MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

Similar documents
PRODUCT SPECIFICATIONS

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

13 SEER CONDENSING UNITS & AIR HANDLERS

Condensing Units & Air Handlers

13 SEER CONDENSING UNITS

16 SEER TWO-STAGE AIR CONDITIONERS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Specifications and Performance S2H

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units

TECHNICAL SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

TECHNICAL SPECIFICATIONS

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

PRODUCT SPECIFICATIONS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

WCH5**4. Product Specifications

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

MACH N-407 Heat Pump Air-Cooled Chiller

RSG16**S1M. Split System Air Conditioner 16 SEER

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

R4H4. Product Specifications

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

TZPL SERIES. Applications Thermal Zone remote heat pumps offer comfort and dependability for single, multi-family and light commercial applications.

MAC N-407 Air-Cooled Chiller

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

2 shp 13 lc 1 36 t - 1 a

R4H4. Product Specifications

TECHNICAL SPECIFICATIONS

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

N4H4. Product Specifications

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant 14PJM SERIES

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL SPECIFICATIONS

PRODUCT SPECIFICATIONS

Ruud Achiever Series Air Conditioners

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL SPECIFICATIONS

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

AIR HANDLERS AIR HANDLERS

14 AC x

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

General Description. Operation

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Whirlpool Split System 13 SEER Air Conditioner W2C3. Features

PAJ3. Product Specifications

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

PACKAGE AIR CONDITIONER

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

seer 4HP16LT Split System Enhanced Heat Pump Features and Benefits WARRANTY

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

Indoor Air Handlers with Compressors MVS and MVW

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

MAC-120HE-03 Air-Cooled Chiller

N4A6. Product Specifications

DSXC18 Split System Air Conditioner

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

WJH4 Product Specifications

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

14+ SEER R-410a AIR CONDITIONERS. Aluminum Coil Series. Efficiencies up to 14+ SEER/12 EER. Nominal Sizes Ton. Capacities 16.

Samsung 360 Cassette, Single Zone, Split System

Advance Product Data

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

16 SEER Split System Enhanced Heat Pump 4SHP16LT. Features and Benefits WARRANTY

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

Transcription:

Air Conditioning and Heating SPECIFICATION sheet MHH 13 SEER High Efficiency R410a Split System Heat Pump Standard features: R410a system High efficiency compressor Compact design for easy installation and transportation Ultra quiet Factory installed liquid line filter drier Pre-charged R410a good for 25' of lineset Brass liquid and suction service valves with sweat connections Contactor with lug connections Ground lug connection Terminal block provided for low voltage connections High and low pressure switch included Crankcase heater is included Copper Tube-Aluminum Fin Coil used on all models ARI certified ETL listed Cabinet features: Heavy gauge galvanized steel with gray powder paint finish Fully louvered removable coil guard to protect condenser surface Easy access to service valves and electrical connections Easy access to fan motor without disconnecting wires www.comfortstarusa.com

SPECIFICATION sheet MHH 7 Models MHH18-410 MHH24-410 MHH30-410 MHH36-410 MHH42-410 MHH48-410 MHH60-410 13 SEER High Efficiency R410a General Terms of Limited Warranty ComfortStar USA warrants that our products conform to the manufacturer specifications and will be free of defects in material and workmanship under normal use and maintenance. For complete details of the limited warranty, including applicable terms and conditions, see your local distributor or contact the manufacturer for a copy. Model Number Identification MHH 18 410 13 SEER capacity R410a series 18,000 (Btu/h) HEAT PUMP Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all federal, state, provincial, and local codes, regulations and practices.

Condensing Unit Refrigerant Line Set Information Suction line Sizing Unit Size 1 1/2 Ton 2 Ton 2 1/2 Ton 3 Ton 3 1/2 Ton 4 Ton 5 Ton Suction Line Connection Size standard 3/4" I.D. 3/4" I.D. 3/4" I.D. 3/4" I.D. 3/4" I.D. 7/8" I.D. 7/8" I.D. Suction Line Run - Feet optional 5/8" 5/8" 5/8" 5/8" 5/8" 3/4" 1 1/8" 25' 50' 100' 150' Capactiy Factor standard 1.00 1.00 1.00 1.00 1.00 1.00 0.99 optional 1.00 1.00 1.00 1.00 1.00 1.00 1.00 standard 0.98 0.98 0.98 0.99 0.98 0.98 0.98 optional 0.97 0.97 0.97 0.97 0.98 0.98 0.99 standard 0.95 0.95 0.96 0.97 0.97 0.97 0.94 optional 0.94 0.94 0.94 0.94 0.95 0.95 0.98 standard 0.92 0.92 0.93 0.96 0.96 0.96 0.90 optional 0.90 0.90 0.90 0.90 0.91 0.92 0.97 Notes: * Standard size Using suction line larger than shown in chart will result in poor oil return and is not recommended. Liquid line Sizing System Capacity Liquid Line Connection Size (inch I.D.) Compressor Type Line Size Connection and Line Size (inch I.D.) Liquid Line Size Outdoor Unit above or below indoor coil Total Equivalent Length - Feet 25 50 75 100 125 150 Maximum Vertical Separation - Feet 1 1/2 Ton 3/8" Rotary 3/8* 25 30 30 27 24 20 2 Ton 3/8" Rotary 3/8* 25 30 30 24 20 15 2 1/2 Ton 3/8" Rotary 3/8* 25 30 30 22 17 10 3 Ton 3/8" Scroll 3 1/2 Ton 3/8" Scroll 4 Ton 3/8" Scroll 5 Ton 3/8" Scroll 5/16 25 50 37 22 7 N/A 3/8* 25 50 68 63 58 53 5/16 25 23 4 N/A N/A N/A 3/8* 25 50 43 36 30 24 3/8* 25 46 38 30 22 15 1/2 25 50 56 55 53 52 3/8* 25 50 56 44 32 20 1/2 25 50 75 81 79 76 Notes: * Standard size N/A Application not recommended 3

Electrical And Physical Data Dimensions NOTE: LOUVER APPEARANCE MAY VARY ACCESS VALVE FOR LOW PRESSURE ONLY ON FOR HEAT PUMP FUNCTION Dimensional Data Unit Model (Btu/h) Dimensions (inches) SUCTION LINE CONNECTION Refrigerant Connection Service Valve Size H in (mm) W in (mm) L in (mm) Liquid Suction 1 1/2 Ton (Cooling Unit) 24-15/16 (633) 21-7/8 (554) 21-7/8 (554) 3/8 3/4 1 1/2 Ton (Heat Pump Unit) 24-15/16 (633) 23-5/8 (600) 23-5/8 (600) 3/8 3/4 2 Ton 24-15/16 (633) 23-5/8 (600) 23-5/8 (600) 3/8 3/4 2 1/2 Ton 24-15/16 (633) 28 (710) 28 (710) 3/8 3/4 3 24-15/16 (633) 29-1/8 (740) 29-1/8 (740) 3/8 3/4 3 1/2 Ton 29-7/8 (759) 28 (710) 28 (710) 3/8 3/4 4 Ton 33-3/16 (843) 28 (710) 28 (710) 3/8 7/8 5 Ton 33-3/16 (843) 29-1/8 (740) 29-1/8 (740) 3/8 7/8

Specifications Model MHH18-410 MHH24-410 MHH30-410 MHH36-410 MHH42-410 MHH48-410 MHH60-410 Power supply V-Ph-Hz 1Ph-60Hz Cooling Heating Compressor Outdoor Fan Motor Outdoor Fan Blade Capacity Btu/h 18000 22400 29000 36000 42000 48000 56500 SEER Btu/h.W 13.00 13.00 13.00 13.00 13.00 13.00 13.00 Capacity Btu/h 17000 21500 29000 34500 43000 48000 57000 HSPF Btu/h.W 7.7 7.7 7.7 8.2 8.2 8.2 8.2 Model PA160X2CS- 3KUU PA200X2CS- 3MUU PA270X3CS- 3MUU Wire size should be determined in accordance with National Electrical Code Must use time-delay fuses or HACR type circuit breaker ZP31K5E- ZP36K5E- ZP42K5E- ZP51K5E- Type Rotary Rotary Rotary Scroll Scroll Scroll Scroll Brand Panasonic/ Toshiba Panasonic/ Toshiba Panasonic/ Toshiba Copeland Copeland Copeland Copeland Rated current (RLA) A 7 8.75 12 13.5 17.5 18.4 21.8 Locked rotor Amp (LRA) A 32.6 34.8 59.93 79 109 117 134 Capacito uf 40 50 55 45 45 70 70 Crankcase W 30 30 30 30 30 30 30 Type PSC Motor PSC Motor PSC Motor PSC Motor PSC Motor PSC Motor PSC Motor Horsepower HP 1/12 1/12 1/6 1/6 1/3 1/3 1/3 Rated current A 0.5 0.5 1 1 1.7 1.7 1.7 Capacitor uf 6 6 6 6 15 15 15 Speed RPM 1075 1075 825 825 1075 1075 1075 Type Axial flow fan Axial flow fan Axial flow fan Axial flow fan Axial flow fan Axial flow fan Axial flow fan Diameter inch 18-7/8 18-7/8 23 23-5/8 23 23 23-5/8 Outdoor air flow CFM 1600 1600 3100 3300 4300 4300 4500 Outdoor sound level (sound pressure level) Dimension Body (WxHxD) Packing (WxHxD) db(a) 57 57 62 63 67 67 66 inch inch 23-5/8" 23-5/8" 24-3/4" 24-3/4" 23-5/8" 23-5/8" 24-3/4" 24-3/4" 28" 28" 29" 29" 29-1/8" 29-1/8" 30-1/4" 30-1/4" 28" 29-7/8" 28" 29" 31-1/4" 29" 28" 33-3/16 " 28" 29" 34-1/2" 29" 29-1/8" 33-3/16" 29-1/8" 30-1/4" 34-1/2" 30-1/4" Net/Gross lbs 130/141 134/145 165/176 172/185 200/216 213/229 222/238 Charged refrigerant type Ozs R410a/102 R410a/102 R410a/123 R410a/129 R410a/150 R410a/167 R410a/167 Refrigerant piping Liquid/Suction inch 3/8 / 3/4 3/8 / 3/4 3/8 / 3/4 3/8 / 3/4 3/8 / 3/4 3/8 / 7/8 3/8 / 7/8 Max. refrigerant pipe length Max. elevation between outdoor unit and indoor unit ft 150 150 150 150 150 150 150 ft 33 33 33 50 50 50 50 Shipped with orifice size 0.054 0.061 0.068 0.068 0.08 0.09 0.108 MCA A 9.3 11.5 16 18 23.6 24.7 29.1 MOP A 15 20 30 30 40 40 50 Min/Max V V 197/253 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size Inch 1/2"/3/4"/1" 1/2"/3/4"/1" 1/2"/3/4"/1" 1/2"/3/4"/1" 1/2"/3/4"/1" 1/2"/3/4"/1" 1/2"/3/4"/1"

Outdoor Condenser Units Outdoor Condenser Indoor Coil or Air handler Cooling Capacity SEER EER Heating Capacity @ 47F Heating Capacity @ 17F HSPF HD2-18 18000 13 11.5 17000 10100 7.7 MHH-18-410 (U)AC1818A 16700 13 11.6 16900 10300 8 (U)AC1818B 18200 13 12.1 17900 10000 8.2 HD2-24 22400 13 10.5 21500 15100 7.7 MHH-24-410 (U)AC1824A 21500 13 11.1 21000 12800 8 (U)AC1824B 22000 13 11.4 22000 13000 8.5 HD2-30 29000 13 10.3 29000 18000 7.7 MHH-30-410 (U)AC2430A 26700 13 10.9 27900 16800 7.8 (U)AC2430B 27200 13 11.5 28200 16700 8.4 HD2-36 36000 13 11.5 34500 21200 8.2 MHH-36-410 (U)AC3036A 32100 13 10.8 33300 21800 8.2 (U)AC3036B 36000 13 11.6 36500 22900 8.5 (U)AC3036C 36800 13 12.4 35500 21400 9 HD2-42 42000 13 11 43000 26800 8.2 MHH-42-410 (U)AC3642B 37800 13 11.1 39600 23500 8.1 (U)AC3642C 40800 13 11 41100 24300 8.2 (U)AC3642D 39900 13 11.8 39600 23500 8.3 HD2-48 48000 13 11.1 48000 28600 8.2 MHH-48-410 (U)AC4248B 45400 13 10.6 46600 29400 8.3 (U)AC4248C 47300 13 10.9 47200 29100 8.5 (U)AC4248D 49100 13 12.3 47100 28700 8.5 HD2-60 56500 13 10.7 57000 35000 8.2 MHH-60-410 (U)AC4860C 54300 13 10.7 55200 35500 8 (U)AC4860D 57000 13 11.3 55700 34600 8.3 Field Installed Optional Accessories Thermostats: CP series: Horizontal non-programmable or programmable thermostat CVT series: Vertical non-programmable thermostat CDT series: Touch Screen programmable thermostat ComfortStar 12201 N.W. 107th Avenue Medley, FL 33178 toll free: 1-866-524-9898 fax: 305-500-9896 e-mail: info@comfortstarusa.com www.comfortstarusa.com Part no. MHH/SPEC-0909