Four channel video link For low cost video transmission

Similar documents
RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

Single Channel Video Transmit Unit with one Bi-directional Data Channel and two Uni-directional Alarms for a Multimode Fibre Link

T3/E3 Fiber Optic Line Drivers

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

Single Channel Video Receive Unit with two Bi-directional Data Channels and one Bi-directional Alarm Channel for a Multimode Fibre Link

Fiber Optics and Liquid Level Sensors Line Guide

Dual SDI Optical to Electrical Converter

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

AE2200 FTTx Multi-Function Meter

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

IFS Fiber Module Installation & Operation Instructions

4120 Fire Alarm Network Reference

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Dual System with 2x Independent Channels each of :

TruVision Bullet IR Camera Pocket Guide

Fiber Optical Multiplexer

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

Important Safety Notice

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

G4 Pulsed Fiber Laser

IFS SFP Tranceivers User Manual

TruVision Bullet IR Camera Pocket Guide

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

64 Max IR Thermometer

Isolated Thermocouple Module

EOTec 2C32 Installation Guide

Instruction Manual Model L2 RF Switch

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

VPS3 Installation Manual

SIMATRIX NEO Modular Video Matrix

LCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431

IFS Fiber Module Installation & Operation Instructions

G4 Pulsed Fiber Laser

More Precision. indusensor // Linear inductive displacement sensors

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

IF-L/RF Protection Switch

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

C-Bus Four Channel General Input Unit Installation Instructions

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

Stratos Optical HD/SD BNC to "ST" Video Media Converter (Transmitter)

VDS2510 Installation Manual

EPON ONU Optical Transceiver SFF Module

Fibre (TIA) Field Test Specification

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Colour Observation System

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

GPON OLT Optical Transceiver SFP Module RTXM RTXM Features


DS3/STS-1 Protected Repeater System User Manual

Copyright 2017 by Lasermate Group, Inc.. All rights reserved.

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Class 1 laser beam sensor safe for your eyes

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

More Precision. indusensor Linear inductive displacement sensors

Agilent E6000A E6003A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

Infrared Thermometer

ETH1000-MKII. User manual

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

OPX-BOX. Platform Highlights. Software Support. Key Features

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

LCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant

HDCVI PIR Camera User s Manual

FCX-11AB5-3XX-XX 155Mbps BIDI SFP TRANSCEIVER(100Km)

3kW 6kW, QUBE Fiber Lasers

Laser Collimated Beam Sensor

iotdr Series Portable OTDR Test Set iotdr Series OTDR Tester is entirely new portable product released by OPWILL.

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Class 1 laser beam sensor safe for your eyes

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

M210 Multifunction Micro OTDR

Apollo Intelligent Auto Aligning Beam Detector. User Guide

GDC 087R Issue 1 - May Installation and Operation UAS Network/Dropside Interface Unit Model NIU/DIU 7624.

Videomatrix SIMATRIX 648

Product Specification

3500/61E & 3500/67E Temperature Monitor

More Precision. indusensor // Linear inductive displacement sensors

ADDENDUM. xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION GENERAL APPLICATION INFORMATION

Instruments Designed for POF & Fibre Optic Cable Testing

This document is a preview generated by EVS

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus

62 MAX/62 MAX + Infrared Thermometer

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

STATUS ALARM HISTORY ALARM RESET

ENCIRCLED FLUX (EF) TEST SOLUTIONS

Laser Distance Sensor Type M Analog-Output

M700-Series Multifunction OTDR

INTERNATIONAL STANDARD

4-Channel Contact Closure Fiber Link Card System

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

DDT-4691 & DDR ASI / SD-SDI 8 Channel Mux Fibre Optic Link. User Manual. IRT Electronics Pty Ltd

Transcription:

User Manual Four channel video link For low cost video transmission CFO First Mile series consist of fi bre optic modems which provide a high quality and losless video transmission for variety of CCTV applications over multimode fi bre CFO411 video link user manual, 59300058, rev004

Contents CFO411-4 channel video link only... 1 General... 1 Features... 1 CRT411 - Four channel optical transmitter... 2 General... 2 Frame installation... 2 Stand-alone installation... 2 connection and indicator led... 3 Fibre connection... 3 CRR411 - Four channel optical receiver... 4 General... 4 Frame installation... 4 Stand-alone installation... 4 connection and indicator led... 5 Fibre connection... 5 Alarm connection... 5 Technical Specifications... 6 Copyright acknowledgements... 7 WEEE directive... 7 CFO411 video link user manual rev004

CFO411-4 channel video link only CFO411 multimode 4 channel video link for uni-directional video transmission for fixed camera applications V x4 Welcome, and thank you for purchasing Teleste s CFO Products. General The CFO411 is a four channel uni-directional video link. PAL and NTSC video formats are supported to provide a transparent video transmission. Optical transmission is based on class 1M laser operation. The multiplexed data stream of 540 Mb/s enables a full quality and a real-time video transmission in one multimode fi ber up to 1 km typical transmission distance. The primary application is a point-to-point transmission from camera to monitoring centre. In advanced video network systems the CFO411 offers a fl exible way for fi rst mile transfer to the nearest collection point of a larger scale network. All CFO411 units are compatible with all CFO rack systems. Stand-alone options are available with the CMA011 module adapter and separared CPS series mains adapter. As with all CFO platform products these specifi c models do meet all typical EMC as well as other environmental and manufacturing related requirements. Features >> High performance uncompressed zero delay digital video transmission, SNR 60 db typical, 8 bit video sampling >> Four CVBS (PAL/NTSC) video channel >> Uni-directional video transmission on one multimode fi bre up to 1 km >> Same units for rack mount or stand-alone installations >> Mechanically compact and ruggedised >> International EMC and environmental conformance CFO411 video link user manual rev004 1

CRT411 - Four channel optical transmitter 1 2 VIDEO 1 3 CAUTION: THESE OPTICAL UNITS USES CLASS 1M LASER DIODE. DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTI- CAL INSTRUMENTS. APPLICABLE STANDARD IEC60825-2: 2004 General VIDEO 2 The CRT411 is a four channel optical transmitter for uni-directional video transmission in a multimode fi bre. The current consumption is max. 450 ma (+12V DC). VIDEO 3 Frame installation VIDEO 4 The CRR411 module is to be pushed along the guide rails into the installation frame (e.g. CSR216 or 316 series) and secured with the two locking screws. The unit can be freely positioned in any slot in the frame. The empty positions in the frame should be blanked off with cover plates. The supply voltage is to be provided by a CPS384 or CPS390 power supply unit which are installed back of frame. 4 5 INVISIBLE LASER RADIATION CLASS 1M Stand-alone installation The unit can be installed for stand-alone use by using a CMA011 module adapter. The module should be mounted to a vertical surface. The +12 VDC supply voltage is supplied by the means of a separate mains adapter with a regulated output, (e.g. CPS221). CRR411 Optical transmitter 1) Locking screw (2 pcs) 2) input indicator led 3) input connector (BNC female) 4) Optical output (ST) 5) Handle The permitted supply voltage range is 10.5...14 VDC. The current consumption is 450 ma. The permitted operational temperature range is from 10 to +55 C. Rear view RF Pin Signal 1 N/A 2 Ground 3 A - alarm 4 +12 V DC in/out 5 B - alarm 6 N/A 7 N/A 8 Ground 9 N/A 1 2 10.5...14 VDC CONTROL/ALARM Pin information for the D9 connector of the CMA011 module adapter (with CRT411 installed). CMA011 Module Adapter 1) Supply voltage connector, 2) Control / alarm interface connector (D9). 2 CFO4111 video link user manual rev004

connection and indicator led The impedance of the video connection (BNC female) is 75 Ω. The nominal input level is 1 Vpp. Each video connection is equipped with the dual colour VIDEO led on the front panel. See table below for explanation of VIDEO indicator led s lights. Colour Green Yellow Status signal is present, in nominal level, and the unit detects video synchronization pulses No video signal, or the video level is too low VIDEO indicator operation. front view Fibre connection The optical connector is of the type ST. The optical output level is constant and cannot be adjusted. The nominal optical output level is around -4 dbm. The operating wavelenghts is 850 nm. When installing the fi bre optic cable, do not exceed the minimum bending radius when connecting cable to the system. Note! For correct optical operation ensure that all optical connectors are cleaned immediately before mating. Connectors should always be cleaned using high purity alcohol (e.g. methyl or isopropyl alcohol). Dry the surfaces using clean compressed air or other equivalent pressurised gas. The optical connectors on the equipment should always be protected with dustcaps when there is no fi bre inserted. Optical connection meets class 1M laser safety requirements of IEC 60825-2: 2004 and US department of health services 21 CFR 1040.10 and 1040.11 (1990) when operated within the specifi ed temperature, power supply and duty cycle ranges. The optical connector type is ST. INVISIBLE LASER RADIATION CLASS 1M CFO411 video link user manual rev004 3

CRR411 - Four channel optical receiver 1 General 2 VIDEO 1 VIDEO 2 VIDEO 3 3 The CRR411 is a four channel optical receiver for uni-directional video transmission in a multimode fi bre. The current consumption is max. 550 ma (+12V DC). Frame installation The CRR411 module is to be pushed along the guide rails into the installation frame (e.g. CSR216 or 316 series) and secured with the two locking screws. The unit can be freely positioned in any slot in the frame. The empty positions in the frame should be blanked off with cover plates. The supply voltage is to be provided by a CPS384 or CPS390 power supply unit which are installed back of frame. VIDEO 4 Note! The maximum number of CRR411 units in CSR014 / 114 rack installations is 9 pcs and it is recommended that doubled PSU is used in CSR216 / 316 rack installations if number of CRR411 units exceeds 15 pcs. 4 5 CRR411 Optical Receiver 1) Locking screw (2 pcs) 2) output indicator led 3) output connector (BNC female) 4) Optical input (ST) and optical input level indicator led 5) Handle Stand-alone installation The unit can be installed for stand-alone use by using a CMA011 module adapter. The module should be mounted to a vertical surface. The +12 VDC supply voltage is supplied by the means of a separate mains adapter with a regulated output, (e.g. CPS221). The permitted supply voltage range is 10.5...14 VDC. The current consumption is 550 ma. The permitted operational temperature range is from 10 to +55 C. Rear view RF Pin Signal 1 N/A 2 Ground 3 A - alarm 4 +12 V DC in/out 5 B - alarm 6 N/A 7 N/A 8 Ground 9 N/A 1 2 10.5...14 VDC CONTROL/ALARM Pin information for the D9 connector of the CMA011 module adapter (with CRR411 installed). CMA011 Module Adapter 1) Supply voltage connector, 2) Control / alarm interface connector (D9). 4 CFO4111 video link user manual rev004

connection and indicator led The impedance of the video connection (BNC female) is 75 Ω. The nominal output level is 1 Vpp. Each video connection is equipped with the dual colour VIDEO led on the front panel. See table below for explanation of VIDEO indicator led s lights. Colour Green Yellow Status signal is present, in nominal level, and the unit detects video synchronization pulses No video signal, or the video level is too low VIDEO indicator operation. front view Fibre connection The optical connector is of the type ST. The optical input is equipped with the dual color optical level led on the front panel. If the optical input signal is corrupted (e.g. if the fi bre length is too long), too low (i.e. the input level is below -20 dbm), or missing, the optical level led is yellow. If the optical signal is present and otherwise correct, the optical level led is green. The operating wavelenght is 850 nm. When installing the fi bre optic cable, do not exceed the minimum bending radius when connecting cable to the system. Note! For correct optical operation ensure that all optical connectors are cleaned immediately before mating. Connectors should always be cleaned using high purity alcohol (e.g. methyl or isopropyl alcohol). Dry the surfaces using clean compressed air or other equivalent pressurised gas. The optical connectors on the equipment should always be protected with dustcaps when there is no fi bre inserted. The optical connector type is ST. INVISIBLE LASER RADIATION Optical connection meets class 1M laser safety requirements of IEC 60825-2: 2004 and US department of health services 21 CFR 1040.10 and 1040.11 (1990) when operated within the specifi ed temperature, power supply and duty cycle ranges. Alarm connection CLASS 1M B alarm at the rear connector of the unit is type of low open collector output, with the capability of 30 V/10 ma switching. Alarm Description Reason A Not in use B Link status alarm No synchronisation achieved at optical input. Open collector alarms. CFO411 video link user manual rev004 5

Technical Specifications Optical Output/input wavelength 850 nm Spectral width 3 nm Link distance 1 km 62.5/125 μm Bit Rate (forward) 540 Mbps CRT to CRR Number of channels 4 composite Sampling frequency 13.5 MHz Sampling resolution 8 bits Source and load impedance 75 ohm Input and output signal levels 1 Vp-p Input overload level 1.5 Vp-p DC component Insertion gain ± 10 % 1 V Bandwidth 5.5 MHz C/L gain inequality 3 % C/L delay inequality 90 ns Differential gain 1 % Differential phase 1 S/N ratio 60 db unified, weighted General Supply voltage 10.5...14 VDC regulated Current consumption (max) 550 ma CRT411 Current consumption (max) 450 ma CRR411 Dimensions (H x W x D) 3U 5HP 190 mm Weight 0.7 kg Connectors BNC female Optical ST Operating temperature -10...+55 C Storage temperature -30...+70 C Humidity 0...95 % non condensing Emissions EN 50081-1 Susceptability EN 50130-4 Other enviromental upon request Notes Class 1M Laser Product Typical values unless otherwise stated CRT411 multimode fibre up to 1km CRR411 B - Alarm CRT411 850 nm multimode 850 nm fibre CRT401 COW 121 COW 121 1310 nm 1310 nm up to 1 km CRR411 CRR401 6 CFO4111 video link user manual rev004

Copyright acknowledgements Information in this document is subject to change without notice and does not represent a commitment on the part of Teleste Corporation. Copyright Teleste Corporation. All Rights Reserved. No part of this document may be reproduced, transmitted, stored in a retrieval system, or translated into any other language without the express permission of Teleste Corporation. Teleste Corporation Networks P.O. Box 323 FIN-20101 Turku FINLAND www.teleste.com WEEE directive Directive 2002/96/EC of the European Parliament and of the Council on waste electrical and electronic equipment (WEEE) obliges that producers appropriately mark electrical and electronic equipment with the symbol indicating separate collection. This obligation applies to the equipment put on the market in EU after 13 August 2005. Teleste devices which belong to the scope of the directive have been marked with the separate collection symbol shown below. The marking is according to the standard EN 50419. The symbol indicates that the device has to be collected and treated separately from unsorted municipal waste. User manual revision history note: The latest version is always available in pdf-format on our web site: www.teleste.com CFO411 video link user manual rev004 7

8 CFO4111 video link user manual rev004

CFO411 video link user manual rev004 9

www.teleste.com