Safety Please be mindful of the following for the installation, maintenance, wiring, and related inspections:

Similar documents
IR Intelligent Speed Dome Installation Manual

SCR100 User Manual. Version:1.1 Date:Dec 2009

Intelligent Speed Dome Installation Manual. Version 1.0.0

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

3-inch 2 Megapixel Intelligent Network Speed Dome Installation Manual. Version 1.0.0

INSTALLATION INSTRUCTIONS

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

IR Intelligent Positioning System Installation Manual

High Speed Positioning System Installation Manual

E1000 Portable gas detector

OPERATING MANUAL CUSTOMER SERVICE NO

ModBus DE-1 INSTALLATION AND USER MANUAL

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

Nardalert S3 TM Non-Ionizing Radiation Monitor

ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Infrared Moisture Determination Balance FD-610. Operating Manual

Dahua HD Mini IR Waterproof Bullet Network Camera. Quick Start Guide

IMR EX610. Portable Gas Detector. Operation Manual

TCB-IFTH1GUL. 24V Thermostat Interface. Installation Manual. Model name: English FOR INSTALLER

VPS3 Installation Manual

EST User Manual. (Please read this manual carefully before using)

Model: A Quick Setup Guide DC: Atomic Projection Alarm Clock

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Homeowner s Installation Instructions & Operating Manual

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

EW 40 Wireless Fan Control

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal

PLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL

Network Speed Dome Installation Manual

IMR IX176 Portable Gas Detector User Manual

Ionizer (Static Remover) STABLO-EX Instruction Manual

2-inch HDCVI Speed Dome Installation Manual

2-inch Network Speed Dome Installation Manual

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

Homeowner s Installation Instructions & Operating Manual

Model: C87207 / C87061 Instruction Manual DC: DUAL ALARM CLOCK

Refrigerated Incubator Model and Operating Instructions

EduCam360-B. Fisheye Panorama Network Camera Manual

TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

OPERATION / INSTALLATION

ELMTEC. Kattreppeln Königslutter / /

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

SAVE THESE INSTRUCTIONS

Chapter 5 Inspection and maintenance

Dual Spin Mop Robot Cleaner

MB23 and MB25 Moisture Analyzers

BUILDING DISTRIBUTOR CCU-BS

Specifications Minimum Typical Maximum Unit

IntesisBox BACnet/IP Server - Notifier ID3000 series

LM40 Medium Intensity Aviation Obstruction Light

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

CONTENTS CONTROLS 3-STAGE AIR PURIFICATION. X This product is suitable for 120V only. User Manual. Odor sensor. ➌ PlasmaWave

Series Temperature Controller Instruction Sheet

Coolant Heater Thermo Top (TTC) Heavy-duty Operating Instructions Installation Instructions

Model Communication Interface Sensors 2JCIE-BL01 Bluetooth low energy Temperature, Humidity, Light, UVI, Absolute pressure, Noise, Acceleration

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Model KBF 240 Constant climate chambers with large temperature / humidity range

Analog Room Pressure Monitor RPC Series

Insert Electric Fireplace IF-40FSB IF-50FSB IF-60FSB. Please read all instructions carefully and Retain for future reference

INTEGRATED VOICE EVACUATION SYSTEM VX-3000 SERIES

CEILING SPEAKER SYSTEMS F-2352CU2

Ceiling Mount Temperature Sensor

Quick Alert Remote (QA216R)

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Advance Optima Module Magnos 17

1.1 Remote Annunciator Controller (RAC) using the one ATC-300+ connected via RS-485 network.

Air conditioner. User manual AC777KN4DCH

Installation Guide for inbiox60 Series Access Control Panel

Air Dehumidification System. Instruction Book CLI-DH8D

40 Built-in Electric Fireplace Operating and Installation Instructions

OWNER S MANUAL LG CORDLESS VACUUM CLEANER

V-PIX Vision Bar LED Pixel Bar Light. User Manual KEEP THIS MANUAL FOR FURTURE NEEDS

Long Range Radio Alarm Transmitter

IR Intelligent Speed Dome Installation Manual

Dahua 2-inch Network Speed Dome Installation Manual Version Dahua Technology CO., LTD

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

Advanced Ultraviolet Burner Controller

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

3. Thermal switch (70 o C thermostat) with a 3 m connection cable

Dahua 2-inch HDCVI Speed Dome Installation Manual Version Dahua Technology CO., LTD

FTTHARCFUSIONSPLICER AD620

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

IntelliDoX Operator Manual

Tri-Tech Medical Inc.

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Digital 7 Square Plate Magnetic Stirrer

WIRELESS COLOR WEATHER STATION

INSTALLATION INSTRUCTIONS. Anti Knocking System, AKR 3. Document no.: A SW version:

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

ELIMINOSTAT DC-ESR-CL-S2

EL-USB-TC Thermocouple Data Logger with USB Interface

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

8-port Unmanaged Industrial Ethernet Switch Hardware Installation Guide

Transcription:

Operation Instructions for T300 Thank you for choosing the ViewX human-machine interface. For more efficient use of the ViewX human- machine interface, please read the included quick startup guide before using this product. In addition to the HMI machine, this package includes the following items: One DC socket terminal block (socket terminal block, P=5.08mm) Four retaining brackets (made of iron and 2set screws Metric M4*25 Machine Dimensions The machine is 96 mm in width, 96 mm in height, and 33 mm in depth. (including the height of the power socket terminal block) Installation Dimensions The opening size of the T300HMI is 91mm*91mm with an error of +1mm. Please do not leave the set screws over tightened or unbalanced. The maximum torque of the retaining bracket is 0.3 Nt m. Safety Please be mindful of the following for the installation, maintenance, wiring, and related inspections: Please follow the instructions to install ViewX HMI to avoid damage to the equipment. It is prohibited to expose ViewX HMI to environments with high humidity, hazardous gases and liquids to avoid electrical shock or fire hazard. Please make sure the ground terminal is below 100Ω before connecting it to ground. Poor grounding may cause poor signal reception, electric shock, or fire hazard. The operation of ViewX HMI requires dedicated planning software. Failure of software planning or ViewX HIM verification may cause abnormal machine operation. Please remove the socket terminal block from ViewX HM I during wiring. Only one wire can be inserted into each slot of the inlet on the quick connector. In case of error, remove the wire. Examine the wire and start the machine again. Please use wiring materials by following the specifications. The communication wires must comply with the specifications. Correct ground loop must be used to avoid communication problems. 1

Please read these instructions carefully before operating the machine and be mindful of the following reminders! Beware of the environmental safety. (hazardous gases, caustic liquid, high humidity, elevated operation, and dangerous operation) Please follow the instructions for HMI wiring. Make sure secured ground engineering and conduct all jobs by following the National Electrical Code. (Please see NFPA 70 - National Electrical Code (2008)) When the power is on, please do not conduct any disassembling or wiring modifications. During the HMI operation, please do not touch the power. For any questions about machine operation, please contact your local distributors. In addition, all new information of our products will be updated on our website. Please check at your convenience to download the most recent operation instructions. Other Notes of Caution: Do not alter the wiring when the power is still on to avoid electrical shock or personal injury. Please do not touch the panel with sharp objects, which may cause operation problems of the ViewX human-machine interface. It is prohibited to disassemble the ViewX human-machine interface to avoid electric shock. Once the power is turned on, it is prohibited to disassemble the panel of the ViewX human-machine interface. Within ten minutes after the power is turned off, it is prohibited to touch the connection terminal of the ViewX human-machine interface, for the residual voltage may cause electric shock. When the ViewX human-machine interface is in running, the vent must be kept clear to avoid Conditions of Installation abnormal signals or malfunction caused by machine overheating. Environment This product must be stored in the packaging box if it is to be used immediately. To ensure that the Conditions of Installation Environment This product must be stored in the packaging box if it is to be used immediately. To ensure that the product will be eligible for warranty and future maintenance, the storage must be done by the following measures: Store in clean and dry locations. The temperature of the storage environment must be -20 C~+60 C. The humidity for storage must be 20~85% RH (with no condensation) Avoid storing the package in any environments with dangerous or harmful materials (please look for signs for Dangerous and Harmful Materials of General Rules) Please store the package on attended countertop or shelf. Locations suitable for installation include: clean room, environment with no high temperature (no high temperature operation), locations with no water drops, steam or dust, environment with no dangerous or harmful materials, locations without dust and smoke,; locations with no vibrations and high intensity of electromagnetic waves. Orientation and Space of Installation Notes of Caution The installation must be done by the instructions. Otherwise, improper installation may cause malfunction. To ensure good cooling during the HMI operation, the HMI must be installed with at least 50 mm of space on the four sides and adjacent environment to avoid accumulation of heat. The maximum thickness of the installed panel cannot exceed 5 mm. Descriptions of Individual Parts 2

T300(Front) E D C B A A RUN: The red light indicates STOP and program download pending. Blinking green light indicates normal operation B Link: Connection indicator C DISC: Memory Access D Operation/Display Area E Alarm indicator T300(back) A C B A B C Power Input Terminal COM1communication port COM1:RS232/RS422/RS485 COM1 RS422/R485 terminal resistance(120ω)switch T/N:Terminal Resistance ON/OFF DC24V 0V FG COM1 COM2 3

Machine/Opening Dimensions (Unit:mm) Opening Dimensions Recommended wiring materials Type Power wiring (AWG) Strip Length Single Core wire 28~12 7~8 mm Multi-Core wire 30~12 7~8 mm 4

Basic Inspection Items of inspection General Inspection Inspection before Operation (Control power is not supplied) Inspection before Running (control power is supplied) T300COM1/COM2 Connector (DB 9) Content of Inspection Regularly inspect if the screws and connection points between the HMI and the equipment are intact. The vent opening should be kept clear and not be blocked by any objects. Beware of falling of small foreign objects in installation. If the HMI is installed in locations with dust and harmful gases, it is necessary to install the facility or equipment that can block the dust and harmful gases Please appropriately insulate the connection segment of the wiring terminal. Ensure correct wiring to avoid abnormal actions. Inspect for any conducting materials such as small metal flakes inside the HMI and watch for hazardous substances such as flammable materials and inflammable gases. If the electronic instruments near the HMI are affected by the electromagnetic interference, please use the calibration instrument to reduce the interference. Please make sure the voltage of the HMI is correct and stable Check whether the power indicator is on. Check if the communications between various systems are normal. Please contact your local distributor if there is any abnormal behavior by the HMI. COM Port 1 Schematic diagram Pin Number Description 1 COM1RS422 RX+ Download Adaptor Wire PC DB9 FEMALE 2 COM1 RS232 RX 3 COM1 RS232 TX 4 COM1RS485 TX+ 5 GND 6 COM1RS422 RX- 7 COM1 RS232 RTS 8 COM1 RS232 CTS 9 COM2 RS485 TX- T300TDB9 FEMALE Pin 2.RS232 RX Pin 3.RS232 TX Pin 5.GND Pin 2. COM1 RS232 RX Pin 3. COM1RS232 TX Pin 5.GND 5

Schematic Diagram for Installation: 91 91 Please place the HMI with its back facing the opening side of the machine Please install the metal retaining bracket on the side of T300with the metal clip hooking the front cap and the top of the screw pushing against the inside of the control box. Please secure the screws on the side (the maximum torque for the retaining bracket is 0.3 Nt m) 6

Product Specifications Display Device Function Specifications Central Processing Unit (CPU) Memory Communication Port Calendar Display Type Display Size Display Color Brightness Product Specification T300 32 Bits RISC 512K COM1 (RS-232/RS-422/RS-485) Built-in (powered by rechargeable lithium battery) FSTNLCD 3inches Black 100cd/ m2 Screen pixels 132*64 Brightness Adjustment Contrast Adjustment Digital(0-100) Digital(0-100) Screen Contrast Ratio 5:1 Backlight Language Blue LED All texts available in Windows Touch Panel Type 6-System Buttons,8-self-define Buttons Electrical Specifications Environmental Specifications Machine Dimensions Audio Output Rated Voltage Power Consumption Anti-statics Working Temperature Storage Temperature Humidity Anti-Shock Capability Buzzer 10~30V DC Below 3W Contact discharge:-6kv~+6kv(grade 3 by IEC61000-4-2) Non-contact discharge:-15kv~+15kv (Grade 4 by ICEC61000-4-2) 0 ~45-20 ~60 20~85% RH(no condensation allowed)) 10Hz~25Hz(0.5 mm along X, Y, and Z directions for 30 minutes) Waterproof Capability IP65/NEMA4 Cooling Natural air circulation Exterior Dimensions mm 96*96*33 Opening Dimensions mm 91*91 Weight Exterior Material 152g ABS(Acrylonitrile Butadiene Styrene) 7

T300 International certification mark 8