Environmental Product Declaration

Similar documents
Environmental Product Declaration

RP13290 Impressa XS95 platinum (CH) 650 Edition: 01/06/09

INTEX INDUSTRIES (XIAMEN) CO.,LTD. Declaration of Composition Acc. to Directive 2002/96/EC (WEEE)

RP12927 Impressa X90 black (CH) 642 Edition: 01/06/09

Operating Manual. English. Refrigerators for chemicals KRC 50 KRC 180

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Airworthiness Directive

INSTALLATION INSTRUCTIONS

RP13362 Impressa XS90 OT black (CH) 656 Edition: 01/06/09

PRODUCT NUMBER: Rd40 Aluminium Canister AXP3

Premier External TD. Installation Manual INS352-3

Technical Datasheet. Suction Controllers, Flow Meters & Accessories

3M Benchtop Air Ionizer 963E. User s Guide

Role of CE Marking in the Placing on the Market of Electronic Components

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

TTV 4500 / TTV 4500 HP / TTV 7000

1592P01. for liquids in piping DN

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

INSTRUCTIONS MANUAL INDUSTRIAL WALL FAN (20, 26, 30 ) WITH REMOTE CONTROL

CP-200 S&T. CP Warewash Pump Instruction & Operation Manual Speed & Time , Rev1.0, , Page 1 of 8

Vacuum generators. Festo core product range Covers 80% of your automation tasks

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

PIPETMAN M Exclusive Charging Stand!

INSTALLATION GUIDE. Isodrive Revision V1.1. HOME APPLIANCES

FT2080 Fire terminal (Touch) Mounting Installation

Rhino SD2/XD2 ARW Air Circuit Module for 125-mm Frames

ROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH

SFE 2311BK. EN Desktop Fan. Copyright 2017, Fast ČR, a.s

PRODUCT NUMBER: RD40 Plastic Filters AXP3 XL

Important Safety Notice

Introducing Hermaphroditic Blade and Receptacle Connector

FDCL221 Line separator

Owner & Operator s Manual. Table of Contents

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

TECHNICAL SPECIFICATION

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Technical Sheet. Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1

KM300 Carbon Monoxide Detection System Installation Manual

Welcome Guide ES... support.arctic.ac/lf120

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

Compfitt Group- A strong partner for the industry

Instructions. Certifications CH Chrome SS Stainless Steel. Single Handle, Industrial Style, Pull-Down Kitchen Faucet.

Compfitt Group- A strong partner for the industry

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1

Diaphragm pumps. Operation Manual. Models: 2019C-02 (230V / 50Hz) 2019B-01 (115V / 60Hz) 2019C-50 (230V / 50Hz)

GB User and maintenance manual

Air. Pressure. Motion. nnnnnnnn

PORTABLE DEW POINT MONITOR

FT2080 Fire terminal (Touch) Mounting Installation

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

E C O L O G I C A L C O O L E R S INTELLIGENT PLUS PARTS CATALOGUE

MMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated

+ + + EUGEN WOERNER. Level Switch KFA-A. Two switching points for level monitoring max.

Frost Protection Thermostat

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

CS-1800 OWNERS MANUAL

Health & Safety and Installation guide

NMÉ NATIONAL TECHNICAL ASSESSMENT

Lighting Equipment Guide

PD10. Serial Plates with Side Ports for ISO Valves. Technical Features. Technical Data. Functional Description. Page 1. Size 10 (D05) p max

TECHNICAL SHEET. Indoor luminaire FIRA-03-1xT8 AS Didactic. About the product. FIRA AS, FIRA AS Didactic

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

CP-200 Push Button. CP Warewash Pump Instruction & Operation Manual Push Button , Rev1.0,

Instructions for the fan motor control system, SILVER C

Mounting Instructions Adapter for ventilation duct BWP-143A-SS, Stainless Steel version

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

HR Powder Feed Hopper

Operating Instructions!

Materials Handling and Intralogistics. Industrial Trucks. In accordance with the Directive Equipment for potentially explosive atmospheres (ATEX)

Portable Electric Patio Heater User's manual

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

PRODUCT NUMBER: Viking V1 Multiple-Position Earmuff

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

For calls outside the UK Telephone or Fax TETRA PAK PUMPS FREEPHONE: Centrifugal Pump Single Shaft Seal Type ALC-1

Vacuum generators VADM/VADMI

General information and installation instructions for Metal Detectors

Cost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A

Health & Safety and Installation guide

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Use and Maintenance Manual. WPA-E-N/Ex. II 2 G c Ex e II T3. ATEX marking: Explosion proof stand fans WPA-E-N/Ex

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Spare parts list ( ) Spare parts list PUZZI 100

SonoSelect and SonoSafe energy meters

AIR HANDLING UNITS MANDÍK

CS-1600 OWNERS MANUAL

Parts Catalogue. /

Leakage detection sensor

HYTEK ATEX APPROVED BUND ALARM

Beck. The differential pressure transmitter for air

OSC... INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

2kw Remote Control Electric Fire. User and Installation Instructions

Wiring Duct Product Selection Guide

PORTABLE HYDRANT PN10 1A; 2A; 1B; 2B; 1C; 2C TYPES

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Water separators MS-LWS, MS series

Diaphragm pump 4 - headed

Transcription:

Environmental Product Declaration Product Type of equipment / Product No. A6E60200837 GMC21 AFTB Airflow test bench GMC21 Product Type of equipment / Product No. GMC21 AFTB Airflow test bench GMC21: A6E60200837 Designation GMC21 AFTB Banc Airflow GMC21 Product line, product range GMC21 Smoke Detector Process control Siemens S.A.S. Division BUILDING TECHNOLOGIES (BT) 15-17 Avenue Morane Saulnier 78140 Vélizy-Villacoublay / France Management System since by ISO 9001 (Quality) 22.03.2017 AFNOR OHSAS 18001 (OH&S) 07.03.2017 AFNOR ISO 14001 (Environment) 07.03.2017 AFNOR Environmentally compatible product design Product responsibility of Siemens covers the entire product life cycle. Siemens already assesses, avoids and minimizes the environmental impact of its products with respect to production, procurement, sales, use, services and disposal during the product and process planning phases by complying with Siemens EP Standard (former SN 36350) "Specifications on Environmentally Compatible Product and System Design". Product use Risk of fire Typical energy consumption Maintenance Fire protection according to Fire load 4kWh/a Maximum value in nominal mode On notice On notice 30MJ Packaging 4-LDPE Plastic bag 11g HdPE; bentonite Desiccant bag 46g Cardboard; wood Main packaging 10 000g Restricted Page 1/6

Notes on disposal Reusable / Take-back Materials Plastics Total weight of device 8 131g The total weight of a device may deviate from the total of the weights of all individual components due to rounding. PBT Shut-off valve 50g PC Plastic block 866g EPDM Seals 4g PPS Plastic tube 35g EPDM Tip of quick release horizontal 4g Metals Nickel-plated brass, NBR Push-in T Connector 62g Bronze, Brass Silencer 10g EN AW 6082[AlSi1MgMn] Bracket for clamp lock 437g EN AW 6082 [AlSi1MgMn] Flowmeter bracket 319g EN AW 6082 [AlSi1MgMn] Faucet support 152g EN AW 6082 [AlSi1MgMn] Airflow bench plate 1 732g EN AW-6082 [AlSi1MgMn] Airflow bench foot 1 376g Steel stainless Hexagon cap socket screw 182g Steel; galvanized Pan Head Screw 19g Steel; galvanized Washer 22g Steel; galvanized Hex nut 19g Steel; galvanized Adapter 93g Al Filter Hausing 603g Steel; zinc plated Quick release horizontal 678g Others Brass, Nickel plated, POM, NBR, Alloy steel Push-in fitting 156g Anodized aluminium, FKM Thermal Mass Flow Meter 325g Anodized aluminium, FKM Thermal Mass Flow Controller 238g PVC cable Power Analog Cable 82g PVC cable Power Digital Cable 179g PVC cable Power Supply 386g Epoxy ester Filter 4g Plastique, Tresse inox, Acier zingué FLEJIC5 105g Restricted Page 2/6

PCBAs (Printed Circuit Board assembled) Special components (part of the assembled PCB) *Variant parts list [g] Total weight of device Shut-off valve Plastic block Seals Plastic tube Tip of quick release horizontal A6E60200837 8 131 50 866 4 35 3 Push-in T Connector Silencer Bracket for clamp lock Flowmeter bracket Faucet support Airflow bench plate 61 10 437 319 152 1 732 Restricted Page 3/6

Airflow bench foot Hexagon cap socket screw Pan Head Screw Washer Hex nut Adapter Filter Hausing Quick release horizontal 1 376 181 18 21 18 92 603 678 Push-in fitting Thermal Mass Flow Meter Thermal Mass Flow Controller Power Analog Cable Power Digital Cable Power Supply Filter FLEJIC5 156 325 238 82 178 386 4 105 Fire load [MJ] 30 Typical energy consumption [kwh/a] 4 Special components (part of the [pcs] Restricted Page 4/6

Packaging Plastic bag Desiccant bag Main packaging [g] 11 46 10 000 Disposal The device is classified as waste electronic equipment in terms of the European Directive 2012/19/EU (WEEE) and must not be disposed of as unsorted municipal waste. Regarding disposal, use the systems setup for collecting electronic waste. Observe all local and applicable laws. Comments EU-directive 2011/65/EU (RoHS) The device does not contain substances in concentrations and applications banned under the EU RoHS Directive. Regulation (EC) No. 1907/2006 (REACH) To the best of our knowledge and according to the information of our suppliers the above mentioned device and its packaging contain no substances of the candidate list according to Article 59 (1, 10) of the regulation (EC) No. 1907/2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) in concentrations above 0.1 % w/w. (Status according to the creation date of this document.) The device is halogen-free with exception of: Power Analog Cable; Power Digital Cable; Power Supply Legal Disclaimer: This declaration is for information purpose only. This Environmental Product Declaration does not constitute a guarantee of the composition of a product, neither does it guarantee that the product will retain a particular composition for a particular period. Restricted Page 5/6

Siemens S.A.S. therefore does not assume liability for any error or for any consequences which may arise from the use of this information to the maximum extent under the law. Please contact your local Siemens branch office to get further information on environmental aspects and disposal. 18.06.2018 Restricted Page 6/6