NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit

Similar documents
ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

Hubbell Harsh & Hazardous. Our Brands. Corporate Information

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

TYPE APPROVAL CERTIFICATE

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

High bay LED lighting fixture

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

INSTRUCTION & SERVICE MANUAL

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection


INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

IECEx Certificate of Conformity

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

distributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax:

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

PRODUCT DATA SHEET ilh8

INSTRUCTION MANUAL (ATEX / IECEx)

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Ex LED light fittings

Basic Ex products / Zone 1, 21

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Explosion-proof Immersion Heater Type D-8660

XLFE-4/1. Borosilicate glass globe

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

INSTRUCTION MANUAL (ATEX / IECEx)

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

Integrated Solutions Low Voltage Systems

INTRINSICALLY SAFE LIGHTING RANGE

Vehicle Safety & Warning. Product Catalogue (0)

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Electrical Installations Design, Selection, Erection and Inspection

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Flameproof Manual Call Points Series MCP

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Illumination unit For sight glass level indicator Model LGI

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Manual Power relay SR853

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

High Quality LED Lighting!

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

Certification Supplement Manual

OPTIBAR P 1010/2010 C Supplementary instructions

Technology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design

DB4 Range - SPEAKERS - Up to 25 Watts

Operating Instructions

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

Survey of electrical equipment installed in hazardous areas on tankers

14300 MAINS SEPARATOR ALARM MANUAL

EX-SIGNAL- AND ESCAPE SIGN LUMINAIRS

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

Wolf Safety Lamp Company HAZARDOUSAREA PORTABLE & TEMPORARY LIGHTING POWER DISTRIBUTION

North American Cable Glands

WELCOME TO HAWKE INTERNATIONAL INTERACTIVE CATALOGUE

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Explosion Proof Manual Call Points Series MCP

Gas cylinder scale Model GCS-1

D O M E S T I C LED. Lighting C O M M E R C I A L

NGC-20-C-E and NGC-20-CL-E

DTS Light fittings for explosive atmospheres

OPTIBAR DP 7060 Supplementary Instructions

UL HAZARDOUS LOCATIONS SERVICES

Safety instructions VEGAPULS 64

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA

CF1 ProVector Explosion-Proof Heaters

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

Loadstar AC/DC Systems

NGC-20-C-E and NGC-20-CL-E

Lighting for Hazardous & Severe Environments

Annubar Flowmeter Series

E2S Datasheet v10a

Indoor/outdoor resistance thermometer Model TR60

LED EMERGENCY LIGHTING

Industrial & Hazardous Area Electrical Equipment

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

Operating Manual Distribution box

Dual certification! Air handling units for potentially explosive atmospheres

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Transcription:

NexLED Ex e LED BULKHEAD 62 NexLED with Exit Sign kit The NexLED bulkhead utilises the latest LED technology to provide instant illumination. The NexLED requires no re-lamping making it virtually maintenance free and unaffected by low temperatures. This combination makes the NexLED ideal for extreme environmental applications. Coloured LED options are also available. NexLED with green LED s Standard Specification Features Type of Protection ATEX Classification Area Classification Certificate Coding Enclosure Reflector Entry Termination Installation Light Source Control Gear Burning Position Ingress Protection Electrical Supply Ex e mb (Increased Safety and Encapsulation) Group II Category 2 GD Zone 1 and Zone 21 area to EN 60079-10-1 and EN 60079-10-2 with installation to EN 60079-14 EC Type Examination Certificate Baseefa04ATEX0245 IEC Ex BAS09.0062 II 2 GD Ex e mb IIC Refer to table for T rating and Ambient Aluminium alloy LM6 to BS 1490 (AC44100) with toughened glass and silicone gasket Brushed aluminium 2 x M20 cable entries 3 core 4mm² max conductor with looping Surface mounted, 4 mounting holes located outside of seal 1W light emitting diodes. Colour: white Electronic Universal IP66/67 to EN 60529 110-254V AC (50/60Hz)/DC Installation to gas groups IIA, IIB and IIC Highly visible, instant light Easy to install and maintain Ultra long life, no relamping required Very low power consumption International Approvals ATEX and GOST IECEx Compliant

ATEX CATEGORY 2 ZONE 1 & 21 APPLICATIONS 63 Std. Cat No. Wattage Light Source TClass T C (Dust) Ambient C Weight NELE/201/LE 2W Light Emitting Diode T4 100-45 to +55 4.0kg NELE/801/LE 8W Light Emitting Diode T4 100-45 to +55 4.1kg Options - Suffix to Catalogue No. /RDE Red LED s /ADE Amber LED s /GDE Green LED s /IEC Supplied with IECEx certification label /BDE Blue LED s Accessories Should be ordered separately Catalogue Order Code Exit sign kit (supplied with - up, down, left and right labels*) * Other signage options available upon request, please contact technical sales (techsupport@chalmit.com) SNEL1-0008 Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications.

NexLED E Ex e ib mb EMERGENCY 64 NexLED with Exit Sign kit The NexLED emergency provides emergency battery backup to ensure continued operation in the event of a power outage. The emergency version benefits from the same features as the standard NexLED and is available as a special low temperature version for operation down to -45 C. Coloured LED options are also available. NexLED with green LED s Standard Specification Features Type of Protection ATEX Classification Area Classification Certificate Coding Enclosure Reflector Entry Termination Installation Light Source Control Gear Burning Position Ingress Protection Battery Emergency Duration Electrical Supply Ex e ib mb (Increased Safety, Intrisically Safe Encapsulated) Dust protected enclosure Group II Category 2 GD Zone 1 and Zone 21 areas to EN 60079-10-1 and EN 60079-10-2 with installation to EN 60079-14 EC Type Examination Certificate Baseefa04ATEX0245 IEC Ex BAS09.0062 II 2 GD Ex e ib mb IIC T4 Aluminium alloy LM6 to BS 1490 (AC44100) with toughened glass and silicone gasket Brushed aluminium 2 x M20 cable entries 4 core 4mm² max conductor with looping Surface mounted, 4 mounting holes located outside of seal 1W light emitting diodes. Colour: white Electronic Universal IP66/67 to EN 60529 Ni-Cd (6V) 8W version - 90 minutes 2W version - 3 hours 110-254V AC/DC Installation to gas groups IIA, IIB and IIC Highly visible, instant light Easy to install and maintain Ultra long life, no relamping required Very low power consumption 100% output in emergency mode (Up to 3 hours) Rechargable Ni-Cd batteries with charging indication Compatible with UPS systems International Approvals ATEX and GOST IECEx Compliant

ATEX CATEGORY 2 ZONE 1 & 21 APPLICATIONS 65 Std. Cat No. Wattage Light Source TClass T C (Dust) Ambient C Weight NELE/201/LE/EM 2W Light Emitting Diode T4 100-20 to +55 4.0kg NELE/801/LE/EM 8W Light Emitting Diode T4 100-20 to +55 4.1kg Options - Suffix to Catalogue No. /RDE Red LED s /ADE Amber LED s /GDE Green LED s /LT Low temperature -45 C to +55 C /BDE Blue LED s /IEC Supplied with IECEx certification label Accessories Should be ordered separately Catalogue Order Code Exit sign kit (supplied with - up, down, left and right labels*) * Other signage options available upon request, please contact technical sales (techsupport@chalmit.com) SNEL1-0008 Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications.

NexLED LED Bulkhead 116 NexLED with Exit Sign kit The NexLED bulkhead utilises the latest LED technology to provide instant illumination. The NexLED requires no re-lamping making it virtually maintenance free and unaffected by low temperatures. This combination makes the NexLED ideal for extreme environmental applications. Coloured LED options are also available. NexLED with green LED s Standard Specification Features Enclosure Reflector Entry Termination Installation Lamp Type Cast aluminium with toughened glass and silicone gasket Brushed aluminium 3 x M20 cable entries 4 core 4mm² max conductor with looping Surface mounted, 4 mounting holes located outside of seal 2 x 1W light emitting diodes or 8 x 1W light emitting diodes. Colour: white Highly visible, instant light Easy to install and maintain Ultra long life, no relamping required Very low power consumption 100% output in emergency mode (Up to 3 hours) Rechargable Ni-mH batteries with charging indication Compatible with UPS systems Control Gear Electronic Burning Position Universal Ingress Protection IP66/67 to EN 60529 Emergency Duration 3 hours (emergency models) Electrical Supply 220-240V ac/dc

INDUSTRIAL and MARINE APPLICATIONS 117 Std. Cat No. Wattage Lamp Type Ambient C Weight NELI/201/LE 2W Light Emitting Diode -20 to 45 3.5kg NELI/801/LE 8W Light Emitting Diode -20 to 45 3.5kg NELI/201/LE/EM 2W Light Emitting Diode -20 to 45 3.5kg NELI/801/LE/EM 8W Light Emitting Diode -20 to 45 3.5kg Options - Suffix to Catalogue No. /RDE Red LED s /ADE Amber LED s /GDE Green LED s /LT Low temperature -45 C to +45 C /BDE Blue LED s Accessories Should be ordered separately Green exit sign kit (4 labels - up, down, left and right) Catalogue Order Code SNEL1-0008 Product design and specifications are subject to change without notice, please check the Chalmit website for latest specifications.