-100 ppm 40 C to +50 C 3 Years DM-700-Cl2 Chlorine/Cl2 0-10 ppm 20 C to +50 C 2 Years DM-701-ClO2 Chlorine Dioxide/ClO2 0-1 ppm 20 C to +50 C 2 Years DM-700-B2H6 Diborane/B2H6 0-5 ppm 20 C to +40 C 1 1/2 Years DM-700-C2H5OH Ethanol/C2H5OH 0-100 ppm 20 C to +50 C 2 Years DM-700-C2H5SH Ethyl Mercaptan/C2H5SH 0-100 ppm 40 C to +50 C 2 Years DM-700-C2H4 Ethylene/C2H4 0-100 ppm 20 C to +50 C 2 Years DM-700-C2H4O Ethylene Oxide/C2H4O 0-100 ppm 20 C to +50 C 2 Years DM-700-F2 Fluorine/F2 0-1 ppm 10 C to +40 C 1 1/2 Years DM-700-CH2O Formaldehyde/CH2O 0-100 ppm 20 C to +50 C 2 Years DM-700-GeH4 Germane/GeH4 0-2 ppm 20 C to +40 C 1 1/2 Years DM-700-N2H4 Hydrazine/N2H4 0-1 ppm 10 C to +40 C 1 Year DM-700-H2 Hydrogen/H2 0-100 ppm 20 C to +50 C 2 Years DM-701-H2 Hydrogen/H2 LEL 40 C to +40 C 2 Years DM-702-H2 Hydrogen/H2 0-1% 40 C to +40 C 2 Years DM-700-HBr Hydrogen Bromide/HBr 0-30 ppm 20 C to +40 C 1 1/2 Years DM-700-HCl Hydrogen Chloride/HCl 0-30 ppm 20 C to +40 C 1 1/2 Years DM-700-HCN Hydrogen Cyanide/HCN 0-30 ppm 40 C to +40 C 2 Years DM-700-HF Hydrogen Fluoride/HF 0-10 ppm 20 C to +35 C 1 Years DM-700-H2S Hydrogen Sulfide/H2S 0-100 ppm 40 C to +50 C 2 Years DM-700-CH3OH Methanol/CH3OH 0-100 ppm 20 C to +50 C 2 Years DM-700-CH3SH Methyl Mercaptan/CH3SH 0-100 ppm 40 C to +50 C 2 Years DM-700-NO Nitric Oxide/NO 0-100 ppm 20 C to +50 C 3 Years DM-700-NO2 Nitrogen Dioxide/NO2 0-10 ppm 20 C to +50 C 2 Years DM-700-O3 Ozone/O3 0-1 ppm 10 C to +40 C 2 Years DM-700-PH3 Phosphine/PH3 0-5 ppm 20 C to +40 C 1 1/2 Years DM-700-SiH4 Silane/SiH4 0-50 ppm 20 C to +40 C 1 1/2 Years DM-700-SO2 Sulfur Dioxide/SO2 0-20 ppm 20 C to +50 C 2 Years *Standard Range - contact factory for other ranges. **Replaceable plug-in sensor. Contact the factory for other gases not on this list. Cross sensitivity data available on request.

Ordering Information Accessories -Description Remote Control/Alarm Relay in NEMA 7 Junction Box (Aluminum or Stainless Steel) Hart RAM in NEMA 7 Junction Box (Aluminum or Stainless Steel) Hart Bridge in NEMA 7 Junction Box (Aluminum or Stainless Steel) Foundation Fieldbus in NEMA 7 Junction Box (Aluminum or Stainless Steel) Wireless Interface in NEMA 7 Junction Box (Aluminum or Stainless Steel) Specifications Common Specifications Input Voltage 11.5-28 VDC standard Power Consumption <2 watts typical Outputs Linear 4-20 ma DC RS-485 Modbus -RTU Electrical Classification Explosion Proof FP-700, TP-700, IR-700-CH, IR-700-CO2: Class I, Division 1, Groups B, C, D Class I, Zone 1, Group IIB+H2 (ATEX) DM-700 Toxics, DM-700-O2, PI-700: Class I, Division 1, Groups A, B, C, D Class I, Zone 1, Group IIC (ATEX) Safety Approvals CSA/NRTL (US OSHA Certified) ATEX GOST INMETRO CNEX PESO ABS Dimensions 7 High x 2 1/8 Diameter (sensor only) Weight 2 Lbs Functional Safety Rating IEC 61508 SIL2 Certified (IR, TP, FP, DM) Exida assessed SIL2 (FMEDA) Performance Approvals IR-700, FP-700 to ISA 12.13, CSA #152 TP-700, DM-700 to ISA 92.0.01 Technology Specifications Accuracy/Repeatability FP-700: ±3% 0-50% LEL; ±5% 50-100% TP-700: ±10% of reading or ±2 ppm (greater of) DM-700-O2: ±2% full scale IR-700-CH: ±3% 0-50% LEL; ±5% 50-100% LEL IR-700-CO2: ±5% full scale PI-700: ±10% of reading; ±2.5% of range (greater of) DM-700 (toxics): ±2% full scale Response/Clearing Time FP-700: T50 <10 seconds; T90 <30 seconds TP-700: T50 <30 seconds; T80 <60 seconds DM-700-O2: T90 <20 seconds IR-700-CH: T50 <10 seconds; T90 <30 seconds IR-700-CO2: T50 <15 seconds; T90 <40 seconds PI-700: T50 <10 seconds; T90 <30 seconds DM-700 (toxics): Contact factory for specific gases Operating Humidity Range (Continuous) FP-700: 0-99% RH non-condensing TP-700: 15-100% RH non-condensing DM-700-O2: 0-99% RH non-condensing IR-700-CH: 0-99% RH non-condensing IR-700-CO2: 0-99% RH non-condensing PI-700: 0-100% non-condensing DM-700 (toxics): typically 10-90% RH contact factory for specific gases Warranty Detcon Inc. warrants each new Model 700 Intelligent Transmitter to be free from de fects in ma te ri al and work man ship un der in tend ed nor mal use for a pe ri od of two years from the date of ship ment to the original pur chas er. Detcon warrants each new plug-in replaceable sensor to be free from defects in material and workmanship under intended normal use for the period described in the table on the left. All war ran ties are FOB the De t con fac to ry lo cat ed in The Wood lands, Tex as, USA.

www.tycogfd.com l Copyright 2015 Tyco Gas and Flame. l All rights reserved. l GF-00004A