Item/clause/Page no. Description as per tender. To be read as

Similar documents
Contents. Preface. Chapter 2 Faults, types and effects The development of simple distribution systems Faults-types and their effects 7

Table-1: Clarifications and modification in tender specifications based on Pre-bid meeting discussion

DC POWER DISTRIBUTION BOARD

EMEX 110 and EMEL. EMEX 110 and EMEL. 110, 50 and 24 volt AC/DC Central Battery Systems. EMEX 110 and EMEL

MANUFACTURER OF LT PANELS

SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD.

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

The last date of submission of responses has been extended up to 14: 00 hrs on 20/07/2018.

RETROFIT CONTROLLER. Retrofit Energy Controller Any Make PIU/ PMS/ IPMS

Taking Over-cum-A/T Document For Redeployed NSN BTS Sites

2 X 1996 Wartsila 18V mw Each 50hz HFO Generator Sets

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

Protection and Power Management, PPM-3 Display and push-button functions Alarm handling Log list Failure mode and effect analysis

HINDUSTAN PETROLEUM CORPORATION LIMITED MUMBAI REFINERY DHT PROJECT ENGINEERING DESIGN BASIS ELECTRICAL

38-SDMS-04 REV. 0 SPECIFICATION FOR ANNUNCIATOR SYSTEMS FOR PRIMARY DISTRIBUTION SUBSTATION

PNG POWER Ltd REQUEST FOR TENDER

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

ENGINE GENERATORS AND ACCESSORIES

DIGITIAL PROTECTION COUPLER

TYPE APPROVAL CERTIFICATE

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts

Digital Control Systems & Remote Communications Options

Application, Installation, Operation & Maintenance Manual

1 NOS. 25mm x 4 mm thick with PVC sleeving e) 1Set, RYB, indicating lamps & CT

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

KATALOGE. Trading of Electrical Switchgear, Lightings, Machineries & Construction Materials. Jamar Trading Co. W.L.L.

Date of Start and downloading the tender 12 sep 2018

Item Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22

CENTRAL BOARD OF SECONDARY EDUCATION SHIKSHA KENDRA, 2, COMMUNITY CENTRE, PREET VIHAR, DELHI

TYPE APPROVAL CERTIFICATE

Annexure - 1. Detectors: Fire Alarm Control Panel :

TYPE APPROVAL CERTIFICATE

HVAC System Indoor Climate Control

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

CIRCUIT BREAKER FAIL PROTECTION

MODULAR TRACTION SUBSTATIONS CITY ELECTRIC TRANSPORT

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Moulded case circuit brakers

Fire control panel detect 3004 plus and accessories

Product Guide Low Voltage Switchboard & Switchgear

MAZAGON DOCK SHIPBUILDERS LIMITED

Products and Portfolio 01 Relay Panels Control Panels Special Panels

Compact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Symmetra MW Modbus Data Points

FireNET Plus Wiring Instructions

TECHNICAL SPECIFICATION FOR. 11 kv 25 KA INDOOR SWITCHGEAR INTEGRATED WITH ASSOCIATED CONTROL AND RELAY PANELS AND CONTROL DESK FOR REMOTE OPERATION

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Fire and Smoke Control Systems

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

Guide Specification Model CTG Automatic Transfer Switch

APC BC300 Series 40kW 208/450/480V User Guide

Queries raised by the representatives. 4 Sl. No.( iv) 31 Refer Sl. No. 2 It should be Windows 10 professional as it is the latest one

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

Utility Battery Chargers DC Power Systems Custom Design


Scope of Work and Other Terms & Conditions

new new Industrial plugs and sockets

Drexan Energy Systems Inc.

B. Section Transfer Switches: Automatic transfer switch.

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

Tender Document. MR 193/ Design, Supply & Commission New Control Panel for Ruston 16RK270 Generator

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

Family of motor protection

Smoke Vent Control Panel PCB4 V4 Installation Manual

Indian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi , Ph. No.

Loadstar AC/DC Systems

Well Come To Access Control System & Access Engineers & Consultants

IEEE Transformer Committee PC Distribution Transformer Monitoring - User

Generator Paralleling Controller, GPC-3 Hydro Start and stop sequences, water level control

Temperature Control Systems

Event Detection System (EDS)

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

GPS 140 NEC Requirements for Generators. Professional Development Seminar Series NEC Requirements for Generators

TECHNICAL SPECIFICATION FOR FIRE DETECTION & ALARM SYSTEM INCLUDING FIRE EXTINGUISHERS

TAITA TAVETA UNIVERSITY P.O.BOX , VOI, KENYA Tel: TENDER NO: TTU/T/01A/

NATIONAL TRAINING BOARD (ELECTRICIAN) REGULATIONS 2008 BR 54/2008 NATIONAL OCCUPATIONAL CERTIFICATION ACT :38

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

Distributed Generation (greater than 10kW) Connecting to Vector s electricity network

M2500 Engine Controller Installation Manual

21-light Remote Annunciator. Owner s Manual

Guide To Troubleshooting INEFFICIENT COOLING FANS

Gas ventilation monitoring and control system

The CAB & DAB Air Curtains

Technical Manual

Time Extension: Tender submission deadline is extended up to 12:00 Hrs. of

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

FDF Foam Pump Controllers Features

Analog Annunciator Unit SACO 16 A3. Product Guide

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

SOLAR POWER PLANT AUTOMATIO

Spectron LSN (Life Safety Network) Suggested Specifications

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0

INSTALLATION INSTRUCTIONS

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Transcription:

Date- 02.11.2012 Amendment-2 Work - Tender for SITC of HT/LT substation equipments installation and allied electrical works for lecture theatre complex, FCI campus, University of Allahabad, Allahabad. Tender no.:- RITES/CO/B&A/EED/ALD- Uni/Substation/E-3 Sr. no. Item/clause/Page no. Description as per tender. To be read as 1 BOQ.Item. No.25, outgoings Busbar no.-1 and busbar no-4, pg. 022 and 23 Main LT panel Type of protection releases for 630 Amp. TPN MCCBs (outgoing) on bus bar-1 & bus bar-4 side. Required with microprocessor based release with O/L, S/C and E/F Protection. 2. Technical Specification Cl.no.-4.6.7.2 pg.no.-109 GI earth bus bars of 50 mmx6 mm two runs shall be provided for the LT panel for full length of the panel and connected to the frame work. Provisions shall be made for connections from this earth bar to the main earthing bar on both sides of L.T. Panel. Follow standard and acceptable norms as per CPWD specifications Transformers 3 BOQ. Item no.43, pg. 52 Tap changer range +10 % to - 10 % or +5% to -15 %. Tap changer range +5% to -15 %. 4 Technical specification, Clause II( 15), pg. no. 101 The transformer construction & galvanizing of various parts. It should be as per relevant Indian Standards. HT Panel 5 BOQ item no. 25 (II), Synchronising panel Pg. 23,24,25 and 26 Auto as well as manual synchronising with load sharing, AMF logic, load management, protection and interlocking, load balancing complete for following input conditions ( PLC CONTROL PANEL)--------- Auto as well as manual synchronising and load sharing panel, AMF logic, load management, protection and interlocking, load balancing complete for following input conditions (MODULAR CONTROLLER PANEL)---------Details as per annexure A ( 04 pages)

Amendment no. 2 (Annexure "A") Dated 02.11.2012 Work - Tender for SITC of HT/LT substation equipments installation and allied electrical works for lecture theatre complex, FCI campus, University of Allahabad, Allahabad. Tender no.:- RITES/CO/B&A/EED/ALD- Uni/Substation/E-3 SCHEDULE OF QUANTITY ITEM RATE TENDER S. NO. DESCRIPTION OF ITEMS UNIT QTY QUOTED RATE Rate (Rs.) Amount (Rs.) In Figures (Rs.) In Words (Rs) IN FIGURES (Rs) (C) 25 (II) MAIN DISTRIBUTION BOARDS AUTO / MANUAL SYNCHRONIZING & LOAD SHARING PANEL WITH AMF LOGIC, LOAD MANAGEMENT, PROTECTION AND INTERLOCKING, LOAD BALANCING COMPLETE FOR FOLLOWING INPUT CONDITIONS: (MODULAR CONTROLLER PANEL): DG SETS: MAINS: 2 Nos, 1250 KVA TRANSFORMER (SYNCHRONIZING BETWEEN DG SETS ONLY NOT WITH GRID SUPPLY)

i MAJOR CONTROL EQUIPMENTS: a. DG SYNCHRONIZING & CONTROL MODULE " DEIF-242" with DEIF Module - IOM-220 DEIF Module: 4 SETS b. TRANSFORMER FEEDER PLC CONTROLLER MODULE with AMF Sensing & protection of transformer feeder -DEIF Make AGC-245-2 Sets c. Master Trip Relay d. All required necessary relays, Conactors, Contact Blocks with interconnections / wiring to make the panel fully functional & operative a per AMF, synchronizing,load sharing & management complete in all respect in a panel form accomodating all equipments and accessories etc in 2mm thick CRCA sheet steel enclosure. ii Miscellaneous: a. The panel shall be complete in all respect to identify signals, compare, activate command as per requirements fed in data sheet to for AMF, Auto Synchronizing, Master & slave selection, Auto Load sharing & management and shall include all necessary & essential accessories / equipments, required power and signal cabling between Synchrinizing Panel, DG Sets and LT Panels, the cost of required software, essential equipments / tools / instruments required during operation. iii INDICATIONS: 4 Nos, 12 windows anunciation panel for required Indications other than in DEIF Control Module.

4 Nos Set -ON 4 Nos Load on DG Set 2 Nos Load on Mains Supply 1 No DC Control Supply Healthy 1 No, Industrial Type Hooter 24V DC 1 No MIMIC with LED lights for visual display Any other indication required as per standard practice. iv GENERAL ACCESSORIES: All essential accessories & components required to make the panel perfect and operational but not limited to following: Operating Push Buttons Audio Alarms for faults / failure Solo/Parallel sel. Switches Control Relays & Auxilary Contactors Contact Blocks. 1 No for each DG Sets (4 Nos), 24V, 10A DC stabilized Power Supply with Battery Charger 230V AC, 0-15A, Trickle & Boost static Charger for 24V, DG Starting battries. DC 0-30V Voltmeter shall be provided. Required Power Supply & UPS Unit for Contorls Required MCBs / MCCBs Any other accessories / components essentally required to make system perfect in order. v PROTECTIONS:

All essential protections to be included with required relays, sensors, activating switches, including indications on panel for engine, alternator and Panels. Some are indicated below :for each DG Set: a. Engine overheat b. High water Temperature. c. Low lube oil pressure. d. Over Speed. e. Low Fuel oil level. f. Cooling water Flow failure. g. DC control supply failure. h. Reverse Power i. Phase Reversal j. Any other important & essential as per standard practice vi SEQUENCE OF OPERATION: a For Autostart, Auto Syncronizing, Auto Load Sharing, Load Management : DG-1 / 2 / 3 / 4 : Sequence shall be programmed as per load conditions being utilised by the user so that the system works efficiently and smoothly as desired. vii GENERAL: a. Neutral contactor of all the DG sets shall be controlled through PLC such that only one contactor is on at a time in sync mode. In manual mode the neutral contactors shall also be interlocked.

b. The cost of panel shall include all communication & power cables between the Mains Panel / Synchronizing panel / DG Sets, communication card, grafix software package, door operated lights, space heaters with thermostats, 150mm exhaust fans with air filter and other item required to complete the system shall be part of the quoted rate. c. All wiring shall be included to wire to the breakers provided in LT panels (Mains) / LT Panel (Emergency) / DG Sets / Synchronizing Panel complete for fool proof and flaw less operation. AMF, AUTO SYNCHRONIZING, LOAD SHARING & MANAGEMENT PANEL AS ABOVE No 1