saving energy in comfort

Similar documents
CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

EXTRACTOR HOODS.

Lossnay RVX Fresh Series Air Ventilation

Whole Home Heat Recovery Ventilation

VRV The total solution. Integrated Climate Control

Colt CoolStream Adiabatic Cooling & Ventilation System

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

energy recovery ventilation (erv)

LOW STATIC HYDRONIC DUCTED UNIT

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Dee Fly Cube 300 and 370. Heat Recovery ventilation

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

The new generation of MVHR units - ComfoAir Q. Always the best climate for PERFORMANCE

TEVHR. Heat Recovery Ventilator

Heat Recovery Units. Heat Recovery 1

FIRE PROTECTION FIRE DAMPERS ISONE+

HIGH performance exchanger

Limited Lifetime core warranty. 5-year warranty on balance of unit.

PERFORMANCE. The new generation of MVHR units - ComfoAir Q. Always the best climate for

Ventilation & Heat Recovery. The whole house system from OMNIE

Fresh air supply systems

Colt CoolStream Evaporative Cooling & Ventilation System

Central Heating and Ventilation

Perfect Solutions for Cleaner, Fresher Indoor Air

9200 SERIES GAS FURNACES napoleonheatingandcooling.com

Dehumidifier. Instruction Manual. Model DH-320/A

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

Industrial tumble dryers

Central Heating and Ventilation

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Put the V back in HVAC

HEX390. Balanced Pressure Ventilation with Heat Recovery. for healthy indoor air

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

The New Sorption Rotary Heat Exchanger

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

ComfoAir Q. Mechanical Ventilation and Heat Recovery

Zehnder inside: A perfect indoor climate for all requirements

Ventilation. Product Information

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Fresh air supply systems

INCREASE YOUR LAB EFFICIENCY

A Waterless Trap from Des Champs Technologies LLC ELIMINATES NEED TO CONSTANTLY MONITOR DRAIN TRAPS FOR DRY OUT AND FREEZING

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

Residential-Use Lossnay

VENTILATION DESIGNED FOR CARE HOMES

Wet and dry vacuum cleaners NT 48/1 (110V)

PROOF. our story. insert pictures of things or people that tell the story. about your company

Units for suspended ceilings

DIRECT DRIVE BLOWER COILS

Installation and maintenance instructions for cabin units type vertical IDAC (V50)

PERFORMANCE. The new generation of MVHR units - ComfoAir Q. Always the best climate for

INCREASE YOUR LAB EFFICIENCY

PMFY-P20VBM-E. City Multi Indoor Product Information. Indoor Unit

COMcheck Software Version Mechanical Compliance Certificate

MINTRAC MEAT INDUSTRY ENVIRONMENT CONFERENCE WASTE HEAT RECOVERY FROM RENDERING PLANTS PRESENTED BY DEREK HENDERSON

IDEO 325 ECOWATT. Counter-flow, high-efficiency heat recovery unit IDEO 325 ECOWATT. Low noise. Heat recovery units. Wireless programmable control

Great for Rental Stackable: Constructed with interlocking ribs for stacking vertically. Great for storage as they need a minimal footprint

Operating instructions Oil condensing boiler

Screw Compressors ESM Fixed Speed & VS Variable Speed

Quality Heat Exchangers

Blarenberglaan 21 B 2800 MECHELEN Tel.: +32 (0) Fax: +32 (0)

THE CARRIER COMFORT LINE

Energy recovery unit. Projection documents

TECHNOLOGY GUIDE. :: the dawn of a new era in commercial HVAC technology. The all-new Rheem Commercial Renaissance Line featuring:

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Miniveyor. Tough Fans for Tough Jobs! NEW VAF Models now come with a Industry Leading 10 Year warranty upgrade on the fan body.

The Only Gas Furnaces Made in Canada napoleonheatingandcooling.com

The Only Gas Furnaces Made in Canada napoleonheatingandcooling.com

G Installation manual Solitude - dmev unit

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

DYNAMIC ECO, UNPARALLELED SAVINGS

INDIRECT SYSTEM FOR FROST LOCATIONS

HRV Enthalpy. Catalogue

WHHR Midi & Midi Lite

Air Conditioners 2012/2013

Fresh Air Ventilation

Fresh Air Ventilation

Compact. Efficient. TROX.

b!klimax radiant wall/ceiling system

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Mitsubishi System Technologies:

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

ACT - VS ULTIMATE ENERGY SAVING TECHNOLOGY NEW - ENERGY SAVING VARIABLE SPEED DRYERS BY FRIULAIR

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems

Transcription:

saving energy in comfort Recair introduces tomorrow s heat exchangers today RS160 - RC160 - RU160

Recair sets the bar higher again With the successful Recair Sensitive160 (RS160), Recair has been at the forefront in the field of recuperators (heat exchangers) for many years. But we continue to innovate and seek solutions that will allow you to stand out in the market. The result: the Recair Comfort160 (RC160) and Recair Ultimate160 (RU160). Two completely newly developed recuperators for the most comfortable and efficient transfer of sensible energy. The shape and outer dimensions are unchanged, so that the three versions are interchangeable. The difference is in the internal geometry. The new Recair Comfort160 achieves the same excellent efficiency at a 40% lower pressure drop. More effective than most competitors and is rightfully value for money. In a nutshell, more comfort. In the Recair Ultimate160, we have managed to improve the already unparalleled effectiveness without increasing the pressure drop by an average of 2%. In short, more energy-saving. With these two new heat exchangers, Recair is once again linking maximum effectiveness to an extremely low pressure drop. On the one hand, in response to the market demand (ECO design - label A +). On the other hand, because we consider it a challenge to constantly raise the bar ever higher. The reuse of existing energy makes an important contribution to reducing CO2 production and thus to a sustainable society. Even more energy-saving, even more comfort. 2

Ventilation Through the pursuit of safety, comfort and energy efficiency, the buildings in which we live and work are becoming more airtight. As a direct result, there is an increased focus on mechanical ventilation. Energy recovery is therefore now a permanent feature. And the technology is still being developed. Recair uses the so-called duct counterflow principle. This provides a maximum heat transfer within the smallest possible recuperator dimensions. The challenge is to use less material for continued improved performance. Material Recair chooses plastics, the correct type of material for the best heat transfer. But even in terms of hygiene, fire retardance and the draining of condensate, modern plastics are preferred. By minimising the use of material, we are showing that we take our social responsibility seriously. Figure 1: The duct counterflow design of the RS160 3

Recair Comfort vs. Recair Sensitive Excellent effectiveness at a 40% lower pressure loss The effectiveness and the pressure loss of the wellknown Recair Sensitive160 and Recair Comfort160 are included for comparison as a function of the air flow in Figures 2 and 3. Source: measurement report PL.16. WLG.285 conducted in January 2017 by the independent research institute HLK Stuttgart. The full test report can be obtained from Recair. On the Recair website, you will find the recuperator calculator, a handy programme for selecting the appropriate heat exchanger. Figure 2: Effectiveness RC160 compared to RS160 95 94 93 92 91 90 89 88 87 Effectiveness [%] 86 85 0 50 100 150 200 250 300 350 400 450 500 Flow [m 3 /h] RS160-300 RS160-400 RS160-500 RC160-300 RC160-400 RC160-500 4

Figure 3: Pressure loss RC160 compared to RS160 200 175 150 125 100 75 50 Pressure loss [Pa] 25 0 0 50 100 150 200 250 300 350 400 450 500 Flow [m 3 /h] RS160-300 RS160-400 RS160-500 RC160-300 RC160-400 RC160-500 5

Recair Ultimate vs. Recair Sensitive 2% greater effectiveness without an increase in the pressure loss The effectiveness and the pressure loss of the wellknown Recair Sensitive160 and Recair Ultimate160 are included for comparison as a function of the air flow in Figures 4 and 5. Source: measurement report PL.16. WLG.285 conducted in January 2017 by the independent research institute HLK Stuttgart. The full test report can be obtained from Recair. On the Recair website, you will find the recuperator calculator, a handy programme for selecting the appropriate heat exchanger. Figure 4: Effectiveness RU160 compared to RS160 95 94 93 92 91 90 89 88 87 Effectiveness [%] 86 85 0 50 100 150 200 250 300 350 400 450 500 Flow [m 3 /h] RS160-300 RS160-400 RS160-500 RU160-300 RU160-400 RU160-500 6

Figure 5: Pressure loss RU160 compared to RS160 200 175 150 125 100 75 50 Pressure loss [Pa] 25 0 0 50 100 150 200 250 300 350 400 450 500 Flow [m 3 /h] RS160-300 RS160-400 RS160-500 RU160-300 RU160-400 RU160-500 7

Fitting Recair recuperators come with flanges for easy and good sealing of the air inlet and outlet connection. For optimum drainage of condensed moisture, the exchange channels should be positioned horizontally or vertically, and the cooling airflow direction downwards. See figure 6 and 7. If you choose the Recair Comfort160, we advise you to put the air filter right in front of the air inlet surfaces of the heat exchanger. This is connected to good distribution of air over the exchange surface of the exchanger. No air filters are then required on the exit side of the exchanger. Guidelines for storage, assembly and use 1. Avoid direct contact with UV light. 2. Recair exchangers are designed for the buildings in which we live and work. So avoid contact with chemicals. 3. Operating temperature s: Recair exchangers may be exposed to temperatures between -20 ºC and +50 C 4. The heat exchanger may only be removed from the apparatus by carefully pulling the plastic strip fitted. 5. Cleaning with liquids or water is not required. Dust can best be removed from air inlet and outlet areas using a normal vacuum cleaner. 6. All Recair heat exchangers are checked before delivery to the customer up to a maximum leakage of 25 litres per minute at a static pressure of 250 Pa. Under certain conditions, this leakage of air may also result in some leakage of condensation. For this reason, it may help to point the air flow losing heat downwards and place a condensation trap under the whole exchanger. 7. The heat exchanger performs best when there is a perfect balance between the two air flows. The Recair Product range 8

Figure 6: Mounting orientation on the noses Figure 7: Mounting orientation For cooling purposes For cooling purposes outside-air exhaust-air return-air outside-air supply-air exhaust-air return-air supply-air (flow direction downwards) (flow direction downwards) For heating purposes return-air supply-air For heating purposes outside-air return-air exhaust-air supply-air outside-air exhaust-air (flow direction downwards) (flow direction downwards) 9

Figure 8: Product type construction type height lip condensate drain fire-retardance e.g. RC160-395 - 1-1 - 0 RC 160 with (1) with (1) with (1) 100 RS 160 up to and including 500 RU 160 without (0) without (0) without (0) 10

saving energy in comfort

Recair bv Spuiweg 28 NL-5145 NE Waalwijk P.O. Box 721 NL-5140 AS Waalwijk Tel. +31 (0)416 347 110 Fax +31 (0)416 348 926 info@recair.com www.recair.com EN 05-2017