Centro-Matic Automated Lubrication Systems System Controls

Similar documents
FDF Foam Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features

Gate Operator. Modfications

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Introduction to Flow Switch

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

LMR Electric Fire Pump Controllers Features

Transfer Switch Features

LMR Electric Fire Pump Controllers Features

Isco 3700ZR Sampler. Manual Set

H&O DIE SUPPLY, INC SPR-2000-JR. Programmable Fluid Controller Interstate 20 Kennedale, TX 76060

FX5 Series Explosion-Proof Electric Air Heaters

Across-the-Line SERIES MP300 Combined Manual and Automatic

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Variable Frequency Drive SERIES MP800 VFD

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Model A1600 Series Annunciator

CENTRO-MATIC - 278B. Model Controller Series C JAN Section - C8. Form Page. Indicates change

Soft Start Series MP700 Solid State, Reduced Voltage

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Transfer Switch Features

Section K CHLORINATION EQUIPMENT

High Pressure Conductivity Monitor

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

DGC-500 DIGITAL GENSET CONTROLLER

Field Certification Certificate of Compliance

Temperature Controllers

FT60 Reduced Voltage - Autotransformer

Oxygen (O2) Single-Point Gas Detection System

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

ELP21LU3-LF-HLOL THREE CHANNEL

T500 Elite - Hotbus Plant Wide Monitoring System for Bucket Elevators & Conveyors

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

D3000. Installation & Setup Guide

When reliability is vital. Alemite Carbon Shield TM Systems deliver

Technical Specification VFD

SECTION LOW VOLTAGE LIGHTING CONTROLS

Plug-in Base, Long Range Sensor E3B2

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

PARAGON Commercial Refrigeration Controls

vibration switch

FE1 Explosion-Proof Electric Air Heaters

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Variable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Dissolved Oxygen Analyzers

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

RHP120 RHP300 Steam Boiler Series

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes

Controllers. Instruction Manual WARNING

AS950 REFRIGERATED SAMPLERS

DGC-1000 DIGITAL GENSET CONTROLLER

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

Flopurge TS. Operation Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

I/O ZONE 560/583 AND OPERATION MANUAL

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

CR1 Series Triton Corrosion Resistant Washdown Heaters

DIGITAL METERS Large Display Temperature Meters Instruction Manual

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Product Manual SZ1145

Zircomat Oxygen Analyzers

Instruction Manual WARNING

LC1350 Level Controller

Ramsey Motion Monitoring Systems

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

T500 Elite MANUAL (Software Version 3.0.9)

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

7800 SERIES RM7888A Relay Module

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Med Touch Master Alarm

Duct and Rough Service Carbon Monoxide Sensor

INSTRUCTION MANUAL MODEL LDE 740. (Revised July 8, 2017)

E340 BOILER CONTROL INSTALLATION MANUAL

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

AS950 PORTABLE SAMPLERS

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof

Max Load. Max. Load. Red (+) Black (-) Gray Violet. Part number: CV 96 24DC. Solidrive constant voltage 0-10V dimmable LED driver

Commercial and Light Industrial Fire Alarm Control Panel

Call us today! (800)

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Pump-Up Controller MODEL 4062

Product Manual SZ1144

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Transcription:

Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the degree of automation and monitoring required. Your Lincoln representative will assist you in specifying the correct model. Options range from simple timers to fully-automated system controllers and monitors. Basic timers allow you to set the interval between lubrication cycles. More sophisticated monitors control the frequency of lubrication, oversee system performance and can sense lubricant flow to each bearing while showing system status and alarms on a LCD display panel. Monitors may be interfaced with machine control systems to protect your equipment from harm. You may customize your installation with air and lubricant filters to prolong system life, pressure gauges for monitoring, shut-off valves to ease future maintenance and even automated filling systems to utilize bulk lubricant storage. All of these possibilities, and more, have made Lincoln Automated Lubrication Systems the choice of industry for over 80 years. Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid valve (not included) installed in the air line to pump. Off Time On Time (Cycle Time) (Pumping Time) Power Approvals Switch Requirements Capacity Min Max Min Max 1 Min. 120/230 VAC 120 VAC, 5 Amps 20 Sec. 24 Hrs. 10 Sec. 24 Sec. 50/60 Hz UL, CSA 230 VAC, 1.5 Amps Built-In Program Options 3 Hr. Program Prelube Dimensions-in./mm Rating Memory Function Ambient Operating Temperature Range Minimum Maximum Yes No Yes No NEMA #1 8¹ ₄ 6¹³ ₁₆ 4¹⁵ ₁₆ 0 F 130 F 210 173 125-18 C 54 C Note: Refer to Technical Manual for a full explanation of available program options. Model 84511 Economy Timer for Single Stroke Pumps Uses a timing motor, cam and switch to turn pump off and on. NEMA 1 enclosure, UL and CSA listed. Switch capacity 10 amps non-inductive. Off Time On Time (Cycle Time) (Pumping Time) Power Approvals Switch Requirements Capacity Min Max Min Max 5 Min. 1 Hr. 30 Sec. 90 Sec. 120 VAC, 60 Hz UL, CSA 10 Amps Note: Off-time selectable in 5 minute intervals. Rating Dimensions - in. / mm NEMA 1 5 / 127 3¹ ₄ / 82.5 3¹ ₂ / 89 37

Model 84015 Timer 12-24V DC Solid-state microprocessor-based controller for automated lubrication systems on mobile equipment or where AC power is not available. Rugged construction with liquid- and dust-tight enclosure. Includes manual push-button for remote initiation of a lube cycle. Off Time** (Cycle Time) Min. Max. Fixed On Time Power Switch (Pumping Time) Requirements Capacity 10-30 VDC 2.5 Min. 80 Min. 75 Sec. 25 MA* * Less load. ** Available selections are 2.5, 5, 10, 20, 40 or 80 minutes. 5 Amps Rating NEMA 12 Ambient Operating Temperature Range Dimensions-in. / mm Minimum Maximum 5¹ ₄ / 133 3¹ ₈ / 79 3 / 76 0 F / -18 C 131 F / 55 C Model 85520 Programmable Controller Microprocessor-controlled, 120 volt AC unit is fully programmable. Controller has a wider off-time range than timers, features an adjustable pressure switch (280-3000 psi) and a memory switch to turn pre-lube option on or off. Off Time On Time (Pumping/ Switch Capacity (Cycle Time) Alarm Time) Power Inductive Load at 30VDC Requirements Min. Max. Min. Max. Load Relay Alarm Relay 30 Sec. 30 Hours 30 2 21-30 DC 2 2 Sec. Min. 100 MA* Amps Amps Rating Dimensions-in. / mm Ambient Operating Temperature Range Minimum Maximum NEMA 12 7¹ ₂ / 191 4¹⁵ ₁₆ / 125 3¹ ₂ / 89 0 F / -18 C 130 F / 55 C * Less load. Model 85525 Programmable Controller Same as Model 85520 except includes pressure switch and mounting brackets. Model 85535 System Controller 24V DC Same as Model 85520 except is a 24-volt DC. 38

Model 85530 Lubrication System Controller Controls lubrication frequency and monitors supply line pressure. The LCD displays operating status. Lube Cycle Timer Mode Counter Mode Off-Time Off-Counts Min. Max. Min. Max. 1. 9,900 1 99,000 Minute Minutes Count Counts * Minimum duration of count signal is 33 milliseconds. Max. Count Rate* 30/Sec. @ 50% Duty Cycle Pumping Time Before Alarm Min. Max. 1 99 Minute Minutes Power Requirements (less load) Pump, Ambient Solenoid, Temperature Dimensions-in. / mm Voltage Current or Alarm Range Rating Capacity 120 VAC, 50/60 Hz 85 MA 230 VAC, 50/60 HZ 45 MA 360 VA 32 to 122 F NEMA 9¹ ₂ 8¹⁵ ₁₆ 4¹ ₈ 0 to +50 C 12 241 227 105 24 VDC 250 MA 5 Amps Note: Model 85530 is CSA/NRTL approved. Model 85209 Panel Mounted Pneumatic Control System Panel mounted units control lubrication frequency and monitor supply line pressure. Includes Model 85530 Controller (specifications above), Model 69630 Pressure Switch and solenoid-operated air valve. Lube Cycle Pumping Timer Counter Max. Time Mode Mode Count Before Connections Off Time Off Counts Rate Alarm Min. Max. Min. Max. Min. Max. Air Lube 1 9,900 1 99,000 30/ 1 99 ³ ₈" ³ ₄" Minute Minutes Count Counts Sec. Minute Minutes NPTF(F) NPTF(F) Power Requirements External Ambient Panel Current Alarm Temperature Dimensions Voltage (less load) Load Range in. / mm Capacity Height Width 120 VAC, 60 Hz 32 to 122 F 12 18¹ ₄ 110 VAC, 50 Hz 47 VA 360 VA 0 to +50 C 305 464 Model 85208 Same as Model 85209 except 220 VAC, 50-60 Hz power. 39

Model 85500 System Sentry II The ultimate automated lubrication system controller/monitor now features greater monitoring accuracy with less sensitivity to lubricant flow rates, feed line length, or bearing back pressure. System Sentry II is always on the job, making sure that every lube point is lubricated when it s supposed to be. Solid-state controller with LCD status display and 16-button keypad for system programming Controls up to two pumps with as many as two lube zones per pump Fully programmable monitoring and alarm functions Be set up to monitor every lube point for lubricant flow during each lubrication event Easy to understand prompts reported by simple English language messages in real time Some functions require optional accessories. See chart on page 38. Use a maximum or 48 sensors and three accessory Sensor Boards (order separately 16 sensors per board) to monitor lube points. For more than 48 sensors, use Model 85510 Satellite plus additional Sensor Boards for a maximum of 1536 lube points. Lube Cycle Max. Pumping Time Timer Mode Counter Mode Off-Time Off-Counts Count Before Alarm Net Min. Max. Min. Max. Rate* Min. Max. Wt. 1 9,900 1 99,000 Second Minutes Count Counts * Minimum duration of count signal is 33 milliseconds. Note: Model 85500 is CSA/NRTL approved. * No external load, no sensors. 30/Sec. 1 99 18 lbs. @ 50% Second Minutes 8.1 kg Duty Cycle Power Requirements (less load) Pump, Ambient Solenoid, Temperature Dimensions-in. / mm Voltage Current or Alarm Range Rating Capacity 120 VAC, 50/60 Hz 250 MA* 230 VAC, 50/60 HZ 125 MA* 360 VA 32 to 122 F NEMA 11 14 4⁷ ₈ 0 to +50 C 12 241 227 105 24 VDC 600 MA* 5 Amps 40

Model 247333 Pressure Transducer Pressure Transducer signals actual system pressure via LCD display of System Sentry II. Comes with 72 inch (1.8m) shielded 24-gauge connecting wire. Maximum length of wire between transducer and monitor is 30 (9.1m) feet. Range Accuracy Proof Pressure Ambient Voltage Connection Temp. Input Output Offset NEMA 4X 0 to 7500 psig ¹ ₄" NPT -20 to 180 F 10 to 1-6 1 Rating 4000 psi ±1% 517 bar Male Thread -29 to 82 C 30 VDC VDC 300 Series 276 bar VDC Stainless Steel Model 250365 Sensor Board Plug-in accessory board used with Model 85500 that allows the attachment of up to 16 lube flow sensors. (Model 85500 comes without boards installed and can hold up to a total of three.) Sensor Assemblies Sensor assemblies consist of a check body and lube sensor with attached 30' cable. Cables are epoxy potted into the sensors for a watertight seal. Sensors have a 3 8" pipe thread for conduit connection and a Viton O-ring seal. Check bodies terminate in a 1 8" NPTF male thread for attachment to a bearing or other lubricant inlet. Maximum working pressure 6,000 psi (414 bar). Maximum wire run from sensor to monitor is 500 feet (152m). Lubricant Min. Flow Inlet/ Model Description Construction Temp. Range Per Event Outlet 250400 250490 250500 250590 Straight Sensor Assembly 90 Sensor Assembly Brass Sensor & Plated Steel Check Body Straight Sensor 316 Assembly Stainless Steel 90 Sensor Sensor & Assembly Check Body 32 to 145 F 0 to 63 C.004 cu.in./.066 cc @ 32 F / 0 C to 125 F / 52 C.008 in 3 /.131cc @ 126ºF / 53ºC to 145ºF / 63ºC Min. Interval Between Lube Flow Event 1/8" 30 Seconds Model 243100 Sensor Wire 100 foot (30.5 meters) coil of two conductor 22-gauge wire for connecting sensors to monitor. Maximum length of wire between sensor and monitor is 500 feet (152 meters). 41

Use This Guide to Select Accessories for Model 85500 System Sentry II Pressure Pressure Sensor Sensor Wire Function Switch Transducer Board Sensors #243100 (100') #69630 #247333 #250365 Note 2 Note 3 Lube Controller 1 Pump, 1 Zone Optional 1 Optional 1 Note 1 Lube Controller, Required 1 Pump, 1 per Zone Required 1 Up to 3 Zones (3 Max.) Lube Controller, Required 2 2 Pumps, 1 Zone No (1 per Pump) Per Pump Lube Controller, Required Required 2 2 Pumps, Up to 2 1 per Zone (1 per Pump) Zones Per Pump (4 Max.) Lube Point Required Required Required Monitoring 1 per each 1 per Quantity 48 Points 16 Sensors Lube Point As Needed Lube Point Required Required Required Monitoring 1 per each 1 per Quantity > 48 1536 Points 16 Sensors Lube Point As Needed Note 1: Controller may be operated without a pressure switch or pressure transducer but will not be able to monitor and alarm for lube system pressure failures. Note 2: Sensors include 30' (9.1m) cable pigtail. Select brass/plated steel or stainless steel sensors in straight or 90 configuration as required. Note 3: Maximum distance between monitor and sensor is 500' (152 meters). Note 4: Satellite monitor includes one 250365 sensor board and accepts two additional boards (optional) for connection of up to 48 sensors per satellite. Maximum 31 satellites per system. 42

Electric Solenoid-Operated Air Valves Electrical Characteristics Model Type Power Inrush Holding Air Ambient Cv Max. Conduit Requirements Current Current Inlet/ Temperature Factor Pressure Connection Amps Amps Outlet Range psi / bar 110 VAC, 50 Hz 350244 120 VAC, 60 Hz.11.07 4-Way 8.4 VA 0 to 120 F 220 VAC, 50 Hz -18 to 49 C 1.2 350245 240 VAC, 60 Hz.055.035 8.4 VA 1 4" 1 2" NPS(F) 110 VAC, 50 Hz NPT(F) 350241 120 VAC, 60 Hz.11.07 8.4 VA 150 220 VAC, 50 Hz 10.3 350242 240 VAC, 60 Hz.055.035.18 3-Way 8.4 VA 12 VDC 0 to 140 F 350282 6 Watts 1 8" -18 to 60 C N/A N/A 24 VDC NPT(F) 350283 6 Watts N/A 68586 2-Way 120V, 60 Hz 3 8" 12 VA.2.1 NPT(F) 2.4 1 2" NPT(F) 274398 3-Way 24 VDC 1 N/A N/A 4" 8.5 Watts NPT(F).5 N/A 244727 3-Way 110 VAC, 50 Hz 3 8" 0 to 120 F 120 VAC, 60 Hz.12.09 NPT(F) -18 to 49 C 11 VA 4.4 1 2" NPT(F) Model 249605 Sealed Cycle Timer Sealed timer attaches to Lincoln 16:1 Hydraulic Pumps and generates timed pulse signal to control pump reciprocating cycle rate. Power Cycle Rate/Minute Requirement Min. Max. 24 VDC 6 60 Model 84360 System Alarm System Alarm includes Model 84297 Reset Timer and Model 69630 Pressure Switch. Signals alarm if system pressure is not detected within preset intervals. Increasing Pressure Power Count Down Interval Reset Lube Switch Adjustment Requirement Before Alarm Signal Timer Connection psi / bar (less load) Min. Max. Min. Max. 115 VAC, 60 Hz 7.5 VA 9 Min. 5 Hours NEMA 1 ¹ ₄" NPTF(F) 280 / 19 3000 / 207 43

End-of-Line Monitors Designed to detect system pressure utilizing normally open or normally closed switch. Switch Operating Range - psig / bar Lube Dimensions - in / mm Conduit Model Rating Min. Max. Inlet Height Width Connection 83898 125, 250 1200 / 83 2500 / 172 ¹ ₄" 480 VAC, NPTF(F) 5³ ₄ / 146 2¹ ₄ / 57 ¹ ₂" NPSM 83899 15 Amps 700 / 48 1150 / 79 Model 83354 Signal Monitor Designed to provide visual and audible indication of system operation and failure. Utilizes signal from system controller. Includes Model 69606 Alarm Horn mounted on enclosure door. Indicator Lamps Power Requirement Power Lube System On System On Failure 115 VAC 50/60 Hz Green Amber Red 35 VA Note: Lamps and horn are U.L. listed. Audible Dimensions - in / mm Alarm 69606 Horn 10 8 6 (included) 254 203 152 Model 69606 Alarm Horn Use with controllers or System Alarm Model 84360 for audible failure signal. Model Power Requirement 69606 120 VAC, 50/60 Hz, 15 VA Note: U.L. listed. Model 69630 Pressure Switch Senses supply line pressure rise/fall to signal system operation to controller or system alarm. Switch Capacity Adjustable Range - psig / bar Connections Type Decreasing Increasing AC DC Lube Electrical Min. Max. Min. Max. Single Contact 10 Amps at 125, 250 or 480 VDC 15 Amps @ 6 VDC ²⁷ ₃₂" hole 5 Amps @ 24 VDC 250 2775 280 3000 for ¹ ₂".03 Amps @ 17 191 19 207 ¹ ₄" NPT(F) conduit 250 VDC connector Note: Pressure switch has a NEMA 3 housing and UL listed switching elements. 44