MERIT SERIES Upflow / Horizontal

Similar documents
MERIT SERIES Downflow

MERIT SERIES Downflow

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

ELITE SERIES Downflow - High Efficiency Blower Motor

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

MERIT SERIES Downflow

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

MERIT SERIES Upflow / Horizontal

ML 1 93 UH 070 x P 36 B

MERIT SERIES Upflow / Horizontal

8+* Bulletin No November 1997

MERIT SERIES Upflow / Horizontal

ML 1 80 UH 070 X E 36 B

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

MERIT SERIES Up Flow / Horizontal

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

13 GEP A L P - 1 A

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

ELITE SERIES Upflow / Horizontal - Two-Stage Heat

AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling to 5 Tons GAS FURNACES ML180UHE

ML180UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ. Net Input to 34.8 kw Nominal Add-on Cooling to 17.

ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

AFUE 95% Heating Input 50,000 to 200,000 Btuh

RGE 13 A T - 1 A

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

GSR21Q PULSE21 SERIES

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G34M Bulletin #69/ August 2003

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

MERIT Series R-410A - Upflow / Horizontal

TECHNICAL SPECIFICATIONS

EL195UH WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. EL195UH SERIES UNITS

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

MERIT Series R-410A - Upflow / Horizontal

TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

G41UF WARNING. Service Literature G41UF SERIES UNITS. Table of Contents

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

FG7T (C and L Series)

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

RG7D 1-Stage Heat Series

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

TECHNICAL SPECIFICATIONS

Heavy Duty Transformer. Low Voltage Circuit Breaker. Visit us at For the latest technical information,

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Cooling Capacity CFM range

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

G6RC Series TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

Cooling Capacity CFM in. w.c. (125 Pa)

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Cooling Capacity CFM in. w.c. (125 Pa)

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

Wt. Lbs Model Number (BTUH) Hz

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

G32V. Service Literature G32V SERIES UNITS

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

GHR32Q/V SERIES UNITS

Corp L12 Revised G24M SERIES UNITS

MERIT SERIES Up Flow / Horizontal

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Transcription:

PRODUCT SPECIFICATIONS GAS FURNACES ML95UH MERIT SERIES Upflow / Horizontal Bulletin No. 059 March 08 Supersedes February 08 AFUE - 95% Input - 44,000 to,000 Btuh Nominal Add-on Cooling - to 5 Tons MODEL NUMBER IDENTIFICATION ML 95 UH 070 X P 6 B Unit Type ML = Merit Series Stages = One-Stage AFUE 95 = 95% Configuration UH = Upflow/Horizontal Nominal Gas Heat Input 045 = 44,000 Btuh 070 = 66,000 Btuh 090 = 88,000 Btuh 0 = 0,000 Btuh 5 =,000 Btuh Cabinet Width B = 7-/ in. C = in. D = 4-/ in. Nominal Add-On Cooling Capacity 4 = tons 6 = tons 48 = 4 tons 60 = 5 tons Blower P = PSC Multi-Speed Blower Motor Low NO x X = Units meet California Nitrogen Oxides Standard (40ng/J) Indoor coils with the same letter designation will physically match the furnace.

FEATURES CONTENTS Blower Data... 9 Dimensions - Furnace/Coil Combined Dimensions... 5 Dimensions - Horizontal Position... Dimensions - Upflow Position... Features... Gas Heat Accessories... 8 High Altitude Derate... 9 Installation Clearances... 9 Model Number Identification... Optional Accessories... 8 Optional Accessory Dimensions... 4 Specifications... 7 Vent Lengths... 0 K B D H F E C G L WARRANTY Duralok Plus Aluminized Steel Heat Exchanger Limited twenty-year warranty in residential applications, ten years in non-residential applications. I J All other covered components - Limited five-year warranty in residential applications, one year in nonresidential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details. APPROVALS Units are AHRI Certified. Units tested and rated according to US DOE test procedures and FTC labeling regulations. Approved by the California Energy Commission and meets California Nitrogen Oxides Standard (NOx) limits of 40 ng/j. ISO 900 Registered Manufacturing Quality System. Blower data from unit tests conducted in Lennox Laboratory air test chamber. APPLICATIONS Input capacities of 44,000, 66,000, 88,000, 0,000 and,000 Btuh. Energy efficiency (AFUE) of 95%. Compact cabinet for upflow, horizontal-left or horizontalright applications without any modifications. Removable bottom seal panel shipped in place for side return air is easily removed for bottom/end return air applications. Utility room, alcove, closet, crawl space, basement or attic installation. Lennox add-on indoor coils, high-efficiency air cleaners and humidifiers can easily be added to furnace. Shipped factory assembled with all controls installed and wired. Each unit factory test operated to ensure proper operation. ML95UH / Page HEATING SYSTEM B Lennox Duralok Plus Heat Exchanger Assembly Lennox developed heat exchanger assembly consists of primary heat exchanger and secondary condenser coil assembly. Main multi-pass crimped seam design clamshell type heat exchanger. Constructed of heavygauge, aluminized-steel. Designed for normal expansion and contraction with maximum efficiency and minimum resistance to air flow. C Secondary heat exchanger condenser coil constructed of aluminum fins fitted to stainless steel tubes. Coil is factory tested for leaks. Condensate drain header box assembly located on front of coil. Compact size of complete heat exchanger assembly permits low overall design of furnace cabinet. All components mounted in a heavy-gauge steel frame. Heat exchanger assembly has been laboratory life cycle tested in excess of industry standards.

D E F G FEATURES HEATING SYSTEM (continued) Lennox Designed Header Box Header box on end of condenser coil collects flue condensate for disposal through condensate drains. The drains are located on each side of the cabinet for easy field installation of condensate drain trap. Only one drain is used, the other drain is sealed. Condensate drain trap is included with the unit for field installation. Lennox Designed Flue Condensate Trap Assembly Condensate trap assembly is mounted outside the conditioned air stream. Assembly can be mounted on either side of cabinet in upflow applications. Assembly is mounted on the bottom of the cabinet in horizontal applications. See Dimension Drawing and Installation Instructions. Can also be mounted remotely (up to 5 ft. away) from unit. 90 street elbow furnished for ease of drain trap installation. Drain connection can be made with field provided PVC pipe or PVC coupling. Drain cap on trap allows easy cleaning and winterizing. Inshot Burners Aluminized steel inshot burners provide efficient, trouble-free operation. Burner venturi mixes air and gas in correct proportion for proper combustion. Burner assembly is removable from the unit as a single component for ease of service. SureLight Integrated Furnaces Control Tough, reliable, long-life, trouble-free performance. Silicon nitride ignitor. Cemented to steatite block for protection against current leakage. Ignition leads are constructed of nickel-plated copper and are enclosed in high temperature Teflon insulation for dependable operation. Gas Control Valve 4 volt redundant combination gas control valve combines manual shut off switch (On-Off), automatic electric valve (dual) and gas pressure regulation into a compact combination control. Combustion Air Inducer Shaded pole heavy duty blower prepurges heat exchanger and safely vents flue products. Operates only during heating cycle. H Flame Rollout Switches () Manual reset switches are factory installed on the front of the burner box. Switch provides protection from abnormal operating conditions. Limit Control Automatic reset, primary limit is accurately located on the header box on all units. Optional Accessories 6K Derate Kit (045 models only) Allows 045 (44K input) models input to be reduced to 6K. For use with natural gas only. High Altitude Orifice Kits Required on all units for proper operation at altitudes from 750 to 0,000 ft. Kits are available for natural gas and LPG/propane. High Altitude Pressure Switch Kit Required for proper unit operation on installations above 4500 ft. Natural Gas to LPG/Propane Conversion Kit Required for field changeover from natural gas to LPG/ Propane. LPG/Propane to Natural Gas Conversion Kit Required for field changeover from LPG/Propane to natural gas. Muffler (US Only) Significantly reduces outdoor operating sound levels. Two-inch diameter muffler is optional for 045 through 0 input models. NOTE - Two-inch muffler is optional for the 0 input model with a maximum vent pipe length of up to 9 ft. Three-inch diameter muffler is optional for 0 and 5 input models. NOTE - Three-inch muffler is optional for the 0 input model with a minimum vent pipe length of 0 ft. Installed vertically in the exhaust piping. See Optional Accessory Dimension Drawing. Pressure Switch Proves Combustion Air Inducer operation before allowing gas valve to open. ML95UH / Page

FEATURES DIRECT VENT / NON-DIRECT VENT SEALED COMBUSTION SYSTEM Furnace features a sealed combustion system and can be installed in either Direct Vent or Non-Direct applications. In Direct Vent applications, combustion air is supplied from outdoors and flue gases are discharged outdoors. In Non-Direct Vent applications, combustion air is supplied from indoors and flue gases are discharged outdoors. NOTE - Lennox has approved the use of DuraVent PolyPro and Centrotherm InnoFlue manufactured vent pipe and terminations as an alternative to PVC vent pipe. Must be ordered separately. Tested and listed to the ULC S66 standard in Canada. The polypropylene venting system must follow the uninsulated and unconditioned space vent lengths listed in the table on Page. Refer to the Installation Instructions for additional details. Optional Accessories Termination Kits Facilitates installation of combustion air intake pipe and flue exhaust pipe. Refer to venting table in this bulletin to determine pipe size needed and proper termination kit required. See Optional Accessories table and dimension drawings. Termination Kit - Concentric - Direct Vent Applications or inch kit contains concentric termination assembly, reducer bushing and 45 elbow. inch kit for -045-070 models contains an outdoor exhaust accelerator. Kit requires single hole penetration of roof or wall for installation. Roof Termination Flashing Kit is available for use with inch Kits. CSA certified. Termination Kit - Flush-Mount Kit contains flush-mount termination, accelerator, mounting template and hardware. Kit may be used with, -/ or in. pipe. Termination Kits - Wall Assembly Close Couple (US Only) - Direct Vent Applications or inch kit consists of close-couple, side-by-side PVC piping with galvanized steel wall cover plate for sealing and isolating piping penetration of the wall. Piping spacing and length is sized for proper wall installations. CSA certified. ML95UH / Page 4 I Close Couple WTK (Canada Only) - Direct Vent Applications or inch kit contains one insulated faceplate, one insulated exhaust pipe, elbow and fittings. Wall Ring - Direct Vent or Non-Direct Vent Applications inch kit contains stainless steel outside seal caps, galvanized steel inside seal caps, 4 seal rings for the caps and 8 inch insulation sleeve for sealing and isolating intake and exhaust piping penetration of wall. Maintain a maximum of 6 inches between the inlet and outlet openings in the installation of the pipes. Roof Termination Flashing Kit or inch kit contains two neoprene rubber roof flashings for vertical venting through a roof. Vent pipe and insulation not furnished. Also available for use with inch (use inch flashing) Concentric Vent Termination Kits used in vertical venting rooftop applications. CONTROLS Integrated Furnace Control Contains all necessary controls and relays to operate furnace. Combustion air inducer is controlled by the integrated furnace control. Prior to ignition, a pre-purge cycle for 5 seconds is initiated. After the main burners are turned off, a post-purge cycle for 5 seconds is run. Integrated furnace control continuously monitors line voltage and maintains the igniter power at a constant level to provide consistent lighting and maximum igniter life. Flame sensor assures safe and reliable operation. Should loss of flame occur, the integrated furnace control will initiate 4 re-attempts at ignition before locking out unit operation for 60 minutes. Watchguard type circuit automatically resets integrated control after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service. Fan control consists of adjustable blower timed-off delay (60, 90, 0, 80 seconds - factory setting 0 seconds) and fixed blower timed-on delay (0 seconds heating, seconds cooling). For air-conditioning applications, blower is automatically energized on thermostat demand for cooling. Integrated furnace control has one red LED to indicate status and indicate diagnostic codes. Push button recall of the last 5 diagnostic codes aids in troubleshooting. Integrated furnace control has built-in twinning capability ( TWIN terminal on control) to operate two furnaces simultaneously without any additional controls. A field supplied isolation relay is required to operate the twinned (no thermostat connection) furnace. Two accessory terminals furnished for additional power supply requirements for 0 volt (less than amp) power humidifiers and powered air cleaners.

J FEATURES CONTROLS (continued) 4 Volt Transformer Furnished and factory installed in control box. 40VA transformer has fuse wired in series. Field Wiring Make-Up Box Furnished for line voltage wiring. Factory installed internally on left side of furnace. Box may be installed internally or externally on either side of furnace. Optional Accessories Thermostat Thermostat (programmable/non-programmable) is not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book for selection. Night Service Kit Contains most commonly used service parts: Furnace control Igniter Flame sensor Gas valve Transformer Service Manual BLOWER Multi-speed direct drive blower. Statically and dynamically balanced. Resiliently mounted. Blower assembly easily removed for servicing. Blower speeds are easily changed on the integrated furnace control. See Blower Data tables. K L CABINET Low-profile, narrow width cabinet allows easy installation in upflow or horizontal applications. Heavy-gauge, cold rolled steel construction. Pre-painted cabinet finish. Flanges provided on supply air opening for ease of plenum connection or alignment with indoor coil. Insulated cabinet with foil-faced insulation on sides and back of heating compartment. Sealed blower compartment. Complete service access. Safety interlock switch automatically shuts off power to unit when blower compartment access door is removed. Gas piping and electrical inlets are provided in both sides of cabinet. Return Air Entry: For bottom/end return-air entry for upflow/horizontal applications, remove furnished bottom seal panel from cabinet. For side return-air entry (upflow applications only), corners are marked on either side of cabinet for return air cut-outs. See Dimension Drawings. NOTE - 60C and 60D size units that require air volumes over 800 cfm must have one of the following:. Single side return air and Optional Return Air Base with transition that must accommodate required 0 x 5 x inch air filter to maintain proper velocity.. Bottom return air.. Return air from both sides. 4. Bottom and one side return air. See Blower Performance Tables for additional information. Coil Match-Up All furnaces exactly match Lennox cased upflow indoor coils and horizontal indoor coils with same letter designation (A, B, C, D) in model number. No adaptor required. Engaging holes furnished on cabinet for alignment. Lennox uncased coils match furnaces without any overhang but require an optional adaptor base or field fabricated transition to match furnace opening. See coil bulletin for additional information. Low Leakage Cabinet All models have less than % air leakage and meet ANSI/ASHRAE Standard 9-00 Method of Test for Determining the Air Tightness of HVAC Equipment. ML95UH / Page 5

FEATURES CABINET (continued) Optional Accessories Condensate Drain Heat Cable Kits Self-limiting wattage heat cable prevents condensate drain from freezing in unconditioned areas. Available in 6 or 4 ft. lengths. Horizontal Suspension Kit Provides suspension of unit and indoor coil in horizontal applications. Allows complete service access. Consists of corner mounted hanging brackets with vibration isolators, return air end support rail and hardware for assembly. Metal hanging straps must be field provided. Crawl Space Vent Drain Kit Allows venting through a crawl space for upflow and horizontal applications. Includes or in. sanitary tee, in. PVC assembly, PVC boot and clamp. Kit for Canada is certified to ULC S66. Return Air Base On furnaces with side return air and condensate trap on the same side of the cabinet, a field fabricated transition or Return Air Base is required when using an IAQ product higher than 4-/6 in. installed next to the unit and serviced from the front. IAQ products higher than 0 in. require a field fabricated transition. Must be used for 60C and 60D models with air volumes over 800 cfm in upflow applications when only one side return is required. Cabinet is shipped flat for easy field assembly and is pre-painted steel to match the furnace. See Dimension Drawing. FILTER (not furnished) Filter and provisions for external mounting must be field provided. Optional Accessories Air Filter and Rack Kit for Horizontal Return Air (End) Applications Washable or vacuum cleanable polyurethane frame type filter and external end return air rack available for field installation. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. See Dimension Drawing. Air Filter and Rack Kit for Upflow Side Return Air Applications - Not for use with Return Air Base Washable or vacuum cleanable polyurethane frame type filter and external side return air rack available for field installation. Available in single and ten pack kits. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. Field installs on either side of unit cabinet. See Dimension Drawing. High Performance Economizer (Commercial Applications Only) Designed for applications requiring outdoor air to be utilized in a commercial HVAC system. Allows the entry of fresh outdoor air for free cooling, reducing the requirement for mechanical cooling. Heavy gauge galvanized steel cabinet lined with thick fiberglass insulation. Mixed air sensor, outdoor air sensor and 4VAC transformer furnished. Approved for California Title 4 building standards. ASHRAE 90.-00 compliant. See separate Product Specifications bulletin for additional information and available control and sensor options. ML95UH / Page 6

SPECIFICATIONS Gas Heating Performance Model No. ML95UH 045XP4B ML95UH 045XP6B ML95UH 070XP6B ML95UH 090XP6C AFUE 95% 95% 95% 95% Connections in. Indoor Blower Electrical Data Input - Btuh 44,000 44,000 66,000 88,000 Output - Btuh 4,000 4,000 64,000 85,000 Temperature rise range - F 5-65 5-55 40-70 40-70 Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane.5 / 0.0.5 / 0.0.5 / 0.0.5 / 0.0 High static - in. w.g. 0.5 0.5 0.5 0.5 Intake / Exhaust Pipe (PVC) / / / / Gas pipe size IPS / / / / Condensate Drain Trap (PVC pipe) - i.d. /4 /4 /4 /4 with furnished 90 street elbow /4 slip x /4 Mipt /4 slip x /4 Mipt /4 slip x /4 Mipt /4 slip x /4 Mipt with field supplied (PVC coupling) - o.d. /4 slip x /4 MPT /4 slip x /4 MPT /4 slip x /4 MPT /4 slip x /4 MPT Wheel nom. dia. x width - in. 0 x 8 0 x 8 0 x 8 0 x 8 Motor output - hp /5 / / / Tons of add-on cooling.5 - -.5 - - Air Volume Range - cfm 90-40 700-605 650-585 655-60 Voltage 0 volts - 60 hertz - phase Blower motor full load amps. 6. 6. 6. Maximum overcurrent protection 5 5 5 5 Shipping Data lbs. - package 9 7 4 NOTE - Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. SPECIFICATIONS Gas Heating Performance Model No. ML95UH 090XP48C ML95UH 090XP60C ML95UH 0XP48C ML95UH 0XP60C ML95UH 5XP60D AFUE 95% 95% 95% 95% 95% Connections in. Indoor Blower Electrical Data Input - Btuh 88,000 88,000 0,000 0,000,000 Output - Btuh 85,000 85,000 05,000 06,000 6,000 Temperature rise range - F 40-70 0-60 40-70 40-70 45-75 Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane.5 / 0.0.5 / 0.0.5 / 0.0.5 / 0.0.5 / 0.0 High static - in. w.g. 0.5 0.5 0.5 0.5 0.5 Intake / Exhaust Pipe (PVC) / / / / / Gas pipe size IPS / / / / / Condensate Drain Trap (PVC pipe) - i.d. /4 /4 /4 / / with furnished 90 street elbow /4 slip x /4 Mipt /4 slip x /4 Mipt /4 slip x /4 Mipt /4 slip x /4 Mipt /4 slip x /4 Mipt with field supplied (PVC coupling) - o.d. /4 slip x /4 MPT /4 slip x /4 MPT /4 slip x /4 MPT /4 slip x /4 MPT /4 slip x /4 MPT Wheel nom. dia. x width - in. 0 x 0 -/ x 0 0 x 0 -/ x 0 -/ x 0 Motor output - hp / / Tons of add-on cooling - 4 4-5 - 4 4-5 4-5 Air Volume Range - cfm 900-40 90-445 75-000 5-485 5-595 Voltage 0 volts - 60 hertz - phase Blower motor full load amps 8..5 8..5.5 Maximum overcurrent protection 5 5 5 5 5 Shipping Data lbs. - package 47 5 59 64 77 NOTE - Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. ML95UH / Page 7

OPTIONAL ACCESSORIES - ORDER SEPARATELY CABINET ACCESSORIES B Width Models C Width Models D Width Models Horizontal Suspension Kit - Horizontal only 5W0 5W0 5W0 Return Air Base - Upflow only 50W98 50W99 5W00 High Performance Economizer (Commercial Only) 0U5 0U5 0U5 CONDENSATE DRAIN KITS Condensate Drain Heat Cable 6 ft. 6K68 6K68 6K68 4 ft. 6K69 6K69 6K69 Crawl Space Vent Drain Kit US 5W8 5W8 5W8 FILTER KITS Air Filter and Rack Kit SERVICE KIT Horizontal (end) Size of filter - in. 87L96-8 x 5 x Canada 5Z70 5Z70 5Z70 87L97-0 x 5 x 87L98-5 x 5 x Side Return Single 44J 44J 44J Ten Pack 66K6 66K6 66K6 Size of filter - in. 6 x 5 x 6 x 5 x 6 x 5 x Night Service Kit 68W80 68W80 68W80 TERMINATION KITS See Installation Instructions for specific venting information. Termination Kits - Direct Vent Applications Only Termination Kits - Direct or Non- Direct vent Concentric US - in. 7M80 69M9 - - - in. - - - 60L46 60L46 Canada - in. 44W9 44W9 - - - in. - - - 44W9 44W9 Flush-Mount US -, -/ or in. 5W 5W 5W Wall - Close Couple Wall - Close Couple WTK Roof Termination Flashing Kit - Direct or Non-Direct Vent ( flashings) Cleanable polyurethane frame type filter. Kits contain enough parts for two, non direct vent installations. Non-direct vent only. Canada -, -/ or in. 5W 5W 5W US - in. G44 - - - - - - in. 44J40 44J40 44J40 Canada - in. 0G8 - - - - - - in. 8J0 8J0 8J0 Roof in. 5F75 5F75 - - - Wall Ring Kit in. 5F74 5F74 - - - in. 44J4 44J4 44J4 NOTE - Termination Kits (44W9, 44W9, 0G8, 5W, 8J0) and Crawl Space Vent Drain Kit (5Z70) are certified to ULC S66 standard for use in Canada only. GAS HEAT ACCESSORIES Input High Altitude Pressure Switch Kit Natural Gas to LPG/Propane Kit LPG/Propane to Natural Gas Kit Natural Gas High Altitude Orifice Kit LPG/Propane High Altitude Orifice Kit 6K Derate Kit (Natural Gas) 450-7500 ft. 750-0,000 ft. 0-7500 ft. 0-7500 ft. 750-0,000 ft.750-0,000 ft. 0-0,000 ft. Muffler (US Only) 045 No Change U65 K49 7W8 7W7 K44 0K55 5Y66 (-inch) 070 U7 U64 K49 7W8 7W7 K44 - - - 5Y66 (-inch) 090 U70 U64 K49 7W8 7W7 K44 - - - 5Y66 (-inch) 0 U7 U64 K49 7W8 7W7 K44 - - - 5Y66 (-inch) 6A56 (-inch) 5 U70 U64 K49 7W8 7W7 K44 - - - 6A56 (-inch) NOTE - 6K Derate Kit information - Reduced Input is 6,000 Btuh, output is 4,00 Btuh. Two-inch diameter muffler (5Y66) is optional for 0 input model with a maximum vent pipe length of up to 9 ft. Three-inch diameter muffler (6A56) is optional for 0 input model with a minimum vent pipe length of 0 ft. ML95UH / Page 8

HIGH ALTITUDE DERATE NOTE - Units may be installed at altitudes up to 0,000 ft. At altitudes above 450 ft. the unit must be derated to match the manifold pressure information shown below. Units installed at altitudes of 450 to 0,000 ft. require a pressure switch change. Units installed at altitudes of 750 to 0,000 ft. require an orifice change. See the Gas Heat Accessories table for ordering information. NOTE - This is the only permissible derate for these units. NOTE - In Canada, certification for installations at elevations over 4500 feet is the jurisdiction of local authorities. Input All Sizes Gas Manifold Pressure in. w.g. 0-4500 ft. 450-5500 ft. 550-6500 ft. 650-7500 ft. 750-0,000 ft. Supply Line Pressure in. w.g. 0-0,000 ft. Natural.5....5 4.5.0 LPG/Propane 0.0 9.4 9. 8.9 0.0.0.0 OUTDOOR TERMINATION KIT USAGE Input Size 045 070 090 0 Vent Pipe Diameter (in.) Flush Mount Kit 5W (US) 4 5W (CA) Standard Terminations Wall Kit Wall Ring Kit inch inch inch G44 (US) 4 0G8 (CA) 44J40 (US) 4 8J0 (CA) 5F74 Field Fabricated Exhaust Accelerator Size Required Concentric Terminations Concentric Kit -/ inch inch inch 7M80 (US) 4 44W9 (CA) 69M9 (US) 4 44W9 (CA) 60L46 (US) 4 44W9 (CA) YES YES YES YES -/ in. YES - - - - - - -/ YES YES YES YES -/ in. YES - - - - - - YES YES YES YES -/ in. YES - - - - - - YES YES YES YES -/ in. YES - - - - - - -/ YES YES YES YES -/ in. YES - - - - - - YES YES YES YES -/ in. YES - - - - - - YES - - - YES YES in. - - - YES YES -/ YES - - - YES YES in. - - - YES YES YES - - - YES YES in. - - - YES YES YES - - - YES YES in. - - - YES YES -/ YES - - - YES - - - in. - - - YES YES YES - - - YES - - - in. - - - YES YES 5 YES - - - YES - - - in. - - - - - - YES NOTE - Standard Terminations do not include any vent pipe or elbows external to the structure. Any vent pipe or elbows external to the structure must be included in total vent length calculations. See Vent Length Tables. Requires field provided -/ in. outdoor exhaust accelerator. Concentric Kits 7M80 and 44W9 include -/ in. outdoor exhaust accelerator, required when used with 045 and 070 input models. Accelerator is not used with 090, 0, 5 input models. Flush Mount Kit 5W and 5W includes -/ in. outdoor exhaust accelerator, required when used with 045, 070 and 090 input models. Accelerator is not used with 0 or 5 input models. 4 Termination Kits 0G8, 44W9, 44W9, 5W and 8J0 are certified to ULC S66 standard for use in Canada only. INSTALLATION CLEARANCES - INCHES (MM) Sides Rear Top/Plenum Front Front (service/alcove) Floor 0 inches (0 mm) 0 inches (0 mm) inch (5 mm) 0 inches (0 mm) 4 inches (60 mm) Combustible NOTE Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ANSI Z.) or the National Standard of Canada CAN/CSA B49. Natural Gas and Propane Installation Code. NOTE In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ ANSI Z.) or applicable provisions of local building codes. In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CSA B49.. Allow proper clearances to accommodate condensate trap and vent pipe installation. Do not install the furnace directly on carpeting, tile, or other combustible materials other than wood flooring. ML95UH / Page 9

VENT LENGTHS - FEET STANDARD TERMINATION AT ELEVATION 0-4500 ft. Pipe Size in. -/ in. in. Input 045 070 090 0 5 045 070 090 0 5 045 070 090 0 5 No. of 90 ELL 8 66 44 4 N/A 5 5 9 58 N/A 8 7 8 8 89 76 6 9 9 N/A 0 0 88 5 N/A 84 7 56 4 4 N/A 05 05 8 48 N/A 8 7 08 08 79 4 66 5 9 N/A N/A 00 00 78 4 N/A 0 0 74 5 6 46 4 N/A N/A 95 95 7 8 N/A 8 7 98 98 69 6 56 4 9 N/A N/A 90 90 68 N/A 9 9 64 7 5 6 4 N/A N/A 85 85 6 8 N/A 08 07 88 88 59 8 46 N/A N/A N/A 80 80 58 N/A 0 0 8 8 54 9 4 6 N/A N/A N/A 75 75 5 8 N/A 98 97 78 78 49 0 6 N/A N/A N/A 70 70 48 N/A 9 9 7 7 44 STANDARD TERMINATION ELEVATION 450-0,000 ft. Pipe Size in. -/ in. in. Input 045 070 090 0 5 045 070 090 0 5 045 070 090 0 5 No. of 90 ELL 8 66 44 N/A N/A 5 5 9 58 N/A 8 7 8 8 89 76 6 9 N/A N/A 0 0 88 5 N/A 84 7 56 4 N/A N/A 05 05 8 48 N/A 8 7 08 08 79 4 66 5 9 N/A N/A 00 00 78 4 N/A 0 0 74 5 6 46 4 N/A N/A 95 95 7 8 N/A 8 7 98 98 69 6 56 4 9 N/A N/A 90 90 68 N/A 9 9 64 7 5 6 4 N/A N/A 85 85 6 8 N/A 08 07 88 88 59 8 46 N/A N/A N/A 80 80 58 N/A 0 0 8 8 54 9 4 6 N/A N/A N/A 75 75 5 8 N/A 98 97 78 78 49 0 6 N/A N/A N/A 70 70 48 N/A 9 9 7 7 44 CONCENTRIC TERMINATION AT ELEVATION 0-4500 ft. Pipe Size in. -/ in. in. Input 045 070 090 0 5 045 070 090 0 5 045 070 090 0 5 No. of 90 ELL 7 58 4 N/A 05 05 89 54 N/A 4 4 80 68 5 7 7 N/A 00 00 84 49 N/A 6 6 09 09 75 6 48 N/A 95 95 79 44 N/A 04 04 70 4 58 4 7 N/A N/A 90 90 74 9 N/A 06 06 99 99 65 5 5 8 N/A N/A 85 85 69 4 N/A 0 0 94 94 60 6 48 7 N/A N/A 80 80 64 9 N/A 96 96 89 89 55 7 4 8 N/A N/A 75 75 59 4 N/A 9 9 84 84 50 8 8 N/A N/A N/A 70 70 54 9 N/A 86 86 79 79 45 9 8 N/A N/A N/A 65 65 49 4 N/A 8 8 74 74 40 0 8 N/A N/A N/A 60 60 44 N/A N/A 76 76 69 69 5 CONCENTRIC TERMINATION ELEVATION 450-0,000 ft. Pipe Size in. -/ in. in. Input 045 070 090 0 5 045 070 090 0 5 045 070 090 0 5 No. of 90 ELL 7 58 4 N/A N/A 05 05 89 54 N/A 4 4 80 68 5 7 N/A N/A 00 00 84 49 N/A 6 6 09 09 75 6 48 N/A N/A 95 95 79 44 N/A 04 04 70 4 58 4 7 N/A N/A 90 90 74 9 N/A 06 06 99 99 65 5 5 8 N/A N/A 85 85 69 4 N/A 0 0 94 94 60 6 48 7 N/A N/A 80 80 64 9 N/A 96 96 89 89 55 7 4 8 N/A N/A 75 75 59 4 N/A 9 9 84 84 50 8 8 N/A N/A N/A 70 70 54 9 N/A 86 86 79 79 45 9 8 N/A N/A N/A 65 65 49 4 N/A 8 8 74 74 40 0 8 N/A N/A N/A 60 60 44 N/A N/A 76 76 69 69 5 ML95UH / Page 0

VENT LENGTHS - UNINSULATED EXHAUST PIPE IN UNCONDITIONED SPACE Winter Design Temperatures to F 0 to F 0 to 0 F Vent Pipe Diameter PVC Unit Input Size 045 070 090 0 5 PolyPro InnoFlue Maximum Un-Insulated Exhaust Vent Length (ft.) PVC PolyPro InnoFlue PVC PolyPro InnoFlue PVC PolyPro InnoFlue PVC PolyPro InnoFlue in. 8 6 8 50 48 0 0 N/A N/A -/ in. N/A 4 N/A 4 N/A 56 N/A N/A N/A in. 9 9 8 8 5 5 47 47 5 5 in. 9 8 8 6 9 0 0 N/A N/A -/ in. 5 N/A N/A 4 N/A 4 N/A N/A N/A in. N/A N/A 8 8 9 9 6 6 0 0 in. 5 N/A 0 9 0 7 N/A N/A -/ in. N/A N/A 7 N/A 5 N/A N/A N/A N/A in. N/A N/A N/A N/A 0 0 6 6 8 8 NOTE - Concentric terminations are equivalent to 5 ft. of straight pipe and should be included when measuring total pipe length. Refer to 99% Minimum Design Temperature table provided in the current edition of the ASHRAE Handbook-Fundamentals. PolyPro poly-propylene vent pipe is a registered trademark of DuraVent. Innoflue is a registered trademark of Centrotherm Eco Systems. ML95UH / Page

DIMENSIONS - INCHES (MM) - UPFLOW POSITION NOTE - 60C and 60D size units that require air volumes over 800 cfm must have one of the following:. Single side return air and Optional Return Air Base with transition that must accommodate required 0 x 5 x inch (508 x 65 x 5 mm) air filter to maintain proper velocity.. Bottom return air.. Return air from both sides. 4. Bottom and one side return air. See Blower Performance Tables for additional information. Optional Side Return Air Filter Kit is not for use with the Optional Return Air Base. (5) D COMBUSTION INTAKE -/8 (86) -7/8 (7) EXHAUST OUTLET SUPPLY OPENING Flue Condensate Trap Assembly Furnished for external field installation on either side of unit. (See installation instructions for additional information.) 7 (78) OPTIONAL SIDE RETURN FILTER KIT (Either Side) -/4 (60) 5 (65) TOP VIEW A B 9/6 (4) (5) Front Panel 7-/4 (705) 9-7/6 (494) 9/6 (4) OPTIONAL SIDE RETURN FILTER KIT (Either Side) (88) 6-9/6 (67) Left 9 (9) Right -5/8 () (Either Side) ELECTRICAL INLET (Either Side) (5) (Either Side) GAS PIPING INLET (Either Side) CONDENSATE TRAP CONNECTION (Either Side) 6-/ (65) (Either Side) 4-/4 (75) 6 (406) (584) Side Return Air Opening (Either Side) 4 (56) -/ (8) /4 (9) Model No. ML95UH / Page FLOW C Bottom Return Air Opening FRONT VIEW ML95UH045XP4B ML95UH045XP6B ML95UH070XP6B ML95UH090XP6C ML95UH090XP48C ML95UH090XP60C ML95UH0XP48C ML95UH0XP60C /4 (9) 5/8 (6) -/ (597) Bottom Return Air Opening SIDE VIEW A B C D -5/6 (49) in. mm in. mm in. mm in. mm 7-/ 446 6-/8 46 6 406 7-5/8 94 5 9-7/8 505 9-/ 495 9-/8 8 ML95UH5XP60D 4-/ 6 -/8 594 584 9-/4 48 -/4 (8)

DIMENSIONS - INCHES (MM) - HORIZONTAL POSITION LEFT-HAND DISCHARGE 6-/ (65) Bottom -5/8 () Bottom 6-9/6 (67) Top 9 (9) Bottom CONDENSATE TRAP CONNECTION (Bottom) FLOW ELECTRICAL INLET (Top or Bottom) 9/6 (4) 7-/4 (705) COMBUSTION INTAKE (5) Top or Bottom TOP VIEW (88) GAS PIPING INLET (Top or Bottom) (5) Front Panel /4 (9) 7-/4 (705) 9/6 (4) B 9-7/6 (494) SUPPLY OPENING -7/8 (7) D A FLOW -/4 (95) A C -/ (59) RETURN OPENING EXHAUST OUTLET END VIEW -/8 (86) (5) FRONT VIEW RIGHT-HAND DISCHARGE END VIEW CONDENSATE TRAP CONNECTION (Bottom) FLOW 6-/ (65) Bottom -5/8 () Bottom 9 (9) Top 6-9/6 (67) Bottom (5) Top or Bottom 7-/4 (705) ELECTRICAL INLET (Top or Bottom) (5) Front Panel TOP VIEW (88) GAS PIPING INLET (Top or Bottom) EXHAUST OUTLET (5) -/8 (86) 7-/4 (705) -/ (59) RETURN OPENING C -/4 (95) A FLOW A D -7/8 (7) 9-7/6 (494) SUPPLY OPENING B 9/6 (4) END VIEW /4 (9) FRONT VIEW COMBUSTION INTAKE END VIEW 9/6 (4) Model No. ML95UH045XP4B ML95UH045XP6B ML95UH070XP6B ML95UH090XP6C ML95UH090XP48C ML95UH090XP60C ML95UH0XP48C ML95UH0XP60C A B C D in. mm in. mm in. mm in. mm 7-/ 446 6-/8 46 6 406 7-5/8 94 5 9-7/8 505 9-/ 495 9-/8 8 ML95UH5XP60D 4-/ 6 -/8 594 584 9-/4 48 ML95UH / Page

OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) HORIZONTAL (END) FILTER KIT 5/8 (6) 4 /4 (69) -/4 () A 5/8 (6) B RETURN OPENING / (597) 5/8 (6) FLOW Furnace Cabinet Width Catalog Number A B in. mm in. mm B 87L96 8 457 6-/4 45 C 87L97 5 8-/4 476 D 87L98 5 65 -/4 60 5/8 (6) SIDE VIEW FILTER (Furnished) FRONT VIEW CONDENSATE TRAP Optional Return Air Base (Upflow Applications Only - For use with B, C and D cabinets) FURNACE FRONT INDOOR QUALITY CABINET (PCO, Filter Cabinet, etc.) IF BASE IS USED WITHOUT IAQ CABINET, A SINGLE RETURN PLENUM MUST COVER BOTH UNIT AND RETURN BASE OPENINGS -/4 (8) 7-/4 (84) (584) Overall (Maximum) Unit side return air Opening 5-5/8 (4) Minimum (79) Maximum 4 (56) SIDE RETURN OPENINGS (Either Side) -7/6 (570) Overall (Maximum) 7-/ (446) B Width (50W98) (5) C Width (50W99) 4-/ (6) D Width (5W00) OPTIONAL RETURN BASE (584) 6-7/8 (68) SIDE VIEW /4 (9) NOTE- Optional Side Return Air Filter Kits are not for use with Optional Return Air Base. Both the unit return air opening and the base return air opening must be covered by a single plenum or IAQ cabinet. Minimum unit side return air opening dimensions for units requiring 800 cfm or more of air (W x H): x in. (584 x 79 mm). The opening can be cut as needed to accommodate plenum or IAQ cabinet while maintaining dimensions shown. Side return air openings must be cut in the field. There are cutting guides stenciled on the cabinet for the side return air opening. The size of the opening must not extend beyond the markings on the furnace cabinet. To minimize pressure drop, the largest opening height possible, up to 4 in. (56 mm), is preferred. ML95UH / Page 4

DIMENSIONS - INCHES (MM) - FURNACE/COIL COMBINED DIMENSIONS UPFLOW POSITION Model No C5/C7/CX5/CX8 Cased C5 Uncased A B A B C5/CX5 C7 CX8 in. mm in. mm in. mm in. mm C5/CX5-8/4A C5/CX5-8/4B C5/CX5-4A C5/CX5-4B C5/CX5-0A C5/CX5-0B C7-5A C7-5B - - - - - - 6-/ 49 49-/ 57 4-/8 59 47-/8 97 CX8-5A CX8-5B 8-/ 470 5-/ 08 6-/8 46 49-/8 54 - - - - - - CX8-0A 0-/ 5 5-/ 59 - - - - - - - - - - - - C7-A C7-B C5/CX5-0/6A C7-6A C5/CX5-0/6B C7-6B C5/CX5-0/6C C7-6C C5/CX5-6A C5/CX5-6B C7-8A C7-8B CX8-A CX8-B CX8-6A CX8-6B CX8-6C CX8-8A CX8-8B -/ 57 55-/ 40 0-/4 57 5-/4 65 4-/ 6 57-/ 46 -/4 565 55-/4 40 4-/ 6 57-/ 46 -/8 568 55-/8 407 - - - C7-4B CX8-4B 4-/ 6 57-/ 46 - - - - - - - - - - - - C5/CX5-48B C5/CX5-48C - - - C7-4B C7-4C C7-48B C7-48C CX8-4B CX8-4C CX8-44/48B CX8-44/48C 7-/ 699 60-/ 57 6-/4 667 59-/4 505 4-/ 6 57-/ 46 - - - - - - - - - - - - C5/CX5-49C C7-49C CX8-49C 9-/ 749 6-/ 588 8-/ 74 6-/ 56 C5/CX5-50/60C C7-50/60C CX8-50/60C 7-/ 699 60-/ 57 5-7/8 657 58-7/8 495 - - - C7-60D CX8-60D 5-/ 648 58-/ 486 - - - - - - - - - - - - CX5-60C C7-6C CX8-6C -/ 800 64-/ 68 0-5/8 778 6-5/8 66 CX5-60D C7-6D CX8-6D 9-/ 749 6-/ 588 8 7 6 549 A (88) B A B (88) HORIZONTAL POSITION Model A B Number in. mm in. mm CH CH-8A-F -/ 546 54-/ 84 CH-4/0A-F, CH-4B-F, 6-/ 67 59-/ 5 CH-6A-F, CH-6B-F, CH-48C-F, CH-60D-F CH-6C-F, CH-44/48B-F, CH-6D-F -/ 800 64-/ 68 CH-50/60C-F, CH5 CH5-8A-F, CH5-4A-F, CH5-4B-F, CH5-0B-F, CH5-0A-F, CH5-4B-F, CH5-48B-F, CH5-6A-F, CH5-6B-F, CH5-6C-F, CH5-4C-F, CH5-48C-F CH5-5C-F, CH5-60D-F 6-/ 67 59-/ 5 -/ 880 64-/ 68 ML95UH / Page 5

OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) FLUSH-MOUNT VENT TERMINATION KIT 5W (US) or 5W (CANADA) With or -/ in. (5 or 64 mm) PVC pipe Exhaust Intake (Behind Plate) Seal all openings (typical) With in. (76 mm) PVC pipe Exhaust Intake (Behind Plate) -/8 (60) (05) minimum (recommended) (5) PVC pipe (76) PVC pipe NOTE - PVC pipe and fittings are not furnished When required Use and must be field furnished. Field Provided -/ to in. (64 to 5 mm) Coupling -/ (64) PVC pipe MUFFLERS 5Y66 - -inch 6A56 - -inch -Inch - 8-/4 (476) -Inch - 5 (65) 4-/ (4) (Installed Vertically in the Exhaust Pipe) NOTE - Two-inch mufflers do not have reducers at each end. ML95UH / Page 6

OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) CONCENTRIC WALL TERMINATION APPLICATIONS CONCENTRIC ROOF TERMINATION APPLICATIONS EXHAUST OUTSIDE WALL INTAKE EXHAUST (05) Minimum Above Average Snow Accumulation FLASHING (Not Furnished) INTAKE CLAMP (Not Furnished) INTAKE (05) Minimum Above Grade or Average Snow Accumulation CLAMP SHEET METAL STRAP (Clamp and sheet metal strap must be field installed to support the weight of the termination kit.) GRADE ELBOW (Field Supplied) 7M80 / 69M9 / 44W9 inch kits 60L46 / 44W9 inch kits See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. A B / (89) in. kits 4 / (4) in. kits TERMINATION ASSEMBLY (Furnished) 6 / (65) INTAKE 6 (5) EXHAUST Outdoor Exhaust Accelerator included with 7M80/44W9 Cat. No. 7M80 69M9 44W9 (Canada) A B in. mm in. mm /8 848 6 /4 45 9 77 5 / 94 60L46 8 7/8 987 /6 58 44W9 (Canada) 6 /8 98 9 / 495 NOTE Typical illustration for dimensions only. Design may vary depending on kit ordered. WALL ASSEMBLY TERMINATION KIT RING KIT 5F74 inch (5 mm) See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. DIRECT VENT APPLICATION NON-DIRECT VENT APPLICATION NOTE - EXHAUST PIPE SHOWN Kit Contains Enough Parts For Two Installations in. (05 mm) - in. (5 mm) dia. exhaust pipe 0 in. (508 mm) - in. (76 mm) dia. exhaust pipe maximum length without support in. (05 mm) - in. (5 mm) dia. exhaust pipe 0 in. (508 mm) - in. (76 mm) dia. exhaust pipe maximum length without support 8 in. (0 mm) minimum 6 in. (5 mm) maximum NOTE in. (05 mm) minimum height above average snow accumulation (from bottom of vent pipe). NOTE in. (05 mm) minimum height above average snow accumulation (from bottom of vent pipe). ML95UH / Page 7

OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE inch (5 mm) G44 (US) inch (76 mm) 44J40 (US) See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. If Intake and Exhaust Pipe is less than in. (05 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. WALL SUPPORT 8 (0) MIN. Between Ends of Exhaust and Intake Pipe (05) MAX. for (5) Dia. Exhaust 0 (508) MAX. for (76) Dia. Exhaust (05) INTAKE 6 (5) Maximum EXHAUST INTAKE 5 (7) / () FOAM INSULATION (Field Furnished) EXHAUST 8 (0) MIN. (05) Minimum Above Grade or Average Snow Accumulation GRADE 5-/ (40) (05) Minimum Above Grade or Average Snow Accumulation GRADE (05) MAX. for (5) Dia. Exhaust 0 (508) MAX. for (76) Dia. Exhaust WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE inch (5 mm) 0G8 (WTK Canada) inch (76 mm) 8J0 (WTK Canada) See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. If Intake and Exhaust Pipe is less than in. (05 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. WALL SUPPORT INTAKE 6 (5) Maximum (05) MAX. for (5) Dia. Exhaust 0 (508) MAX. for (76) Dia. Exhaust 6 (5) MIN. EXHAUST INTAKE 5 (7) (05) / () FOAM INSULATION (Field Furnished) EXHAUST 6 (5) MIN. (05) Minimum Above Grade or Average Snow Accumulation GRADE (05) MAX. for (5) Dia. Exhaust 0 (508) MAX. for (76) Dia. Exhaust 5-/ (40) (05) Minimum Above Grade or Average Snow Accumulation GRADE ML95UH / Page 8

BLOWER DATA ML95UH045XP4B PERFORMANCE (Less Filter) External Air Volume / Watts at Various Blower Speeds Static Medium- Medium- High Low Pressure High Low in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts 0.00 40 455 90 65 765 95 70 65 0.0 5 445 900 60 765 90 690 55 0.0 5 40 895 50 755 85 680 55 0.0 090 45 870 40 75 80 660 50 0.40 065 405 870 5 75 70 65 45 0.50 00 90 85 5 675 60 605 5 0.60 945 65 780 00 640 50 555 5 0.70 90 50 740 95 585 40 505 0 0.80 790 5 670 75 50 5 455 05 0.90 75 0 575 55 460 0 90 95 ML95UH090XP6C PERFORMANCE (Less Filter) External Air Volume / Watts at Various Blower Speeds Static Medium- Medium- High Low Pressure High Low in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts 0.00 60 75 45 590 090 475 885 85 0.0 65 700 0 580 070 465 890 80 0.0 580 675 05 570 070 455 890 70 0.0 55 60 95 55 060 45 890 60 0.40 480 65 75 55 055 40 885 50 0.50 45 565 0 485 00 40 860 0 0.60 50 55 75 450 005 90 85 0 0.70 60 505 5 45 955 60 785 90 0.80 90 480 00 80 880 5 740 85 0.90 060 45 90 60 795 95 655 50 ML95UH045XP6B PERFORMANCE (Less Filter) External Air Volume / Watts at Various Blower Speeds Static Medium- Medium- High Low Pressure High Low in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts 0.00 605 700 70 590 60 475 00 400 0.0 600 680 55 565 55 465 05 90 0.0 550 645 0 540 50 445 000 80 0.0 480 60 95 50 40 40 975 65 0.40 45 590 80 490 05 45 975 45 0.50 55 565 90 460 085 95 940 5 0.60 0 545 65 45 00 80 900 5 0.70 5 500 0 45 980 55 855 0 0.80 5 480 050 95 90 0 780 80 0.90 05 445 950 60 795 95 700 55 ML95UH090XP48C PERFORMANCE (Less Filter) External Air Volume / Watts at Various Blower Speeds Static Medium- Medium- High Low Pressure High Low in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts 0.00 40 880 895 780 590 645 50 550 0.0 0 850 880 760 585 65 60 545 0.0 060 80 840 75 580 60 60 50 0.0 990 765 805 690 550 585 65 500 0.40 95 750 755 655 50 545 0 470 0.50 80 700 675 60 460 55 85 450 0.60 70 645 60 575 90 480 0 45 0.70 600 65 50 55 00 465 65 90 0.80 455 560 40 500 00 40 05 65 0.90 00 55 05 465 00 90 90 0 ML95UH090XP60C PERFORMANCE (Less Filter) Air Volume / Watts at Different Blower Speeds Single Side Return Air Air volumes in bold require External Bottom Return Air, Side Return Air with Return Air from Optional Return Air Base and field fabricated transition to Static Both Sides or Return Air from Bottom and One Side. accommodate 0 x 5 x in. air filter in order to maintain Pressure proper air velocity. in. w.g. High Medium-High Medium-Low Low High Medium-High Medium-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 445 90 5 000 875 840 495 660 445 55 80 00 785 850 400 665 0.0 40 70 0 985 860 80 500 650 45 5 60 00 775 840 405 655 0.0 70 60 70 960 875 805 55 645 90 0 5 985 790 85 45 645 0.0 90 0 0 95 855 785 545 640 05 70 080 960 805 805 455 640 0.40 00 90 055 900 85 765 560 65 0 40 05 95 775 780 460 60 0.50 095 55 970 865 785 75 50 60 50 5 965 900 745 755 460 60 0.60 00 45 90 850 75 75 495 600 055 70 890 865 695 70 440 605 0.70 960 0 85 85 655 690 455 575 955 45 805 840 640 705 45 590 0.80 845 080 70 785 570 665 90 550 85 095 705 85 565 675 60 565 0.90 75 040 60 755 490 645 05 50 75 065 590 775 470 645 90 540 ML95UH / Page 9

BLOWER DATA ML95UH070XP6B PERFORMANCE (Less Filter) External Air Volume / Watts at Various Blower Speeds Static Medium- Medium- High Low Pressure High Low in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts 0.00 585 685 40 585 095 480 880 80 0.0 560 665 0 565 085 470 885 75 0.0 55 60 00 540 080 460 880 70 0.0 465 590 75 50 065 440 890 60 0.40 40 570 5 490 050 40 875 50 0.50 45 540 95 470 00 400 840 5 0.60 75 50 40 440 975 65 80 5 0.70 95 485 090 40 90 55 780 90 0.80 05 460 995 80 850 5 70 75 0.90 985 40 890 45 770 00 650 55 ML95UH0XP48C PERFORMANCE (Less Filter) External Air Volume / Watts at Various Blower Speeds Static Medium- Medium- High Low Pressure High Low in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts 0.00 000 90 675 765 60 65 85 55 0.0 980 895 650 745 70 60 80 505 0.0 95 855 600 70 400 590 70 485 0.0 875 80 560 680 70 570 60 490 0.40 800 785 490 655 5 545 0 455 0.50 75 70 400 60 95 55 080 45 0.60 60 685 5 585 85 480 00 40 0.70 50 665 90 55 00 45 940 85 0.80 40 60 90 485 985 400 790 65 0.90 45 560 000 40 95 80 75 5 ML95UH0XP60C PERFORMANCE (Less Filter) Air Volume / Watts at Different Blower Speeds Single Side Return Air Air volumes in bold require External Bottom Return Air, Side Return Air with Return Air from Optional Return Air Base and field fabricated transition to Static Both Sides or Return Air from Bottom and One Side. accommodate 0 x 5 x in. air filter in order to maintain Pressure proper air velocity. in. w.g. High Medium-High Medium-Low Low High Medium-High Medium-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 485 55 090 070 85 865 80 660 400 475 00 075 755 870 0 655 0.0 460 475 075 040 80 85 90 650 70 440 090 060 75 850 0 645 0.0 405 445 040 995 790 80 405 650 0 405 060 050 70 85 40 650 0.0 5 75 990 980 760 790 460 65 5 50 040 00 75 85 50 645 0.40 5 55 95 940 740 775 40 60 65 0 975 970 700 85 0 6 0.50 85 0 865 895 680 750 40 65 040 90 90 945 700 790 5 60 0.60 060 70 805 870 60 70 405 60 960 60 845 90 65 770 40 60 0.70 945 5 700 840 605 700 80 590 865 5 750 890 575 70 95 600 0.80 845 0 605 80 505 670 05 570 75 75 590 840 505 70 80 590 0.90 70 50 570 790 470 660 50 540 60 5 490 685 460 685 5 565 ML95UH5XP60D PERFORMANCE (Less Filter) Air Volume / Watts at Different Blower Speeds Single Side Return Air Air volumes in bold require External Bottom Return Air, Side Return Air with Return Air from Optional Return Air Base and field fabricated transition to Static Both Sides or Return Air from Bottom and One Side. accommodate 0 x 5 x in. air filter in order to maintain Pressure proper air velocity. in. w.g. High Medium-High Medium-Low Low High Medium-High Medium-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 595 55 45 05 780 890 65 700 540 500 85 095 75 880 50 700 0.0 570 490 5 095 765 875 70 665 55 480 65 085 75 870 5 675 0.0 440 465 5 075 745 865 95 660 440 445 0 090 75 865 45 675 0.0 40 405 075 060 755 845 65 660 45 400 060 060 75 850 45 670 0.40 55 70 995 005 680 85 70 660 0 45 955 05 685 80 70 660 0.50 095 0 95 960 650 805 5 650 00 0 895 985 60 805 0 650 0.60 995 70 840 95 595 775 0 60 005 85 780 945 605 790 85 65 0.70 900 5 755 905 540 755 70 65 845 5 700 90 50 740 5 60 0.80 740 80 650 875 40 75 90 590 745 85 645 880 450 70 75 595 0.90 580 40 55 840 50 695 45 570 655 60 545 840 80 705 5 575 ML95UH / Page 0

REVISIONS Sections Gas Heat Accessories Description of Change Updated High Pressure Switch Kit catalog numbers for all units. Visit us at www.lennox.com For the latest technical information, www.lennoxpros.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 08 Lennox Industries, Inc.