USER INSTRUCTIONS Fir Road, Mishawaka, IN Phone: (574) Fax: (574)

Similar documents
USER INSTRUCTIONS Fir Road, Mishawaka, IN Phone: (574) Fax: (574) Page 1 of 15

INSTALLATION INSTRUCTIONS

RV Winterization Guide Prepare Your Camper for the Cold

Winterizing Your Motorhome

SERVICE PROCEDURES. SERVICE TYPE: JPMC Winterization ACCESS: See Order Instructions for Lockbox Code SCHEDULING PROCEDURES: ON-SITE PROCEDURES:

The WateRx Plant. Features/Benefits. Applications (for municipal water usage) Great water throughout the home or office. Automatic weekly backwash

WARRANTY POLICY & RECOMMENDED MAINTENANCE

The Classeq under counter range

ProPet Washer. I-1020 Page 1 of 6 Rev. D /15/11

WS1 Greensand Installation & Start Up Guide

Is Sewer Gas Giving Your Customers the Wrong Impression?

FAUCET REPAIR RV PARTS & ACCESSORIES RV PARTS & ACCESSORIES FAUCET STEMS FAUCET ESCUTCHEONS

INSTALLATION AND OPERATION INSTRUCTIONS LC-D SERIES COFFEE CONCENTRATE BREWER WITH DIGITAL ELECTRONIC CONTROL CENTER

AUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL

MICRO CLEANER. OPERATOR MANUAL Advance MODEL /10 Rev E Document Number

Installation & Operators Manual

MINIMUM CONSTRUCTION STANDARDS AND SPECIFICATIONS CHECKLIST

Installation & Operators Manual

BEFORE OPERATING THE MACHINE: WARNING

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

Sinks A clog, low water pressure a nonfunctioning sink can practically shut

AUTOTROL 360 MANUAL & 361 SEMI-AUTOMATIC FILTER VALVES SERVICE MANUAL

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

Installation, Operation, and Maintenance Manual RTE14S & RTE14S-2. For the Taco Bell "Rethermalizer" Model Numbers

Table of Contents. List of Figures

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

IMPORTANT SAFETY INFORMATION READ ALL...

1 P a g e. G4 Counter Top OPERATION MANUAL

American Dish Service

Installation Manual for M-G014 & M-G015

HOT TANK INSTALLATION AND OPERATING INSTRUCTIONS. Model #: 5000

Installation and Owners manual

Clean Water Made Easy

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

The Classeq pass Through range

Liberty-Classic. Operator s Manual

Owners Manual for the Rainmaster Water Recycling System

HOT TANK INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

Scale Stopper Plus Installation & Start-Up Guide

Autotrol Performa FA Valve

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions

Care and Use Manual Tank Series Appliances

Ozone System Maintenance Instructions

Sidekick Pro Rinse Assist Installation and Operation Guide

Welcome! Today s topic: Small Home Repairs. November 14, 2015

MAG-MIFAB. Trap Priming Systems and Valves BENEFITS

Owner's Manual. Whole House Water Softener with Triton Electronic Control Valve. or call

American Dish Service

KITCHEN FAUCET COS-KF222C

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Installation & Operators Manual. The Classeq Pass Through Range

Fully Automatic Water Softeners

PolyMax H2-24 Dutch Bucket System

This guide is intended to assist Heartland Owners in understanding the operation and routine maintenance of their water systems.

MODEL FW-2000 OPERATION MANUAL

Fully Automatic Water Softeners

Fleck 2510 SXT Catalox Installation & Start Up Guide

Installation. Please keep this manual for future reference.

CleanSpray System Operation

WL380 QUICK START GUIDE

Installation Instructions

START-UP AND CLEAN-UP PROCEDURES

Installation, Operation, and Troubleshooting Manual. Bill Wallace by Wallace Marine Services, Inc.

Installation Instructions AS-WH Whole House Water Filter

SHURFLO BLASTER II MARINE WASHDOWN PUMP PRODUCT TECHNICAL DATA SHEET

Whole House Descaler Installation Instructions

PRISM/CONCORD/LEPRECHAUN/ORION WINTERIZING

SPIKA NG ICE MAKER MAINTENANCE

A FRESH APPROACH to Sustainable Design

1 P a g e MODEL G5CT COUNTER TOP OPERATION MANUAL

Plugging Home Drains to Prevent Sewage Backup

OWNER S MANUAL IMPORTANT: READ OWNER S MANUAL CAREFULLY

Nordic Hotel Dispenser Model CHD22 /CHD30 Installation and Service Manual

K4600 Assembly Directions

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES

2015 Animal Care Catalog central systems. wall mount. portables

GULFSTREAM PLASTICS LTD.

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

DUOBATHE BATHING SYSTEM

PrimePour TM Operation Manual

ROUGH IN VALVES. Installation Manual MB439 - SV9INC.219 EU MB440 - SV9INC.220 EU MB441 - SV9INC.221 EU MB442 - SV9INC.222 EU MB443 - SV9INC.

CFX-27 GALLON PORTABLE EXTRACTOR. Owner s Manual CFX 1/22/2010

PRE INSTALLATION PROCEDURES

INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841

Watch Water USA Green Chemical Technology

13 GALLON Extractor MODEL NO

Waimea ShowerSpa MODEL #1034

CHAPTER VI BUILDING PLUMBING

ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES

Frequently Asked Questions

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

DISTRICT OF COLDSTREAM and GREATER VERNON WATER NOTICE TO RESIDENTS

CHAPTER 5 Water, Plumbing, and Waste

MARSHALLTOWN MEDICAL AND SURGICAL CENTER ENVIRONMENTAL SERVICES. SUBJECT: Room Cleaning Occupied Room (All Areas) PROCEDURE NO: 032

HydroCycle Vertical Aeroponic Systems

Installation and Operation Manual MG-304. Please read this manual carefully before use.

Transcription:

Congratulations on purchasing an RV equipped with the most advanced water management system available today! Be sure to read all Caution and User Instructions on the Nautilus Panel and in your Owner's Manual before performing any operation using the Nautilus Panel System. NEVER depress check valve on "CITY WATER CONNECTION" with pressure in the line. It will cause irreparable damage to the check valve function.

The Nautilus P1 Panel System will allow you to perform the following functions: 1. Power fill your fresh water tank for remote or dry camping 2. Use your pump to supply water to fixtures from fresh water tank 3. Use your pump to siphon fill or sanitize your fresh water tank from a bucket 4. Connect to city water at the camping site to supply water to fixtures 5. Winterize your plumbing lines and fixtures 6. Bypass hot water heater when winterizing to avoid water heater damage 7. Rinse black tank to help control odors and prevent sewage buildup 8. Rinse off items outside unit with a hot/cold faucet 9. Connect up to three (3) coax lines with satellite, cable and auxiliary

IMPORTANT!! NEVER push check valve on "CITY WATER" connection with pressure in line. This WILL cause irreparable damage to the check valve function.

INSTALLATION INSTRUCTIONS USER INSTRUCTIONS Nautilus P1 Handle Position and Valve Routing Information WHITE HANDLE: Receives water from water inlet on front of panel Sideways water goes into blue handle diverter Down water goes to pump inlet BLUE HANDLE: Receives water from white handle valve/water inlet on front of panel Sideways water goes to or comes from fresh water tank Down water goes to fixtures (cold) BLACK HANDLE: Is an on/off flow through valve that feeds pump from fresh water tank Sideways - water will not flow through valve Down water goes to or comes from fresh water tank RED HANDLE: Receives water from cold water supply line Sideways - water goes to hot water fixtures without going through hot water heater Up water goes to hot water heater GREEN HANDLE: Receives water from pump Sideways - water goes to fresh water tank Up water goes to fixtures

CONNECTING COAX FOR CABLE AND/OR SATELLITE 1. For cable TV connection, connect the threaded coax from the source to the "CABLE" connection. 2. For satellite TV connection, connect the threaded coax from the satellite dish to the "SAT" connection. 3. Consult your Owner's Manual to see if the "AUX" connection has an application.

Power Filling Fresh Water Tank "PowerFILL TANK" 1. Connect garden hose to inlet labeled "CITY WATER CONNECTION." 2. BLACK diverter handle should be facing right as shown. 3. BLUE diverter handle should be facing left as shown. 4. WHITE diverter handle should be facing right as shown. 5. RED diverter handle should be facing up as shown. 6. GREEN diverter handle should be facing right as shown 7. Turn water on. Fresh water tank should begin to fill. 9. When water has reached desired level in tank, turn water off at source. 8. Consult your Owner's Manual for tank capacity. DO NOT OVERFILL TANK! 10. Disconnect garden hose at source before disconnecting from Nautilus panel.

Siphon Fill or Sanitize Fresh Water Tank via Pump "SANITIZE" 1. Connect garden hose to inlet labeled "CITY WATER CONNECTION." 2. BLACK diverter handle should be facing right as shown. 3. BLUE diverter handle should be facing down as shown. 4. WHITE diverter handle should be facing down as shown. 5. RED diverter handle should be facing left as shown. 6. GREEN diverter handle should be facing right as shown. 7. Place other end of hose in container holding water or sanitizing solution. 8. Push "PUMP" switch so that the light on switch is lit.

Siphon Fill or Sanitize Fresh Water Tank via Pump "SANITIZE" 9. Pump should be running and fresh water tank should begin to fill. USER INSTRUCTIONS 12. Disconnect garden hose from inlet on Nautilus panel. 10. Consult your Owner's Manual for tank capacity. DO NOT OVERFILL TANK! 11. When desired level in fresh water tank is reached, turn pump off by pushing "PUMP" switch so that it is not lit.

Using Pump to Supply Water from Fresh Tank "DRY CAMPING" 1. Make sure fresh water tank has necessary supply of water. 2. BLACK diverter handle should be facing down as shown. 3. BLUE diverter handle should be facing down as shown. 4. WHITE diverter handle should be facing right as shown. 5. RED diverter handle should be facing up as shown. 6. GREEN diverter handle should be facing up as shown. 7. Push "PUMP" switch so that the light on switch is lit. Select pump switch located on inside of unit or on Nautilus Panel. 8. Pump should now run and water should be available to all fixtures. 9. Make sure pump is turned off when not in use.

Using System from Pressurized Water Source "CITY WATER" 1. Connect garden to hose to inlet "CITY WATER CONNECTION." 2. BLACK diverter handle should be facing right as shown. 3. BLUE diverter handle should be facing down as shown. 4. WHITE diverter handle should be facing right as shown. 5. RED diverter handle should be facing up as shown. 6. GREEN diverter handle should be facing up as shown. 7. Turn "on" water at the source. Water should be available to all fixtures.

Winterizing Plumbing Lines and Fixtures "WINTERIZE" 1. Turn handles to "POWERFILL" position as shown. BLACK diverter handle should be facing right. BLUE diverter handle should be facing left. WHITE diverter handle should be facing right. RED diverter handle should be facing up. GREEN diverter handle should be facing right. 2. Open low point drain on RV to remove water in plumbing lines. Open both a hot and cold faucet to help drainage process. 4. Once most water has been drained from plumbing lines, turn RED, BLUE, GREEN and WHITE handles so they are at a 45 degree angle as shown. 3. Open drain plug on hot water heater to drain water if unit is equipped with hot water holding tank. (Contact your dealer or manufacturer for exact location of low point drain hot water heater.)

Winterizing Plumbing Lines and Fixtures "WINTERIZE" 5. Using "CITY WATER" inlet or low point drain, blow out plumbing lines (40 PSI max) with handles still at 45 degree angle as shown. This will ensure any trapped water in plumbing harness is removed. 6. Close low point drain & hot water heater drain. 7. Turn handles to "WINTERIZE" position. BLACK diverter handle should be facing right as shown. BLUE diverter handle should be facing left as shown. WHITE diverter handle should be facing down as shown. RED diverter handle should be facing left as shown. GREEN diverter handle should be facing up as shown. 8. Connect a short section of garden hose to inlet labeled "CITY WATER CONNECTION."

Winterizing Plumbing Lines and Fixtures "WINTERIZE" 9. Place other end of garden hose in container holding approved winterizing solution. 10. Push "PUMP" switch so that light on switch is lit. Note: A short or cut off section of garden hose Should help the pump to prime easier. 11. Pump should be running and winterizing solution should begin to flow through pump into plumbing lines and fixtures. (The pump will run when a plumbing fixture is open.) 14. Turn BLUE, GREEN and WHITE handles so they are at a 45 degree angle for 10 seconds as shown. 12. Open one plumbing fixture, keeping it open until winterizing solution appears, then close. 13. Follow above procedure until all inside and outside plumbing fixtures have been winterized. Important! Make sure to run winterizing solution through hot & cold lines on exterior shower. 15. Push "PUMP" switch so that light on switch is not lit

Winterizing Plumbing Lines and Fixtures "WINTERIZE" 16. Return BLUE, GREEN and WHITE handles to "WINTERIZE" position as shown. 17. Disconnect garden hose from "CITY WATER CONNECTION" inlet. It is normal for some winterizing solution to exit inlet as hose is being disconnected.

Rinsing the Waste Tank "TANK FLUSH" 1. Connect flexible sewer hose to 4" dump outlet. 2. Open black waste holding tank valve and leave open. Allow tank to drain. 3. Attach a garden hose to inlet labeled "TANK FLUSH." 4. Fully open faucet at water supply source (40 psi minimum) flushing tank until water appears clear in 4" discharge hose.

Rinsing the Waste Tank "TANK FLUSH" 5. Completely close faucet at water supply source. 6. Disconnect garden hose from water supply source. 7. Disconnect garden hose from "TANK FLUSH" inlet. 8. Close black waste holding tank valve. NOTE: To help keep debris from clogging tank sprayer orifices, use the Tank Flusher every time waste holding tank is emptied.