Wireless Occupancy Sensor:

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

9000P Wireless Alarm Owner s Manual

PRODUCT DIAGRAM PACKAGE CONTENTS

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

180 Degree Ceiling Mounted Occupancy Sensors

Installation Instructions

HSD-200Z Z-Wave Motion Sensor

Pet Immune SAW PIR Motion Sensor

Wireless Home Appliance Timer Remote Control Kit

Home Doorway Alert Kit

E529 Smart Digital Thermostat Product Guide

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

Installer Guide smart connect

Zigbee Smoke Sensor PSG03

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

Wireless Driveway and Intruder Alert

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

PRODUCT DIAGRAM PACKAGE CONTENTS

powered by Note: This manual applies to several packages. As such, some parts and some steps may not pertain to the package that you purchased.

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

SZ-PIR04N ZigBee Motion Detector Installation Guide

SET TEMPERATURE( F) AUTO COOL DRY HEAT TEMP MODE SWING RESET LOCK LED DISPLAY

REMOTE CONTROL MANUAL

EW 40 Wireless Fan Control

Honeywell Temperature & Humidity Sensor with LCD

Remote Control User Manual

Model: WS-9133U-IT Quick Setup Guide DC: WIRELESS FORECAST STATION

IN-OUT Thermometer with Cable Free Sensor and Clock

INSTRUCTIONS OPERATING BLUETOOTH CAPACITIVE TOUCH THERMOSTAT MODEL COOL/FURNACE COOL/FURNACE/HEAT PUMP

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

Supervised Security System Owner's Guide

Installer Guide smart connect

Campers Alert TM Portable System Hunters Alert TM Portable System

PTAC WIRELESS KITS (DT01*, DS01*, DD01*) INSTALLATION INSTRUCTIONS

Atomic Digital Wall Clock

CR166-RG57A6EU- 6 INFRARED WIRELESS MULTI FUNCTION REMOTE CONTROLLER OWNER S MANUAL

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

WatchDog Wireless Crop Monitor Operation Manual

Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING

Integrated Sensor Suite with Fan-Aspirated Radiation Shield

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

40 Built-in Electric Fireplace Operating and Installation Instructions

WIRELESS MULTI-ZONE DIGITAL THERMOMETER WITH RADIO CONTROLLED CLOCK. Model No (SF Version) Instruction Manual

Thermometer model 02059

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

CR193-RG70E2(2)BGEU

,,,,,, ,,,, Remote controller Specifications Operation buttons Indicators on LCD How to use the buttons Auto operation...

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

WIRELESS COLOR WEATHER STATION

ATOMIC DIGITAL CLOCK. Time and Alarm

Digital Refrigerator/Freezer Thermometer model 00986

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

Ambient Weather RC-8487 ClearView Radio Controlled Travel Alarm Clock with Indoor Temperature User Manual

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

WIRELESS COLOR WEATHER STATION

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing.

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

FEATURES AND SPECIFICATIONS

Model: WS-8147U-IT Instruction Manual DC: ATOMIC DIGITAL CLOCK WITH MOON PHASE

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

INSTALLATION GUIDE XTLN-WIFI PANEL

Driveway Alarm INSTALLATION MANUAL.

Digital Cooking Thermometer models / 00282

DCH-Z110/Z120. Function Compare DCH-Z110/DCH-Z120. Add to/remove from Z-Wave TM Network

IMPORTANT. Questions? Contact Customer Support at (877) or visit 5-in-1 PRO+ Weather Sensor model

Slim Multisensor PST02-A/B/C

Weather Light Model: BAR210 / BAR210U / BAR210A USER MANUAL. EU-Declaration of Conformity...7 FCC Statement...7 Declaration of Conformity...

DIGITAL ATOMIC WALL CLOCK

Scan the below QR code to download Smart Flame

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

Portable Air Conditioner User Manual

MODEL MR-720 FUNCTIONS AND CONTROLS SELF-POWERED AM/FM WEATHER BAND CLOCK RADIO

Light Level Detector, Surface Mount 5754PE. Installation Instructions

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

WIRELESS COLOR FORECAST STATION

Little Anne. Important Product Information

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

Atomic Projection Alarm Clock

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

SF812 SMOKE DETECTOR. Include to or Exclude from a Z-Wave TM Network. Product Overview

Projection Alarm Clock

Transcription:

21233 Wireless Occupancy Sensor, Ceiling Mount Installation Instructions The Daintree Networks ceiling mounted Wireless Occupancy Sensor operates seamlessly within the ControlScope Manager (CSM), the Daintree management app. The WOS2-CM is a battery-powered occupancy sensor using passive infrared (PIR) sensing technology to detect movement. As part of the ControlScope system and using open, standards based ZigBee wireless communications, the WOS2-CM reports real-time occupancy events to turn on lights or keep them on when movement is detected, and turn off lights when a space is left vacant. The sensor s off-delay timer is user-configurable from any location using the CSM web application, eliminating the need for on-site, manual sensor adjustment. The WOS2-CM-S provides the standard coverage area, 5SF with a 36 degree (lateral) coverage. The WOS2-CM-E provides an extended coverage area of up to 1SF. Occupancy Sensor Lens Installation Process Network LED (green) & Test Mode LED (red) Keep the sensor lens clean. Avoid touching the sensor lens. After first-time installation or reinstallation of a new battery, allow up to three minutes for initalization. 1. Determine the mounting location for the sensor based on the desired occupancy coverage. See Placement for details. 2. Remove the sensor from the base by twisting it. Locate the sensor s IEEE address on the label inside the base. Record the IEEE address in the sensor s location on the facility floor plan. 3. Attach the mounting base to the ceiling. Be sure the label is visible after mounting the base. 4. Install the batteries in the orientation (+ - ) shown on the bottom of the battery compartments. 5.Secure the sensor to the ceiling by twisting it onto the base. 6. After the batteries have been installed for at least 3 minutes, initiate the Installation Test Mode: Momentarily press the Utility button. The green LED flashes once then the red LED flashes each time the sensor detects motion. (The test mode times out after 5 minutes.) A. Walk test the sensor. Walk outside the coverage area and wait for the red LED to stop flashing. Step inside the desired coverage area and observe the red LED. B. Repeat from various positions in the C. If necessary, adjust the sensor as described in Adjustments: PIR Sensitivity. Repeat the walk test. D. If you do not observe the proper behavior, see Troubleshooting. Base Mountain View, CA, www.daintree.net Wireless Occupancy Sensor, Model: WOS2-CM Power Supply: Battery ER1455 AA 3.6V (2) FCC ID: NRH-ZB-Z1B IC: 8984A-Z1B ICES/NMB-3 CLASS B FOR INDOOR USE ONLY IEEE Address: 137A- 1 DT18 (Rev. 2.5.18)

Installation Process continued 7.Exit Installation Test Mode. Momentarily press the Utility button again, or wait 5 minutes for the mode to time out. 8.Complete the installation by resetting the device: press and hold the Utility button for 5 seconds. Release the button when the Network LED begins to flash rapidly. The sensor attempts to join a ZigBee network for up to 3 seconds. See LED Operation and Joining the ZigBee Network. LED Operation Green LED: Network Indicator Rapid flash (12 times per second) for up to 3 seconds Solid for 1 seconds Flashes once While unit is in Installation Test Mode, turns On Flashes twice On for 2 seconds every 3 seconds Description Device is trying to join ZigBee network. If it fails to join, it will retry after 15 minutes.* Device successfully joined a ZigBee network. Utility button was pressed to initiate Installation Test Mode. Daylight level is greater than the hold-off level set with trimpot. Utility button was pressed for 2 seconds and the device is currently joined to a network. The batteries are low; replace the batteries. * A network join can be retriggered manually at any time using one of the following methods: Reset to factory defaults: This causes the device to leave any network to which it is currently joined. Following the reset, the device attempts to join a network. Press and hold the Utility button for 5 seconds. Release the button when the Network LED begins to flash rapidly. Activate device: Press and hold the Utility button for 2 seconds. If the device is already joined to a network, the Network LED flashes twice. If the device is not joined to a network, the Network LED flashes rapidly and the device will attempt to join a network. For more information about configuring the lighting control network, see the instructions and on-line help provided with the CSM application. Joining the Zigbee Network After successfully completing the Installation Test the occupancy sensor is ready to communicate with the Daintree Wireless Area Controller (WAC) and the Daintree CSM web-based lighting management user interface. For more information about configuring the lighting control network, see the instructions and on-line help provided with the CSM application. Red LED: Installation Test Mode, Motion While unit is in Installation Test Mode, Flashes Off Description The red LED flashes each time sensor detects occupancy. Test mode times out after 5 minutes. Normal operation: either not detecting occupancy, or detected occupancy and in OffffDelay. LED turns on with initial occupancy. Placement The PIR sensor can only be installed indoors. It is extremely important to select the appropriate installation location to avoid false occupancy reporting while obtaining the best sensitivity. A proper installation should meet the following conditions: 2

Placement continued The PIR sensor is typically mounted to 1 (2m to 3m) from the floor. The height affects the The PIR sensor must be 4 to 6 away from hot or cold sources such as heat or air conditioner vents, refrigerators, stoves, etc. The PIR sensor should not be installed in places with strong airflows. The PIR sensor must have clear line of sight to the It may not detect a human body if it is blocked by furniture, fixtures, large plants, glass, curtains, etc. Install the detector securely to the ceiling to minimize sensor vibration. The PIR sensor should not be installed on moveable objects, nor exposed to direct sunlight. The resulting hot air and/or motion can cause false activation. Coverage Pattern, WOS2-CM-S, Standard Coverage Installation Height 1 from fl oor Detection Angle 1 Detection Radius up to 13 (3.9m) Coverage Pattern, WOS2-CM-E, Extended Coverage Installation Height 1 from fl oor Detection Angle 12 Detection Radius up to 17 (5.2m) 1 1 1 Top View Sensor mounted at 1 height from floor Side View Sensor mounted at 1 height from floor 26.2 (8m) 1 1 1 1 1 1 Top View Sensor mounted at 1 height from floor Top View Sensor mounted at 1 height from floor Side View Sensor mounted at 1 height from floor Side View Sensor mounted at 1 height from floor 39.2 (12m) 39.2 (12m) 3

Adjustments Two trimpots next to the battery compartment are used to adjust the Daylight Hold-Off threshold and PIR motion sensor sensitivity. Use caution when adjusting the trimpots. Do not use excess force, as this will damage the unit. Stop turning the trimpot when you feel resistance. Daylight Hold-Off PIR PIR Sensitivity Turn the trimpot clockwise to increase sensitivity. Turn the trimpot counter-clockwise to decrease sensitivity. Troubleshooting Minimum (counterclockwise) Maximum (clockwise) No LEDs turn on when I press the Utiity button. Check battery installation. Make sure batteries are oriented (+ -) correctly. The red Infrared Detection LED does not activate when walking through the coverage area while in Installation Test mode. Make sure that the lens is not obstructed and there is no debris on the lens. Check to see if the red LED turns on when you wave your hand directly in front of the lens. If the red LED turns on, adjust the PIR Sensitivity trimpot clockwise to increase sensitivity. Check for objects or barriers obstructing the sensor s view of the If the red LED does not turn on, the Installation Test mode may have timed out. Restart the Installation Test mode by momentarily pressing the Utility button. The green LED turns on briefly, then the red LED flashes with each detection. Installation Test mode times out in 5 minutes. The red LED flashes when nobody is moving in the Adjust the PIR senstivity trimpot counter-clockwise to reduce sensitivity. Repeat the walk test. Check for sources of hot airflow in the Review the Placement guidelines and eliminate false trigger sources. If lights do not turn Off after the WOS2-CM has Joined the ZigBee network: Check the Off delay for the zone in the Daintree CSM. Check for other CSM scheduled events or manual overrides that may be keeping the lights On. 4

FCC warning message This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and radiates radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encourage to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna; Increase the separation between the equipment and receiver; Connect the equipment into an outlet on a circuit different from that to which the receiver is connected; Consult the dealer or an experienced radio/tv technician for help. Specifications Power Supply Battery Life Radio Properties Sensor Coverage (maximum) Off-Delay Timer Mounting Operating Environment Compliance Dimensions (2) Lithium-thionyl chloride batteries (Li-SOCl2) AA 3.6V (included) 5 years (normal operation) 2.4 GHz, +7dBm transmit power 36, 5 sq. ft (WOS2-CM-S) 36, 1 sq. ft (WOS2-CM-E) 3 seconds (fixed), additional delay time configurable in CSM Ceiling surface mount (2 screws) 14 F to +122 F (-1 C to 5 C) Indoor use only FCC Part 15B, FCC ID: NRH-ZB-Z1B ICES/ NMB-3 Class B, IC: 8984A-Z1B Diameter x Depth: 3.7 x 1.3 (95mm x 32mm) Weight (without ba ery): 2.85 oz. (81g) Industry Canada (IC) Warning Message Product complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Call 1 888 694 3533 products.currentbyge.com GE is a trademark of the General Electric Company. All other trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. Current and GE Lighting are businesses of the General Electric Company. 217 GE 5