P-SERIES SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A36AA7 PUY-A36NKA7 PUY-A36NKA7-BS INDOOR UNIT FEATURES Ducted air handler provides a solution to cool and heat large zones Highly efficient totally enclosed ECM motor Selectable external static pressure: 0.30, 0.50 and 0.80 in.wg with 3 fan speeds at each static setting 1 inch R4.2 fiberglass free insulation reduces condensation and boosts efficiency Positive pressure cabinet with air leakage of less than 1.0% at 1.0 in. w.g. Unique blow through design allows simple coil cleaning when the blower is removed Multi-position installation: horizontal (left or right), vertical (up or down). For downflow configurations, the CMA-1 is recommended for proper management of condensate to prevent water blow-off in certain conditions Optional electric heat kit for additional heat capacity Optional humidifier control and ERV control OUTDOOR UNIT FEATURES Variable speed INVERTER-driven compressor Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft (70 ft. for A12/18/24/30) Low ambient cooling down to -20ºF providing 100% capacity (only for PUY models with wind baffles installed) 24-hour continuous operation (cooling mode) High pressure protection Fast restart due to bypass valve make it ideal for equipment cooling applications, such as data centers Superior energy and operational efficiency
SPECIFICATIONS: PVA-A36AA7 & PUY-A36NKA7(-BS) Model number Indoor unit PVA-A36AA7 Outdoor unit PUY-A36NKA7 PUY-A36NKA7-BS Cooling*1 Maximum Capacity Btu/h 36,000 Rated Capacity Btu/h 36,000 Minimum Capacity Btu/h 14,600 Maximum Power Input W 3,250 Rated Power Input W 3,250 Moisture Removal Pints/h 5 Sensible Heat Factor 1 Power factor % 88 Efficiency SEER 19 EER *1 10 Electrical Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 187-253 Voltage: Indoor - Outdoor, S1-S2 V AC 208V / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote controller V DC 12 Recommended Fuse/Breaker Size A 30 Recommended Wire Size (Indoor - Outdoor) AWG 14 Indoor unit MCA A 6 Fan Motor Full Load Amperage A 4 Fan Motor Output W 430 Airflow Rate, Dry CFM 788-956-1125 Airflow Rate, Wet CFM n/a External Static Pressure in.wg 0.30-0.50-0.80 Sound Pressure Level db(a) 30-34-38 Drain Pipe Size In. (mm) 3/4 FPT (19.05) Condensate Lift Mechanism, Max. Distance In. (mm) n/a Heat Exchanger Type External Finish Color Plate fin coil Galvanized steel cabinet-powder coated Slate Gray Unit Dimensions // Grille Dimensions W: In. (mm) 25 (635) D: In. (mm) 21-5/8 (548) H: In. (mm) 59-1/2 (1511) Unit Weight Lbs. (kg) 78 (172)
SPECIFICATIONS: PVA-A36AA7 & PUY-A36NKA7(-BS) Model number Indoor unit PVA-A36AA7 Indoor unit operating temperature range Outdoor unit Cooling Intake Air Temp (Maximum / Minimum) Heating Intake Air Temp (Maximum / Minimum) PUY-A36NKA7 PUY-A36NKA7-BS F 90 DB, 73 WB / 66 DB, 59 WB F 82 DB / 50 DB Outdoor unit MCA A 25 Outdoor unit operating temperature range MOCP A 31 Fan Motor Full Load Amperage A 0.5 + 0.5 Fan Motor Output W 74 Airflow Rate CFM 3,880 Refrigerant Control Defrost Method Heat Exchanger Type Electronic Expansion Valve Reverse Cycle Cross fin Sound Pressure Level, Cooling*1 db(a) 52 Sound Pressure Level, Heating*2 db(a) 53 Compressor Type Compressor Model INVERTER-driven twin rotary MNB33FBRMC-L Compressor Rated Load Amps A 8 Compressor Locked Rotor Amps A 13 Compressor Oil Type // Charge oz. FV50S // 45 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base pan heater Unit Dimensions W: In. (mm) 1050 [41-5/16] n/a D: In. (mm) 330 + 30 [13+1-3/16] H: In. (mm) 1338 [52-11/16] Package Dimensions W: In. 42-15/16 D: In. 17-11/16 H: In. 56-4/16 Unit Weight Lbs. (kg) 214 (97) Package Weight Lbs. (kg) 243 (110) Cooling Intake Air Temp (Maximum / Minimum) Heating Intake Air Temp (Maximum / Minimum) F 115 DB / -20* DB F n/a Thermal Lock-out / Re-start Temperatures** F n/a
SPECIFICATIONS: PVA-A36AA7 & PUY-A36NKA7(-BS) Model number Indoor unit PVA-A36AA7 Outdoor unit PUY-A36NKA7 PUY-A36NKA7-BS Refrigerant Type R410A Charge Lbs, oz 10 lbs, 6 oz Piping Gas Pipe Size O.D. (Flared) In.(mm) 5/8 (15.88) Liquid Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52) Maximum Piping Length Ft. (m) 225 (69) Maximum Height Difference Ft. (m) 100 (30) Maximum Number of Bends 15 AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) *1 Cooling (Indoor // Outdoor) F 80 F DB, 67 F WB // 95 F DB, 75 F WB Notes *Wind baffles required to operate below 23 F DB in cooling mode. PUY with wind baffle: -20 F - 115 F. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures SEACOAST PROTECTION External Outer Panel: Phosphate coating + Acrylic-Enamel coating Fan Motor Support: Epoxy resin coating (at edge face) Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Notes:
ACCESSORIES: PVA-A36AA7 & PUY-A36NKA7(-BS) PVA-A36AA7 3-Pole Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] Drain Pan Level Sensor (Control for indoor unit shut off to prevent drain pan overflow) TAZ-MS303 DPLS2 Advanced Blue Diamond Mini-Condensation pump w/ Resevoir & Sensor (110V) X87-711 - 110 Advanced Blue Diamond Mini-Condensation pump w/ Resevoir & Sensor (208/230V) X87-721 - 208/230 Extension Cord for Blue Diamond Pump C13-103 MegaBlue Blue Diamond Condensate Pump (110-230V) X87-835 Remote Sensor (extensible) Connector Cable for Remote Display PAC-SE41TS-E PAC-SA88HA-EP PAC-725AD-E(10pcs) Connector for CN32 (remote on/off) Connector for CN24 (Back up heating) Connector for CN30 (LLC) Remote Operation Adapter (with wire terminals for remote ON/OFF and operation status/ error) External fan / Heater control relay adapter Backlit, wall-mounted, wireless Wireless adapter BACnet and Modbus Interface Wall-mounted, Wired Wired remote controller PAC-SE55RA-E PAC-SE56RA-E PAC-SE57RA-E PAC-SF40RM-E *1 CN24RELAY-KIT-CM3 MHK1 PAC-USWHS002-WF-1 PAC-UKPRC001-CN-1 PAC-YT53CRAU-J PAR-32MAA-J T-STAT Interface PAC-US444CN-1 *2 Wired remote controller Signal Receiver Wireless Remote Controller Wireless Signal Receiver Wire for Remote ON/OFF with CN32 connector Lockdown Bracket for wireless, hand-held, remote controllers PAR-32MAA PAR-SA9CA-E PAR-FL32MA-E PAR-FA32MA-E PAC-715AD RCMKP1CB *1 Unable to use with wireless remote controller *2 Unable to use with the electric heat time delay PUY-A36NKA7(-BS) Twinning Distribution Pipe (50:50) Air Outlet Guide (two pieces are required) Front Wind Baffle (two pieces are required) Drain socket Centralized Drain Pan MSDD-50TR-E PAC-SH96SG-E WB-PA3 PAC-SG61DS-E PAC-SH97DP-E
ACCESSORIES: PVA-A36AA7 & PUY-A36NKA7(-BS) PUY-A36NKA7(-BS) M-NET Converter PAC-SF83MA-E Control/Service Tool PAC-SK52ST Wall mounting bracket (Powder-coated Steel) QCWB2000M-1 Wall mounting bracket (316 Series Stainless Steel) QCWBSS M-NET control adapter for Building Management System PAC-SF83MA-E Outdoor Unit Mounting Pad 24" x 42" x 3" ULTRILITE2 Outdoor Unit 3-1/4 inch Mounting Base - Pair (Plastic) DSD-400N MiniSplit Mounting Stand-Dual Fan models - 12" QSMS1202M MiniSplit Mounting Stand-Dual Fan models - 18" QSMS1802M MiniSplit Mounting Stand-Dual Fan models - 24" QSMS2402M 3/8 x 5/8 x 10' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-10 3/8 x 5/8 x 15' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-15 3/8 x 5/8 x 30' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-30 3/8 x 5/8 x 50' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-50 3/8 x 5/8 x 65' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-65 3/8 x 5/8 x 100' / 1/2" Lineset (Twin-Tube Insulation) MPLS385812T-100
DIMENSIONS: PVA-A36AA7 & PUY-A36NKA7 (-BS) INDOOR UNIT PVA-A12, 18, 24, 30, 36, 42AA7 PVA-A36AA7 Left side 2-ø4.6 Burring ring Holes for electric heat installation 1 Refrigerant piping brazing flare connection(gas) 2 Refrigerant piping brazing flare connection(liquid) ø26 Knockout Hole Secondary drain pipe (Indoor /Outdoor (Emergency ddraining) unit connection) Primary P drain pipe (Gravity drain) 77.8(3-1/8) (Horizontal left) 66(2-5/8) ø26 Knockout Hole (Indoor / Outdoor unit connection) G 70(2-13/16) H 55(2-3/16) Top 8(3/8) 43(1-3/4) 8(3/8) 92(3-5/8) 30(1-3/16) Secondary drain pipe (Emergency ddraining) 55(2-3/16) 3 Air filter Bottom B(Duct) 28.8(1-3/16) C 76(3) Air outlet Air inlet A Unit:mm(in.) Note 1.Keep the se service space for maintenance at at the the front front.. ø26 Knockout Hole (Remote controller t transmission) Terminal block (Remote controller t transmission) Terminal block (Indoor / Outdoor unit connection) Control bbox 43(1-3/4) Primary drain pipe (Gravity drain) Secondary drain pipe (Emergency ddraining) (Horizontal Right) Primary drain pipe (Gravity drain) D 525.5(20-3/4) 8(3/8) F 55(2-3/16) 13.2(9/16) E 24(15/16) 548(21-5/8) 117.4 (4-5/8) 402(15-7/8) (Duct) Model 3 Nominal Filter sisize Duct Connection J 36.8(1-1/2) 508X508X25.4 477X402 P PVA-A30AA4 (20X20X1) (18-13/16X15-7/8) Model A B C D E F G H J 1 Gas pipe 2 Liquid pipe Unit: mm (in.) Model A B C D E F G H J P VA-A36AA4 Gas Pipe 508X609.6X25.4 Liquid Pipe 579X402 PVA-A12AA7 534 477 382.6 266.5 1378 737 953.5 792 461 (20X24X1) (22-13/16X15-7/8) P VA-A30AA4 P VA-A42AA4 432 (17) 376 (14-13/16) 281 (11-1/8) 224 (8-7/8) 1275 (50-1/4) 680 (26-13/16) 823 (32-7/16) 735.5 (29) 360 (14-3/16) Φ 12.7 (1/2) Φ 6.35 (1/4) PVA-A18AA7 (21) (18-13/16) (15-1/8) (10-1/2) (54-1/4) (29-1/16) (37-9/16) (31-3/16) (18-3/16) Ø15.88 Ø9.52 PVA-A24AA7 534 (21) 477 (18-13/16) 382.6 (15-1/8) 266.5 (10-1/2) 1378 (54-1/4) 737 (29-1/16) 953.5 (37-9/16) 792 (31-3/16) 461 (18-3/16) PVA-A30AA7 P VA-A36AA4 635 579 484.6 317.5 1511 798.5 1053 853.5 563 (5/8) (3/8) Φ 15.88 (5/8) Φ 9.52 (3/8) PVA-A36AA7 P VA-A42AA4 (25) (22-13/16) (19-1/8) (12-1/2) (59-1/2) (31-7/16) (41-1/2) (33-5/8) (22-3/16) 635 (25) 579 (22-13/16) 484.6 (19-1/8) 317.5 (12-1/2) 1511 (59-1/2) 798.5 (31-7/16) 1053 (41-1/2) 853.5 (33-5/8) 563 (22-3/16) PVA-A42AA7 50.8(2) 470(18-9/16) Front Top ø26 Knockout Hole (Remote controller t transmission) Bottom Right side Model Nominal Filter Size Duct Connection PVA-A12AA7 508 x 406.4 x 25.4 376 x 402 PVA-A18AA7 (20 x 16 x 1) (14-13/16 x 15-7/8) PVA-A24AA7 508 x 508 x 25.4 477 x 402 PVA-A30AA7 (20 x 20 x 1) (18-13/16 x 15-7/8) PVA-A36AA7 508 x 609.6 x 25.4 579 x 402 PVA-A42AA7 (20 x 24 x 1) (22-13/16 x 15-7/8) 17 2016 Mitsubishi Electric US, Inc.
DIMENSIONS: PVA-A36AA7 & PUY-A36NKA7 (-BS) Unit: mm<in> Dimensions of space needed for service access are shown in the below diagram. Please secure the unit firmly with 4 foundation (M10<W3/8>) bolts. (Bolts and washers must be purchased locally.) Piping and wiring connections can be made from 4 directions: FRONT, Right, Rear and Below. Installation Feet 0 FOUNDATION 25 <31/32> Max. 50 <2> 330 <13> 56 <2-7/32> 500 <19-11/16> 70 <2-3/4> Air Discharge Side Air Intake 362 <14-1/4> Rear Air Intake 2-12 36 Oval holes (Foundation Bolt M10<W3/8>) 1050 <41-11/32> ( Earth terminal 53 <2-3/32> 42 <1-21/32> Terminal connection Left... Power supply wiring Right... Indoor/Outdoor wiring ) Example of Notes 1... Refrigerant GAS pipe connection (FLARE) ø15.88(5/8f)... 2 Refrigerant LIQUID pipe connection (FLARE) ø9.52(3/8f) *1... Indication of STOP VALVE connection location. 1338 <52-11/16> 632 <24-7/8> Service panel 1 Piping Knockout Hole Details 92 <3-5/8> Right trunking hole 92 <3-5/8> 75 <2-15/16> 22.5 <7/8> 100 <3-15/16> Scale 1:5 5<3/16> 3/4 Conduit attachment 136 154 <5-11/32> <6-1/16> ø 27.8<1-3/32> ø 22.2<7/8> 1/2 Conduit attachment Rear piping hole 45 <1-25/32> 110 <14-11/32> 86 <3-3/8> 81 <3-3/16> When installing the conduit. Set the attachment to the inner side of each panel. 24.7 <31/32> 5<3/16> 73 <2-7/8> 5<3/16> 61 <2-3/8> 27 <1-1/16> ø 92 <3-5/8> 27 <1-1/16> 29 <1-5/32> (ø 37<1-15/32>knockout) <3-ø5/92 8> 26 <1-1/32> (ø 37<1-15/32>knockout) (ø 24<15/16>knockout) Rear trunking hole 73 <2-7/8> 92 <3-5/8> 92 <3-5/8> 75 <2-15/16> Right piping hole 26 <1-1/32> Front piping hole (ø 24<15/16>knockout) (ø 24<15/16>knockout) ø 92 <3-5/8> Rear piping cover Bottom piping hole 160 <6-5/16> 160 <6-5/16> 160 <6-5/16> Drain hole (5-ø33<1-5/16>) PUY-A42NKA7 PUY-A42NKA7-BS 26 <1-1/32> 73 <2-7/8> (ø 37<1-15/32>knockout) Front trunking hole Front piping cover 53 <2-3/32> 27 <1-1/16> Air intake *1 450 <17-23/32> 369 <14-17/32> 26 <1-1/32> 2 *1 442 <17-2/5> Handle for moving PUY-A36NKA7 PUY-A36NKA7-BS 16 Handle for moving Handle for moving 1063 <41-7/8> Handle for moving PUZ-A42NKA7 PUZ-A42NKA7-BS 370 <14-9/16> Side Air Intake 40<1-9/16> 15 <3/5> Service space 30 <1-3/16> 150mm <5-29/32> 500 <19-11/16> 1000mm <39-3/8> 15mm <3/5> 2-U Shaped notched holes (Foundation Bolt M10<W3/8>) 225 <8-27/32> 600 <23-5/8> 28 <1-3/32> 225 <8-27/32> <Foundation bolt height> 15mm <3/5> Rear Air Intake 417 <16-13/32> 4 PIPING-WIRING DIRECTIONS 19 <3/4> 3 FOUNDATION BOLTS 150 <5-29/32> The diagram below shows a basic example. Explantion of particular details are given in the installation manuals etc. 2 SERVICE SPACE FREE OCH636 1 FREE SPACE (Around the unit) PUZ-A36NKA7 PUZ-A36NKA7-BS PUY-A36NKA7(-BS) 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com FORM# PVA-A36AA7 / PUY-A30NKA7(-BS) 201702Ver3