LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Similar documents
REACTIon TANks. Pump control-telemetry Unit

APPLICATION DATA SHEET

RACO's Verbatim Gateway keeps you in touch, and in control, no matter where you are.

SUPREMATouch. Modular Fire & Gas Detection System

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Carbon Monoxide Transmitter

Variable Frequency Drive SERIES MP800 VFD

SUPREMATouch. Modular Fire & Gas Detection System

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

wireless. web-based. worthy of the name RACO.

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Two-Channel Gas Controller

Across-the-Line SERIES MP300 Combined Manual and Automatic

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Lift Station Level Controller

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

REMOTE MONITORING AND ALARM SYSTEM

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Process & TeMPerATUre UniversAl input DigiTAl MeTers

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

OJD ITB No Attachment E Duress Alarm Equipment Specifications

APPLICATION DATA SHEET

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

TrueAlarm Fire Alarm Controls

Soft Start Series MP700 Solid State, Reduced Voltage

YOUR PARTNER IN FIRE & GAS DETECTION

Integrated Security Solutions

Spectron LSN (Life Safety Network) Suggested Specifications

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Industrial Grade Gas Detection Detecting The Difference

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

LORAIN CSP DC Power System

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Oxygen (O2) Single-Point Gas Detection System

Model D12-IR. Digital Gas Transmitter...

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Med Touch Master Alarm

GasGard 100 Control System

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Nov 08 PRODUCT SPECIFICATION SHEET

Addressable Fire Alarm Control Panel

SMS GSM Alarm Messenger

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Intelligent Single Loop Fire Alarm Control Panel

Touchpoint Pro Flexible Gas Control System

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Gas Controller Module GC-06

/8 DIN Level Indicator

IGD.CO.UK

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Process Alarm Module RTA 421

WASTEWATER Online UV%Transmission Analyzer

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

Sequence of operation

Danfoss gas detection Controller unit

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

DIESEL Engine Fire Pump Controllers Features

Tri-Tech Medical Inc.

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

INTELLIGENT FIRE ALARM CONTROL PANEL

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

FMR Installation Instructions. Addressable Fire System Controller

STEAMPAK Series BurnerPAK BMS Burner Management Systems

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

SIMPLICITY BY DESIGN M52 CONTROLLER

Integrated Security Solutions

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

for Drinking Water Systems

CITY OF WHITEHORSE SERVICING STANDARDS MANUAL SECTION 2 - CONSTRUCTION DESIGN CRITERIA SUB-SECTION 2.A SCADA STANDARDS.

Why Choose Sensaphone? What Is A Sensaphone? If you have something important at a remote site, then you need a SENSAPHONE to watch it for you.

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

RTD TEMPERATURE SENSING SYSTEM

LifeAlarm Fire Alarm Control Panels

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

CLEANROOM MONITOR CR3A Network - Installation Instructions

Temperature Controllers

Transcription:

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Simply Features In Brief Telemetry Ready Security 2 or 3 Pump Control UL Listed Alarm/Event Log Volumetric Flow Calculator VFD Control Optional Dialer Optional Ethernet Port USFilter Control Systems is proud to introduce the LC150 Pump Controller, the newest addition to the family of View-At-A-Glance controllers. For nearly two decades, the D150 Series of View-At-A- Glance Pump Controllers has set the standard in the industry for ease of use and reliability. Now the LC150 provides the simplicity customers have come to expect with the advanced features they need all in one system! The LC150 is designed specifically for pump station applications and offers a simple, reliable and cost effective solution. The new "View-At-A- Glance" interface provides the operator with all the information needed to operate and maintain the pumping system and is UL listed and NEMA 4 rated. FEATURES Telemetry Ready - with the addition of a radio, phone line connection or connection to a high speed Ethernet interface (with the Ethernet option), the LC150 allows you to monitor station status, change pump start and stop setpoints, change high and low level alarm setpoints, acknowledge alarms, and view pump run, fail, and performance information remotely. If alarm notification is the only requirement, the optional integrated alarm dialer provides real voice notification of alarm conditions over a dial up telephone line. Versatile - the LC150 can be used to control and monitor up to three constant and/or variable speed pumps in either pump up or pump down mode. This versatility makes the LC150 useable even in difficult pump applications like pressure/flow controlled booster stations. Time and Date Stamped Alarm/Event Log - the LC150 logs the time and date that alarms and events occur. This historical log provides the operator with the ability to analyze pump performance and system failures. Volumetric Flow Calculator - the LC150 calculates flow rates based on level excursions and logs daily flow, flow rates per pump and average flow rate per pumping cycle. This information can be viewed locally at the operator interface and remotely via the telemetry connection. Password Protection - three levels of password security allows only authorized users to modify the controller parameters. Site Security - with the addition of a simple door switch or motion detector, the LC150 can function as a site security system used to detect unauthorized entry onto the premises.

the Easiest Most User Friendly Pump Control-Telemetry Unit on the Market Today Custom Scale Ranges Allows you to scale the controller display precisely to the process. View-At-A-Glance Operator Interface View all critical information including: on/off setpoints, level alarm setpoints, level alarms and the process variable without pressing any keys. Pump Up or Pump Down Mode Controls 2 or 3 pumps in either mode. Verify Proper Pump Operation Two simple up/down keys allows an operator to simulate the process. Drop in Replacement Operator Interface has the same footprint as D15x series products. No drilling or modifying the door. LCD with Backlighting 2 line x 16 character display and simple (4-key) key pad allows easy access to more advanced information. Alternation The LC150 supports multiple modes of operation configurable through the LCD and keypad. Alarm Control Easily silence audible alarms and reset latching alarm conditions. NEMA 4 Rated Operator Interface

the Most Advanced Pump Control-Telemetry Unit on the Market Today Pump Protection The LC150 controller will detect failed pumps, and take the failed pump out of service until corrected and reset. Time and Date Stamped Alarm/Event Log Stores the last 100 Alarm/Events. Two Piece Design Door mounted operator interface and DIN rail mounted I/O base. Volumetric Flow Calculation The controller can calculate station flows without the need for a flow meter. Security Protection 3 level password security Detect unauthorized station access (intruders) with a door switch input and an operator interface security password. Activates local alarm and telemeters unauthorized entry to a central monitoring point. Pump Run Data Total run time Total number of starts Daily run time Average number of starts/day Total pump flow Average flow rate of the pump A utility can monitor the pumps performance over time and perform maintenance on a pro-active basis rather than a reactive one. Calculated Flow Statistics Total station flow Average daily flow Maximum daily flow A utility can monitor station performance and spot potential problems.

Diagnostics On board communication and diagnostics LED support troubleshooting Built-in RS-232 Serial Port Supports Modbus and USFilter Open Protocols The LC150 Supports a Wide Variety of Communication Media Radio (UHF, VHF, Spread Spectrum) Ethernet (optional) 120 Volts AC or 10-30 VDC Operation APPLICATIONS Built-in Battery Charger Isolated Inputs Pull Apart Terminal Blocks Ease of Installation & Maintenance Sewage Lift Pump Station monitored wetwell level. Supports both level transmitter and float switch control inputs for primary and back up control strategies. WWTP Influent or Effluent Pump Station Controls pumps based on locally monitored wetwell level. Supports both level transmitter and float switch control inputs for primary and back up control strategies. Booster Pump Station monitored discharge pressure sensor or remotely telemetered tank level. Well Pump Station monitored pressure/level sensor or remotely telemetered tank level. Raw Water Pump Station monitored or telemetered flow rate/pressure/level sensor signal. Transfer Pump Station monitored wetwell level. Supports both level transmitter and float switch control inputs for primary and back up control strategies. Irrigation Pump Station monitored discharge pressure or flow rate.

SPECIFICATIONS Base Unit Power Supply Operator Interface Packaging Door mounted, 8.5 x 7.5 x 1.5 Power Level, Stage, Alarm Setpoint Display LCD Communications Port Supplied through communications cable from Base Unit LED columns, 40 segment, ultra bright 2 x 16 character, backlight, 4 key keypad RS232 w/power Environmental Rating NEMA 4 120 VAC or 10-30 VDC w/battery backup Packaging DIN rail mount, 5.4 x 7.5 x 2.25 Communications Port OI port, RS232 Telemetry Port, 10/100 Ethernet port (optional), 802-11 b/g wireless Ethernet (optional), Ethernet and serial ports support Modbus and USFilter Open, 32 channel auto-dialer (optional) Discrete Inputs 16 channels, max 30 VDC, isolated Pump/Alarm Outputs 5 channels, 10A @ 120 VAC relays High/Low Level Alarm Outputs 2 channels, Open collector, 100 ma @ 5-30 VDC Analog Input 1 channel, 4-20 ma or 0-10 VDC Resolution 16 bits Calibration Isolation Excitation Voltage Analog Output Certifications Software 1 KV 24 VDC or 6.2 VDC, isolated 1 channel, 0-5 VDC UL, FCC, CE Part Number Description Availability ILK-LC150001-01 LC150 Pump Controller, Base Unit, 16 DI, 5 relay outputs, 2 open collector outputs, Q3 2005 1AI, 1 AO, RS232 telemetry port ILK-LC150002-01 LC150 Pump Controller, Base Unit, 16 DI, 5 relay outputs, 2 open collector outputs, Q1 2006 1AI, 1 AO, 10/100 Ethernet port ILK-LC150003-01 LC150 Pump Controller, Base Unit, 16 DI, 5 relay outputs, 2 open collector outputs, Q1 2006 1AI, 1 AO, 802.11b/g wireless Ethernet port ILK-LC150004-01 LC150 Pump Controller, Base Unit, 16 DI, 5 relay outputs, 2 open collector outputs, Q1 2006 1AI, 1 AO, 32 channel Auto-dialer, voice annunciated alarms, touch tone acknowledge ILK-LC150020-01 LC150 Operator Interface Q3 2005 UL is a registered trademark of Underwriter s Laboratories, Inc. Modbus is a registered trademark of Schneider Automation, Inc. NEMA is a registered trademark of National Electrical Manufacturers Association. USFilter is a registered trademark of USFilter Corporation. USFilter reserves the right to change the specifications referred to in this literature at any time, without prior notice. CS-LC1-BR-0705 To find out more about how to put USFilter to work for you, contact us at USFilter Control Systems 1239 Willow Lake Boulevard Vadnais Heights, MN 55110 800-224-9474 toll free 651-766-2700 phone 651-766-2701 fax For more information, call 800.944.4811 or visit our web site at www.usfilter.com 2005 USFilter Corporation