HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h

Similar documents
C13-Series Engineering Guide

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

VertiCool Aurora Engineering Guide

CoolSpot Engineering Guide

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

SKYPAK II, 3 Ton Series, gives you a

Advance Release September 2009

Commercial High-Efficiency Condensing Units

SKYPAK II, 3 Ton Series, gives you a

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

VariCool VAV Engineering Guide

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

SKYPAK II Heating & Cooling Self Contained Packages

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Concealed Ducted Split Series R-407C MBH

technical guide Water-Cooled Self-Contained Units

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PACKAGE AIR CONDITIONER

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility allow for timesaving

Split System Heat Pumps

Condensing Units & Air Handlers

TECHNICAL SPECIFICATIONS

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

DIRECT DRIVE BLOWER COILS

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

TECHNICAL SPECIFICATIONS

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

CoolSpot. Unique Solutions for All-Indoor HVAC Projects

Water-Cooled Self-Contained Units

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

General Description. Operation

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

Product Data. Fig. 1 - Unit 50VR -A

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

PAJ3. Product Specifications

MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

Unit Features & Benefits RQPM/RQRM Series

Operation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

WALL-MOUNT HEAT PUMPS - (60HZ)

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

36,000-62,000 BTUH Nominal Capacity

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

PAR5. Product Specifications

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

R4H4. Product Specifications

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

50TM TFF COMBINATION HEATING/COOLING UNITS

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

50TM COMBINATION HEATING/COOLING UNITS

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS

FILTERS MANIFOLD CABINET REFRIGERANT CONNECTION LOCATION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

R4H4. Product Specifications

Transcription:

AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h HORIZONTAL SERIES MiniPac HU024, HU036, HU048, HU060 DualPac HU072, HU096 MaxPac HU120, HU144, HU180 Horizontal packaged selfcontained, air cooled air conditioning systems. AirPac units are compact and fit where others can t. All units fit through a 32" doorway. Cabinet heights of 22" for 2-, 3-, 4- and 5-ton cabinet; 27" for 6-and 8-ton cabinet and only 29" for the 10-, 12-, and 15-ton cabinet. Versatile units adapt to your application to save you money. Self-sealing refrigeration valves mean you won t lose the factory charge when splitting units in the field. Duct runs can be minimized condenser and evaporator can be split up to 150' equivalent lengths. External static pressure is adjustable from 0.1" to 1.0" on both the evaporator and condenser with oversized blowers, cast iron pulleys and adjustable motor sheaves. 24 VAC control circuit with oversized transformer works with a variety of thermostats. Quality components and construction ensure safety and extend equipment life. Full stainless steel condensate pan will not rust. Condensate carry-over is greatly reduced since all coils have an oversized face area. Refrigeration circuit is protected by high and low pressure safety switches, loss of air switch and a filter drier in each circuit. All models are approved by ETL, City of New York MEA and comply with Chicago Code, when specified. Units are quiet when operating. Acoustic and thermal protection result from vapor sealed bottom pans and fully insulated cabinets. Motor/blower vibration is greatly reduced by mounting motors on adjustable motor mounts. Quiet operation is ensured since compressors are externally spring mounted with discharge mufflers. Service is easy. Units can be serviced in the ceiling with removable compartment panels on both sides. No guess work about the refrigeration charge or moisture level when using the sight glass and moisture indicator in each circuit. Service calls are reduced and equipment life extended with inherently protected motors and compressors. The horizontal series saves valuable floor space and offers application flexibility. The MiniPac, DualPac and MaxPac units are perfect for cooling applications in new, historic and retrofit properties: Mid- to High-rise Buildings Schools and offices Computer Rooms & Telecom Rooms Laboratories Stadiums and Arenas Warehouses and Factories 2002/2003 AirPac, Inc. toll-free: 888-324-7722 fax: 540-622-2634 AirPac 21

Conditioned Air Evaporator Supply Evaporator Return Room Air Features and Benefits of Horizontal Series Cabinet heights of 22" for 2-, 3-, 4- and 5-ton unit, 27" for 6- and 8-ton unit, and only 29" for 10-, 12- and 15-ton unit. AirPac units fit where others can't. All units fit through 32" doorway. Removable compartment panels on both sides. Completely serviceable in the ceiling. No need to lower unit. ETL listed and labeled. MEA approved 141-91-E. Ensures user safety. Horizontal Series Split Configuration Horizontal Series Packaged Configuration: MiniPac, DualPac or MaxPac Condenser Discharge Warm Air Condenser Intake Field splitable in minutes with no loss of factory charge. Adaptable unit saves time and money on the install. Condenser and evaporator can be split up to 150' equivalent lengths. Units are versatile to meet your requirements. Tubing can be run rather than costly duct work. Vapor sealed bottom pans with fiberglass lined cabinet. Provide acoustic and thermal protection. Full stainless steel condensate pan. Condensate pan will not rust or degrade. Oversized face area on all coils. Eliminates condensate carry-over and allows for higher sensible heat ratio. Oversized belt driven ball-bearing centrifugal blowers, cast iron pulleys, and adjustable motor sheaves. Flexible field adjustable ESP from 0.1" to 1.0" on both the evaporator and condenser with standard motors and blowers. Motors mounted on base mounted adjustable motor mounts--not on blowers. Reduce motor/blower noise and make motors and blowers easier to service. Inherently protected motors and compressors. Reduce service calls and extend equipment life. High and low pressure safety switches with lockout relay, loss of air flow switch, and filter drier in each circuit. Protect the refrigeration circuit and ensure trouble-free operation. All compressors externally spring mounted with discharge mufflers. Ensure quiet operation. Adjustable expansion valve with external equalizer in each circuit. Adjustable superheat for each application. Sight glass and moisture indicator in each circuit. No need to guess about refrigeration charge or moisture level. 24 VAC control circuit with oversized transformer. No high voltage thermostat wiring. Works with wide variety of thermostats. 2" pleated extended surface type filters mounted in each unit. No need to fabricate and install field mounted filter racks. 22 AirPac Visit The Coolest Site on the Web www.airpacinc.com CAT2 10M 12/02 AG

MiniPac 2-, 3-, 4- & 5-Ton Single-Compressor Air Conditioning System Dimensional Data HU024, HU036, HU048, HU060 Weight (lbs) HU024 HUO36 HU048 HU060 630 690 HORIZONTAL SERIES Cabinet Dimensions (inches) HU024, HUO36, HU048, HU060 A 66-1/4 B 34-3/4 C 31-1/2 D 22 E 47-3/8 Cond Intake, height: F 16 Conde Intake, width: G 16 Evap Return, height: H 18 Evap Return, width: I 24 Cond Discharge, height: J 16 Cond Discharge, width: K 16 Evap Supply, height: L 16 Evap Supply, width: M 16 N 10-1/2 O 2-3/4 P 2-3/8 Q 1-1/4 R 1 S 1-1/4 T 1-1/8 U 53 V 50-1/2 W 4-1/4 X 6-1/2 Y 20-1/2 Z 4 AA 7-1/2 BB 22-1/4 CC 21-1/2 2002/2003 AirPac, Inc. toll-free: 888-324-7722 fax: 540-622-2634 AirPac 23

H U Horizontal 0 6 0 - A 3 S Evap. & Cond. Unit BTU Capacity Air Cooled 1=208/230/1/60 3=208/230/3/60 4=460/480/3/60 S=Single Compressor D=Dual Compressor T=Triple Compressor Performance Data for MiniPac Series Nominal Evaporator Condenser E.A.T. 75 Ambient 95 Ambient Tons CFM* Fan Size CFM* Fan Size DB WB Total Sensible Total Sensible 86 72 30,000 22,000 28,000 20,000 2 800 12 x 9 1600 12 x 9 80 67 29,000 21,000 27,000 19,000 75 62 28,000 20,000 26,000 18,000 86 72 46,000 30,000 42,500 29,800 3 1200 12 x 9 2000 12 x 9 80 67 43,000 29,000 39,500 27,000 75 62 41,000 28,000 35,000 24,800 86 72 59,000 40,000 55,000 36,000 4 1600 12 x 9 2000 12 x 9 80 67 58,000 39,000 51,000 35,000 75 62 50,000 38,000 46,000 34,000 86 72 74,000 51,000 68,000 46,600 5 2000 12 x 9 3100 12 x 9 80 67 70,000 49,000 63,000 45,000 75 62 65,000 47,000 58,000 43,600 *CFM field adjustable from 0.1" to 1.0" external static pressure. Electrical Data for MiniPac Series Packaged Unit Installation Nominal Compressor Condenser Motor Evaporator Motor Main Circuit Max. Fuse Tons Model Voltage LRA RLA HP FLA HP FLA Ampacity Size HU024-A1S 208/230/1/60 54 12.9 0.75 5.8 0.50 3.8 25.7 35 2 HU024-A3S 208/230/3/60 73 8.7 0.75 2.5 0.50 1.9 15.3 25 HU024-A4S 460/480/3/60 23 4.2 0.75 1.3 0.50 1.0 7.6 10 HU036-A1S 208/230/1/60 93 22.5 1.0 7.0 0.75 5.8 40.9 60 3 HU036-A3S 208/230/3/60 110 14.3 1.0 3.1 0.75 2.5 23.5 35 HU036-A4S 460/480/3/60 39 5.2 1.0 1.6 0.75 1.3 11.3 15 4 HU048-A4S 460/480/3/60 45 6.3 1.5 2.2 1.0 1.6 14.1 20 HU048-A3S 208/230/3/60 130 16.8 1.5 4.4 1.0 3.1 28.5 40 5 HU060-A3S 208/230/3/60 150 21.4 3.0 8.2 1.5 4.4 39.4 60 HU060-A4S 460/480/3/60 62 8.8 3.0 4.1 1.5 2.2 18.3 25 Electrical Data for MiniPac Series Split Unit Installation Condensing Unit Evaporator Nominal Compressor Condenser Motor Min. Circuit Max. Fuse Evaporator Motor Max. Fuse Tons Model Voltage LRA RLA HP FLA Ampacity Size HP FLA Size HU024-A1S 208/230/1/60 54 12.9 0.75 5.8 21.9 35 0.50 3.8 4.5 2 HU024-A3S 208/230/3/60 73 8.7 0.75 2.5 13.4 20 0.50 1.9 2.5 HU024-A4S 460/480/3/60 23 4.2 0.75 1.3 6.6 10 0.50 1.0 1.5 HU036-A1S 208/230/1/60 93 22.5 1.0 7.0 35.1 50 0.75 5.8 7.0 3 HU036-A3S 208/230/3/60 110 14.3 1.0 3.1 21.1 35 0.75 2.5 3.0 HU036-A4S 460/480/3/60 39 5.2 1.0 1.6 10.1 15 0.75 1.3 1.5 4 HU048-A4S 460/480/3/60 45 6.3 1.5 2.2 12.5 20 1.0 1.6 2.0 HU048-A3S 208/230/3/60 130 16.8 1.5 4.4 25.4 40 1.0 3.1 3.5 5 HU060-A3S 208/230/3/60 150 21.4 3.0 8.2 35.1 50 1.5 4.4 5.5 HU060-A4S 460/480/3/60 62 8.8 3.0 4.1 16.1 25 1.5 2.2 2.5 In the interest of product improvements, specifications are subject to change without notice. Current technical information available online or call 888-324-7722. City of New York MEA141-91-E Meets City of Chicago Code, when specified 24 AirPac Visit The Coolest Site on the Web www.airpacinc.com CAT2 10M 12/02 AG

DualPac 6- & 8-Ton Dual-Compressor Air Conditioning System Dimensional Data HU072, HU096 Weight (lbs) HU072 HU096 860 900 HORIZONTAL SERIES Cabinet Dimensions (inches) HU072, HU096 A 71-3/4 B 40-3/8 C 31-3/8 D 27 E 55-1/4 Cond Intake, height: F 20 Cond Intake, width: G 18 Evap Return, height: H 23 Evap Return, width: I 32 Cond Discharge, height: J 20 Cond Discharge, width: K 18 Evap Supply, height: L 18 Evap Supply, width: M 16 N 15-1/8 O 2-3/4 P 2-3/8 Q 1-1/4 R 3-1/2 S 2-1/4 T 1-1/8 U 61 V 59 W 3-1/2 X 6-1/2 Y 20-1/2 Z 4 AA 7-1/2 BB 22-1/4 CC 27-1/4 2002/2003 AirPac, Inc. toll-free: 888-324-7722 fax: 540-622-2634 AirPac 25

H U Horizontal 0 6 0 - A 3 S Evap. & Cond. Unit BTU Capacity Air Cooled 1=208/230/1/60 3=208/230/3/60 4=460/480/3/60 S=Single Compressor D=Dual Compressor T=Triple Compressor Performance Data for DualPac Series Nominal Evaporator Condenser E.A.T. 75 Ambient 95 Ambient Tons CFM* Fan Size CFM* Fan Size DB WB Total Sensible Total Sensible 86 72 89,000 66,000 80,000 58,000 6 2400 12 x 9 3800 15 x 9 80 67 85,000 64,000 76,000 57,000 75 62 81,000 62,000 72,000 56,000 86 72 115,000 86,000 101,000 75,000 8 3200 12 x 9 4250 15 x 9 80 67 108,000 81,000 100,000 73,000 75 62 105,000 79,000 94,000 71,000 *CFM field adjustable from 0.1" to 1.0" external static pressure. Electrical Data for DualPac Series Packaged Unit Installation Nominal Compressor Condenser Motor Evaporator Motor Main Circuit Max. Fuse Tons Model Voltage LRA RLA HP FLA HP FLA Ampacity Size 6 8 HU072-A3D 208/230/3/60 110 12 2.0 6.0 2.0 6.0 39.0 50 HU072-A4D 460/480/3/60 39 5.2 2.0 3.0 2.0 3.0 18.6 25 HU096-A3D 208/230/3/60 130 16.8 3.0 8.2 3.0 8.2 54.2 70 HU096-A4D 460/480/3/60 45 6.3 3.0 4.1 3.0 4.1 26.7 35 Electrical Data for DualPac Series Split Unit Installation Condensing Unit Evaporator Nominal Compressor Condenser Motor Min. Circuit Max. Fuse Evaporator Motor Max. Fuse Tons Model Voltage LRA RLA HP FLA Ampacity Size HP FLA Size 6 8 HU072-A3D 208/230/3/60 110 12 2.0 6.0 33.0 40 2.0 6.0 7.5 HU072-A4D 460/480/3/60 39 5.2 2.0 3.0 15.6 20 2.0 3.0 3.5 HU096-A3D 208/230/3/60 130 16.8 3.0 8.2 46.0 60 3.0 8.2 10.0 HU096-A4D 460/480/3/60 45 6.3 3.0 4.1 22.6 30 3.0 4.0 5.0 In the interest of product improvements, specifications are subject to change without notice. Current technical information available online or call 888-324-7722. City of New York MEA141-91-E Meets City of Chicago Code, when specified 26 AirPac Visit The Coolest Site on the Web www.airpacinc.com CAT2 10M 12/02 AG

MaxPac 10-, 12- & 15-Ton Multi-Compressor Air Conditioning System Dimensional Data HU120, HU144, HU180 Weight (lbs) HU120 HU144 HU180 1340 1440 1490 HORIZONTAL SERIES Cabinet Dimensions (inches) HU120, HU144, HU180 A 89-7/8 B 55-1/8 C 34-3/4 D 29 E 70-3/8 Cond Intake, height: F 24 Cond Intake, width: G 30 Evap Return, height: H 25 Evap Return, width: I 46-1/4 Cond Discharge, height: J 24 Cond Discharge, width: K 24 Evap Supply, height: L 20 Evap Supply, width: M 18 N 12-1/8 O 1-3/4 P 2-3/8 Q 1-1/4 R 2-1/4 S 2-1/4 T 1-1/8 U 74 V 72 W 3-1/2 X 6-1/2 Y 20-1/2 Z 4-1/2 AA 7-1/2 BB 25-1/4 CC 43 2002/2003 AirPac, Inc. toll-free: 888-324-7722 fax: 540-622-2634 AirPac 27

H U Horizontal 0 6 0 - A 3 S Evap. & Cond. Unit BTU Capacity Air Cooled 1=208/230/1/60 3=208/230/3/60 4=460/480/3/60 S=Single Compressor D=Dual Compressor T=Triple Compressor Performance Data for MaxPac Series Nominal Evaporator Condenser E.A.T. 75 Ambient 95 Ambient Tons CFM* Fan Size CFM* Fan Size DB WB Total Sensible Total Sensible 86 72 148,000 107,000 132,000 95,000 10 4000 15 x 9 6000 15 x 15 80 67 136,000 102,000 125,000 94,000 75 62 127,000 101,000 115,000 92,000 86 72 178,000 124,000 154,000 110,000 12 4800 15 x 9 6000 15 x 15 80 67 160,000 120,000 144,000 108,000 75 62 147,000 117,000 135,000 105,000 86 72 226,000 200,000 219,000 179,000 15 5400 15 x 9 6300 15 x 15 80 67 219,000 191,000 197,000 169,000 75 62 206,000 178,000 183,000 150,000 *CFM field adjustable from 0.1" to 1.0" external static pressure. Electrical Data for MaxPac Series Packaged Unit Installation Nominal Compressor Condenser Motor Evaporator Motor Main Circuit Max. Fuse Tons Model Voltage LRA RLA HP FLA HP FLA Ampacity Size 10 12 15 HU120-A3D 208/230/3/60 150 12 5.0 14.0 3.0 8.2 70.4 90 HU120-A4D 460/480/3/60 62 8.8 5.0 7.0 3.0 4.1 32.7 45 HU144-A3T 208/230/3/60 130 16.8 5.0 14.0 5.0 13.0 81.6 100 HU144-A4T 460/480/3/60 45 6.3 5.0 7.0 5.0 6.5 40.2 50 HU180-A3T 208/230/3/60 150 16.8 5.0 14.0 5.0 13.0 96.5 120 HU180-A4T 460/480/3/60 62 8.8 5.0 7.0 5.0 6.5 44.7 55 Electrical Data for MaxPac Series Split Unit Installation Condensing Unit Evaporator Nominal Compressor Condenser Motor Min. Circuit Max. Fuse Evaporator Motor Max. Fuse Tons Model Voltage LRA RLA HP FLA Ampacity Size HP FLA Size 10 12 15 HU120-A3D 208/230/3/60 150 12 5.0 14.0 62.2 90 3.0 8.2 15.0 HU120-A4D 460/480/3/60 62 8.8 5.0 7.0 28.6 40 3.0 4.1 10.0 HU144-A3T 208/230/3/60 130 16.8 5.0 14.0 68.6 90 5.0 13.0 25.0 HU144-A4T 460/480/3/60 45 6.3 5.0 7.0 33.6 45 5.0 6.5 15.0 HU180-A3T 208/230/3/60 150 16.8 5.0 14.0 83.5 110 5.0 13.0 25.0 HU180-A4T 460/480/3/60 62 8.8 5.0 7.0 38.2 45 5.0 6.5 15.0 In the interest of product improvements, specifications are subject to change without notice. Current technical information available online or call 888-324-7722. City of New York MEA141-91-E Meets City of Chicago Code, when specified 28 AirPac Visit The Coolest Site on the Web www.airpacinc.com CAT2 10M 12/02 AG