RTHE Series R Helical Rotary Liquid Chiller Tons 60Hz

Similar documents
Series R Helical Rotary Water-Cooled Liquid Chillers

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

Series R Helical Rotary Liquid Chillers

Call us today! (800)

Series R Helical Rotary Liquid Chillers

Water-cooled chillers with High Speed Centrifugal Compressors

Call us today! (800)

XStream Water-cooled screw chillers and Water/Water Heat pumps

Series R Helical Rotary Liquid Chillers

Submittal. Date: September 04, Customer P.O. Number: Customer Project Number:

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Call us today! (800)

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

XStream Water-cooled screw chillers and Water/Water Heat pumps

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Air-Cooled Scroll Chillers

CVGF. Water Cooled Centrifugal Chillers

Wicomico County Purchasing 125 N. Division St. Room B-3 Salisbury, MD Ph Fax Addendum # 1

SECTION ROTARY-SCREW WATER CHILLERS

Product Catalog. Air-Cooled Scroll Chillers Model CGAM - Made in USA Nominal Tons (50 Hz and 60 Hz) CG-PRC017-EN.

Installation Operation Maintenance

Product Catalog Series R Helical Rotary Liquid Chillers RLC-PRC040D-EN

GP SERIES Packaged Chillers

AquaStream Air-Cooled Liquid Chillers

AquaStream 3G Air-Cooled Liquid Chillers

ATTACHMENT B SECTION SPECIAL CONDITIONS

Indoor liquid chiller and heat pump

Series R Rotary Liquid Chiller

Nirvana. Cycling Refrigerated Dryers

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

GeneSys. Air-Cooled Screw Compressor Chillers. Catalog

Air-Cooled Global Chiller

.2 Section Waste Management and Disposal.

Series R Rotary Liquid Chiller 70 to 400 Tons Air-Cooled

Product Catalog. Air-Cooled Series R Chillers Model RTAC Nominal Tons (60 Hz) RLC-PRC006-EN. May 2012

NQ Series Portable Chillers

Water-Cooled Screw Compressor Chillers

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

Air-Cooled Screw Compressor Chillers

Installation Operation Maintenance

Installation Manual. Gear-Driven Centrifugal Water- Cooled Liquid Chillers CVGF-SVN02B-E4 X

Installation, Operation, and Maintenance

Product Catalog. Air-Cooled Scroll Chillers Model CGAM Made in USA 20 to 130 NominalTons (60 Hz and 50 Hz) CG-PRC017N-EN.

SECTION CENTRIFUGAL WATER CHILLERS

Indoor liquid chiller with integrated hydraulic module

Nirvana Cycling Refrigerated Dryers

Air-Cooled Series R Helical-Rotary Liquid Chiller

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

Air-Cooled Modular Split Systems. Product Data Catalog

Water-Cooled Screw Compressor Chillers

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Innovation for a Better & Greener Future

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

MAC N-407 Air-Cooled Chiller

Installation Instructions

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Product catalog CG-PRC008-E4

OACS Outdoor Air-Cooled Central Chillers

AQUASNAP JUNIOR 30RHV

Open Protocol Data Communications

Water-Cooled Screw Compressor Chillers

A Career that will take you to heights you never imagined!

Water-Cooled Dual Compressor Screw Chiller

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

PACKAGED AIR COOLED Product Data Catalog

Product Catalog. Air-Cooled Scroll Chillers Model CGAM - Made in USA NominalTons (50 Hz and 60 Hz) CG-PRC017H-EN.

Air-cooled Chillers with High Speed Centrifugal Compressors

VariCool VAV Engineering Guide

Product Catalogue CG-PRC002E-EN. CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to 150 Tons. July Models: 50 / 60 Hz

Product Data. Features/Benefits ComfortLink control

MACH N-407 Heat Pump Air-Cooled Chiller

Indoor liquid chiller with integrated hydraulic module

19DV Back-to-Back Centrifugal Liquid Chiller with PUREtec TM Refrigerant and Greenspeed TM Intelligence

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

MODELS LIST. Nominal Capacity RT

Air-Cooled Condensing Units with Compact Screw Compressors

NEW CHILLER SCHEDULE

Trane Rotary Screw Air Cooled Chiller 100 Ton

Installation Operation Maintenance

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Installation Operation Maintenance

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

Guide Specifications

Product Catalog. Cold Generator Scroll Liquid Chillers Model CGWR and CCAR 20 to 65Tons (60 Hz) Water-Cooled and Compressor Chillers CG-PRC046A-EN

30KAV Variable Speed Air-cooled Screw Chiller

Screw Compressors HSD SERIES. Capacities from: 816 to 3002 cfm Pressures from: 80 to 217 psig

CHINOOK WARM AIR GAS FURNACE DESIGNED, ENGINEERED AND MANUFACTURED IN CANADA INCLUDING COMPONENTS MADE IN THE USA

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

C13-Series Engineering Guide

WXC R134a. Nominal Cooling Capacity from 224 to 692kW

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

ACMVTECH HIGH EFFICIENCY UNITARY AHU

Transcription:

Features Product and Benefits Catalog RTHE Series R Helical Rotary Liquid Chiller 75-255 Tons 60Hz January 2015 RTHE-PRC002-EN

Introduction To meet a wide range of applications in the 75~255 ton water-cooled market, Trane is proud to introduce the model RTHE helical-rotary liquid chiller. The introduction of this new chiller is an exciting step forward in reliability, high performance, life-cycle cost-effectiveness and simple, economical installation. The new RTHE chiller is designed to deliver proven Series R performance, plus all the benefi ts of an advanced heat transfer design and a low-speed, direct drive compressor. The industrial-grade design of the Series R helical-rotary chiller is ideal for both industrial and commercial markets, in applications such as commercial real estate, government, healthcare, education, retail, and industrial facilities. 2 RTHE-PRC002-EN

Features and Benefits Reliability The Trane helical rotary compressor is a proven design resulting from years of research and thousands of test hours, including extensive testing under extraordinarily severe operating conditions. Direct drive, low-speed compressors - a simple design with only four moving parts - provides maximum efficiency, high reliability, and low maintenance requirements. Suction gas-cooled motor stays at a uniformly low temperature for long motor life. Electronic expansion valve, with fewer moving parts than alternative valve designs, provides highly reliable operation. High Performance The superior low noise design means the chiller operates at the lowest noise level when compared to other product equivalents on the market. The electronic expansion valve with the Adaptive controltm logic can accurately adjust the fl ow of the refrigerant from 10% to 100%, based on loads. Optional LonTalk/Trace Summit or Modbus communications interface provides excellent, troublefree inter operability. Life Cycle Cost-Effectiveness The GP2 compressor, based on Trane's global development platform, employs low-speed, direct drive motors and hermetic structures. The motors are cooled by the refrigerant without being exposed to air, leading to an extended life. Precise compressor rotor tip clearance ensures optimal efficiency. Electronic expansion valve enables exceptionally tight temperature control, resulting in more efficient full-load and part-load operation than previously available. The compressor contains only 4 moving parts, meaning less mechanical losses and operational faults. The CH530 controller provides Feed Forward and Softloading functions, effectively eliminating the water temperature fl uctuations and frequent start of the chiller, thus extending the chiller's life. Simple, Economical Installation With its minimum width of only 916mm, the chiller s small footprint saves valuable equipment room space and alleviates access concerns for most retrofit jobs. Due to its plug-and-play design, the chiller can be put into service immediately after the water pipes and power supply are connected at sites, greatly decreasing the construction period Trane CH530 controls easily interface with Tracer Smmit, Modbus or LonTalk building automation systems through single twisted-pair wire. Trane has conducted extensive factory testing during manufacturing. RTHE-PRC002-EN 3

Options Pressure Relief Valve Dual RV with 3-Way Isolation Valve Refrigerant Isolation Valves Refrigerant Isolation Valves (Discharge and Liquid Line Valve) 2-Way Water Regulating Valve For water regulation, a fi eld-installed, 2-way butterfl y-type (lug-style) valve, with integral electrical operator and factory-mounted valve actuator, is available. Insulation The evaporator and water boxes are covered with factory in installed 1.5 inch (38.1 mm) insulation. Factory installed foam insulation is used on the motor housing, suction line, liquid level sensor, and oil return system assembly (with its associated piping). Circuit Breaker A molded case standard interrupting capacity circuit breaker, factory pre-wired with terminal block power connections and equipped with a lockable external operator handle, is available to disconnect the chiller from main power. Non-Fused Disconnect A non-fused molded case disconnect switch, factory pre-wired with terminal block power connections and equipped with a lockable external operator handle, is available to disconnect the chiller from main power. Communication Time of Day Scheduling COMM5 (Lontalk) BACnet MODbus External Current-Limiting External current-limit set point is communicated to a factory-installed, tested communication board through a 2 10 Vdc or 4 20 ma signal. Cond Refrigerant Pressure Output Condenser Water Control Condenser Pressure (%HPC) Differential Pressure Output Motor Current Analog Output Control system indicates the active chiller percent of full run load amps, based on a 2 10 Vdc. 4 RTHE-PRC002-EN

The Cutting-edge CH530 Controller Microprocessor-based Trane CH530 controls monitor and maintain optimal operation of the chiller and its associated sensors, actuators, relays, and switches, all of which are factory assembled and extensively tested. Easy interface with computers hosting LonTalk/Trancer SummitTM or Modbus building automation/ energy management systems allows the operator to effi ciently optimize comfort system performance and minimize operating costs. Proportional Integral Derivative (PID) control strategy ensures stable, effi cient chilled water temperature, maintaining ±1 F (0.56 C) by reacting to instantaneous load changes. Adaptive Control attempts to maintain chiller operation under adverse conditions, when many other chillers might simply shut down. This is accomplished by unloading the compressor due to high condensing pressure, low suction pressure and/or overcurrent. Easy-to-use operator interface displays all operating and safety messages, with complete diagnostics information, on a easily readable panel with a scrolling touch-screen display. Seamless integration with Trane s new generation of building automation systems -TRACER SC, featuring streamlined system architecture, a more instinctive user interface and user friendly operation offers users automated chiller plant services. RTHE-PRC002-EN 5

Model Number Descriptions R T H E 1 3 0 1 B A A A A A X X X X A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Digits 1-4 Digits 5-7 Product Family RTHE - RTHE Family Nominal tons 75-75 nominal tons 90-90 nominal tons 110-110 nominal tons 130-130 nominal tons 175-175 nominal tons 195-195 nominal tons 235-235 nominal tons 255-255 nominal tons Digit 14 Digit 15 Power Line Connection Type A - Terminal block connection B - Disconncet switch C - Circuit breaker Communication X - No remote digital comm 4 - Time of Day Scheduling 5 - COMM5 (Lontalk) 6 - BACnet 7 - MODbus Digit 8 Digit 9 Digit 10 Digit 11 Digit 12 Unit Voltage (60hz) 4-220 Volt 3 Phase 5-380 Volt 3 Phase 6-440 Volt 3 Phase Cond Waterbox Connection Direction A - 150psig + 2pass + LELE B - 150psig + 2pass + RERE Pressure Relief Valve A - Single Relief Valvet B - Dual RV with 3-Way Isolation Valve Refrigerant Isolation Valves X - None A - Refrigerant Isolation Valves (Discharge and Liquid Line Valve) 2-Way Water Regulating Valve X - None Digit 16 Digit 17 Digit 18 Digit 19 External Chilled Water & Current Limit Setpoint X - None 4-4-20mA input 5-2-10VDC input Cond Refrigerant Pressure Output Option X - None V - Condenser Water Control Output P - Condenser Pressure (%HPC) Output D - Differential Pressure Output Motor Current Analog Output (%RLA) X - None A - Motor Current Analog Output Distribution Area A - China B - Out of China C - LAR Digit 13 Insulation A - Standard Insulation B - Thick Insulation 6 RTHE-PRC002-EN

Technical Data Table 1. Rating table final Model 75 90 110 130 175 195 235 255 Water Side Condition Power Supply Evap lvg water 44F,2.4gpm/ ton Cond ent water 85F, 3gpm/ ton 220V/380V/440V (3Ph/60Hz) Cooling Capacity kw 267,3 311,2 384,8 456,9 618,3 681,9 845,8 917,9 Capacity RT 76,0 88 109,4 129,9 175,8 193,9 240,5 261,0 Power Supply kw 57,2 66,0 82,6 99,2 131,0 149,5 182,3 198,1 Running Current (220V) A 172,2 199,2 246,1 294,2 396,5 447,7 544,9 588,4 Running Current (360V) A 99,7 115,3 142,5 170,3 229,6 259,2 315,5 340,6 Running Current (440V) A 86,1 99,6 123,1 147,1 198,2 223,8 272,4 294,2 Starting Current 427/260/212 506/316/252 571/345/285 691/424/346 702/435/350 768/464/383 937/573/469 982/600/491 Capacity Modulation 30%~100% 15%~100% Compressor Qty 1 2 Starting Method Wye-delta starter Oil Charge L 8 8 11 11 17 17 17 17 Refrigerant Evaporator Condenser Type Charge kg 47 47 63 64 92 96 121 123 Water Flow Rate m3/h 41,4 48,2 59,6 70,8 95,8 105,7 131,1 142,3 Pressure Drop kpa 50,9 66,7 63,9 48,2 54,7 47,3 43,5 54,0 Water Conn. Size mm DN100 DN100 DN100 DN125 DN125 DN125 DN200 DN200 Water Flow Rate m3/h 51,8 60,3 74,5 88,5 119,8 132,1 163,9 177,8 Pressure Drop kpa 70,7 75,8 52,4 71,1 72,9 73,1 67,2 68,5 Water Conn. Size mm DN100 DN100 DN125 DN125 DN150 DN150 DN150 DN150 Net Weight kg 1890 1900 2135 2365 3485 3570 4090 4130 Operating Weight kg 2116 2129 2443 2729 3971 4051 4766 4805 Dimension Language of Control Panel Note: FF(Evap) =0.001 F ft h/btu FF(Cond) =0.0025 F ft h/btu Length mm 2927 2927 3109 3186 3648 3648 3616 3616 Width mm 916 916 918 1030 1271 1271 1393 1393 Height mm 1592 1592 1626 1663 1908 1908 2017 2017 R134a English RTHE-PRC002-EN 7

Dimensions Single Compressor Unit 75, 90, 110, 130 Ton Unit: mm RTHE 75, 95 Ton mm 110 Ton mm 130 Ton mm A 2927 3109 3186 B 916 918 1030 C 1592 1626 1663 D 2699 2755 2755 E 726 778 796 F 258 260 260 G 200 217 217 H 440 477 477 J 209 218 220 K 610 710 873 U 60 98 98 V 138 157 157 8 RTHE-PRC002-EN

Dimensions Dual Compressor Unit 175, 195, 235, 255 Tons Unit: mm RTHE 175, 195 Ton mm 235, 255 Ton mm A 3648 3616 B 1271 1393 C 1908 2017 D 3099 3107 E 747 822 F 367 318 G 249 291 H 544 606 J 227 269 K 873 855 U 101 107 V 198 200 1 Evaporator Water Inlet 2 Evaporator Water Outlet 3 Condenser Water Inlet 4 Condenser Water Outlet 5 Power Disconnect 6 Power Wire 7 Control Wire 8 Control Panel RTHE-PRC002-EN 9

Rigging Diagram Center of Gravity Model A X Y Z (mm) (mm) (mm) (mm) 75 2800 1021 775 476 90 2800 1021 775 476 110 2800 1037 767 476 130 2800 1041 854 512 Center of Gravity Model A X Y Z (mm) (mm) (mm) (mm) 175 3000 1283 845 634 195 3000 1259 882 628 235 3000 1256 920 709 255 3000 1256 920 709 10 RTHE-PRC002-EN

Unit Base Single Compressor Installation Base Diagram G3 P1 P2 P1 G1 Compressor Evaporator P4 P4 P3 Control Panel Condenser Oil Separator G4 Base hole diameters all 16mm. G2 Dual Compressors Installation Base Diagram G3 P1 P2 P1 G1 Compressor Evaporator Compressor P4 P3 Condenser Oil Separator P3 Control Panel G4 G2 Base hole diameters all 16mm. 75, 90, 110, 130 Ton 175, 195 Ton 235, 255 Ton mm(in) mm(in) mm(in) P1 63(2.48) 89(3.5) 97(3.82) P2 2558(100.68) 2858(112.52) 2858(112.52) P3 64(2.52) 45(1.77) 64(2.52) P4 807(31.78) 971(38.23) 1113(43.82) N1 1250(49.2) 1250(49.2) 1250(49.2) N2 795*(31.3*) 795*(31.3*) 795*(31.3*) RTHE-PRC002-EN 11

Electrical Connection PANEL TYPE VOLTS HERTZ 230 60 380 60 460 60 DESIGANATION CLASS QTY SIZE(A) 1F13,14 gg 2 10 1F16,17 gg 2 10 1F15 gg 1 16 1F13,14 gg 2 6 1F16,17 gg 2 10 1F15 gg 1 16 1F13,14 gg 2 6 1F16,17 gg 2 10 1F15 gg 1 16 For RTHE130 connection diagram, contact your local sales office. 12 RTHE-PRC002-EN

Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy effi cient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.trane.com.br Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifi cations without notice. 2015 Trane All rights reserved RTHE-PRC002-EN January, 2015