ECO ETS Electromotive drive

Similar documents
FDC/ -B. Product information SYSTEM TECHNOLOGY FOR THE DOOR ECO

1 Door closers. Door closers Technical information. The global leader in door opening solutions.

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

DC340 Rack and pinion door closer with guide rail or link arm

DC300 Rack and pinion door closer with link arm

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

record DFA 127 The silent, energy-saving automatic swing door operator

Security Door Closer Safe and secure by design. ASSA ABLOY Door Controls

Universal operator - easy to install, reliable in operation

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

ABLOY FIRE DOOR CLOSING SYSTEMS

DC300 Rack and pinion door closer with link arm

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

DFA 127. record DFA 127 automatic drive system for swing doors. record your global partner for entrance solutions

ABLOY DOOR CLOSERS Excatly the right choice

Line Smoke Detector LRMX

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

DICTATOR Hold-Open Systems for Hazardous Areas

SCHÜCO ALUMINIUM DOOR SYSTEM ADS 70

DC200 Rack and pinion door closer with link arm

Installation and Operation Manual

STA 21. record STA 21. record system 20 technologies for light to medium-heavy applications. record your global partner for entrance solutions

ABLOY DOOR CLOSERS Exactly the right choice

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

LC2200 Level Controller Installation and Maintenance Instructions

Automatic Sliding Door Systems

Cam action door closer system DORMA TS 93

TS 93. Cam action door closer system in Contur Design

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor

GEZE SAFETY TECHNOLOGY. GEZE SecuLogic EMERGENCY EXIT SYSTEMS SAFETY ON ESCAPE AND RESCUE ROUTES BEWEGUNG MIT SYSTEM

Installation and Operating Instructions

GEZE SAFETY TECHNOLOGY. GEZE SecuLogic EMERGENCY EXIT SYSTEMS SAFETY ON ESCAPE AND RESCUE ROUTES BEWEGUNG MIT SYSTEM

All by design. ASSA ABLOY Door Controls

Sensing light curtain as per DIN 18650/EN 16005

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Conventional Fire Detection

TS 93. Cam action door closer system in Contur Design

Automatic swing door solutions. We make access in life smart and secure.

Ionisation single-tube smoke detector for duct mounting

01_TT_TST_04_61_GB.qxd :30 Uhr Seite 4. Door Closers and Door Control Systems

5900 SERIES Low Energy Power Operator

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

For architects, builders and planners. The new way to convey energy and signals. Hahn Türband 4 Inductio.

ED 100 ED 250. Swing door drives

Automated Entrance Accessories. ADA compliant door control without compromise

GEZE AUTOMATIC DOOR SYSTEMS GEZE ACTIVATION DEVICES AND SENSOR SYSTEMS PERFECTLY CONTROLLED AUTOMATIC DOOR DRIVES BEWEGUNG MIT SYSTEM

Reflective Optical Beam Smoke Detector User Guide

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Passive infrared ceiling sensor

NEW. TS 98 XEA: Licence to close. Slide channel door closer TS 98 XEA

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air

High performance door Albany RR3000 Series. ASSA ABLOY Entrance Systems

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Environmental simulation chamber for complex alternating climate profiles

INPUT / OUTPUT MINI MODULES

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

SAFGLASS Sliding Systems for glass doors

Carey Automatic Door, LLC 1 - PNEUMATIC OPERATOR FOR SINGLE SWINGING DOOR

EBDSPIR-PRM-LV Product Guide

On the job around the clock 24/7: Fire detection systems

Sensing light curtain as per DIN 18650/EN 16005

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

The CAB & DAB Air Curtains

LUX Hardwired - Installation Notes

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

System 800 Addressable Fire Detection & Alarm System

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

ABLOY DOOR CLOSERS Excatly the right choice

Emergi-Lite Orbis detectors

Products no longer available

Air Shower with Integrated Air Handling Unit

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

ELECTRIC LOCKS. Europrofile range

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

FLEXIBLE DOOR SOLUTIONS FOR VARIOUS BUILDING TYPES. KONE automatic sliding doors

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

The all-in-one airlock. Models: SkySas BA9S, SkySas BA9L. Manual Attack Resistance. Recyclable product. Ballistic Resistance.

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

5900 Series X-in Low Energy Power Operator

MINERVA MZX125 Digital Addressable Fire Detection System

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

Pedestrian Swing and sliding doors. Accessories

2409/2900. Fire Guard

INSTALLATIONN GUIDE & OPERATION MANUAL

Vigilant LED Based Obstruction Lights

Concealed cam-action door closer system DORMA ITS 96

SIMPLY THE WIDEST FOLDING DOOR. FFT FLEX Green. Maximum clear opening widths and best thermal separation.

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

EFBW series - BiWire Ultra control panel

Radio fire warning panel SRC 3000

Smoke and Fire Curtains

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Multifunctional Gate Box MGB. More than safety.

Transcription:

ECO ETS Electromotive drive 1

ETS 73 - System highlights 1. Force - up to 250 kg / EN 7 The ECO ETS has a strong power unit that safely opens and closes door leafs up to 250 kg in weight and up to 1.600 mm in width (EN 7) This provides secure automation for external doors that may experience strong wind loads as well as heavy fire protection doors The robust chassis and gear unit combined with the open stop secures the ETS against the manual application of force, e.g. improper use or vandalism. In addition to these parameters, the ETS, with its new electromotive power unit, is extremely quiet and has a well engineered, harmonious movement. It is these properties that make the ETS such an all-rounder for public buildings, hospitals, elderly homes and clinics. 2. Model with slide rail on hinge side and hinge-opposite side / also fire protection! The ETS can be combined as follows: Lintel installation with standard arm, hinge-opposite side push Lintel installation with slide rail, hinge-opposite side push Lintel installation with slide rail, hinge side pull Door assembly with slide rail (for special applications) All mounting options are available in both standard and fire protection variations. This gives planners and architects a comprehensive range of design options with sliding rails for all assembly applications, whether that is hinge side or hinge-opposite side, T0 or fire or smoke protection! For door manufacturers it also opens up new possibilities for the production of fire or smoke protection doors. 3. Low energy and full power in a single power unit The ETS can use the same power unit for 2 functions: Low energy and full power The full power setting enables, for example, heavy doors in frequent use in public buildings to be automated with fast movement sequences. This requires the use of sensor strips to monitor the movement area. The low energy setting is specially designed for private homes or office and working areas with less frequent public access. Sensor strips are not needed here, but there are restrictions on door weight and speed of movement. Each type of operation is easy to set on site, and can therefore also be altered at a later date. Leaf weight in kg 250 200 150 100 50 0 850 900 950 1000 1050 1100 1150 1200 1250 1300 1350 1400 1450 1500 1550 1600 Leaf width in mm 2

ETS 73 - System highlights 4. Fire and smoke protection / Inverse function / Interlock function The ETS model ETS 64-R is approved as a hold-open device for fire and smoke protection doors. In combination with a lintel switch it triggers the fire protection closer in the case of an alarm (smoke activated) or power failure. The inverse function is specially designed for removing smoke from a building. Here the fire or smoke protection function is reversed when an alarm is activated, i.e. the door opens automatically to allow the smoke to escape. This is also the case in the event of a power failure. The inverse function is pre-installed in the ETS and therefore can also be set on site. The interlock function regulates the complex automation sequences of double doors in safety areas (controlled and directional flow control). 5. Wind load compensation The wind load regulation serves to adapt the smooth operation of external doors to varying air pressure conditions (up to gale force 9). The power unit identifies any brief increase in wind load (e.g. strong gusts). The controls then calculate the additional power required to strengthen or brake the power unit so that the leaf can continue to move almost without interruption. The strength of the wind load depends on the size of the door and the type of arm used. For outward opening doors in areas subject to high wind loads on a regular basis (e.g. coastal areas) the normal arm (hinge-opposite side push) should be used. 3000 2900 2800 2700 2600 2500 2400 2300 2200 2100 80 km/h (320 Pa) 70 km/h (245 Pa) 60 km/h (180 Pa) 50 km/h (125 Pa) 45 km/h (100 Pa) 40 km/h (80 Pa) 2000 800 900 1000 1100 1200 1300 1400 1500 1600 6. Simple assembly and service The ETS has a simple, user-friendly setting function for all parameters. This is provided by the display panel with joystick function on the control board. A menu style checklist makes it easy to configure the initial operation on site. All parameters can also be configured at a later date or to suit any new operational requirements (password protected) with no need for an external control module or laptop. This makes the ETS particularly interesting for assembly and service companies, who do not want to have to use a specific external programming device or special software for every type of drive. 3

EN 1155 EN 16005 Performance criteria ETS 73 ETS 64-R Closing force Size according to EN 3 7 4 6 Door width Internal doors 1.600 mm Fire protection doors 1.400 mm Dimensions Length in mm Depth in mm Height in mm 690 120 95 690 120 95 Hinge side with slide rail (pull) Hinge-opposite side with slide rail (push) Hinge-opposite side with standard arm (push) DIN-Left / DIN-Right Opening speed adjustable (inc. mounting plate) 26 according to EN 689 165 (185) 95 (variable adjustment) 120 623 38,5 Dimensions: ETS with slide rail Bei gefälzten den langen Zapfen einsetzen (im Lie In thetüren case ofbitte rebated doors please use the long pins (Dargestellt mit langen Zapfen) (included in delivery) 120 689 Closing speed Hold-open time adjustable 0-60s Driving power adjustable Max. door opening angle 170 95 adjustable with mains operation, fixed if there is a power failure 105 Tested according to EN Dimensions: ETS with standard arm EN 1155 EN 16005 Suitable for fire and smoke protection doors - certified according to EU guidelines Yes - No Optional ECO ETS Steel door n Wooden door Profile frame door Motorised opening controlled closing The new ETS from ECO is a powerful, silent, electromotive drive system for heavy internal and external doors up to 250 kg. Models and functions: Slide rail push (hinge-opposite side) and pull (hinge side) Standard arm push (hinge-opposite side) 1 and 2 leaf systems with total coverage Adjustable closing force (with power-free function) Simple operation via button in side panel (Automatic - Continuous - Hand - Exit - Night) Push + Go function, gentle response Impact force and open position adjustable Impact delay adjustable (motor lock, closing sequence) Plug + Play, operation of functions with LCD display. Low energy operation without security sensors 4

ETS EN 1155 EN 16005 s Drive without arms Colour ETS Colour ETS 73 Stainless steel 358501548011000 ETS 64-R Stainless steel 358501548021000 ETS 64-R (Hinge-opposite side push) Stainless steel 358501548023000 GS-ETS Stainless steel 358501547120010 Standard arm for ETS (up to 250 mm recess depth) Colour NG-ETS Stainless steel 358501547110020 Please order safety elements, which offer additional protection for clamping points and two-way traffic, with infrared sensor strips in accordance with DIN 18650 and EN 16005! More information can be found on page 7. 5

ETS EN 1155 EN 16005 Installation drawing ETS 73 single leaf 217 207 226 120 120 62 (86) 217 207 226 140 280 280 76 62 (86) 40 (64) 161 (185) ETS 73 Head mounting hinge-opposite side with slide rail (push) 120 217 207 226 53 76 170 76 161 (185) 140 280 280 13 ( 37) ETS 73 Head mounting hinge side with slide rail (pull) FD 20 Kopfmontage Bandseite mit Gleitschiene For rebated doors please use the long pins (included in delivery) Bei gefälzten Türen bitte den langen Zapfen einsetzen (im Lieferumfang enthalten) 31... 42 358 45 ETS 73 Head mounting hinge-opposite side with standard arm (push) FD 20 Kopfmontage Bandgegenseite mit Normalgestänge 6

ETS EN 1155 EN 16005 Installation drawing ETS 73 double leaf 120 Hinge distance = min. 1.400 - max. 3.200 mm (86) 37 120 217 207 226 226 207 217 62 (86) 161 (185) 140 280 280 280 280 140 40 (46) ETS 73 Head mounting hinge-opposite side with slide rail (push) 120 217 207 226 53 76 170 76 161 (185) ( Hinge distance = min. 1.400 - max. 3.200 mm 217 207 226 226 207 217 140 280 280 280 280 140 62 1 ) 3 ETS 73 Head mounting hinge side with slide rail (pull) For rebated doors please use the long pins (included in delivery) Hinge distance = min. 1.400 - max. 3.200 mm 226 207 217 42 31... 358 45 45 358 ETS 73 Head mounting hinge-opposite side with standard arm (push) 7

ETS EN 1155 EN 16005 Installation drawing ETS 64-R single leaf 130 25 (49) 110 140 280 280 53 (77) 40 (64) 161 (185) ETS 64-R Single leaf head mounting hinge-opposite side with slide rail and mounting plate Reference dimension - all further holes must be drilled according to the specifications of the door or profile manufacturer. All information in brackets can vary according to the clamp (clamp-13 or clamp +20) 130 14...25 110 358 45 62...73 31...42 170 ETS 64-R Single leaf head mounting hinge-opposite side with standard arm and mounting plate Reference dimension - all further holes must be drilled according to the specifications of the door or profile manufacturer. For rebated doors please use the long pins (included in delivery) All information in brackets can vary according to the clamp (clamp-13 or clamp +20) 130 52 (76) 110 140 280 280 26 ( 50) 13 ( 37) 161 (185) ETS 64-R Single leaf head mounting hinge side with slide rail and mounting plate Reference dimension - all further holes must be drilled according to the specifications of the door or profile manufacturer. For rebated doors please use the long pins (included in delivery) All information in brackets can vary according to the clamp (clamp-13 or clamp +20) 8

ETS EN 1155 EN 16005 Installation drawing ETS 64-R double leaf Hinge distance = min. 1.500 - max. 2.800 mm (EN 4 - EN 6) 130 25 (49) 110 140 280 280 280 280 140 130 25 (49) 53 (77) 40 (64) 161 (185) ETS 64-R Double leaf head mounting hinge-opposite side with slide rail and mounting plate Reference dimension - all further holes must be drilled according to the specifications of the door or profile manufacturer. For rebated doors please use the long pins (included in delivery) All information in brackets can vary according to the clamp (clamp-13 or clamp +20) Hinge distance = min. 1.500 - max. 2.800 mm (EN 4 - EN 6) 130 14...25 110 358 45 45 358 130 14...25 62...73 31...42 170 ETS 64-R Double leaf head mounting hinge-opposite side with standard arm and mounting plate Reference dimension - all further holes must be drilled according to the specifications of the door or profile manufacturer. For rebated doors please use the long pins (included in delivery) All information in brackets can vary according to the clamp (clamp-13 or clamp +20) Hinge distance = min. 1.500 - max. 2.800 mm (EN 4 - EN 6) 130 52 (76) 110 130 140 280 280 280 280 140 52 (76) 26 ( 50) 13 ( 37) 161 (185) ETS 64-R Double leaf head mounting hinge side with slide rail and mounting plate Reference dimension - all further holes must be drilled according to the specifications of the door or profile manufacturer. For rebated doors please use the long pins (included in delivery) All information in brackets can vary according to the clamp (clamp-13 or clamp +20) 9

ETS 73 - Cable plan single leaf 10 25 max ø30 7 1 2 3 54 8 4 5 6 9 Pos. Drawing Cable Comment 1 ECO ETS 73 Mounting hinge side or hinge-opposite side 2 Normal arm or slide rail (push) Mounting on door leaf hinge side or hinge-opposite side 3 Sensor strip set for hinge or hinge-opposite side with stop or reverse function supplied by ECO For internal cabling the cable is installed in advance, otherwise the cable is installed externally with cable transition (black). 4 Large button internal 4 x 0,6 mm² oder 4 x 0,8 mm² Concealed socket, cable installed in advance 4.1. Large button external 4 x 0,6 mm² oder 4 x 0,8 mm² Concealed socket, cable installed in advance 5 Emergency button Door Closed (optional) 4 x 0,8 mm² Concealed socket, cable installed in advance 6 Bedix switchpoint 4 x 0,8 mm² Concealed socket, cable installed in advance 7 Power cable 230V 3 x 1,5 mm² 50 Hz, 10 A 8 E-opener 24V 4 x 0,6 oder 0,8 mm² Cable installation in advance inside the frame 9 Control circuit contact supplied by ECO Cable installation in advance inside the frame 10 Radar (internal) supplied by ECO Cable installation in advance (or concealed) 10.1 Radar (external) supplied by ECO Cable installation in advance (or concealed) 10

ETS 73 - Cable plan double leaf 25 max ø30 max ø30 25 54 3x1,5mm² (50Hz, 10A) 3x1,5mm² (50Hz, 10A) 54 10 13 1 1.1 7 2 2 3 3.1 GF SF 12 12 6 5 4 8 9 11 Pos. Drawing Cable Comment 1 ECO ETS 73 (Master- GF) 3 x 1,5 mm² (50 Hz, 10 A) Mounting hinge side or hinge-opposite side 1.1 ECO ETS 73 (Slave - SF) 3 x 1,5 mm² (50 Hz, 10 A) Mounting hinge side or hinge-opposite side 2 Standard arm or slide rail Mounting on door leaf hinge side or hinge-opposite side 3 Sensor strip set GF Cable from ECO, Installed to Master - GF 3.1 Sensor strip set SF Cable from ECO, installed to Slave - SF internal cabling in advance, otherwise cable installed externally with cable transition internal cabling in advance, otherwise cable installed externally with cable transition 4 Large button internal 4 x 0,6 oder 0,8 mm² Concealed socket, cable installed in advance 4.1 Large button external 4 x 0,6 oder 0,8 mm² Concealed socket, cable installed in advance 5 Bedix 4 x 0,6 oder 0,8 mm² Concealed socket, cable installed in advance 6 alternative operating elements 4 x 0,6 oder 0,8 mm² Concealed socket, cable installed in advance 7 ECO dual locking, or E-opener in SF bei E-Öffner - 4 x 0,6 mm² Cable installed in advance in the frame 8 E-opener 24V 4 x 0,6 oder 0,8 mm² Cable installed in advance in SF 9 Control circuit contact 4 x 0,8 mm² Cable installed in advance in SF 10 Radar (internal) 4 x 0,8 mm² Cable installed in advance (or concealed) 10.1 Radar (external) 4 x 0,8 mm² Cable installed in advance (or concealed) 11 internal cable transition for E-opener and smoke protection Optional, in advance RSK 12 internal cable transition for sensor strips Optional, in advance 13 CAN cable for control of closing sequence regulation for T0 doors supplied by ECO Cable installed in the frame (in advance) or in the continuous drive cladding (optional) 11

ETS - Check list Check list orders - ETS Fire protection leaf Leaf width Bedix Button Radar Sensor strips Finger protectiocy off Emergen- E-opener blind RSK Pos. Type of arm yes no 1 2 in mm yes no internal external internal external Hinge side hinge opposite side yes no yes no yes no Hardware Drive Slide rails Standard arms Operating elements Bedix Button GFT Radar Security elements Sensor strips Finger protection Emergency off Accessories locks E-opener RSK Motor driven locks 12

Fair Stuttgart, Germany ECO Schulte Global confidence. All over the world, wherever people value quality, reliability and safety, ECO Schulte products have been in use for many years. The combination of functionality and design have brought the ECO systems international recognition. At this point we would like to say thank you for the global confidence that has been shown in ECO Schulte products. We see this as a challenge to continue to satisfy the demands of our customers and the market through constant development and carefully tailored production. 13

ETS Accessories Smoke switch ORS 142 W - Standard Function: Scattered light Alarm level smoke acc. to EN 54, Part 7 Release temperature: 70 ± 5 C Supply voltage: 18 to 24 V DC Power input: at 28 VDC Max. 22 ma Degree of protection: IP 42 Ambient temperature: -20 to +75 C 35 127 EN 54 ORS 142 W - Standard Smoke switch ORS 142 W - Standard 355000572 Cover for ORS 142 W 3543007350002 36 ORS 142 ceiling smoke switch Smoke detection: according to EN 54, Part 7 Temperature: 70 C Operating voltage: 18 28 V DC Current power: at 28 V DC, rest 22 ma, Alarm 11 ma, Fault 16 ma, Relay contact: Opener Switching voltage: 30 V DC Switching current: 1A Switching power: 30 W Protection type: IP 42 Temperature range: -20 C bis +60 C EN 54 Ceiling smoke switch Colour / Material ORS 142 White RAL 9010 350200000052100 HAT 02 Hand-operated button for mounting in dry environments, for the manual activation of hold-open mechanisms in accordance with DIBt guidelines Mounting: On-wall / concealed Relay contact: Opener Switching voltage: 30 V DC Switching current: Max. 1 A Protection type: IP 20 Hand-operated button HAT 02 356500143 14

ETS Accessories Finger protection blind (FSR) To prevent squashing or pinching between the door and the frame on the hinge-opposite side. Can be mounted retrospectively Finger protection blind Total height FSR 1.920 mm 3504710132 Relay board (RSP) Relay board of the ETS. 4 freely configurable relays for controlling acoustic or optic transmitters or to signal the door status (e.g. open, closed, locked, fault) Can be mounted retrospectively Relay board RSP 350548215 Dead bolt switch contact (RSK) Dead bolt switch contact for installation in the closing plate. Switches the power unit off as soon as the lock is mechanically locked. This prevents a failure of the power unit when locking. Includes 6 m cable. Dead bolt switch contact Dead bolt switch contact (RSK) 35851RK1335U06 15

ETS Accessories Standard opener with smoke protection approval Door openers with red connection blocks are designed for 12 or 24 Volt (each +/- 15%) continuous operation. Standard opener with smoke protection approval A-5002-B A-5002-FB (Latch guide) 35851A5002B 35851A5002FB Fire protection door opener Door openers with red connection blocks are designed for 12 or 24 Volt (each +/- 15%) continuous operation. Fire protection door opener FT-502-B FT-502-FB (Latch guide) 35851FT502B 35851FT502FB Motor driven locks FlipLock drive Multi-point locking with panic function, mechanically self-locking 3 patented latches + 3 long bars Motor unit with integrated control Pin and lock variations available FlipLock access Multi-point locking with panic function, mechanically self-locking 3 patented latches + 3 long bars Motor unit with external control Pin and lock variations available Evaluation of all contacts (potential-free) Motor driven locks FlipLock drive FlipLock access On request On request 16

ETS Accessories Operating console D-BEDIX for ETS With the D-BEDIX, the different types of operation can be chosen directly. In addition, the most important door settings can be implemented with ease. The display clearly shows the types of operation, menu settings and possible faults. Operating console D-BEDIX 358500063514215 Flip switch (GFT) Funtion door OPEN. Operating voltage 250 VAC / 30 VDC Current power max. 10 AAC / 2 ADC Protection type IP 40 225 x 83 mm Flip switch Colour GFT platinum grey RAL 7036 358506443210000 Remote control for ETS For the remote control of the motor, for disabled-friendly opening of the door. Remote print for easy insertion on the control board of the ETS. Handheld radio transmitter with a range of up to 10 m.. Remote control Radio set (breadboard and handheld transmitter) 358545035039600 Handheld transmitter 358500006465722 17

ETS Accessories Radar 1000 Domino Radar movement detector as opening pulse generator for automatic doors. Radar 1000 Domino Domino 1000 RC 358506466127000 Radar Merkur 2 ES.C Radar movement detector as opening pulse generator for automatic doors, directional. Radar Merkur Merkur 2 ES.C 358506466126000 Sensor strips Active infrared safety sensor for automatic doors. Secures the movement area. Stops or reverses when obstacles are identified. Inc. cable and external, flexible cable transition. Set I consisting of 2 sensor strips per leaf, up to max. 1.250 mm Set II consisting of 2 sensor strips per leaf, up to max. 1.600 mm Set III consisting of 2 sensor strips per leaf (BEA), up to max. 1.250 mm Sensor strips Set I 358503050000000 Set II 358503060000000 Set III 358506466401 EN 16005 Open stop for ETS (OA) Mounted on the power unit to provide additional mechanical open stop. Can be used in combination with the standard arm and slide rails (not possible in combination with the short clamps). Open stop OA ETS 358500450548106 18

ETS Accessories Mounting plate for ETS (MPL) Necessary for use in fire protection and for mounting on walls or narrow frame facings. Mounting plate MPL ETS 358500450548358 670 450 20 (100) 20 20 20 20 2020 20 90 10 20 225 20 (120) 110 130 Hinge side DIN-L Hinge-opposite side DIN-R Hinge side DIN-R Hinge-opposite side DIN-L Clamps (extension shaft) For use in special mounting situations Clamp (extention shaft) Clamp short (-13 mm) 358500450548124 Clamp 20 (+20 mm) 358500450548125 Clamp 50 (+50 mm) 358500450548126 Cladding for double leaf doors Cladding/spacer for 2-leaf systems. The cladding is cut to size on site and clamped between the two motors. Consists of cladding and fixing material. Cladding Total length V-ETS On request On request 19

ECO Schulte GmbH & Co. KG Iserlohner Landstraße 89 D-58706 Menden Phone +49 2373 9276-0 Fax +49 2373 9276-40 info@eco-schulte.de www.eco-schulte.de ECO Schulte GmbH & Co. KG - Subject to change / : 10999224; 03/2014/F 20 Your company logo