CITY OF HEALDSBURG SENIOR CENTER IMPROVEMENT PROJECT
|
|
- Stephanie Greer
- 5 years ago
- Views:
Transcription
1 CITY OF HEALDSBURG MEASURE V SENIOR CENTER IMPROVEMENT PROJECT VICINITY MAP DRAWING INDEX ARCHITECTURAL A-0 COVER SHEET HEALDSBURG SENIOR CENTER SC-1 SENIOR CENTER FLOOR PLAN SC-1.1 SENIOR CENTER DETAILED FLOOR PLAN / CASEWORK SCHEDULE SC-2 SENIOR CENTER EXTERIOR ELEVATIONS SC-3 SENIOR CENTER INTERIOR ELEV. / DETAILS SC-4 SENIOR CENTER BLD'G. SECTIONS / DETAILS SC-5 SENIOR CENTER ROOF PLAN SC-6 ROOF DETAILS SC-6.1 ROOF DETAILS MECHANICAL (HVAC) OWNER / LOCATIONS OWNER: CITY OF HEALDSBURG 401 GROVE STREET HEALDSBURG, CALIFORNIA LOCATION: HEALDSBURG SENIOR CENTER 131 MATHESON STREET HEALDSBURG, CALIFORNIA STATISTICS PROJECT MANAGEMENT ALAMEIDA ARCHITECTURE PROJECT CONSTRUCTION MANAGEMENT 555 S. MAIN STREET, SUITE 2 SEBASTOPOL, CA (707) CITY OF HEALDSBURG MEASURE V MULTI-SITE IMPROVEMENT PROJECT HEALDSBURG SENIOR CENTER M-0.1 MECHANICAL NOTES M0.2 SCHEDULES M-2.1 SENIOR CENTER HVAC FLOOR PLAN M-6.1 DETAILS CALGREEN AND CA TITLE 24 BUILDING TYPE: V-B BASIC ALLOWABLE SQ. FEET = 9,000 S.F. FIRE SPRINKLERS = YES ALLOWABLE WITH SPRINKLER INCREASE = 27,000 ACTUAL SQUARE FEET = 4,828 S.F. NUMBER OF STORIES = 1 OCCUPANCY GROUP = B PARKING REQUIRED = 0 PARKING PROVIDED = 0 HEALDSBURG SENIOR CENTER 131 MATHESON STREET HEALDSBURG, CALIFORNIA CG-1 CG-2 CALGREEN FORMS CALGREEN FORMS T-1 TITLE 24 FORMS T-2 TITLE 24 FORMS RE T L GIS A E TER D D E. R A A RCH L R A C M EI IT E C R DO N D T D C A Exp. 11/30/ GENERAL NOTES ALL WORK CONFORM TO APPLICABLE CODES, REGULATIONS, LAWS AND ORDINANCES AS REQUIRED AND BY THE CODES AND REGULATIONS LISTED IN THESE CONSTRUCTION DOCUMENTS AND MANUALS.. VERIFY ALL DIMENSIONS IN THE FIELD. NOTIFY THE ARCHITECT OF ANY DISCREPANCY AND OBTAIN CLARIFICATION BEFORE PROCEEDING WITH THE AFFECTED WORK. FOLLOW NUMERICAL DIMENSIONS: DO NOT SCALE, USE DATUM POINTS TO START DIMENSION STRING LAYOUT. FLOOR PLAN DIMENSIONS SHOWN ARE TO FACE OF FINISH OR CENTERLINE OF COLUMNS, UNLESS OTHERWISE NOTED. SEE SYMBOLS. BEFORE BEGINNING WORK AT THE SITE, WHERE POSSIBLE AND THROUGHOUT THE COURSE OF WORK, INSPECT AND VERIFY THE LOCATION AND CONDITION OF ITEMS AFFECTED BY THE WORK UNDER THIS CONTRACT AND REPORT DISCREPANCIES TO ARCHITECT BEFORE DOING THE WORK RELATED TO THAT BEING INSPECTED. THE ARCHITECTURAL DRAWINGS SHOW PRINCIPAL AREAS WHERE WORK MUST BE ACCOMPLISHED UNDER THIS CONTRACT. INCIDENTAL WORK MAY ALSO BE NECESSARY IN AREAS NOT SHOWN ON THE ARCHITECTURAL DRAWINGS DUE TO CHANGES AFFECTING EXISTING MECHANICAL, ELECTRICAL PLUMBING OR OTHER SYSTEMS. SUCH INCIDENTAL WORK IS ALSO PART OF THIS CONTRACT. DO NOT DRILL OR CUT EXISTING JOISTS, BEAMS, COLUMNS OR OTHER STRUCTURAL ELEMENTS UNLESS SPECIFICALLY INDICATED. PREPARE, SUBMIT AND RECIEVE APPROVAL OF SLEEVE AND OPENING DRAWINGS BEFORE LOCATING SLEEVES AND OPENINGS IN FIRE-RATED CONSTRUCTION AND BEFORE CUTTING FIRE-RATED CONSTRUCTION. WHERE "MATCH EXISTING" IS INDICATED: NEW CONSTRUCTION OF FINISHES AS APPROPRIATE TO THE NOTE, SHALL MATCH ADJACENT CONSTRUCTION AND FINISHES. 9. FIRE BLOCKING SHALL BE PROVIDED IN ALL CONCEALED SPACES, WALL CAVITIES INCLUDED, ACCORDING TO I.B.C. SECTION FIRE NOTES FIRE ALARM: THE EXISTING FIRE ALARM SYSTEM SHALL BE EXTENDED TO COVER ANY NEW AREAS CREATED/MODIFIED AS A RESULT OF THIS PROJECT. INSTALLATION OF SAID SYSTEM SHALL BE IN ACCORDANCE WITH NFPA-72 (2013 EDITION). THE FIRE ALARM SYSTEM CAPABLE OF SUPERVISING THE NEW OR EXTENDED COMMERCIAL FIRE ALARM SYSTEM INSTALLED AS A SPRINKLER SYSTEM MONITORING ALARM SHALL ALSO PROVIDE NOTIFICATION FOR THE PURPOSE OF INITIATING EMERGENCY ACTION, INCLUDING THOSE SYSTEMS ACTIVATED SOLELY BY FIRE SPRINKLER SYSTEMS, SO THAT OCCUPANTS OF THE BUILDING SHALL BE NOTIFIED AUDIBLY AND VISUALLY WITHIN EACH SUITE OR BUILDING DIVISION. A MINIMUM OF ONE NOTIFICATION APPLIANCE SHALL BE LOCATED IN EACH SUITE OR BUILDING DIVISION IN AN OCCUPIED LOCATION. PLANS ARE NOT REQUIRED FOR 3 DEVICES OR LESS BUT AN INSPECTION OF THE MODIFIED ALARM SYSTEM IS REQUIRED. CFC 901.4, CFC 907.2, CFC CITY ORDINANCE 1130, SEC FIRE RESISTIVE ROOFING: THE ROOF ASSEMBLIES HAVING A MINIMUM CLASS B RATING SHALL BE MAINTAIN ON STRUCTURES. CBC 1505 FIRE EXTINGUISHERS: FIRE EXTINGUISHERS WITH A MINIMUM 4A-10BC RATING SHALL BE INSTALLED AT INTERVALS NOT TO EXCEED 75 FEET. EXTINGUISHERS SHALL BE SERVICED WITHIN THE LAST YEAR BY A LICENSED FIRM AND BE MOUNTED ON THE WALL AT CONSPICUOUS LOCATIONS. CFC 906, T19-CH 3 ARTICLE 5 FIRE INSPECTION: A FIRE/SAFETY INSPECTION SHALL BE DONE ON ALL WORK IDENTIFIED ON THIS MEMO BY THE FIRE DEPARTMENT BEFORE FINAL. CFC CHAPTER ECOPY APPLICABLE CODES 2013 BUILDING STANDARDS ADMINISTRATIVE CODE, PART 1, TITLE 24 C.C.R CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 C.C.R. (2012 INTERNATIONAL BUILDING CODE AND 2013 CALIFORNIA AMENDMENTS) 2013 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R. (2011 NATIONAL ELECTRICAL CODE AND 2013 CALIFORNIA AMENDMENTS) 2013 CALIFORNIA MECHANICAL CODE (CMC) PART 4, TITLE 24 C.C.R. (2012 UNIFORM MECHANICAL CODE AND 2013 CALIFORNIA AMENDMENTS) 2013 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R. (2012 UNIFORM PLUMBING CODE AND 2013 CALIFORNIA AMENDMENTS) 2013 CALIFORNIA ENERGY CODE (CEC), PART 6, TITLE 24 C.C.R CALIFORNIA FIRE CODE, PART 9, TITLE 24 C.C.R. (2012 INTERNATIONAL FIRE CODE AND 2013 CALIFORNIA AMENDMENTS) 2013 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN), PART 11, TITLE 24 C.C.R CALIFORNIA REFERENCED STANDARDS, PART 12, TITLE 24 C.C.R. TITLE 19 C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS. PARTIAL LIST OF APPLICABLE STANDARDS NFPA 10 PORTABLE FIRE EXTINGUISHERS 2009 EDITION NFP A 13 AUTOMATIC SPRINKLER SYSTEMS 2013 EDITION NFPA 14 STANDPIPE SYSTEMS (CA AMENDED) 2013 EDITION NFP A 17 A WET CHEMICAL SYSTEMS 2013 EDITION NFP A 20 STATIONARY PUMPS 2013 EDITION NFPA 24 PRIVATE FIRE MAINS (CA AMENDED) 2010 EDITION NFPA 72 NATIONAL FIRE ALARM CODE (CA AMENDED) 2013 EDITION NFP A 80 FIRE DOOR AND OTHER OPENING PROTECTIVES 2013EDITION NFPA 110 EMERGENCY AND STANDBY POWER SYSTEMS 2013 EDITION NFP A 2001 CLEAN AGENT FIRE EXTINGUISHING SYSTEMS 2012 EDITION REFERENCE CODE SECTION FOR NFPA STANDARDS CBC (SFM) CHAPTER 35. SEE CHAPTER 35 FOR STATE OF CALIFORNIA AMENDMENTS TO NFP A STANDARDS. COMPLIANCE WITH THE CFC CHAPTER 14, FIRE SAFETY DURING CONSTRUCTION, DEMOLITION AND CBC CHAPTER 33, SAFETY DURING CONSTRUCTION WILL BE ENFORCED AMERICAN WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES APPLICABLE SAFETY STANDARDS: REFERENCES HEREIN TO "CAL/OSHA" SHALL MEAN STATE OF CALIFORNIA, DEPARTMENT OF INDUSTRIAL RELATIONS, CONSTRUCTION SAFETY ORDERS, AS AMENDED TO DATE, AND ALL CHANGE AND AMENDMENTS THERETO ARCHITECT: ALAMEIDA ARCHITECTURE 555 SOUTH MAIN STREET, SUITE 2 SEBASTOPOL, CALIFORNIA (707) FAX (707) CONSULTING ENGINEER: MECHANICAL ENGINEER: CLIMATE MECHANICAL 2914 NEVILE LANE MEDFORD, OREGON PROJECT DESCRIPTION SCOPE INCLUDES: DIRECTORY 1. THE REPLACEMENT OF HVAC UNITS ROOFING PRESERVATION AND ISOLATED RE-ROOFING AT SENIOR CENTER. 2. KITCHEN IMPROVEMENTS AT SENIOR CENTER. Project number Date Drawn by Checked by Scale ST COVER SHEET A TE A - 0 O F L CA IFO NO. DESCRIPTION DATE 1. ISSUED FOR COUNTY HEALTH DEPT REVIEW 1/12/16 A I RN 1/12/16 D.R.A. D.R.A. N.T.S
2 ECOPY
3 ECOPY
4 ECOPY
5 EC OP Y
6 ECOPY
7 ECOPY
8 EC OP Y
9 EC OP Y
10 EC OP Y
11 EC OP Y SEPARATE BUILDING PERMIT MEASURE V PROJECT SEPARATE BUILDING PERMIT MEASURE V PROJECT SEPARATE BUILDING PERMIT MEASURE V PROJECT SEPARATE BUILDING PERMIT MEASURE V PROJECT SEPARATE BUILDING PERMIT MEASURE V PROJECT SEPARATE BUILDING PERMIT MEASURE V PROJECT SEPARATE BUILDING PERMIT MEASURE V PROJECT
12 ECOPY
13 EC OP Y
14 EC OP Y
15 ECOPY
16 EC OP Y
17 ECOPY
Large Family Daycare Guideline
Moreno Valley Fire Department Fire Prevention Bureau Large Family Daycare Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: April 10, 2017 Large Family Daycare Guideline Purpose
More informationMoreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline
Moreno Valley Fire Department Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: May 8, 2017 Alarm & Signaling Systems PURPOSE Fire alarm and signaling systems are designed to
More informationPRESENTERS OVERVIEW COMMUNITY WORKSHOP OVERVIEW OF THE 2010 EDITION OF THE CALIFORNIA BUILDING STANDARDS CODE AND LOCAL AMENDMENTS
COMMUNITY WORKSHOP OVERVIEW OF THE 2010 EDITION OF THE CALIFORNIA BUILDING STANDARDS CODE AND LOCAL AMENDMENTS Prepared By PRESENTERS Truong Huynh, Building and Safety Bureau David Zinnen, Fire Prevention
More informationSECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents
SECTION 01410 PART I - GENERAL 1.01 SECTION INCLUDES A. Relationship between Code, Ordinances, Standards and Contract Documents B. Applicable Codes, Laws and Ordinances C. Project Inspections D. Office
More informationSANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)
FIRE DEPARTMENT SANTA CLARA COUNTY 14700 Winchester Blvd., Los Gatos, CA. 95032-1818 (408) 378-4010 (408) 378-9342 (fax) www.sccfd.org STANDARD DETAILS & SPECIFICATIONS Spec No C-4 Rev. Date 03/10/10 SUBJECT:
More informationCITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU TENANT IMPROVEMENT GROUP A FIRE PLAN REVIEW CHECKLIST
INFORMATION CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU TENANT IMPROVEMENT GROUP A FIRE PLAN REVIEW CHECKLIST DATE: PROJECT NO.: EXPIRATION DATE: STATUS: PROJECT ADDRESS:
More informationFor additional information regarding R-3.1 residential care facilities please contact (951)
Riverside County Fire Department Fire/Life Safety Inspection Division Riverside Office: 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4823 Fax (951) 955-4886 Palm Desert Office: 77-933 Las
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD LICENSED CARE FACILITIES SCOPE: This standard provides requirements for licensed care facilities known as for the Elderly with seven
More informationRiverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)
Riverside County Fire Department Office of the Fire Marshal 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4777 Fax (951) 955-4886 Guideline Title: Residentially Based Care Facilities Group
More informationFIRE PREVENTION STANDARDS
DATE: 04/11/02 APPROVED: NUMBER: FP0-010 REVISED: FIRE PREVENTION STANDARDS TITLE: Large Family Day Cares (9-14 kids) PURPOSE: The purpose of this standard is to acquaint the applicant with the applicable
More informationAUTOMATIC FIRE SPRINKLER SYSTEMS
MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE AUTOMATIC FIRE SPRINKLER SYSTEMS These guidelines are to be followed when a business, facility or organization installs an automatic fire sprinkler system
More informationResidential Based Care Facility Guidelines
Moreno Valley Fire Department Fire Prevention Bureau Residential Based Care Facility Guidelines Approved and Authorized By: Randall Metz, Fire Marshal Issued: January 1, 2011 Residential Based Care Facilities
More informationFIRE & LIFE SAFTEY STANDARD
Title: Effective Date: 01/01/14 Revised Date: 1/1/14 Code References: Title 16, Chapter 16.16 of the Roseville Municipal Code, NFPA 72 Note: This standard is a summary of Fire Department clarifications
More informationResidential-based Care Facility R-4 Guideline
Moreno Valley Fire Department Fire Prevention Bureau Residential-based Care Facility R-4 Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: April 7, 2017 Residential-based Care
More informationInternational Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures
International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures Please note this is not an all-inclusive list. The type and complexity of your project
More informationThe Cannabis Industry: Fire Department Requirements
The Cannabis Industry: Fire Department Requirements RVFD Standard 4.1 Rio Vista Fire Department 350 Main St. Rio Vista, CA. 94571 By: Jeff Armstrong, Fire Chief Updated December 2018 1 The purpose of this
More informationCITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST
CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST DATE: PROJECT NO.: EXPIRATION DATE: STATUS: INFORMATION PROJECT ADDRESS:
More informationSACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET
SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET 1 SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT
More informationFOLD EXIT REQUIREMENTS MAX.TRAVEL DISTANCE ALLOWED: (TABLE ) MAX. COMMON PATH TRAVEL: (CBC ) MAX. DEAD ENDS: (TABLE 1018.
1 2 3 4 5 6 7 8 9 10 E D C B A N1808 A A B A.8 A A 13' - 0" 13' - 0" A.4 B A.8 28' - 6" 1' - 3" 26' - 0" 1' - 3" Level 1_Code 1 1/4" = 1'-0" Level 2_Code 2 1/4" = 1'-0" 1 1.6 2.2 2.7 1' - 3" 14' - 0" 15'
More informationHIGH-RISE RETROFIT ORDINANCES - NO and NO
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC 91.8604 Effective: 9-06-90 DOCUMENT NO. P/BC 2002-054 Revised: 4-15-03 Previously Issued As: MGD 88 HIGH-RISE RETROFIT ORDINANCES - NO.
More informationAmerican Fire Sprinkler Association. An Introduction to the IBC and IFC
American Fire Sprinkler Association Presents An Introduction to the IBC and IFC October 13, 2005 Speaker Roland Huggins, P.E. Vice President of Engineering and Technical Services American Fire Sprinkler
More informationOXNARD FIRE DEPARTMENT 360 West Second Street Oxnard, CA (805) Fax (805)
OXNARD FIRE DEPARTMENT 360 West Second Street Oxnard, CA 93030 (805) 385-7722 Fax (805) 385-8009 REQUIREMENTS FIRE HYDRANT STANDARDS Fire hydrants and required access roads shall be provided prior to and
More informationSPRINKLER PROTECTION OF COMBUSTIBLE CONCEALLED SPACES WITH LESS THAN 6 BETWEEN OPPOSITE FACES IN CAVITY.
STATE OF LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS OFFICE OF STATE FIRE MARSHAL CODE ENFORCEMENT AND BUILDING SAFETY 8181 INDEPENDENCE BOULEVARD, BATON ROUGE, LA 70806 800-256-5452 225-925-4920
More informationFIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES
Established 1949 FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES The following are guidelines for new development. Any submitted plans must comply with these guidelines,
More informationRancho Cucamonga Fire Protection District Prevention Bureau Standard
Rancho Cucamonga Fire Protection District Prevention Bureau Standard Title: Fire Alarm and Monitoring Systems Standard # 9-3 Effective: May 2002 Number of Pages: 7 Updated: December 2016 for consistency
More informationM E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment
M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Services and Fire Protection Equipment Linda MacKay DATE: November 10, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter Ballot Final Results The
More information2016 California Building Code Adoption OC amendments Summary Title/Subject Justification/Comments Action
OC Ordinance 7-1-12 2016 Code 2013 Code 2016 Adoption OC amendments Summary Title/Subject Justification/Comments Action Adoption of the, International Building Code, California Residential Code, California
More informationBrighton Area Fire Authority
615 W. Grand River Ave. Brighton, MI 48116 o: 810-229-6640 f: 810-229-1619 January 14, 2019 Fire Alarm Contractors RE: Fire Alarm Credential & Submittal Requirements To Whom It May Concern: The following
More informationFIRE PREVENTION AND PROTECTION*
Chapter 30 (Replaced old ordinance September10, 2012) FIRE PREVENTION AND PROTECTION* * Cross References: Buildings and building regulations, ch. 14; environment, ch. 26; manufactured homes and trailers,
More informationRetain. Retain. Retain. Board Advisory. Board Advisory. Retain. Disposition. (Statute, Rule, FBC, Industry)
Florida Specific Amendment Code Reference NFPA 101 Anytime a reference is made to NFPA 1 or NFPA 101 within this Code, it shall be 1.1.1.1 the Florida specific version of NFPA 1 and NFPA 101. The Florida
More informationHCD DSA OSHPD 1 2 1/AC AC SS SS/CC
CALIFORNIA BUILDING CODE MATRIX ADOPTION TABLE CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency
More informationTHIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS.
THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS. IF YOU RECEIVED A NOTICE BY MAIL AND YOU DO NOT CURRENTLY HAVE A FIRE ALARM INSTALLED IN YOUR BUILDING, YOU MAY DISREGARD THE NOTICE. Dear Building
More informationM E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot
M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Service and Fire Protection Equipment Gregory Harrington, P.E., Staff Liaison DATE: October 1, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter
More informationFire Department Fire Prevention Inspection Services. HIGH RISE STRUCTURE Fire Inspection Program
HIGH RISE STRUCTURE Fire Inspection Program Meeting Agenda Fire Prevention Mission High Rise Fire Inspection Program Question and Answer 2 Fire Chief Bertral Washington 3 Our Mission Deputy Fire Marshal
More informationRiverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)
Riverside County Fire Department Office of the Fire Marshal 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4777 Fax (951) 955-4886 Technical Policy Title: Plant Processing and Extraction
More informationPERFORMANCE COMPLIANCE METHODS
CHAPTER 13 PERFORMANCE COMPLIANCE METHODS SECTION 1301 GENERAL 1301.1 Scope. The provisions of this chapter shall apply to the alteration, repair, addition and change of occupancy of existing structures,
More informationMULTI-LEVEL & COVERED BOOTH CONDITIONS
MULTI-LEVEL & COVERED BOOTH CONDITIONS Covered Booth Definition To place something over or upon an exhibit or portion of an exhibit (e.g., roof, ceiling, tenting, lattice, fabric, plastic) to cover the
More informationCOMPLIANCE ALTERNATIVES
CHAPTER 12 COMPLIANCE ALTERNATIVES SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter are intended to maintain or increase the current degree of public safety, health, and general welfare
More informationUC Irvine Environmental Health & Safety TITLE: FIRE WATCH AND OUT OF SERVICE NOTIFICATION
SECTION: UC Irvine Environmental Health & Safety TITLE: FIRE WATCH AND OUT OF SERVICE NOTIFICATION INITIATOR: DALE SAUNDERS REVISION DATE: September 2015 1. Program Description 2. Scope 3. Definitions
More informationThe following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):
The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101): 1.1.1 Title. NFPA 101, Life Safety Code, shall be known as the Life Safety Code, is cited as such, and shall
More informationCHRISTMAS TREE LOT INFORMATION & REQUIREMENTS
CHRISTMAS TREE LOT INFORMATION & REQUIREMENTS Applications must be submitted to the Business License Division prior to November 30 th. All required departments must sign off prior to the business start
More informationOCFEC Fire Marshal Summary Report
OCFEC Fire Marshal Summary Report Fire Marshal report (Correction Notices received on 6/1/2018) OC FAIR & EVENT CENTER Maintenance Restrooms 1. CCR Title 19 Section 3.28 Plans and Specifications : Submit
More informationPERFORMANCE COMPLIANCE METHODS
CHAPTER 13 PERFORMANCE COMPLIANCE METHODS SECTION 1301 GENERAL 1301.1 Scope. The provisions of this chapter shall apply to the alteration, repair, addition and change of occupancy of existing structures,
More informationSingle Room Occupancy Hotel Safety & Stabilization Task Force
Page 1 of 6 Graphics Version Skip to Content Single Room Occupancy Hotel Safety & Stabilization Task Force sfgov residents business government visitors online serviceshelp Single Room Occupancy (SRO) Hotel
More informationDEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL
DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL RULES AND REGULATIONS CONCERNING 8 CCR 1507-57 BUILDING AND FIRE CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR LIMITED GAMING
More informationH BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION
STATE OF LOUISIANA Department of Public Safety and Corrections Office of State Fire Marshal Code Enforcement and Building Safety 8181 Independence Boulevard Baton Rouge, Louisiana 70806 225-925-4920 H
More informationFire Alarm, Water Flow Alarm & Signaling Systems
Orange County Fire Authority Community Risk Reduction 1 Fire Authority Road, Building A, Irvine, CA 92602 www.ocfa.org 714-573-6100 Fire Alarm, Water Flow Alarm & Signaling Systems Guideline D-03 Serving
More informationAPPLICATION FOR Large Family Day Care Permit
PLANNING SERVICES DEPARTMENT 411 Main Street (530) 879-6800 P.O. Box 3420 Chico, CA 95927 Application No. APPLICATION FOR Large Family Day Care Permit Applicant Information Applicant Daytime Phone Street
More informationFIRE PROTECTION KEY DESIGN CONCEPTS IN HEALTHCARE FACILITIES Scott Twele, Aman Shah Steven Dannaway. AIA Healthcare Group
FIRE PROTECTION KEY DESIGN CONCEPTS IN HEALTHCARE FACILITIES Scott Twele, Aman Shah Steven Dannaway AIA Healthcare Group Introductions Presenters Coffman Engineers Scott M. Twele, P.E. Operations Manager,
More informationPhotovoltaic (Solar) Array Installation Guide
Building & Safety Division Community Development Department 7351 Rosanna Street, Gilroy, CA 95020 Phone: 408 846-0451 Fax: 408 846-0429 Visit us: www.cityofgilroy.org Photovoltaic (Solar) Array Installation
More informationCITY OF SIMI VALLEY MEMORANDUM
CITY OF SIMI VALLEY MEMORANDUM AGENDA ITEM NO. Consent (10) November 14, 2016 TO: FROM: City Council Department of Environmental Services SUBJECT: ADOPTION OF A RESOLUTION TO RATIFY VENTURA COUNTY FIRE
More informationCarbon Dioxide Enrichment Systems
Orange County Fire Authority Community Risk Reduction 1 Fire Authority Road, Building A, Irvine, CA. 92602 www.ocfa.org 714-573-6100 Carbon Dioxide Enrichment Systems Guideline G-17 Serving the Cities
More informationClark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV (702) FAX (702)
Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV 89118 (702) 455-7316 FAX (702) 455-7347 Ronald L. Lynn Director/Building & Fire Official Samuel D. Palmer, PE.,
More informationFIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011
HCFMO Harris County Fire Marshal M.S. Montgomery Fire Marshal FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011 EFFECTIVE JANUARY 1, 2007 These guidelines
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD
July 2017 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD SPECIAL EVENT PUBLIC ASSEMBLY PURPOSE This standard is applicable to any public event, exhibit space, booth, festival or any other similar
More informationPismo Beach, CA Municipal Code. Chapter 8.08 FIRE PREVENTION REGULATIONS
Pismo Beach, CA Municipal Code 8.08.010 Amendments; California Fire Code. Chapter 8.08 FIRE PREVENTION REGULATIONS The California Fire Code adopted in Section 8.04.010 is modified, amended and/or supplemented
More informationFire Protection Coffee Break Training August 2016
Fire Protection Coffee Break Training August 2016 Agenda Introduction - Phelan NFPA 13 versus NFPA 13R systems for Residential Occupancies - Homa NFPA 72 Record of Completion - Homa Questions and Answers
More informationCOMPLIANCE ALTERNATIVES
CHAPTER 12 COMPLIANCE ALTERNATIVES SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter are intended to maintain or increase the current degree of public safety, health, and general welfare
More informationSTATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT
STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT The interaction of fire protection systems can be extremely complex. The detection of a fire in a building by an automatic device
More informationChapter 4: Fire Protection Systems
Chapter 4: Fire Protection Systems Automatic Extinguishing Systems (Fire Sprinklers) One of the most important aspects of a storage warehouse inspection is ensuring that the automatic extinguishing system
More informationCalifornia Fire Code (CFC) Part III contains requirements. Building and Equipment Design Features PART. Chapters 5 through 19
PART 3 Building and Equipment Design Features Chapters 5 through 19 Chapter 5 Fire Service Features No changes addressed Chapter 6 Building Services and Systems Chapter 7 Fire-Resistance-Rated Construction
More informationHealth Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE
Health Chapter 420-5-22 ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE CHAPTER 420-5-22 SUBMISSION OF PLANS AND SPECIFICATIONS FOR HEALTH CARE FACILITIES TABLE OF
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS Address: Permit #: Inspector: Date Inspected: Status: Inspector: Date Inspected: Status: A-Approved;
More informationFire Drill Requirements Group E Occupancies
Fire Drill Requirements Group E Occupancies Section 1303.3.3.2 Fire Drills 5. Fire Alarm Drill Records - A record of all required fire drills shall be kept by the person in charge of the occupancy and
More informationRecommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region
Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region The following sections, paragraphs, and sentences of the 2015 International Existing
More informationAgency for Health Care Administration
Page 1 of 34 ST - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Statute or Rule Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0001 - OTHER
More informationCLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau
CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 Permit Type: 105.7.14 Control Number: A.0 Effective Date: 9/14/11 TITLE:
More informationNFPA 72 Code Changes vs 2013
NFPA 72 Code Changes - 2010 vs 2013 AFAA-NE Westborough, MA February 7, 2018 Richard Roux NFPA 72 National Fire Alarm and Signaling Code Overview and 2013 Changes NFPA 72 1993 Edition Aug 20, 1993 1996
More informationTOM BURNS, PLANNING DIRECTOR
~~ 0 173 COUNTY OF SANTA CRUZ August 4,2005 PLANNING DEPARTMENT 701 OCEAN STREET, qth FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 TOM BURNS, PLANNING DIRECTOR Agenda:
More informationJanuary 1, 2014 Mandatory Effective Date
2013 Kentucky Building Code Highlights Winnie Blythe, Technical Advisor Dept. of Housing, Buildings, and Construction winnie.blythe@ky.gov www.dhbc.ky.gov 502-573-0373 January 1, 2014 Mandatory Effective
More informationTo provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD STANDARD #F-003 EFFECTIVE 06-03-2009 PURPOSE To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES 2007 CBC/CFC (R-3.1)
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: This Checklist outlines
More informationFire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY
Fire Department HEADQUARTERS 4410 Cathedral Oaks Road Santa Barbara, CA 93110-1042 (805) 681-5500 FAX: (805) 681-5563 Michael W. Dyer Fire Chief County Fire Warden Eric Peterson Deputy Fire Chief CODE
More information2010 FIRE CODE OF NEW YORK STATE
2010 FIRE CODE OF NEW YORK STATE CHAPTER 14 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION SECTION 1401 GENERAL 1401.1 Scope. This chapter shall apply to structures in the course of construction, alteration,
More informationCITY of MODESTO 14 JAN IS AD 38
1 of 5 Btl.ARD OF SUPFRVISORS CITY of MODESTO 14 JAN IS AD 38 Fire Prevention Bureau I o 1 o Tenth Street Suite 3 2 PO. Box 642 ModeJto, CA 95353 29l57 I-5553 29I49I-5969 Fax Hearing and Speech Impaired
More informationNarrative Reports As Regulated by 780 CMR, Section 903.0
EXHIBIT 20 Narrative Reports As Regulated by 780 CMR, Section 903.0 903.1.1 - FIRE PROTECTION CONSTRUCTION DOCUMENTS a. Basis (methodology) of design for the protection of the occupancy and hazard for
More informationBUILDING, FIRE, AND LIFE SAFETY CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR HEALTH FACILITIES LICENSED BY THE STATE OF COLORADO
DEPARTMENT OF PUBLIC SAFETY Division of Fire Prevention and Control BUILDING, FIRE, AND LIFE SAFETY CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR HEALTH FACILITIES LICENSED BY THE STATE OF COLORADO
More informationFIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY
FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY PLAN REVIEWS SITE PLANS: 1) Access to buildings (Volume V NC Building Code sections 602.6.1
More informationORDINANCE NO NOW, THEREFORE, BE IT ENACTED BY THE CITY COUNCIL OF THE CITY OF FAIRBANKS, ALASKA, as follows:
Introduced by: Mayor Eberhart Introduced: June 6, 2016 ORDINANCE NO. 6017 AN ORDINANCE TO AMEND FGC CHAPTER 30, ARTICLE II INTERNATIONAL FIRE CODE, BY ADOPTING THE 2015 INTERNATIONAL FIRE CODE WITH LOCAL
More informationCITY OF PASADENA FIRE DEPARTMENT
Page 1 of 8 CITY OF PASADENA FIRE DEPARTMENT INSTALLATION OF COMMERCIAL SPRINKLERS (Revised 12/10/2014) SCOPE: This standard applies to the design and installation of automatic fire sprinkler systems in
More informationEL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD Installation of Residential Fire Sprinkler Systems STANDARD #C-002 EFFECTIVE 03-19-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain
More informationBold items are particular to the City of Euless
EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 8/2004 Fire Chief Lee Koontz Fire Marshal Paul Smith EFD-FMO 3-1 2003 International Fire & Building Code as Amended NFPA Standards
More informationConstruction and Development Guide
Construction and Development Guide **Based on the 2014 Indiana Fire Prevention Code and relevant NFPA Codes and Standards ** Copyright 2018 Clay Fire CRRD 1 P a g e Table of Contents Map of Jurisdiction...
More informationDesign & Construction Standards, Revised January
PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of The University of Texas at Austin for the design and construction of standpipe systems to include combination standpipe
More informationFull Service Central Station Fire Alarm Listing Evaluation
Full Service Central Station Fire Alarm Listing Evaluation Listing Evaluation A UL Listing project includes: 1. Evaluating the central station facility for compliance with UL 827, Central-Station Alarm
More informationD. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:
PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of Sam Houston State University for the design and construction of standpipe systems to include combination standpipe
More informationI. INTRODUCTION Codes, Rules, Laws, & Requirements
I. INTRODUCTION 1.03 Codes, Rules, Laws, & Requirements A. Buildings and sites are to be designed in conformance to the applicable requirements of the following: 1. The Texas Engineering Practice Act and
More informationREVISION RECORD FOR THE STATE OF CALIFORNIA ERRATA
REVISION RECORD FOR THE STATE OF CALIFORNIA ERRATA January 1, 2017 2016 Title 24, Part 9, California Fire Code General Information: 1. The date of these errata is for identification purposes only. See
More informationPG&E VACAVILLE CRITICAL OPERATIONS CENTER BUILDING B4 GRADING & UNDERGROUND UTILITY PACKAGE RESPONSE TO PUBLIC WORKS-2 COMMENTS
PG&E VACAVILLE CRITICAL OPERATIONS CENTER BUILDING B4 GRADING & UNDERGROUND UTILITY PACKAGE RESPONSE TO PUBLIC WORKS-2 COMMENTS NOVEMBER 01, 2016 CONSULTANTS Civil Engineer BKF Engineers 1646 N. California
More informationFIRE APPARATUS ACCESS AND WATER SUPPLY GUIDELINE
City of Conroe Fire Department Fire Marshal s Office 300 W. Davis 1 st Floor Conroe, Texas 77301 T: (936) 522-3080 F: (936) 522-3079 firecodes@cityofconroe.org FIRE APPARATUS ACCESS AND WATER SUPPLY GUIDELINE
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST FIRE AND LIFE SAFETY SYSTEMS FOR STRUCTURES FIVE OR MORE STORIES IN HEIGHT AND LESS THAN 75 FEET IN HEIGHT FROM THE POINT
More informationOxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)
Oxnard Fire Department 360 W. Second Street Oxnard, CA 93030 (805) 385-7722 Fax (805) 385-8009 FIVE YEAR CERTIFICATION REPORT Service and maintenance report for automatic fire extinguishing systems, including
More informationResidential Care Facilities Requirements
Development Services Department Building Division 311 Vernon Street Roseville, California 95678-2649 Residential Care Facilities Requirements SUBMITTAL REQUIREMENTS: Note: These requirements are in addition
More informationCOMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE
COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE SUPERVISION OF AUTOMATIC FIRE SPRINKLER SYSTEMS SUPERVISION OF ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS FIRE ALARM AND DETECTION SYSTEMS The Fire Alarm
More informationORDINANCE NO
ORDINANCE NO. 2016-14 AN ORDINANCE AMENDING THE CODE OF ORDINANCES, CITY OF BOERNE, TEXAS, BY AMENDING CHAPTER 5 - BUILDINGS AND BUILDING REGULATIONS, ARTICLE VIII, LIFE & SAFETY CODE, SECTION 5-236; AND
More informationThe blank report forms are enclosed. If additional blank forms are needed you may contact my office at (210) and ask for Maria Castoreno.
San Antonio Independent School District 1702 N. Alamo Street, Suite 307 San Antonio, Texas 78215-1213 Telephone (210) 554-2420 Fax (210) 271-3330 Office of Construction Services TO: FROM: All Principals
More informationPERFORMANCE COMPLIANCE METHODS
CHAPTER 13 PERFORMANCE COMPLIANCE METHODS SECTION 1301 GENERAL 1301.1 Scope. The provisions of this chapter ((shall)) apply to the alteration, repair, addition and change of occupancy of existing structures,
More informationOklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:
Oklahoma 310:451-1-3. Adopted references The Board of Health hereby incorporates by reference the International Code Council (ICC) 2006 (IBC) Edition International Building Code; the 2007 Edition Standard
More informationA. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:
SECTION 21 13 13 WET-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More information4/13/2015. Everything a firefighter wants to tell a design professional or building code official, in one hour.
Everything a firefighter wants to tell a design professional or building code official, in one hour. 1 2 3 1 4 The job of the fire department is to put the wet stuff on the red stuff. 5 Job #1. of the
More information