Flameproof Manual Call Points Series MCP

Similar documents
Flameproof Manual Call Points Series MCP

Explosion Proof Manual Call Points Series MCP

Flameproof Manual Call Points

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Integrated Solutions Low Voltage Systems

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Explosion Proof Combination Signal db (A) / 5 Joule

Manual Alarm Call Points

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Indoor/outdoor resistance thermometer Model TR60

IECEx Certificate of Conformity

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

Explosion-proof Immersion Heater Type D-8660

Hazardous Area Signalling

Temperature Measurement Transmitters for field mounting

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

Fire Alarm or Emergency Call Points

Ex LED light fittings

Fan Heaters Type VLEx

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

DICTATOR Hold-Open Systems for Hazardous Areas

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

DB4 Range - SPEAKERS - Up to 25 Watts

ExPolar Heating System

SOLUZIONI PER ATMOSFERA ESPLOSIVA

Manual Power relay SR853

Hazardous Area Portable Fan Heater The Bulldog

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Certification Supplement Manual

Sinus Jevi (Explosion-Proof) Condens Heaters

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Dräger Polytron 5700 IR Detection of flammable gases and vapours

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES

INSTRUCTION MANUAL (ATEX / IECEx)

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Operating Instructions

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

WELCOME TO HAWKE INTERNATIONAL INTERACTIVE CATALOGUE

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

NGC-20-C-E and NGC-20-CL-E

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Switches compliant with ATEX directive

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Technical Manual for the Alarm Pull Station PH1

custom cabinets and junction boxes

IECEx Certificate of Conformity

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

DB1 Range - HORNS - Up to 103 db(a)

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

UL HAZARDOUS LOCATIONS SERVICES

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

GUB. Ex d. Screw-on lid. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 8 sizes - IP66. Polyester coating. Cast mounting feet

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

PRODUCT ATEX IECEx UL ULC CSA Inmetro CUTR CQST ABS SIL IP Rating Page DB7 66 / DB12 66 / DB15 66 / DB1 DB3 DB3V DB3B

ELECTRICAL EX EQUIPMENT

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Datasheet - AZM 161SK-12/12RK-024

Operating Manual Distribution box

Rosemount 3490 Series

Approvals, Certificates and Conditions

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

XLFE-4/1. Borosilicate glass globe

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

IECEx Certificate of Conformity

Enclosure Heaters. Zone 1, Zone 2 & Safe Area

MANUAL CALL POINT Intrinsically Safe (EExia), Weatherproof BG3 Range ATEX

IECEx Certificate of Conformity

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

NGC-20-C-E and NGC-20-CL-E

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

Dräger Polytron 5720 IR Toxic Gas Detection

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

INSTRUCTION & SERVICE MANUAL

ProcessMaster, HygienicMaster FEX300, FEX500

Illumination unit For sight glass level indicator Model LGI

North American Cable Glands

Guide to Hazardous Location Approvals:

Earth-Rite II PLUS Static Earthing System

Transcription:

> Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied with reset key and lift flap > Optional extras include stainless steel lift flap, duty and tag labels www.stahl.de 13915E00 Yodalex range Conventional manual call points designed for use in Hazardous or harsh environments.the devices provide a manual interface emergency switch for a number of applications.mcp BG is a single action break glass device which is activated by breaking the frangible glass pane on the front side of the call point; this provides the user with a distinct trigger signal. MCP PB is a latching, double action, push button call point. Both devices can be equipped with a number of variants and accessories. ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x Explosion Protection Global (IECEx) Gas and dust IECEx BAS 08.0089X IEC 60079-0: 2011 / IEC 60079-1: 2007-04 / IEC 60079-31: 2008 Ex d IIC T6 Ta -55... +70 C Gb Ex tb IIIC T85 C Ta -55... +70 C Db IP66 Europe (ATEX) Gas and dust Certifications and certificates Certificates Baseefa 08ATEX0269X EN 60079-0: 2009 / EN 60079-1: 2007 / EN 60079-31: 2009 E II 2 G Ex d IIC T6 Ta -55... +70 C Gb E II 2 D Ex tb IIIC T85 C Ta -55...+70 C Db IP66 IECEx, ATEX, Brazil (INMETRO), India (PESO), Kazakhstan (TR), Russia (TR), Belarus (TR), Russia (Fire certificate) WebCode MCPA /1 Signalling Devices

Versions Break Glass (BG) 14716E00 Push Button (PB) Selection Table Version Enclosure colour Version Order number Art. no. Weight kg MCP red normal (R) Break Glass (BG) MCP/BG/SP/Ex/A+B+C+D/EU/R 205324 1.000 Manual Call Points, ATEX IECEx certification, Push Button (PB) MCP/PB/SP/Ex/A+B+C+D/EU/R 205334 1.000 standard devices MCP red normal (R) Break Glass (BG) MCP/BG/SP/EX/A+B+C+D/RU/R 212402 1.000 Manual Call Points, EAC TR certification, standard devices Push Button (PB) MCP/PB/SP/Ex/A+B+C+D/RU/R 206660 1.000 Note, variations and different unit colours are available, to order these please use the table below 04035E00 Type Code Variations MCP / _ / _ / _ / _ / _ / _ / _ / _ / _ / _ / _ Version break glass BG push button PB Contacts 1 change over SP 2 change over DP Explosion protection standard Ex Cable entries standard 4 x M20 with 3 x Ex d stopping plugs and 1 x dust cap glands to be ordered separately Certification ATEX IECEx EU EAC TR + Russian Fire certificate (break glass version only) RU Colour red - RAL 3001 R blue - RAL 5015 B green - RAL 6032 G yellow - RAL 1018 Y black - RAL 9005 BK yellow / black stripe YB red / black stripe RB A+B+C+D lift flap (break glass version only) LF end of line resistor *) EOL inline resistor *) IL end of line and inline resistor *) ILEOL *) only available for 1 change over (SP) Labels (please specify wording) LED signal duty label tag label LED D T Additional approvals L We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Signalling Devices /2

Technical Data Electrical data Rated operational voltage 12... 50 V DC, 12... 250 V AC Switching capacity DC 12... 30 V 3 A 30... 50 V 1 A AC 12... 250 V 5 A Contact element standard: 1 change-over contact optional: 2 change-over contacts Switch NO or NC System test Test key provided Ambient conditions Operating temperature range -40... +70 C Mechanical data Material Enclosure material glass fibre reinforced polyester (GRP) Surface finish two pack, acrylic polyurethane, various colour options Degree of protection IP66 acc. to IEC 60529 Cable entries 4 cable entries, supplied with (3x) Ex d stopping plugs and (1x) dust cap Position of cable entries 13952E00 16555E00 13951E00 Break glass call point Break glass call point with lift flap Push button call point Connection Terminals 7 way terminal block., 4 mm 2 Earth connection provided as standard LED status indication optional: red LED status indication (up to 24 V DC) Lift flap stainless steel (break glass version only) Duty label Metalised polyester, customer to specify wording / symbols (see main picture for example) Tag label Stainless steel tag with polyester label, customer to specify max 9 characters Resistors Customer to specify value Mounting / Installation Assembly and Spare Parts via holes through the back box see operating instruction for full details Designation Figure Description Order number Art. no. WebCode Cable gland Ex d Ex e Compound barrier cable CMP-20PXSS2K 109441 PXSS2KA gland for all types of unarmoured and braid armour cables (nickel plated 15793E00 brass) RapidEx liquid pour sealing system CMP-20PXSS2K-REX 246605 PXSS2KB Ex d Ex e Compound barrier cable CMP-20PX2K 109428 PX2KA gland for all types of armoured cables (SWA, braided, tape) (nickel plated 15791E00 brass) RapidEx liquid pour sealing system CMP-20PX2K-REX 246649 PX2KB Ex d Ex e cable gland for all types CMP-20A2F 243464 A2FA of unarmoured and braid armour cables (nickel plated brass) 14977E00 14978E00 Ex d Ex e cable gland for all types of armoured cables (SWA, braided, tape) (nickel plated brass) with unique compensating displacement seal system (CDS) CMP-20T3CDS 246561 T3CDSA /3 Signalling Devices

and Spare Parts Designation Figure Description Order number Art. no. WebCode 208727 Replacement break glass Replacement break glass pane; for use after initiation of alarm. Pack of 5 pieces. 18348E00 Test key for break glass Replacement test key; used to trigger alarm without breaking glass panel 209532 18347E00 Reset key for push button device Replacement reset key; used to reset alarm after initiation 209531 Fastening set adapter plates 18349E00 Adaptor plate for use in conjunction with pipe clamp 257011 Pipe clamp 18550E00 R 1 1 / 4 120812 R 1 1 / 2 120819 09349E00 R 2 120823 Sun shield 18551E00 Sun shield for use in conjuction with adaptor plate 256520 Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 27,24 ± 0,1 [1,07 ± 0,004] 78 [3,07] 39 [1,54] Ø 5,50 [Ø 0,22] 74 [2,91] 11,24 ± 0,1 [0,44 ± 0,004] 107,50 ± 0,1 [4,23 ± 0,004] 13953E00 Break glass manual call point 16544E00 18196E00 Duty label Tag label Lift flap 16554E00 Signalling Devices /4

Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 39 [1,54] Ø 5,50 [Ø 0,22] 78 [3,07] [1,07 ± 0,004] 27,24 ± 0,1 74 [2,91] 98 [ 3, 86] 107,50 ± 0,1 [4,23 ± 0,004] 11,24 ± 0,1 [0,44 ± 0,004] 13954E00 Push button manual call point 16545E00 18197E00 Duty label Tag label Signalling Devices /5