Single Room Occupancy Hotel Safety & Stabilization Task Force

Similar documents
ORDINANCE NO. Establishing Fire and Life Safety Requirements for Existing Multi-Family Residential Buildings Classified as Group R, Division Occupancy

CITY OF SIMI VALLEY MEMORANDUM

FIRE PREVENTION AND PROTECTION*

AMENDED IN BOARD 07/26/16 ORDINANCE NO [Fire, Housing, Building Codes - Fire Safety Requirements for Existing Buildings]

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

CITY OF PALM BEACH GARDENS ORDINANCE NO. 12, 2002

SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21

First Published in the Wichita Eagle on DELINEATED 10/02/2010 ORDINANCE NO.

Fire Protection Coffee Break Training August 2016

S 2758 S T A T E O F R H O D E I S L A N D

FIRE SAFETY REQUIREMENTS FOR PRE RESIDENTIAL BUILDINGS OF THREE OR MORE STORIES (DOROTHY MAE ORDINANCE - NO. 158,963)

SPRINKLER ORDINANCE Town of Yarmouth, Maine Recodified: 1/15/98 Amended: 4/19/01 Amended: 6/18/15

WHEREAS, a photoelectric smoke alarm, in a smoldering fire, can alert a warning signal faster than a non-photoelectric smoke alarm; and

AGENDA ITEM # 9.1

ORDINANCE AN ORDINANCE AMENDING THE HENDERSONVILLE MUNICIPAL CODE, TITLE 7, CHAPTER 2, FIRE CODE

ORDINANCE NO

ORDINANCE NUMBER

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS.

ORDINANCE NO

Council of the City of York, PA Session 2008 Bill No. Ordinance No. INTRODUCED BY: Genevieve Ray DATE: November 18, 2008

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Pismo Beach, CA Municipal Code. Chapter 8.08 FIRE PREVENTION REGULATIONS

ORDINANCE NO

Agency for Health Care Administration

CARBON MONOXIDE ALARM STANDARDS ACT - ENACTMENT Act of Dec. 18, 2013, P.L. 1229, No. 121 Cl. 35 An Act

Ordinance amending the Building, Housing, Fire, and Administrative Codes to

Chapter 2: Definitions

SPRINKLER PROTECTION OF COMBUSTIBLE CONCEALLED SPACES WITH LESS THAN 6 BETWEEN OPPOSITE FACES IN CAVITY.

ORDINANCE NO. _ THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

~ j~z~_ ~. Kirk Caldwell Mayor

2016 California Building Code Adoption OC amendments Summary Title/Subject Justification/Comments Action

ORDINANCE NO

Ch. 569 FIRE AND SAFETY SERVICES 28 CHAPTER 569. FIRE AND SAFETY SERVICES GENERAL PROVISIONS INTERNAL DISASTER PLAN EVACUATION DRILLS

AUTOMATIC FIRE SPRINKLER SYSTEMS

PRESENTERS OVERVIEW COMMUNITY WORKSHOP OVERVIEW OF THE 2010 EDITION OF THE CALIFORNIA BUILDING STANDARDS CODE AND LOCAL AMENDMENTS

PINETOP FIRE DEPARTMENT TIMBER MESA FIRE AND MEDICAL DISTRICT

[NOTE: Proposed additions to existing code language are highlighted in yellow.]

City of Chilliwack. Bylaw No A bylaw to regulate fire prevention and the protection of life and property

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

MEMORANDUM. TERESA McCLISH, COMMUNITY DEVELOPMENT DIRECTOR

2015 Recommended Building Code with Amendments. The Executive Committee of the Central Iowa Code Consortium does ordain as follows:

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

(House Bill 849) Public Safety Rental Dwelling Units Carbon Monoxide Alarms

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

HIGH-RISE RETROFIT ORDINANCES - NO and NO

Glenwood Springs Fire Protection District Amendments to the 2009 International Fire Code

Agency for Health Care Administration

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rule

GENERAL ASSEMBLY OF NORTH CAROLINA SESSION 2007 SESSION LAW SENATE BILL 1924

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

Residential-based Care Facility R-4 Guideline

Agency for Health Care Administration

ORDINANCE NO, 5907 AN ORDINANCE AMENDING ALBANY MUNICIPAL CODE CHAPTER , UNIFORM FIRE CODE

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

Carbon Monoxide Alarm Update

OFFICE OF THE CITY ATTORNEY ROCKARD J. DELGADILLO REPORT RE:

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector Permit

For additional information regarding R-3.1 residential care facilities please contact (951)

Query: Do water heater installations and replacements require a plumbing license, permit, and inspection in the state of Colorado?

CHAPTER 7 ALTERATIONS LEVEL

The blank report forms are enclosed. If additional blank forms are needed you may contact my office at (210) and ask for Maria Castoreno.

DECLARATORY STATEMENT. THIS CAUSE came on for consideration upon the Petition for Declaratory

Amend Base Code. Amend Base Code. Amend Base Code. Disposition. (Statute, Rule, FBC, Industry) Y/N

Report on First Revision June 2014 NFPA 5000

N.J.A.C. 5: A. NEW JERSEY ADMINISTRATIVE CODE Copyright (c) 2016 by the New Jersey Office of Administrative Law

DECLARATORY STATEMENT. THIS CAUSE came on for consideration upon the Petition for Declaratory

WHEREAS, the City of Albany has adopted a Fire Prevention Regulations in the form of Chapter XI of the Albany Municipal Code; and

January 1, 2014 Mandatory Effective Date

LexisNexis (TM) New Jersey Annotated Statutes

Changes in NFPA

Narrative Reports As Regulated by 780 CMR, Section 903.0

Amended in Board 7/10/12 ORDINANCE NO. 3 Ordinance amending the San Francisco Administrative Code by adding Sections 53.1

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

Fire Drill Requirements Group E Occupancies

Recent Revisions and Proposed Key Changes to Fire Code

ORDINANCE NO. SECTION 1. This ordinance, due to its length and corresponding cost of

M E M O R A N D U M. All Licensed Assisted Living Facilities. Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect

ORDINANCE NUMBER~-07

VILLAGE OF DOWNERS GROVE Report for the Village Council Meeting

Residential-based Care Facility R2.1 Guideline

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

ORDINANCE 2009-_15_ WATER CONSERVATION POLICY

780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDS

CITY OF HEALDSBURG ORDINANCE NO. 1130

Agency for Health Care Administration

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

City of Chilliwack. Bylaw No A bylaw to regulate fire prevention and the protection of life and property

CITY OF TYLER CITY COUNCIL COMMUNICATION

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL

AIRPORT OFFICE BUILDING. Smoke Control System. Testing Procedures Manual. September 10, 2016

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

ANN ARBOR CITY NOTICE ORDINANCE NO. ORD FIRE PREVENTION

DEALING WITH FIRE SAFETY

PROPOSED REGULATION OF THE STATE FIRE MARSHAL. LCB File No. R January 7, 2000

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

ORDINANCE NO. _ THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

CITY OF HEALDSBURG SENIOR CENTER IMPROVEMENT PROJECT

Transcription:

Page 1 of 6 Graphics Version Skip to Content Single Room Occupancy Hotel Safety & Stabilization Task Force sfgov residents business government visitors online serviceshelp Single Room Occupancy (SRO) Hotel Saftey and Stabilization Task Force >> Documents Residential Hotel Sprinkler Ordinance [Requirements for automatic sprinklers in residential hotels.] Ordinance amending the San Francisco Fire Code Section 9001.1.3 and the San Francisco Housing Code Section 904 to extend compliance with requirements regarding installation of automatic sprinkler systems in residential hotels, as defined in the Ordinance, to December 31, 2002 January 31, 2003; providing findings as to local conditions pursuant to the California Health and Safety Code; and making this Ordinance retroactive to June 30, 2002. Note: Additions are single-underline italics Times New Roman; deletions are strikethrough italics Times New Roman. Board amendment additions are double underlined. Board amendment deletions are strikethrough normal. Be it ordained by the People of the City and County of San Francisco: Section 1. Findings. The City and County of San Francisco is unique among communities generally in California with respect to its residential hotels in that, among other things, (1) due to the age of San Francisco itself, many of the City's residential hotels are of a greater average age than those located in other communities in California, (2) due to its relatively limited geographic area and unique topographical conditions, San Francisco has significantly more residential hotels per square mile than found in many other communities in California, and such hotels are typically directly adjacent to other such hotels as well as other types of occupancies, (3) as does San Francisco itself, the City's residential hotels reflect a wide range of construction techniques and materials, styles, and features, and therefore San Francisco is presented with a wide range of potential fire safety risks not necessarily found throughout California generally, and (4) San Francisco's residential hotels are intermingled with the City's residential, commercial, industrial, and other uses to a greater extent than is generally the case in many other communities in California, and this also presents a variety of fire safety risks not necessarily found in other areas of California.

Page 2 of 6 Over the past several years, the City has experienced a near epidemic of residential hotel fires, resulting in significant loss of life, injuries, the loss of many residential units, and significant property damage. The causes of these fires, to the extent such causes have been determined, vary from case to case. However, it appears that smoking and cooking by residents, and either carelessness or malicious behavior by residents, ex-residents and property owners accounts for the majority of the reported fires. The incidence of reported fires in residential hotels appears to be far greater than occurs in residential occupancies of other types within the City. In many cases, the residential hotels subject to fires were not equipped with sprinklers, or were equipped with sprinklers that were inoperable or inadequate to protect human life and property. The Fire Marshal, after investigation of several of these fires, has concluded that the presence of adequate and operational sprinkler systems would likely have significantly mitigated the damages caused by fire. There is a severe shortage of decent, safe, sanitary and affordable rental housing in the City and County of San Francisco and this shortage affects most severely the elderly, the disabled, families, and low-income persons. Many of the elderly, disabled and low-income persons and families reside in residential hotel units. A housing emergency exists within the City and County of San Francisco for its elderly, disabled and low-income households and families, which is exacerbated by the loss of residential hotel units from the rental housing market due to fire. The loss of such residential hotel units affects those persons who are least able to cope with displacement in San Francisco's housing market. Recognizing the above-stated unique fire safety characteristics of San Francisco as presented by the City's residential hotels, requiring the fire protection measures reflected in this ordinance is intended to address the potential fire safety risks pertaining to residential hotels. Further, it is the purpose of this ordinance to benefit the general public by minimizing adverse impact on the housing supply and on displaced families and low income, elderly, and disabled persons resulting from the loss of residential hotel units through fire. California Health and Safety Code Section 17958.5 requires the City to furnish specific reasons to the California Building Standards Commission for changes to the California Fire Code, the California Building Code and/or the Uniform Housing Code, based upon local conditions. Changes to the California Fire Code and California Building Code must be based upon local conditions related to climatic, geologic, or topographical conditions. On July 20, 2001, the Board of Supervisors adopted Ordinance No. 165-01 (File No. 010224) to address the conditions described above. Since that time, the Board of Supervisors has determined that the requirements need to be modified to address additional safety issues and implementation concerns expressed by members of the public and affected property owners. Consequently, the Board of Supervisors finds and determines that the conditions described above continue to constitute a general summary of the most significant local conditions giving rise to the need for and justifying variance from the California Fire Code, California Building Code and Uniform Housing Code. Further, this legislation is more restrictive in part than the California Fire Code, the California Building Code and the Uniform Housing Code, requiring existing buildings to comply with current building standards. The Clerk of the Board of Supervisors is hereby directed to transmit this legislation,

Page 3 of 6 upon its final passage, to the California Building Standards Commission and the State Fire Marshal for filing, pursuant to the applicable provisions of State law. Section 2. Article 90 of the San Francisco Fire Code is hereby amended by amending Section 9001.1.3, to read as follows: Sec. 9001.1.3 [for SF] Local Standards for Existing Group R, Division 1 Occupancies. (a) Sprinklers Required. An automatic sprinkler system, designed in accordance with NFPA 13 (1999 edition), shall be installed throughout the residential occupancy of every residential hotel building existing on October 16, 2001 the effective date of this Section and which is three or more stories in height or contains 20 or more guest rooms, as defined in the California Building Code. "Residential Hotel" for purposes of this Section shall mean each and every hotel for which a Certificate of Use for any residential units has been issued pursuant to San Francisco Administrative Code Chapter 41. (b) Design Criteria. The design criteria for the installation of the sprinkler system shall be approved by the Fire Department and shall comply with NFPA 13 (1999 edition). Those buildings that have installed a sprinkler system prior to August 20, 2001 that complies with a previous NFPA standard shall be exempt from this Ordinance. Where a partial sprinklers system has been previously have been installed in a building subject to this Section, the design criteria for such existing sprinkler system, or any new system may be approved or modified by the Chief of the San Francisco Fire Department or his/her authorized representative. (c) Compliance Date. Residential hotels subject to this Section must submit a building permit application and plans to the Department of Building Inspection and the Fire Department by September 1, 2002, and complete the fire sprinkler installation as required within subsections (a) and (b) by December 31, 2002. come into compliance with this Section by June 30, 2002 January 31, 2003. All buildings governed by this Ordinance which fail to comply with the September 1, 2002 filing deadline shall remain regulated by the original sprinkler installation deadline of June 30, 2002,,and subject to immediate code enforcement action. (d) Property owners who are subject to the requirements of this Section shall be prohibited from relocating tenants for the sole purpose of complying with this Section. Section 3. Chapter 9 of the San Francisco Housing Code is hereby amended by amending Section 904, to read as follows: SEC. 904. AUTOMATIC SPRINKLER SYSTEM. (a) Where Required. In any apartment house or hotel, any compartment or room in the basement containing more than 1,800 square feet of floor area, or any compartment or room in such a building used for storing or using combustible or flammable materials, shall be equipped with an automatic sprinkler system of a type designed and installed according to the provisions of Chapter 9 of the Building Code. Automatic sprinkler systems designed and installed according to the provisions of Chapter 9 of the Building Code shall be furnished and installed in all hotels as required by this Code.

Page 4 of 6 EXCEPTIONS: (1) Any automatic sprinkler system required by this Section to be installed in an existing hotel pursuant to this Code shall not be required to have an on-site water supply. (2) Any automatic sprinkler system required by this Section to be installed in an existing hotel pursuant to this Code may utilize existing standpipes as approved by the Director and the Bureau of Fire Prevention and Public Safety. (3) Any automatic sprinkler system required by this Section to be installed in a maid's closet, or similar area, or a floor containing guest rooms in a hotel shall meet the following criteria: (a) Such system may be connected to a domestic water system, regardless of the number of maids' closets, or similar areas, in the hotel, as long as there is a minimum pressure of 15 p.s.i. at each sprinkler head; (b) only one sprinkler head need be installed in each such maid's closet, or similar area; and (c) no such system need be connected to the building's sprinkler alarm system. (4) Any automatic sprinkler system required by this Section to be installed in an existing hotel pursuant to this Code (a) shall, in the event that such existing hotel is already equipped with a supervised automatic sprinkler system, be connected to such existing other system for purposes of supervision only, or (b) shall, in the event that such existing hotel is not already equipped with a supervised automatic sprinkler system, be connected to a local alarm located at the front desk or other approved location. (b) Domestic Water System. The sprinkler system in an area having less than 1,800 square feet may be connected to a domestic water system if the water supply and pressure conform to the provisions of Chapter 9 of the Building Code. (c) Exceptions. (1) Boiler rooms, central heating rooms and bank vaults are excluded from this Chapter. (2) Compartments or rooms in the basement of apartment houses containing four or less dwelling units, provided that there are no mattresses, upholstered furniture, or loose storage contained therein, are excluded from this Chapter. (d) In existing Group R, Division 1 Occupancies with enclosed stairways in which an approved partial automatic sprinkler system is to be installed to satisfy the requirements of the Housing Code, the design of the system shall be based on all the following additional design criteria: (1) The computations shall be based upon the most remote locations of sprinkler heads. (2) The sprinkler water service size and riser size shall be determined by adding the total number of sprinkler heads on the floor requiring the greatest number of heads, plus one-half of the total number on the floor with the same or next greatest number of heads, plus the total number of all heads in all open stairwells. (3) The maximum water supply required will be that necessary to supply 13 sprinkler heads.

Page 5 of 6 (4) There shall be a minimum pressure of 15 p.s.i. at each sprinkler head and delivery shall be a minimum of 22 g.p.m. from each head. (5) Piping and spacing of sprinkler heads shall be based on ordinary Hazard Schedule of NFPA 13, in accordance with the Building Code. (e) Residential Hotels. An automatic sprinkler system, designed in accordance with NFPA 13 (1999 edition), shall be installed throughout the residential occupancy of every residential hotel building existing on October 16, 2001 the effective date of this Subsection and which is three or more stories in height or contains 20 or more guest rooms, as defined in the California Building Code. "Residential Hotel" for purposes of this Subsection shall mean each and every hotel for which a Certificate of Use for any residential units has been issued pursuant to San Francisco Administrative Code Chapter 41. The design criteria for the installation of the sprinkler system shall be approved by the San Francisco Fire Department and shall comply with NFPA 13 (1999 edition). Those buildings that have installed a sprinkler system prior to August 20, 2001 that complies with a previous NFPA standard shall be exempt from this Ordinance. Where a partial sprinklers system has been previously have been installed in a building subject to this Section, the design criteria for such existing sprinkler system,or any new system, may be approved or modified by the Chief of the San Francisco Fire Department or his/her authorized representative. Property owners who are subject to the requirements of this Subsection shall be prohibited from relocating tenants for the sole purpose of complying with this Subsection. Residential hotels subject to this Subsection must submit a building permit application and plans to the Department of Building Inspection and the Fire Department by September 1, 2002, and complete the fire sprinkler installation as required within subsections (a) and (b) by December 31, 2002. come into compliance with this Subsection by June 30, 2002 January 31, 2003. All buildings governed by this Ordinance which fail to comply with the September 1, 2002 filing deadline shall remain regulated by the original sprinkler installation deadline of June 30, 2002, and subject to immediate code enforcement action. Section 4. This Ordinance shall be retroactive to June 30, 2002. APPROVED AS TO FORM: DENNIS J. HERRERA, City Attorney By: Theodore Lakey Deputy City Attorney EXPLORE Home

Page 6 of 6 About Meetings Documents Homeless Resolution Voucher Policy Contact Us Text Only Options Text size: [S] [M] [L] Color mode: [Default] [High contrast] [Listen] Contact Us Accessibility Policies City and County of San Francisco: SFGOV 2000-09 Nov. 9. 09