Installation & Maintenance Instructions KAPTIV ZERO AIR LOSS CONDENSATE DRAIN 04/08

Similar documents
Installation & Maintenance Instructions. Smart Guard Ultra ZERO AIR LOSS CONDENSATE DRAIN 02/09

ENGLISH. Installation & Maintenance Instructions

Installation & Maintenance Instructions SEPREMIUM 350. Oil /water separator 05/09

NEVER CHANGE ORIGINAL COMPONENTS WITH ALTERNATIVES.

Operating Instruction. Condensate separator CC 35

KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP NUFORS-CR MAGY-UL MAGY COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS

LEVEL SENSED DRAINS KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP 50 KAPTIV-CS-HP 500 NUFORS-CR MAGY-UL

Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU

The PURO GRAND Condensate Cleaner Installation instructions: Maintenance instructions:

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.

domnick hunter PNEUDRI DME012-RX - DME080-RX USER GUIDE Original Language

CA5000 Liquid CO 2 Freezer Backup System

Service package PDAD- -SP (en) Assembly instructions d [ ]

AHWG Remote Mount Hot Water Generator Module

Adsorption dryer PDAD. (en) Operating instructions g [ ]

The PURO Condensate Cleaner Installation instructions. Maintenance instructions:

AHWG Remote Mount Hot Water Generator Module for TTP Series Outdoor Split Unit

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

Heat Pump Water Heater. Table of Contents

EXC-450 User s Manual

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

PRO SERIES IMPORTANT SAFETY INFORMATION

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

- 1 - Updated on 18 March, 2010

Installation Instructions PP-AS20 Anti-Scale System

User s Manual

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Energy management function at adsorption dryer PDAD

OPER LV Wheeler Way

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

Inverted Bucket Steam Traps

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

HKF 8180 Operating instructions

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Installation & Service Manual

INSTALLER S & OWNER S MANUAL

Clean Water Made Easy

User manual Flushing device VAS 6337/1a

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER

SEPREMIUM 10 SEPREMIUM 20 SEPREMIUM 30 SEPREMIUM 10 SEPREMIUM 30

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

NO. F ISSUED: JUN. 15, 2009 REVISED: HOSHIZAKI MODULAR CRESCENT CUBER KMD-201AA KMD-201AWA MODEL SERVICE MANUAL

OPERATION & MAINTENANCE MANUAL AC880

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Electrical Mini Tank Water Heater anual, and Warranty nformation

Installation Instructions / Warranty. Metris 31060XX XX XX1

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

User s Manual and Warranty Information ThyssenKrupp Access

ModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation. Air Dryer Mounting Bracket (Item 1)

Smart Temp. Model

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

SERIES 101T MOISTURE ANALYZER QUICK START GUIDE

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Pond Pump 280 / 420 / 575. Operating instructions Notice d emploi Instrucciones de uso

PageOne 2-way Pager Assured 2-way messaging for critical communications

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

CT224 Setup Tutorial

Panel Fan Series Operators Manual (Galvanized and Polymer)

Model OP155 Air Dryer

HIn3550 Magnetic Field Monitor User's Manual

- 1 - Updated on 18 March, 2010

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Heat Pump Water Heater (Generation 4) Troubleshooting (Effective 1 Nov 2016)

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

B 353 COFFEE BREWING MACHINES MACHINES A CAFE KAFFEEBRUEHMASCHINEN KOFFIEZETAPPARATEN

HBTS Temperature Sensor For temperature measurement in refrigeration systems

MDX. Non-Cycling Refrigerated Compressed Air Dryers with Intellidrain Condensate Drain Trap. Operation & Maintenance Manual

5700-E Sediment Filter Installation & Start-Up Guide

15Hp/20Hp Deluxe Compressor-Dryer System

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

P4200W2 Series Air Dryer

1592 In Cab Monitor (ICM) QUICK START GUIDE

DEMA 844 Laundry Master Laundry Chemical Dispensing

SERIES 4000 AUTO GATE MANUAL

PDA20DX Air Purifying Dehumdifier Manual

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

OPERATION & MAINTENANCE MANUAL AC860

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

SUN EQUINOX HEATING SYSTEMS

Service Manual. Room Air Conditioner Split Wall-Mounted Type. Applies to: HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

Transcription:

Installation & Maintenance Instructions KAPTIV ZERO AIR LOSS CONDENSATE DRAIN 04/08 GENERAL OPERATION The KAPTIV is a zero-air-loss, electronic level sensing condensate drain. By installing the KAPTIV you prevent the loss of valuable compressed air during the discharge of the condensate. There are no sensors to foul up and the unit functions equally well with clear water or heavily emulsified and dirty water. The side and top inlets allow the KAPTIV to be widely applied. One model for all applications up to 85m³/min compressor capacity. The KAPTIV is easy to install. 1

SAFETY and PROPER USAGE To ensure safe and enduring performance of this product, you must comply strictly with the instructions enclosed herein. Non-compliance with instructions or improper handling of the product will void your warranty! This product is designed to drain condensate from compressed air systems. Usage of this product in conditions not specified in this manual or in contrary to the instructions hereby provided is considered IMPROPER. The manufacturer will not be held liable for any damages resulting from improper use of the product. IMPORTANT NOTICE Before installing this product, make sure it complies with your request and that it suits your application! Unpack the unit and visually inspect for any transport damage incurred after leaving our factory. Depressurise the system before installation or maintenance is carried out! Side inlet connection. The use of a ball valve is advisable. Top inlet connection. The use of a ball valve is advisable. Connect the outlet to an oil/water separator. We recommend using a PURO condensate cleaner. Connect the outlet to an oil/water separator. We recommend using a PURO condensate cleaner. 2

INSTALLATION INSTRUCTIONS Power cable connection Remove the protection cab from the connector and connect your power cable as shown Slowly open the ball valve to restore normal system pressure. Power Connection Optional Alarm Connection Revert to the programming manual to program the alarm feature. Press and hold the test button to check the valve function. Your KAPTIV is now ready for operation! The KAPTIV is pre-programmed to handle a standard compressed air installation requirement. If required, the KAPTIV can be programmed to handle the most demanding compressed air installation and application. Revert to the programming manual to alter the default settings of your KAPTIV. 3

MAINTENANCE INSTRUCTIONS These instructions are for cleaning the KAPTIV. If your KAPTIV requires maintenance, i.e. replacement of wearing components, please refer to our dedicated maintenance instructions (supplied with the service kit). Depressurise the system before installation or maintenance is carried out! 1. Close the condensate supply, i.e. close 2.Press the TEST button to empty the the ball valve which is installed in front of unit off any residual condensate and to the KAPTIV. depressurise the KAPTIV. 3. Switch off the electrical supply. 4. Open the housing by unscrewing the 4 fixing bolts and take apart the top part from the reservoir. (See page 7 for an exploded view) 5. Unscrew the valve from the bottom part of the housing using a 23 mm wrench. 6. Clean and/or Replace the valve parts. Also clean the other parts of the KAPTIV unit (i.e. the reservoir). 4

7.Screw the valve on the bottom part of the housing using a 23 mm wrench. 8. Close the housing by replacing the top part on the reservoir and fixing the 4 bolts. (Max. Torque 6Nm) (Make sure the electronics have not been in contact with water!) (Max. Torque 2Nm) 9. Switch on the electrical supply. 10. Restore the condensate supply. I.e. open the ball valve. 11. Press and hold the TEST button to check the valve function. Your KAPTIV is now ready for operation! 5

SERVICE CHART Date Description Name TECHNICAL SPECIFICATIONS Inlet connection G1/2 or NPT 1/2 Outlet connection G1/2 (Hose connection) Voltage 230V or 115V 50/60 Hz (+/- 10%) Max. operating pressure 16 BAR (230 PSI) Min. operating pressure Max. operating temperature Min operating temperature Weight 0 BAR (0 PSI) 50 ºC (120ºF) 2ºC (36ºF) 1,65 KG (4,42 lbs) 6

EXPLODED VIEW - IDENTIFY ALL COMPONENTS DIAGRAM Bolts Housing Top Part Connectors Electronics module Reservoir Valve stem Small spring Large spring Plunger Outlet Housing Bottom Part Plug + strainer Nuts 7

DMENSIONS (MM) SAFETY & WARNING INSTRUCTIONS ATTENTION - Observe valid and generally accepted safety rules when planning, installing and using this product. - Take proper measures to prevent unintentional operation of the product or damage to it. - Do not attempt to disassemble this product or lines in the system while they are under pressure. - Always depressurise the compressed air system before working on the system. It is important that personnel use safe working practices and observe all regulations and legal requirements for safety when operating this product. When handling, operating or carrying out maintenance on this product, personnel must employ safe engineering practices and observe all local health & safety requirements & regulations. International users refer to regulations that prevail within the country of installation. Most accidents, which occur during the operation and maintenance of machinery, are the result of failure to observe basic safety rules or precautions. An accident can often be avoided by recognising a situation that is potentially dangerous. Improper operation or maintenance of this product could be dangerous and result in an accident causing injury or death. The manufacturer cannot anticipate every possible circumstance, which may represent a potential hazard. The WARNINGS in this manual cover the most common potential hazards and are therefore not all-inclusive. If the user employs an operating procedure, an item of equipment or a method of working which is not specifically recommended by the manufacturer he must ensure that the product will not be damaged or made unsafe and that there is no risk to persons or property. 8

KAPTIV program Operational display symbols S flashing AC flashing At flashing Meaning Normal operations and condensate has not reached the discharge level. Discharge level has been reached, valve is opened to discharge the condensate. Service interval reached. Unit will operate normally, but it is time to periodically service/clean the unit. The alarm output has been activated. Alarm cycle and alarm output activated. The unit has purged more the (AC set value) times consecutively without pause. Sensing is de-activated, the unit will not discharge any condensate anymore until the alarm cycle is overruled. Alarm cycle and alarm output activated. The unit has purged more the (AC set value) times in (At set value) hours. Sensing is deactivated, the unit will not discharge any condensate anymore until the alarm cycle is overruled. Cleaning mode. Sensing is de-activated, no condensate will be discharged. The unit can be flushed and cleaned. SI value and other alarm values are reset. Use the TEST button to purge. Action None None Service/clean the unit. After the unit has been serviced, enter the CL mode to reset this service warning. Check why the alarm cycle has been activated and reset by pressing the OK button. Check why the alarm cycle has been activated and reset by pressing the OK button. Press OK to restore to normal operation. 9

Changing the program settings of the KAPTIV Press the PROG button for at least 10 seconds to enter the menu structure. You can move thru the menu structure by pressing the [up] or [down] arrows. When you have reached the required menu option, press OK to enter the submenu. In the submenu you can change the default setting by pressing the [up] or [down] arrows. After you have changed the default setting, simply press OK to save the change. Wait for at least 10 seconds (do not press any button) to exit the complete menu structure. KAPTIV Menu structure: Programming Meaning Action display symbols Default Settings. Resets all settings to factory settings Anti-Air lock setting. Each x hours the unit will purge regardless of the condensate level. Purge time setting. When the condensate has reached a predefined level the unit will purge and open the valve for x seconds. Alarm Cycle setting. If the units purges more then x times consecutively without pause, this could mean that an not logical amount of condensate is being discharged. The purging therefore stops and the alarm output is activated. Alarm time cycle setting. If the units purges more then (x times set in AC) in x hours, this could mean that an not logical amount of condensate is being discharged in a period of x hours. The purging therefore stops and the alarm output is activated. Alarm Output setting. The unit can be programmed to have a NO (Normally Open) or NC (Normally Closed) alarm relay output. Do not change. Sensing time setting. When the condensate has reached a predefined level the unit will wait for x seconds of continuous detection before purging and opening the valve for x seconds set in Pt. Service Interval setting. The unit will remind you every x weeks that it is time to periodically service and clean the unit. Note: each time the power is switched off, the unit will add 1 week to its count memory. Press OK to select choose 1-99 hours. 0 = disabled, 8 = default. choose 0.1-0.9 seconds. 0.3 = default. choose 1-99 times. 0 = disabled, 0 = default. choose 1-99 hours. 0 = disabled, 0 = default. choose NO or NC contacts. NC = default. 1 = default. choose 1-99 seconds. 0 = disabled, 1 = default. choose 1-99 weeks. 0 = disabled, 0 = default. 10