EHH SERIES DRAW THROUGH FAN COILS CFM

Similar documents
LOW STATIC HYDRONIC DUCTED UNIT

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

SECTION FAN COIL UNITS

YAH SERIES FAN COIL UNITS

Product Specifications. Vertical Floor Consoles By First Co.

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

SeasonMaker ThinLine Fan-coil Units

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Centeral Station Air Handling Unit

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

1.1 This section applies to air handling units for HVAC Systems.

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

VERTICAL FAN COIL UNITS

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

SeasonMaker ThinLine Fan-coil Units

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

AIR HANDLER SPECIFICATION

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

SKYPAK II, 3 Ton Series, gives you a

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Advance Release September 2009

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Product Catalog. DCHC Horizontal Concealed Chilled Water Fan Coil with DCBL Motor Airflow: 180~2380 m 3 /h

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

PACKAGE AIR CONDITIONER

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

Concealed Ducted Split Series R-407C MBH

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

SKYPAK II, 3 Ton Series, gives you a

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Cooling/Heat Pump Convertible Air Handlers

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

MAC-120HE-03 Air-Cooled Chiller

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Cooling/Heat Pump Convertible Air Handlers

MAC N-407 Air-Cooled Chiller

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

MACH N-407 Heat Pump Air-Cooled Chiller

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

CWA4 Chilled & Hot Water Fan Coil

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

FCC Fan-Coil Units High-Performance, Vertical

KIC Air Curtains. Technical Guide

Modular Supply Make-Up Air Unit

AIR COOLED PACKAGED CHILLER

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Cooling/Heat Pump Convertible Air Handlers

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

FAN COIL UNITS. The optimal solution for limited space

VariCool VAV Engineering Guide

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

CENTRAL SPLIT UNIT UNIC

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Vertical Upflow Horizontal Left Air Handlers

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Blower-YEFB-020-3R-1maxVel

Transcription:

EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM

TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE In the ever evolving world of HVAC, GemCool offers tremendous customizability to offer the consumer maximum amount of options. Whether it is our Fan Coil units or our Air Handling Units, all requirements can be fulfilled by our technical personnel. Our computer selection program gives detailed technical information for the Air Handling Unit to allow easy selection and installation of equipment. The same technical selection software can also be used for selecting coil for fan coil units. With the increasing shift to district cooling, a major concern is the capability of the fan coil units to handle high water temperature rise. GemCool alleviates these concerns with the selection program which enables the engineer to select the appropriate units according to design conditions. All GemCool equipment are manufactured according to strictest international standards to ensure highest quality and performance. The Air Handling Units are assembled in a facility conforming to ISO 9001 standards. Our Air Handling Unit coils are made as per ARI standards and our fans are AMCA certified. The motors conform to the highest international electrical standards available. All our equipment are well insulated to prevent cold bridging. 2

INTRODUCTION GEMCOOL Ceiling Concealed Fan Coil Air Conditioners are designed specifically to meet the many and varied requirements demanded of horizontal ceiling concealed units. They offer effective zone cooling control and are especially suitable for use in Apartments, Hotels, Shopping Centers, Office Buildings and Hospitals. Twelve sizes with capacity ranging from 400 to 5,000 CFM are available allowing GEMCOOL fan coil air conditioners to precisely match the room load requirement of a homogenous zone, assuring maximum performance and operating efficiency with lowest installation cost. FEATURES WHISPER QUIET OPERATION A Large-Diameter fan and low RPM motor mean that minimal noise will transmitted to the conditioned space. In addition, three fan speeds allow the user to select the appropriate user condition. HIGH WATER TEMPERATURE RISE GEMCOOL s specially designed coils permit water temperature rises higher than 10 F. This reduces the water flow rate and perfectly suits district cooling systems. 12 SIZES OFFER WIDE CAPACITY O RANGE from 400 to 5,000 CFM. The many unit sizes allow GEMCOOL ducted fan coil air conditioners to precisely match the room load requirements assuring maximum performance and operating efficiency. FASTER, EASIER MAINTENANCE GEMCOOL s unique design allows easy and fast access to unit components. The motor-blower assembly can be easily removed for service. SIMPLE INSTALLATION The complete factory assembled, piped and wired units allow for easy and swift installation. All plenums are shipped in place with either bottom or rear return air, as specified. In addition, the coil connection hand is also available as per requirement. HIGH STATIC PRESSURE EHH Series units are suitable to work upto 175 Pa (0.7 water gauge) static pressure. OPTIONAL FEATURES 6 row coils Different coil configurations Stainless steel construction Corrosion coating on coil Decorative Unit Thermostat and Valve Package available seperately Electric Heater 3

CONSTRUCTION GUIDE SPECIFICATIONS Structure is composed of pre-painted heavy gauge GI sheet (conforming to ASTM 653A) with excellent mechanical characteristics. The outer surface is prepainted to RAL 9010 at 50-70 micron. The complete unit is insulated using polyethylene foam insulation bonded the inner surface. Such an arrangment permits high strength, low thermal transfer, high noise absorption and low flammability. The different panels are joined together by means of self tapping screws to prevent air leakage and to make one complete structure. They can be easily removed to perform various maintenance tasks. Stainless Steel outer and inner skin is available as another option for hygenic units. Hanging brackets are attached to the unit outer body to facilitate secure and prompt hanging. FAN MOTOR ASSEMBLY Units are equipped with double inlet, double width, forward curved centrifugal fans. All fans are made from hot dip galvanized steel to prolong longetivity. Fans are statically and dynamically balanced to prevent vibration. The fan housing shall be of galvanized steel. The inlet cones are aerodynamically formed to avoid turbulence and are easily removable Selection of fans are done to meet the specified air flow and static pressure at low outlet velocities and optimum motor safety factor. All air flows and corresponding static pressures and fan RPMs given by selection program are checked and verified by physical tests. All units come with variable speed controller to easily change the airflow and ESP to match project requirements. Fans can be supplied in different positional orientations according to the project requirements. Fan flange is directly attached to the body to facilitate quick duct attachment. All units are provided with a factory installed terminal box with the motor wired to the box. The single phase three speed induction motors comply with low voltage IEC standards. All motors are permanent split capacitor type with sleeve bearings. Transmission is effected via keyed shafts. Motors are mounted on rigid bases to offer rigidity, isolate vibrations and prevent movement. All motors come with an auto reset overload protector. Motor shafts are pre-treated to protect against corrosion. COILS In order to offer true unit selection, coils are available with three different cooling medium - water, refrigerant and glycol. Standard water cooling coils are available from three to six rows. All units are supplied standard with 4 row coils. 4

Circuiting is done by computer selection to keep the cooling media pressure as optimum as possible. Coils are fabricated of 3/8 OD copper tubes. Fins are made of aluminum and are pressure bonded to the tubes through mechanical expansion. Fins are selected to provide maximum contact area while minimizing air pressure drop. Coils are encased in galvanized steel. Headers are made of seamless copper brazed to the tubes. All headers are male BSP threaded to allow fast and secure connections.air vents are provided on each header for water coils. Both headers are on the same side as the access for the fan and filter. Coil headers are secured to the unit body by means of a special quick release plate. All coils are pressure tested at a minimum pressure of 350 PSI. All coils are rated in accordance to ARI 410. All coils are selected at a face velocity below 2.5m/s (500 fpm). All coils are factory tested for leaks before installation and dispatch. The drain pan is of painted GI construction with polyethylene insulation and drain pipe. Drain pan can be changed to right or left hand connection on site. The whole coil and drain pan assembly slides on guides allowing easy access to the coil. FILTER SECTION Filter is an aluminum mesh type with metallic frame. It can be easily withdrawn from the side or bottom. Filter thickness is 1/2. 5

UNIT D 7 5 4 (1) Adjustable motor speed control. (2) Fully insulated threaded heavy gauge copper headers. (3) Threaded drain pan outlet. (4) Dual fans for maximal air flow with low noise. (5) Heavy gauge pre-painted corrosion resistant steel. (6) Fan flange for easy attachment to duct. (7) Sturdy holders for easy and secure hanging of unit. (8) Access panels for easy access to components. 6

ETAILS 2 6 8 3 1 7

TECHNICAL DATA Unit Size EHH 12 EHH 18 EHH 24 EHH 30 EHH 36 EHH 48 EHH 60 PERFORMANCE Nominal Air Volume Rating Static Pressure High Speed Medium Speed Low Speed CMH 733 1,119 1,564 1,775 2,295 2,910 3,570 CFM 431 658 920 1,044 1,350 1,712 2,100 CMH 595 901 1,063 1,455 1,909 2,589 3,145 CFM 350 530 625 856 1,123 1,523 1,850 CMH 408 595 884 1,321 1,681 2,191 2,763 CFM 240 350 520 777 989 1,289 1,625 Pa 50 50 75 75 75 75 125 Nominal Total Cooling Capacity Btu/hr 12,000 18,000 24,000 30,000 36,000 48,000 60,000 kw 3.52 5.28 7.03 8.79 10.55 14.07 17.58 MOTOR Type Motor Power Output Motor Power Input Qty Electrical Supply Motor Current (220V/1φ/50Hz) Poles 3-speed Permanent Split Capacitor Motor Watts 50 80 150 200 275 400 600 Watts 141 165 273 370 554 693 1019 1 1 1 1 1 1 1 220V/1φ/50Hz & 220V/1φ/60Hz Amps 0.64 0.75 1.24 1.68 2.52 3.15 4.63 4 FAN Type Qty Forward Curved Steel Impeller Centrifugal Fan 2 2 2 2 2 2 2 COIL Type Number of Rows / FPI Tube Face Area Chilled Water Connection Refrigerant Piping (Liquid) Refrigerant Piping (Gas) Seamless Copper Tube / Corrugated Aluminum Fin 3 or 4 or 6 Rows / 12 or 14 FPI 9.52mm O.D. ft 2 0.81 1.22 1.62 2.03 2.44 3.44 4.26 3/4" BSP Male Socket 1/4" 3/8" 3/8" 1/2" 1/2" 1/2" 1/2" 1/2" 5/8" 5/8" 3/4" 3/4" 3/4" 3/4" FRAME Casing Insulation Prepainted Steel Polyethylene Foam - 5mm DRAIN PAN Material Connection Prepainted Steel 3/4" O.D. Steel Pipe DIMENSION Depth Width Height Estimated Weight mm 600 600 650 650 627 650 655 mm 960 960 970 1115 1235 1305 1575 mm 260 260 320 315 315 345 350 kg 33 44 50 50 56 65 68 8

TECHNICAL DATA (contd.) Unit Size EHH 75 EHH 90 EHH 105 EHH 120 EHH 150 EHH 180 EHH 210 EHH 240 PERFORMANCE Nominal Air Volume Rating Static Pressure High Speed Medium Speed Low Speed CMH 4,197 5,202 6,078 6,919 8,265 10,200 11,900 13,600 CFM 2,469 3,060 3,575 4,070 4,862 6,000 7,000 8,000 CMH 3,392 4,284 5,131 5,647 6,994 - - - CFM 1,995 2,520 3,018 3,322 4,114 - - - CMH 2,667 3,264 4,005 4,825 5,947 - - - CFM 1,569 1,920 2,356 2,838 3,498 - - - Pa 125 150 175 200 175 350 450 500 Nominal Total Cooling Capacity Btu/hr 75,000 90,000 105,000 120,000 150,000 180,000 210,000 240,000 kw 21.98 26.38 30.77 35.17 43.96 52.75 61.55 70.34 MOTOR Type Motor Power Output Motor Power Input Qty 3-speed Permanent Split Capacitor Motor Watts 600 500 500 600 750 3,000 4,000 5,500 Watts 1,019 946 946 1,019 1,221 3,000 4,000 5,500 1 2 2 2 2 1 1 1 Electrical Supply 220V/1φ/50Hz & 220V/1φ/60Hz 400V/3φ/50Hz & 400V/3φ/60Hz Motor Current (220V/1φ/50Hz) Poles Amps 4.63 4.30(x2) 4.30(x2) 4.63(x2) 5.55(x2) 6.80 8.80 11.80 4 FAN Type Qty Forward Curved Steel Impeller Centrifugal Fan 2 2 2 2 2 2 2 2 COIL Type Number of Rows / FPI Tube Face Area Chilled Water Connection Refrigerant Piping (Liquid) Refrigerant Piping (Gas) Seamless Copper Tube / Corrugated Aluminum Fin 3 or 4 or 6 Rows / 12 or 14 FPI 9.52mm O.D. ft 2 5.26 6.10 7.11 8.26 10.27 12.36 14.38 16.43 1" Male 1-1/4" Male 1-1/2" Male 1-3/4" Male 2" Male 1/2" 5/8" 5/8" 5/8" 3/4" 3/4" 5/8" x 2 5/8" x 2 3/4" 1-1/8" 1-3/8" 1-3/8" 1-5/8" 1-5/8" 1-3/8" x 2 1-3/8" x 2 FRAME Casing Insulation Prepainted Steel Polyethylene Foam - 5mm DRAIN PAN Material Connection Prepainted Steel 3/4" O.D. Steel Pipe 1" O.D. Steel Pipe DIMENSION Depth Width Height Estimated Weight mm 715 720 740 790 840 840 840 840 mm 1650 1750 1793 1779 2046 2046 2046 2046 mm 400 400 440 520 540 640 740 840 kg 79 110 135 175 230 265 310 385 9

DIMENSIONS Model a b c d e f g h i j k l m n o p r EHH 12 600 960 260 910 380 720 170 22 68 40 170 560 180 235 65 90 170 EHH 18 600 960 260 910 380 720 170 22 68 40 170 560 180 235 65 90 170 EHH 24 650 970 315 920 440 720 170 22 120 50 230 560 180 235 102 85 165 EHH 30 650 1115 315 1065 420 840 170 22 120 50 225 560 180 230 100 100 170 EHH 36 650 1286 315 1235 385 842 170 22 120 45 225 560 180 265 95 95 160 EHH 48 650 1305 345 1260 385 820 240 40 75 40 260 567 210 290 145 90 175 EHH 60 655 1575 350 1520 375 820 240 22 90 50 255 567 210 295 150 90 165 EHH 75 715 1650 400 1600 440 1040 200 22 170 50 305 625 210 295 180 100 160 EHH 90 805 1860 400 1810 550 1000 240 22 140 50 305 715 215 350 200 95 190 EHH 105 820 1890 450 1835 560 1200 295 22 130 45 350 730 210 395 240 100 165 EHH 120 820 1825 545 1770 550 1200 320 22 250 50 445 730 210 395 320 95 170 Notes: 1) All dimensions are in mm. 2) All dimensions are subject to change without any notification. 10

COMPUTER SELECTION To provide our customers with detailed technical information about the unit, Gem- Cool has developed a special selection program. This selection program has all relevant data stored into it allowing the user to do quick selections. It also allows the user to see technical data associated with different aspects of the FCU. After each selection of the unit, a printout is generated containing the technical data, a sketch and other information the user requests. The selection program can be used to select the optimum unit and all the relevant data can be sent to GemCool who can accordingly supply the unit. Unit Data Project Name FAN COIL UNIT SELECTION Project Reference Electrical Data Motor Type 3 speed Voltage Number of fans 2 Number of motors 1 Power Input 900 W Unit Reference FCU-02 to 05 Unit Model EHH 60 Unit Speed Medium Unit Static 70 Pa Number of Rows 4 Number of fluid passes 6 Air Data Air Flow 3060 m³/hr Face Velocity 2.13 m/s Entering Dry Bulb 24 C Entering Wet Bulb 17 C Entering Relative Humidity 49 % Entering Enthalpy 47.74 kj/kg Leaving Dry Bulb 12.96 C Leaving Wet Bulb 11.88 C Leaving Relative Humidity 88 % Leaving Enthalpy 33.87 kj/kg Physical Data Weight 66 kg Connection Size 1 in Fluid Data Fluid Type Water Fluid Flow 0.56 l/s Entering Fluid Temp 5.5 C Leaving Fluid Temp 11.49 C Water Velocity 1.07 m/s Water Pressure Drop 55 kpa Drain Size 1 in Capacity Sensible Capacity 11.46 kw Total Capacity 14.15 kw Model a b c d e f g h i j k l m n o p EHH 60 640 1532 340 1500 436 854 234 24 74 53 243 520 115 217 163 101 Noise Data Fan Speed High Medium Low Octave Bands Hz 1000 63 Hz 125 Hz 250 Hz 500 Hz 2000 Hz 4000 Hz 8000 Hz 53 59 61 60 57 54 50 44 45 51 52 50 48 43 41 37 31 39 41 39 37 35 30 26 Overall db(a) 60 57 47 1 2 11

GEMCOOL CORPORATION Sharjah Airport Free Zone, Sharjah / Emirates Industrial Zone, Umm Al Quwain Tel: +9714 223 2420 Fax: +9714 227 8011 Email: info@gemcool.net Web: http://www.gemcool.net Due to Gemcool s continuous efforts to innovate and improve its products, we reserve the right to modify any data or specification without any notification. C Copyright Gemcool Corporation. All rights reserved. Rev 0 24/06/13