All Chiller Products. Water Cooled and Air Cooled Modular Chillers Available in 208, 230, 460 & 575 Volts Application Ranges from 30 to 1,000 Tons

Similar documents
SHConDEMAND. True Redundancy. Heating. Cooling. Simultaneous. Efficient. Reliable

THE ULTIMATE ROOFTOP SOLUTION

Modular Chiller Systems. Application Guide

Trailblazer air cooled scroll chillers

PERFECT SOLUTIONS WATERFURNACE COMMERCIAL PRODUCTS. Water Source/Geothermal Heat Pumps

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

sm All Product Catalog

Engineered for flexibility and performance

RoofPak Applied Rooftop Systems

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Virtual Moveable Endcap II (VME II ) Product Catalog For Heat Recovery Applications

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

IPS. The Affordable Green HVAC Solution! Ideal for select service hospitality, assisted living, condos, apartments and dorms.

NQ Series Portable Chillers

Screw Water Cooled Chiller SCW210

The ultimate fresh air solution.

Maverick II Commercial Rooftop Systems 15 to 75 tons

PITTSBURG STATE UNIVERSITY. HVAC and BUILDING AUTOMATION SYSTEM STANDARDS

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

COMMERCIAL PRODUCT LINE

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

TRANQUILITY WATER-TO-WATER SERIES

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

Call us today! (800)

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Call us today! (800)

Smardt Oil-Free Chillers

PACKAGED AIR COOLED Product Data Catalog

50 Series AQUAZONE Water Source Heat Pumps

Scroll Water Cooled Chiller

Water-cooled chillers with High Speed Centrifugal Compressors

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Product Data. AquaSnap 30RAP Air-Cooled Chillers with Puron Refrigerant (R-410A) 50/60 Hz. 10 to 150 Nominal Tons (35 to 528 Nominal kw)

Product Data SEISMICOMPLIANT * AQUASNAP 30RB Air-Cooled Chillers. Features/Benefits. 60 to 390 Nominal Tons (210 to 1370 kw)

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

Air conditioning 23XRV

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

Product Chillers A P P L I C AT I O N S

Commercial and Residential Water Source Heat Pumps Boiler/Tower and Geothermal Applications

Flexible & Innovative. Cooling Solutions

Variable Refrigeration Flow Systems Overview 10/11/2016

OACS Outdoor Air-Cooled Central Chillers

Method to test HVAC equipment at part load conditions

Complete packaged and custom solutions for mechanical, plumbing, and industrial systems.

water to water heat pumps

General HVAC Recommendations

Variable refrigerant flow (VRF) systems

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

TECHNICAL. Series 18. Pump Packages

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

.2 Section Waste Management and Disposal.

PRODUCT GUIDE

Call us today! (800)

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

The Book of AERMEC NRL Sequence of Operation

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS

THE TRANQUILITY 16 COMPACT (TC) SERIES

Air Cooled Scroll Chiller / Heat Pump

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Reinventing Energy Efficiency

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

19DV Back-to-Back Centrifugal Liquid Chiller with PUREtec TM Refrigerant and Greenspeed TM Intelligence

investment in R&D, the commitment to - name.

Water-to-Water Heat Pump Product Data Catalog R-134a Modules MR010AN, MR015AN, MR020AN, MR030AN, MR040AN, MR050AN, MR070AN, MR085AN

Series R Helical Rotary Water-Cooled Liquid Chillers

Product Data. AQUASNAP 30RAP Air-Cooled Chillers with PURON Refrigerant (R-410A) 10 to 150 Nominal Tons (35 to 528 Nominal kw) a

Increase your flexibility.

Nirvana Cycling Refrigerated Dryers

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

PURESTREAM CHILL-CUBE TM BY FRIULAIR

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

TECHNICAL SPECIFICATIONS

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Now Available with PVC & Polypropylene Vent Configurations

SECTION ROTARY-SCREW WATER CHILLERS

Water Source / Geothermal Heat Pumps & Air Conditioners

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

Liebert CSU3000 Chiller

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

Product Catalog. Air-Cooled Scroll Chillers Model CGAM - Made in USA Nominal Tons (50 Hz and 60 Hz) CG-PRC017-EN.

THE FOLLOWING CHANGES/ADDITIONS TO THE ABOVE CITED SOLICITATION ARE ANNOUNCED:

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

ENGINEERING. Edition No. 13 October 2002

TRIDENT GS SERIES Central Chiller

Leadership, Innovation, Advanced Technology Synergise Here!

MODELS LIST. Nominal Capacity RT

Energy Recovery with Cooling and Heating Model ERCH

MAC-120HE-03 Air-Cooled Chiller

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

Transcription:

All Chiller Products Water Cooled and Air Cooled Modular Chillers Available in 208, 230, 460 & 575 Volts Application Ranges from 30 to 1,000 Tons

ClimaCool modular chillers. No compromises. They re not just for tight spaces, retrofits and cooling. Separate electrical feeds, independent refrigeration circuits and hydronic isolation means built-in redundancy.

Wide variety of products and configurations to fulfill your application demands. ClimaCool is dedicated to providing flexible configurations to meet all your application needs, no compromises. These modular chillers are utilized in a wide variety of heating, cooling, heat recovery, heat pump and simultaneous heating and cooling heat pump and heat recovery commercial and industrial applications. So whether the need is a dedicated chiller for off peak loads, a heat recovery chiller, a truly redundant simultaneous heating and cooling plant or more, the following fundamental design features are integral to the product to provide a complete climate control solution. No compromises! Compact Small footprint reduces installation cost and restrictions on placement. CoolLogic Control System CoolLogic provides complete system integration for ultimate chiller performance. It allows for control of modules via two-conductor shielded cable and interfaces with native BACnet, LonWorks, Modbus and N2 communication. The CoolLogic Control System governs all top level events, timing and compressor staging and allows operator interface for all levels of setting and retrieving data. It maintains precise temperature control for cooling, heating, heat recovery and simultaneous heating and cooling applications to ensure the highest building comfort for occupants. Energy Efficient All ClimaCool modules are designed to exceed ASHRAE 90.1 minimum efficiency requirements. Environmentally Friendly Micro charge of non-ozone depleting R-410A refrigerant offers better efficiency, higher capacity and utilizes superior synthetic lubricants for longer compressor life. Expandable Modular design allows for incremental system capacity to accommodate future growth. Lower Installation Costs Maneuverable through existing doorways and freight elevators via fork lift or pallet jack which removes the need for demolition and/ or reconstruction. Retrofit Friendly Compact design shrinks mechanical room and building footprint. This also allows modules to fit through existing doors eliminating the need for demolition and reconstruction. Service Friendly Design allows easy access to major components making the models fully serviceable and maintainable without removal of a module from the chiller bank or disassembly of headers. Simple Easy connect design simplifies installation, service and controls. Sustainable Based on application, ClimaCool chillers can help meet LEED prerequisites and gain significant points required for LEED certification. True Redundancy Separate module electrical feeds and dual independent refrigeration circuits provide true system redundancy. LEED categories satisfied by ClimaCool systems: Enhanced Commissioning and Measurement and Verification CoolLogic Control System provides maximum flexibility with BAS interface. Enhanced Refrigerant Management Micro charge of chlorine-free and non-ozone depleting refrigerant. Optimized Energy Performance Exceeds ASHRAE 90.1 minimum efficiency requirements. Thermal Comfort Precise required heating and cooling ensures the highest comfort for building occupants.

Water Cooled & Geothermal Source Water Cooled, Model UCW Designed for major application flexibility and expandability to accommodate current and future needs. This system grows with the building requirements and offers a simple design for easy initial and future installation. Reaches efficiencies up to 16.3 EER at full-load and up to 20.4 EER at part-load (IPLV), exceeding ASHRAE 90.1 minimum efficiency requirements. The model UCW has earned AHRI certification, an assurance of this product s performance. Tonnages: 30, 50, 70, 85 Configurations: From 30-1,000 tons per bank Dimensions: 30, 50, 70 tons: 34 1/4 W x 65 1/8 H x 55 1/2 D 85 tons: 34 1/4 W x 72 H x 67 D High Temperature Chiller/Heater Heat Pump, Model UCH The high temperature heat pump utilizes a refrigerant reversing valve to provide heating and cooling operation compatible with boiler/tower and geothermal systems. The heat pump system reaches efficiencies up to 16.3 EER, exceeding ASHRAE 90.1 minimum efficiency requirements. Tonnages: 30, 50, 70, 85 Configurations: From 15-1,000 tons per bank Dimensions: 30, 50, 70 tons: 34 1/4 W x 65 1/8 H x 55 1/2 D 85 tons: 34 1/4 W x 72 H x 67 D High Temperature Chiller/Heater Heat Recovery, Model UCH The high temperature heat recovery can be utilized for heating and cooling operations and is compatible with boiler/tower and geothermal systems. Heat recovery can provide hot water, while also producing chilled water. The heat recovery module can reach combined efficiencies of up to 25 EER. Tonnages: 30, 50, 70, 85 Configurations: From 15-1,000 tons per bank Dimensions: 30, 50, 70 tons: 34 1/4 W x 65 1/8 H x 55 1/2 D 85 tons: 34 1/4 W x 72 H x 67 D Water Cooled Compact Screw, Model UGW Utilizes the most advanced technology compact quiet screw compressor, optimized for water cooled applications and R-134a non-ozone depleting refrigerant. Proven rotary screw compressor technology, factory provided variable frequency drive and stainless steel brazed plate heat exchangers provide ultra-low maintenance cost and maximum reliability. Option available for shell and tube condenser. Tonnages: 80 Configurations: From 80-640 tons per bank Voltages: 208, 230 and 460 Dimensions: 34 3/4 W x 78 H x 75 D

Buck Institute Novato, CA

PNC Bank Toledo, OH

Air Cooled Packaged Air Cooled, Cooling Only, Model UCA The ultimate in design flexibility with back-to-back and end-to-end configurations. This allows combining tonnages to obtain specific project turndown for required bank capacity. The packaged air cooled offers a minimum efficiency of 10.0 EER at fullload, exceeding ASHRAE 90.1 minimum requirements. Provides low operating noise levels with high efficiency, variable speed EC condenser fans which includes integral head pressure control. The UCA, cooling only model has earned AHRI certification, an assurance of this product s performance. Tonnages: 20, 30, 50, 70 Configurations: From 20-420 tons per bank Dimensions: 20, 30 tons: 83 3/4 W x 84 H x 39 3/4 D 50, 70 tons: 83 3/4 W x 99 1/8 H x 80 1/2 D Remote Air Cooled, Model UCR Each module is designed to be field piped to a matching remote air cooled or evaporative condenser and eliminates the need for a cooling tower. This helps preserve space as well as lowering building water usage and treatment needs. Design offers efficiencies up to 10.9 EER at full-load and up to 17.5 EER at part-load (IPLV) exceeding ASHRAE 90.1 minimum efficiency requirements. Tonnages: 30, 50, 70, 85 Configurations: From 30-400 tons per bank Dimensions: 30, 50, 70 tons: 34 1/4 W x 65 1/8 H x 55 1/2 D 85 tons: 34 1/4 W x 72 H x 67 D Free Cooling, Model UCF Directly coupled to packaged air cooled chiller bank. Includes glycol free cooling coils, high efficiency, variable speed EC condenser fans with integral head pressure control and acoustical design providing low operating noise levels, two position motorized water isolation valve, 3-way bypass valves and fully integrated controls. Tonnages: 30, 70 Dimensions: 30 tons: 83 3/4 W x 84 H x 39 3/4 D 70 tons: 83 3/4 W x 99 1/8 H x 80 1/2 D Packaged Air Cooled Heat Pump or Heat Recovery, Model UCA Designed to provide a quiet, serviceable and extremely efficient system that will offer years of reliable operation. High efficiency design offers a minimum of 10.0 EER at full-load, exceeding ASHRAE 90.1 minimum efficiency requirements. Includes high efficiency, variable speed EC condenser fans with integral head pressure control and acoustical design providing low operating noise levels. Modules can be configured to provide project turndown and capacity requirements from 20 420 tons. Tonnages: 20, 30, 50, 70 Configurations: From 20-420 tons per bank Dimensions: 20, 30 tons: 83 3/4 W x 92 H x 39 3/4 D 50, 70 tons: 83 3/4 W x 99 1/8 H x 80 1/2 D

on DEMAND SIMULTANEOUS HEATING AND COOLING 95B 059N01 SHC ondemand Simultaneous Heating and Cooling Heat Pump and Heat Recovery, Model UCH Achieve cooling efficiencies up to 25 EER and heating efficiencies up to 5 COP to potentially lower system energy costs by more than 50% when compared to traditional boiler/chiller systems. Each module can be indexed for heating and/or cooling ondemand regardless of its position in the bank, to precisely match building loads and provide optimum module/ compressor run time equalization. Piping connection flexibility for hot, cold and source water loops allows same or opposite end configurations based on mechanical room needs. Tonnages: 15, 25, 30, 50, 70, 85 Configurations: From 15-1,000 tons per bank Heat Pump Dimensions: 15, 25, 30, 50, 70 tons: 34 1/4 W x 78 H x 55 1/2 D 85 tons: 34 1/4 W x 84 7/8 H x 67 D Patent Pending Heat Recovery Dimensions: 15, 25, 30, 50, 70 tons: 34 1/4 W x 78 7/8 H x 67 3/4 D 85 tons: 34 1/4 W x 82 7/8 H x 79 1/4 D Packaged Air Cooled Simultaneous Heating and Cooling Heat Pump, Model UCA Reduce energy consumption and the environmental impact of your heating and cooling equipment by harnessing energy that is already being produced but not used. Includes high efficiency, variable speed EC condenser fans with integral head pressure control and acoustical design providing low operating noise levels. The packaged air cooled SHC ondemand provides hot water, as high as 135 F, while offering a minimum cooling efficiency of 10.0 EER with typical heating efficiencies around 3.0 COP. NEW Tonnages: 20, 30, 50, 70 Configurations: From 20-420 tons per bank Dimensions: 20, 30 tons: 83 3/4 W x 84 H x 39 3/4 D 50, 70 tons: 83 3/4 W x 99 1/8 H x 80 1/2 D Patent Pending Simultaneous Heating and Cooling Water to Water Heat Recovery Chiller with Integral Air Cooled Condenser Take advantage of the tremendous energy savings of water to water heat recovery chillers in an outdoor design. Each module contains individual brazed plate evaporator and brazed plate condenser for maximum chilled water and hot water output in heat recovery mode. Modules will optimize their output by operating in the water to water heat recovery mode. Integral air cooled fans will only operate when there is an unequal cooling or heating building load for the operating modules. Fans act so that heat can be added or taken out of the refrigerant loop eliminating the need for geothermal well fields or other source/sinks. Tonnages: 20, 30, 50, 70 Configurations: From 20-420 tons per bank Dimensions: 20, 30 tons: 83 3/4 W x 84 H x 39 3/4 D on 50, 70 tons: 83 3/4 W x 99 1/8 H x 80 1/2 D DEMAND SIMULTANEOUS HEATING AND COOLING

Why throw away the heat? ClimaCool chillers provide heating, cooling, heat recovery and heat pump technology in each module. Leading you to a lower cost of ownership.

Modular Chiller Skid Options Configurable up to 1,000 tons Application flexibility to fit many configurations Air or Water Cooled Simultaneous heating and cooling Pump packages Chiller plant controls Lower contruction cost Chiller plant rigs in pre-piped skid reducing rigging time and cost All piping and electrical done off site, simplifying the connections at the building site, and reducing the construction time and cost for the chiller plant Preassembly reduces chiller plant footprint minimizing architectural screening (if required for the building site) One source for controls, simplifying and reducing cost for startup and commissioning Easy building automation system integration

Options to suit every need. Automatic CS Series Strainer Package Field installed, high quality, low maintenance stainless steel filtration systems with 60 or 80 mesh stainless steel screens will reduce operating costs and prevent nuisance condenser issues. Strainer package can be equipped with optional pressure differential alarm and automatic time flush. Condenser Water Head Pressure Regulating Control Factory installed motorized condenser water valves provide head pressure regulation for low entering condenser water temperature applications (less than 60 F). Hail Guards Factory or field installed 18 gauge galvanized steel louver panels with powder coat paint finish for outdoor element protection. (Packaged Air Cooled) Harsh Environment Factory installed coil coating for outdoor element protection. (Packaged Air Cooled) Heat Pump Factory installed reverse cycle heating and cooling operation compatible with boiler/tower and geothermal systems. Heat Recovery Factory installed to provide hot water, while simultaneously producing chilled water for the chiller system. (Not available on Water Cooled Compact Screw) Hot Gas Bypass Factory installed on both circuits allowing unit operation below the minimum step of unloading. Low Ambient to -20 F Factory installed variable speed fan control for all condenser fans provides optimum head pressure control. Liquid receivers and flood-back head pressure control valves are provided for all refrigerant circuits. (Air Cooled Cooling Only) Manual Strainers Field installed to utilize Y-style and basket strainers of cast iron 200 psi or carbon 275 psi with 60 mesh stainless steel screens to increase efficiency and ensure long equipment life. All strainers are field installed external to the chiller bank for ease of service. Pressure Differential Flow Sensor Field installed to prevent operation of the chiller without sufficient water flow to the evaporator and/or condenser. Pump Manual Strainers module and standby centrifugal pumps in a lead/lag configuration coupled to the common chiller header and controlled through the CoolLogic Control System. (Packaged Air Cooled) Simultaneous Heating & Cooling Factory installed to include four (4) headers for Packaged Air Cooled or six (6) headers for Water Cooled and integral motorized valves for indexing module for heating or cooling operation. (Not available on Water Cooled Compact Screw) Water Header Bypass A field installed water header bypass may be utilized to prevent deadheading the pump. Water Isolation Valves and Individual Heat Exchanger Flush Ports Factory installed providing module isolation for maintenance and individual cleaning of evaporator and/or condenser heat exchangers. This is accomplished without increasing unit or bank dimensions. Individual heat exchangers can be backflushed/ cleaned while adjacent modules continue normal operation. Optional choice of integral manual or motorized valves includes ¾ fill and flush valves. Weatherproof Enclosure NEMA 4 enclosures for CoolLogic Master Panel.

Education Market Applications Briarwood Elementary Hospitality Industrial Ditch Witch Multi-Family Marlborough Apartments Business Services Data Centers Government Great Northern Hotel Ansys, Inc. World Trade Center Birch Bay Courthouse Healthcare Retail Central Park Tower Public Statue of Liberty Northeast Georgia Health Systems Contact your local ClimaCool representative or visit our web site at www.climacoolcorp.com to find out more about the heating and cooling solutions that may fit your application needs. on DEMAND SIMULTANEOUS HEATING AND COOLING 15 S. Virginia Oklahoma City, OK 73106 Phone: 405.815.3000 Fax: 405.815.3052 www.climacoolcorp.com C U L U L ClimaCool works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimaCool s Customer Service Department at 405.815.3000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimaCool s opinion or commendation of its products. AHRI Certified is a trademark of the Air Conditioning, Heating, and Refrigeration Institute. USGBC and related logo is a trademark owned by the U.S. Green Building Council and is used with permission. Doc #: APB071013 ClimaCool Corp. 2018 Rev: 4/18