Product Data. 350AAV Highly-Efficient 4-Way Multipoise Fixed-Capacity Deluxe Condensing Gas Furnace Sizes 040 thru 140

Similar documents
Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning.

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE. Sizes 040 thru 140 Series D. Form No. PDS 350M.40.

CONDENSING GAS FURNACE

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT DELUXE CONDENSING GAS FURNACE. Sizes 040 thru 140. Form No. PDS 350M.40.

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

352AAV 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE. Sizes 060 thru 120. Catalog No. PDS 352A.60.1

Product Data. 352AAV 4-Way Multipoise Two-Stage Condensing Gas Furnace. Sizes 060 thru 120

340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Sizes 040 thru 140 FEATURES

395CAV Sizes 045 thru 155 Series H and J

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

Product Data. 340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140

310AAV/310JAV Sizes 045 thru 155 Series A

ama 311AAV/311JAV Sizes 045 thru 155 Series A 4-Way Multipoise Induced Combustion Gas Furnace Form No. PDS 311A.45.3

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace. Input Capacities: 40,000 thru 138,000 Btuh

Product Data. 58MCB 4-WAY MULTIPOISE FIXED-CAPACITY CONDENSING GAS FURNACE Input Rates: 40,000 thru 138,000 Btuh

355MAV Sizes 040 thru 120 Series E

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Product Data. 58MTA Highly-Efficient 4-Way Multipoise Two-Stage Direct-Vent Deluxe Condensing Gas Furnace. Input Capacities: 60,000 thru 120,000 Btuh

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58STA/STX 4-WAY MULTIPOISE INDUCED-COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh THE CARRIER 58STA/STX GAS FURNACE

58CTA/CTX PERFORMANCE 80 TWO --- STAGE WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58CTA/CTX PERFORMANCE 80 TWO-STAGE 4-WAY MULTIPOISE INDUCED-COMBUSTION FURNACE Input Capacities: 45,000 thru 155,000 Btuh

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Installation, Start-Up, and Operating Instructions For Sizes , Series 180

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160

Product Data. 58MEC PERFORMANCE BOOST WAY MULTIPOISE STAGE CONDENSING GAS FURNACE Input Rates: 60,000 thru 120,000 Btuh

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

Installation, Start-Up, and Operating Instructions For Sizes , Series 100

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150

Product Data. 58DLA/DLX WeatherMaker 8000 Deluxe 4-Way Multipoise Induced-Combustion Gas Furnace. Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58DLA/DLX COMFORT 80 DELUXE 4-WAY MULTIPOISE INDUCED-COMBUSION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh

Product Data. S QuieTecht noise reduction system. S SmartEvapt -Humidity control when using a Thermidistat Control

Product Data. Perfect Heatt technology, the ultimate in heating comfort...

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

PLUS 95st MODEL 355CAV DELUXE 4 -WAY MULTIPOISE VARIABLE -SPEED MULTI -STAGE CONDENSING GAS FURNACE Series 100 Input Rates: 60,000 thru 120,000 Btuh

Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Product Data. Infinity 96 Model 58MVB Deluxe 4-Way Multipoise Variable-Speed Condensing Gas Furnace. Series 100 Input Rates: 40,000 thru 120,000 Btuh

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit

Product Data STANDARD FEATURES

Product Data. 58CTA/CTX PERFORMANCE 80 TWO-STAGE 4-WAY MULTIPOISE INDUCED-COMBUSTION FURNACE Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace

Product Data. S ECM Blower Motor included S QuieTecht noise reduction system S SmartEvapt Humidity control when using a Thermidistatt Control

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. Comfort Heatt technology, the ultimate in heating comfort...

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY*

Product Data. IdealComfortt technology, the ultimate in heating comfort...

Product Data A {Jurisdictions where warranty benefits cannot be conditioned on registration

Product Data. 59TP5A Performance Boost Two---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 59TN6A InfinityR Two---Stage, Variable Speed Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data 987MA EVOLUTIONR MODULATING 4 -WAY MULTIPOSE, VARIABLE SPEED CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY*

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Wt. Lbs Model Number (BTUH) Hz

Cooling Capacity CFM range

Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. 58CVA/CVX INFINITY 80 VARIABLE SPEED 4---WAY MULTIPOISE GAS FURNACE Input Capacities: 70,000 thru 155,000 Btuh Series 160

Cooling Capacity CFM in. w.c. (125 Pa)

Product Data PG96VAT TWO -STAGE, 4 -WAY MULTIPOISE VARIABLE -SPEED CONDENSING GAS FURNACE

TECHNICAL SPECIFICATIONS

Product Data. 58PHA/PHX PERFORMANCE BOOST WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 135,000 Btuh

G6RC Series TECHNICAL SPECIFICATIONS

Product Data. 59MN7A Infinityr Modulating Way Multipoise Condensing Gas Furnace Series 100

MERIT SERIES Downflow

Product Data. 59SC2A Comfort Series Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data PG95XAT CONDENSING GAS FURNACE SERIES B STANDARD FEATURES

Product Data. 925TA PREFERREDt SERIES TWO -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES B

Product Data. 59TP6A Performance Two-Stage, Variable Speed 4-Way Multipoise Condensing Gas Furnace Series 2, 3

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A. Select Models

TECHNICAL SPECIFICATIONS

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

RG7D 1-Stage Heat Series

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A AND B. Select Models

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100

Product Data PERFECT HEATT TECHNOLOGY, THE ULTIMATE IN HEATING COMFORT...

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

8+* Bulletin No November 1997

TSTAT0201CW Recommended (sold separately)

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 2

TECHNICAL SPECIFICATIONS

Installation, Start-up, Operating, and Service and Maintenance Instructions -Series A

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

13 GEP A L P - 1 A

Transcription:

ly-efficient 4-Way Multipoise Fixed-Capacity Deluxe Condensing Gas Furnace Sizes 040 thru 140 Product Data A05085 Utilizing the extensive resources available to Bryant, a new standard of excellence has been achieved with the model Plus 90 TM 4-Way Multipoise Furnace. The model was designed around requirements established by customer focus groups. The result is a unique 4-way multipoise condensing furnace with features like no other product in its class. The builds on the many Bryant successes in the furnace industry and establishes a new standard f all high-efficiency gas furnaces. FEATURES 3-Pass Primary Heat Exchangers This design accelerates heat transfer and extracts heat that conventional heat exchangers waste up the flue. The weld-free primary heat exchangers are made of aluminized steel f crosion resistance. Flow-Through Secondary Heat Exchangers Each cell is laminated with our patented Everlastic TM polypropylene f greater resistance to crosion. This breakthrough in heating technology helps extend the life of the furnace f years of trouble-free Plus 90 perfmance. The heat exchanger is positioned in the furnace to extract additional heat from the combustion products regardless of furnace ientation. Perfect Light Igniter Bryant s unique SiN igniter is not only physically robust but it is also electrically robust. It is capable of running at line voltage and does not require complex voltage regulats as do other brands. This unique feature further enhances the reliability of gas furnace and continues Bryant s tradition of providing a reliable and durable product. Fan On Plus Improves comft all year long by allowing you to select the continuous fan speed right at the thermostat. SmartEvap Allows your system to reduce summertime humidity levels by nearly 10% over standard systems. Media Filter Cabinet Enhanced indo air quality in your home is made easier with our media filter cabinet a standard accessy on all Deluxe furnaces. When installed as a part of your system, this cabinet allows f easy and convenient addition of a Bryant high-efficiency air filter. Warranty Limited Lifetime Warranty on the heat exchangers f the lifetime of iginal owner in single family residence; 20 years in other residential and commercial applications. Five-year Limited Warranty on entire unit. Microprocess Control Center The printed-circuit board and all internal wiring are facty installed. Convenient terminals permit quick-connection of a thermostat, a humidifier, an air cleaner, and air conditioning control circuits. The control has adjustable blower off delay switches. As an added feature, the control has a built-in status indicat and self-test feature. The status indicat flashes to indicate a problem condition and assists the servicer in diagnosis. The self-test feature allows f a complete check of the maj components in only seconds. 4-Way Multipoise Design Allows a model to be installed in an upflow, downflow, hizontal ientation. Facty configured f upflow applications. Simple changes in the drain connections are all it takes to change to any of the 3 other possible positions. The model is available in 12 heat/airflow combinations, and when combined with the 4-way design, allows f 48 different applications. Direct Non-direct Venting The can be installed as a 1 pipe/non-direct vent 2 pipe/direct vent furnace (except 140 size unit and in manufactured/mobile home installations). This provides added flexibility to meet diverse installation needs. Fully-Insulated Casing Foil-faced insulation in the heat exchanger section cuts heat loss, and insulation in the blower section reduces noise levels. The casing also has the required openings f left- right-side connection of gas, electric, drain, and vent connections. Monopt Inshot Burners Produce precise air-to-gas mixture which gives a clean burn. The large monopt on the inshot injection-type burners seldom, if ever, needs cleaning. Quality Registration The is engineered and manufactured under an ISO 9001 registered quality system. Certifications The units are CSA (A.G.A. and C.G.A.) design certified f use with natural and propane gases, as well as GAMA efficiency rating certified. The furnace is facty-shipped f use with natural gas. A CSA listed gas conversion kit is required to convert furnace f use with propane gas. The model meets the Califnia Air Quality Management District emission requirements. Except f the 140 size unit, all models can be installed in a manufactured (mobile) home when the optional kit is used in direct vent (2-pipe) application, and in elevations up to 10,000 ft (140 size unit limitation 7,000 ft).

26 15 16" 26 1 4" 24 1 2" CONDENSATE DRAIN TRAP LOCATION (DOWNFLOW & HORIZONTAL LEFT) 7 8-IN. DIA POWER CONN 7 8-IN. DIA ACCESSORY POWER ENTRY CONDENSATE DRAIN TRAP LOCATION (ALTERNATE UPFLOW) 17 5 16" 24 1 2" 27 9 16" TYP 27 5 8" 29 11 16" TYP 32 5 8" TYP 30 13 16" 33 1 4" TYP 18 1 4" DIMPLE LOCATORS FOR HORIZONTAL HANGING NOTES: 1. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturerí s recommendations f equivalent diameters. 2. Minimum return-air opening at furnace: 1 a. F 800 CFM 16-in. round 14 / 2 x 12-in. rectangle. 1 b. F 1200 CFM 20-in. round 14 / 2 x 19 1 / 2-in. rectangle. 1 c. F 1600 CFM 22-in. round 14 / 2 x 23 1 / 4-in. rectangle. d. F airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature f specific use of single side inlets. The use of both side inlets, a combination of and the, the only will ensure adequate return air openings f airflow requirements above 1800 CFM at 0.5 W.C. ESP. 28 1 2" 26 15 16" 26 1 4" 22 5 16" 9 7 16" TYP 22 5 16" 2-IN. COMBUSTION- AIR CONN AIRFLOW 13 /16" A D 13 /16" OUTLET CONDENSATE DRAIN TRAP LOCATION (DOWNFLOW & HORIZONTAL RIGHT) OR ALTERNATE 1 2-IN. DIA GAS CONN 9 16" TYP 30 1 2" CONDENSATE DRAIN LOCATION (UPFLOW) 11 /16" INLET E 11 /16" CONDENSATE DRAIN LOCATION (UPFLOW) DIMENSIONS (In.) A D E SHIP. WEIGHT (Lb) 024040 17-1/2 15-7/8 16 174 036040 17-1/2 15-7/8 16 175 024060 17-1/2 15-7/8 16 180 036060 17-1/2 15-7/8 16 182 048060 17-1/2 15-7/8 16 183 036080 17-1/2 15-7/8 16 198 048080 17-1/2 15-7/8 16 205 060080 21 19-3/8 19-1/2 214 048100 21 19-3/8 19-1/2 229 060100 21 19-3/8 19-1/2 232 060120 24-1/2 22-7/8 23 261 060140 24-1/2 22-7/8 23 261 19" 13 16" 5 8" OUTLET 2-IN. COMBUSTION- AIR CONN 5 16" 1 2-IN. DIA GAS CONN 7 8-IN. DIA POWER CONN 1 2-IN. DIA GAS CONN 2-IN. VENT CONN 1 2-IN. DIA THERMOSTAT ENTRY 22 11 16" SIDE INLET 23 1 4" TYP SIDE INLET 26 15 16" TYP 14 1 2" TYP 1 1 4" 1" 1 2-IN. DIA THERMOSTAT ENTRY 2-IN. VENT CONN 39 7 8" 22 11 16" SIDE INLET 1" 22 1 4" TYP 7 16" 24 3 16" BOTTOM INLET 11 16" A05070 times times 2

Clearance to Combustibles INSTALLATION This fced air furnace is equipped f use with natural gas at altitudes 0-10,000 ft (0-3,050m), except 140 size Furnaces are only approved f altitudes 0-7,000 ft. (0-2,135m). An accessy kit, supplied by the manufacturer, shall be used to convert to propane gas use may be required f some natural gas applications. This furnace is f indo installation in a building constructed on site. This furnace may be installed in a manufactured (mobile) home when stated on rating plate and using facty authized kit. This furnace may be installed on combustible floing in alcove closet at minimum clearance from combustible material. This appliance requires a special venting system. Refer to the installation instructions f parts list and method of installation. This furnace is f use with schedule-40 PVC, PVC-DWV, CPVC, ABS-DWV pipe, and must not be vented in common with other gas-fired appliances. Construction through which vent/air intake pipes may be installed is maximum 24 inches (600 mm), minimum 3/4 inches (19 mm) thickness (including roofing materials). Cette fournaiseà air pulsé est équipée pour utilisation avec gaz naturel et altitudes comprises entre 0-3,050m (0-10,000 pi), excepté queles fournaises de 140 taille sont pour altitudes comprises entre 0-2,135m (0-7,000 pi). Utiliser une trousse de conversion, fournie par le fabricant, pour passer au gaz propane ou pour certaines installations au gaz naturel. Cette fournaise à air pulsé est pour installation à l intérieur dans un bâtiment construit sur place. Cette fournaise à air pulsé peut être installée dans une maison préfabriquée (maison mobile) si prescrit par la plaque signalétique et si l on utilise une trousse specifiée par le fabricant. Cette fournaise peut être installée sur un plancher combustible dans un enfoncement ou un placard en observant les dégagements minimums avec les matériaux combustibles. Cet appareil nécessite un système d évacuation spécial. La méthode d installation et la liste des pièces nécessaires figurent dans les instructions d installation.cette fournaise doit s utiliser avec la tuyauterie des nomenclatures 40 PVC, PVC-DWV, CPVC, ou ABS-DWV et elle ne peut pas être ventilée conjointment avec d autres appareils à gaz. Épaisseur de la construction au travers de laquelle il est possible de faire passer les tuyaux d aération (admission/évacuation): 24 po (600 mm) maximum, 3/4 po (19 mm) minimum (y compris la toiture). F upflow and downflow applications, furnace must be installed level, pitched within 1/2" of level. F a hizontal application, the furnace must be pitched minimum 1/4" to maximum of 1/2" fward f proper drainage. See Installation Manual f IMPORTANT unit suppt details on hizontal applications. Pour des applications de flux ascendant et descendant, la fournaise doit être installée de niveau ou inclinée à pas plus de 1/2" du niveau. Pour une application hizontale, la fournaise doit être inclinée entre minimum 1/4" et maximum 1/2" du niveau pour le drainage approprié. En cas d'installation en position hizontale, consulter les renseignements IMPORTANTS sur le suppt dans le manuel d'installation. MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION ALL POSITIONS: Minimum front clearance f service 30 inches (762mm). * 140 size furnaces require 1 inch back clearance to combustible materials. DOWNFLOW POSITIONS: F installation on combustible flos only when installed on special base No. KGASB0201ALL, Coil Assembly, Part No. CD5 CK5, Coil Casing, Part No. KCAKC. HORIZONTAL POSITIONS: Line contact is permissible only between lines fmed by intersections of top and two sides of furnace jacket, and building joists, studs, framing. Clearance shown is f air inlet and air outlet ends. Ø 120 and 140 size furnaces require 1 inch clearance to combustible materials. DÉGAGEMENT MINIMUM EN POUCES AVEC ÉLÉMENTS DE CONSTRUCTION COMBUSTIBLES POUR TOUS LES POSITIONS : * Dégagement avant minimum de 762mm (30 po) pour l entretien. Pour les fournaises de 140 taille, 1 po (25mm) dégagement des matériaux combustibles est requis au-arriere. POUR LA POSITION COURANT DESCENDANT: Pour l installation sur le plancher combustible seulement quand on utilise la base spéciale, pièce n KGASB0201ALL, l ensemble serpentin, pièce n CD5 ou CK5, ou le carter de serpentin, pièce n KCAKC. POUR LA POSITION HORIZONTALE: Le contact n est permis qúentre les lignes fmées par les intersections du dessus et des deuxcôtés de la chemise de la fournaise, et des solives, des montants ou de la charpente du bátiment. La distance indiquée concerne l extrémité du tuyau d arrivée d air et l extrémité du tuyau de stie d air. Ø Pour les fournaises de 120 et 140 taille, 1 po (25mm) dégagement des matériaux combustibles est requis au-dessous. 324999-201 REV. D (LIT TOP) R LEVEL (0") TO 1/2" MAX FRONT UPFLOW OR DOWNFLOW This furnace is approved f UPFLOW, DOWNFLOW and HORIZONTAL installations. Cette fournaise est approuvée pour l installation HORIZONTALE et la circulation d air VERS LE HAUT et VERS LE BAS. Clearance arrows do not change with furnace ientation. 0" B A A R C R I K E R E 0" MIN 1/4" TO 1/2" MAX S I DE C O T E S Clearance in inches Dégagement (po). FRONT TOP/PLENUM DESSUS/CHAMBRE D AI 1" BOTTOM DESSOUS 0" Ø Les fléches de dégagement ne change pas avec l ientation de la générateur d air chaud. F URNACE F OURNAISE FRONT AVAN T F R A O V N A T N T HORIZONTAL 3" S I DE C O T E S 0" S L E ÈNTRR VI E C T E I E N 30 * MIN Vent clearance to combustibles 0". 0 (po) Dégagement d évent avec combustibles. A02148 TSTATBBNAC01-C TSTATBBNHP01-C* TSTATBBN2S01-C* TSTATBBBAC01-B TSTATBBPRH01-B** Controls Thermostats and Zoning Non-Programmable Thermostat Selection F use with 1-spd. Air Conditioner - deg. F/C, Auto Changeover F use with 1-spd. Air Conditioner - deg. F/C, Auto Changeover F use with 2-spd. Air Conditioner - deg. F/C, Auto Changeover F use with 1-spd. Air Conditioner - deg. F/C F multi-use / stage configurations - deg. F/C, Auto Changeover/Temperature and Humidity Control * Model HP and 2S thermostat must be field converted to air conditioner operation. **Thermidistat Control is versatile and can be configured f multiple use and staging, it must be configured f each specific application. TSTATBBPAC01-B TSTATBBPHP01-B* TSTATBBP2S01-B* TSTATBBSAC01 TSTATBBPDF01-B** TSTATBBPRH01-B*** Programmable Thermostat Selection F use with 1-spd. Air Conditioner - deg. F/C, Auto Changeover, 7-Day Programmable F use with 1-spd. Air Conditioner - deg. F/C, Auto Changeover, 7-Day Programmable F use with 2-spd. Air Conditioner - deg. F/C, Auto Changeover, 7-Day Programmable F use with 1-spd. Air Conditioner - deg. F/C, 5-2 Day Programmable F use with multi-stage applications - deg. F/C, Auto Changeover, 7-Day Programmable F multi-use / stage configurations - deg. F/C, Auto Changeover, 7-Day Programmable/Temperature and Humidity Control * Model HP and 2S thermostat must be field converted to air conditioner operation. **Dual Fuel thermostat is used with furnace and heat pump application ***Thermidistat Control can be configured f multiple use and staging, it must be configured f each specific application. ZONEBB32(AC/HP)01 ZONEBB2KIT01-B ZONEBB4KIT01-B ZONEBB8KIT01-B Zoning Control Selection Zone Perfect Two-Zone kit Zone Perfect Plus 2-Zone kit/temperature and Humidity Control Zone Perfect Plus 4-Zone kit/temperature and Humidity Control Zone Perfect Plus 8-Zone kit/temperature and Humidity Control ISO 9001:2000 ama MEETS DOE RESIDENTIAL CONSERVA- TION SERVICES PROGRAM STANDARDS. Befe purchasing this appliance, read imptant energy cost and efficiency infmation available from your retailer. 3 As an ENERGY STAR Partner, Bryant Heating & Cooling Systems has determined that this product meets the ENERGY STAR guidelines f energy efficiency. REGISTERED REGISTERED QUALITY SYSTEM These products are engineered and manufactured under an ISO 9001 registered quality system.

SPECIFICATIONS 024040 036040 024060 036060 048060 036080 RATINGS AND PERFORMANCE Input Btuh Output Capacity BTUH (ICS) Direct Vent (2-Pipe) Upflow 38,000 38,000 56,000 56,000 56,000 75,000 (Shaded capacities are specified Downflow 38,000 38,000 56,000 56,000 56,000 75,000 on rating plate) Hizontal 38,000 38,000 56,000 56,000 56,000 74,000 Non-Direct Vent (1-Pipe) Upflow 38,000 38,000 56,000 56,000 56,000 75,000 Downflow 38,000 38,000 56,000 56,000 56,000 74,000 Hizontal 38,000 38,000 56,000 56,000 56,000 74,000 AFUE Direct Vent (2-Pipe) Upflow 94.3 95.5 93.0 93.0 93.0 93.0 Nonweatherized ICS Downflow 92.9 94 91.5 91.5 91.5 91.5 Hizontal 93.7 94.9 92.3 92.3 92.3 92.3 Non-Direct Vent (1-Pipe) Upflow 93.9 95.1 92.4 Downflow 92.5 93.7 91.4 Hizontal 93.3 94.5 91.4 Certified Temperature Rise Range F 30 60 15 45 45 75 30 60 20 50 40 70 Certified External Static Pressure Heating 0.10 0.10 0.12 0.12 0.12 0.15 Cooling 0.50 0.50 0.50 0.50 0.50 0.50 Airflow CFM Heating 850 1125 885 1065 1320 1190 Cooling 895 1215 900 1200 1545 1245 ELECTRICAL Unit Volts Hertz Phase 115 60 1 Operating Voltage Range Min Max** 104 127 Maximum Unit Amps 6.1 7.3 6.1 7.1 9.5 7.6 Unit Ampacity 8.4 10.0 8.4 9.8 12.8 10.4 Minimum Wire Size 14 14 14 14 14 14 Maximum Wire Length (Ft) 44 37 44 38 29 36 Maximum Fuse Size Ckt Bkr Amps (Time-Delay Fuse Recommended) 15 15 15 15 15 15 Transfmer (24v) 40va External Control Heating 12va Power Available Cooling 21va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control (Off Delay) Selectable 90, 120, 150, 180 Sec Burners (Monopt) 2 2 3 3 3 4 Gas Connection Size 1/2-in. NPT GAS CONTROLS Gas Valve (Redundant) Manufacturer White-Rodgers Min Inlet Pressure (In. wc) 4.5 (Natural Gas) Max Inlet Pressure (In. wc) 13.6 (Natural Gas) Ignition Device Hot Surface BLOWER DATA Direct-Drive Mot HP (Permanent Split Capacit) 1/5 1/3 1/5 1/3 1/2 1/3 Mot Full Load Amps 4.9 5.8 4.9 5.8 7.9 5.8 RPM (Nominal) Speeds 1075 3 1075 4 1075 3 1075 4 Blower Wheel Diameter x Width (In.) 10 x 6 10 x 7 10 x 6 10 x 7 11 x 8 10 x 7 Filter Size (In.) Permanent Washable (1) 16 x 25 x 1 FACTORY-AUTHORIZED AND LISTED, DEALER-INSTALLED OPTIONS Gas Conversion Kit Natural-to-Propane KGANP4001ALL Gas Conversion Kit Propane-to-Natural KGAPN3301ALL Twinning Kit N/A KGATW0601HSI# Manufactured (Mobile) Home Kit KGAMH0102KIT Downflow Base*** KGASB0201ALL Vent Termination Kit (Bracket Only f 2 Pipes) 2-in. KGAVT0101BRA aaaa3-in. KGAVT0201BRA Vent Termination Kit (Single Exit) 2-in. KGAVT0501CVT aaaa3-in. KGAVT0601CVT Condensate Freeze Protection Kit KGAHT0101CFP Condensate Neutralizer Kit (Obtained thru RCD) P908-0001 Electronic/Mechanical Air Cleaner Model EACB, EZXCAB FILCAB Humidifier Model HUM Heat/Energy Recovery Ventilat Model HRV, ERV UV Lights Model UVL Vent/Exhaust Pipe External Trap Kit KGAET0106ETK Do Gasket Kit KGBAC0110DGK See notes on page 5. 4

SPECIFICATIONS Continued 048080 060080 048100 060100 060120 060140 RATINGS AND PERFORMANCE Input Btuh 138,000 Output Capacity BTUH (ICS) Direct Vent (2-Pipe) Upflow 75,000 75,000 94,000 94,000 113,000 129,000 (Shaded capacities are specified Downflow 75,000 75,000 94,000 94,000 113,000 129,000 on rating plate) Hizontal 75,000 75,000 93,000 93,000 112,000 128,000 Non-Direct Vent (1-Pipe) Upflow 75,000 75,000 94,000 94,000 112,000 NA Downflow 75,000 75,000 93,000 93,000 113,000 NA Hizontal 75,000 75,000 93,000 93,000 112,000 NA AFUE Direct Vent (2-Pipe) Upflow 93.0 92.6 Nonweatherized ICS Downflow 91.5 91.2 Hizontal 92.3 92 Non-Direct Vent (1-Pipe) Upflow 92.4 NA Downflow 91.4 NA Hizontal 91.4 NA Certified Temperature Rise Range F 30 60 20 50 45 75 30 60 40 70 50 80 Certified External Static Pressure Heating 0.15 0.15 0.20 0.20 0.20 0.20 Cooling 0.50 0.50 0.50 0.50 0.50 0.50 Airflow CFM Heating 1285 1785 1315 1690 1720 1970 Cooling 1525 1925 1570 1930 2000 1990 ELECTRICAL Unit Volts Hertz Phase 115 60 1 Operating Voltage Range Min Max** 104 127 Maximum Unit Amps 10.0 14.1 10.2 14.8 14.6 14.3 Unit Ampacity 13.4 18.4 13.5 19.3 19.1 18.8 Minimum Wire Size 14 12 14 12 12 12 Maximum Wire Length (Ft) 28 31 27 30 30 30 Maximum Fuse Ckt Bkr Amps (Time-Delay Type Recommended) 15 20 15 20 20 20 Transfmer (24v) 40va External Control Heating 12va Power Available Cooling 21va Air Conditioning Blower Relay Standard CONTROLS Limit Control SPST Heating Blower Control (Off Delay) Selectable 90, 120, 150, 180 Sec Burners (Monopt) 4 4 5 5 6 6 Gas Connection Size 1/2-in. NPT GAS CONTROLS Gas Valve (Redundant) Manufacturer White-Rodgers Min Inlet Pressure (In. wc) 4.5 (Natural Gas) Max Inlet Pressure (In. wc) 13.6 (Natural Gas) Ignition Device Hot Surface BLOWER DATA Direct-Drive Mot HP (Permanent Split Capacit) 1/2 3/4 1/2 3/4 3/4 3/4 Mot Full Load Amps 7.9 11.1 7.9 11.1 11.1 11.1 RPM (Nominal) Speeds 1075 4 Blower Wheel Diameter x Width (In.) 11 x 8 11 x 10 11 x 8 11 x 10 11 x 10 11 x 10 Filter Size (In.) Permanent Washable (1) 16 x 25 x 1 (1) 20 x 25 x 1 (1) 24 x 25 x 1 FACTORY-AUTHORIZED AND LISTED, DEALER-INSTALLED OPTIONS Gas Conversion Kit Natural-to-Propane KGANP4001ALL Gas Conversion Kit Propane-to-Natural KGAPN3301ALL Twinning Kit KGATW0601HSI# N/A Manufactured (Mobile) Home Kit KGAMH0102KIT N/A Downflow Base*** KGASB0201ALL Vent Termination Kit (Bracket Only f 2 Pipes) 2-in. KGAVT0101BRA aaaa3-in. KGAVT0201BRA Vent Termination Kit (Single Exit) 2-in. KGAVT0501CVT aaaa3-in. KGAVT0601CVT Condensate Freeze Protection Kit KGAHT0101CFP Condensate Neutralizer Kit (Obtained thru RCD) P908-0001 Electronic/Mechanical Air Cleaner Model EACB, EZXCAB, FILCAB Humidifier Model HUM Heat/Energy Recovery Ventilat Model HRV, ERV UV Lights Model UVL Vent/Exhaust Pipe External Trap Kit KGAET0106ETK Do Gasket Kit KGBAC0110DGK * Gas input ratings are certified f elevations to 2000 ft. F elevations above 2000 ft, reduce ratings 2% f each 1000 ft above sea level. In Canada, derate the unit 5% from 2000 to 4500 ft above sea level. Capacity and AFUE in accdance with U.S. Government DOE test procedures effective November 10, 1997. Airflow shown is f only return-air supply with facty-supplied 1-in. washable filter(s). F air delivery above 1800 CFM, see Air Delivery table f other options. An airflow reduction of up to 7% may occur when using the facty-specified 4 5/16-inch wide, high efficiency media filter. F best furnace efficiency when using the 4 5/16-inch wide media filter, adjust the blower speed tap to near the mid-point of the rise range. ** Permissible voltage limits f proper furnace operation. Unit ampacity = 125% of largest component s full load amps plus 100% of all other potential operating components (EAC, humidifier, etc.). Length shown is measured 1 way along wire path between unit and service panel f maximum 2% voltage drop. *** Required f installation on combustible flos when no coil box is used, when any coil box other than a Bryant CD5 CK5 cased coil is used. N/A Not applicable ICS Isolated Combustion System # Per 4 tons and 5 tons airflow sizes only (except 060140 size unit) see kit installation instructions f details. 5

COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT/2-PIPE (ALL SIZES) AND /1-PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS MAXIMUM ALLOWABLE PIPE LENGTH (FT) 0 to 2000 2001 to 3000 3001 to 4000 See notes at end of table 138,000 138,000 138,000 2 Pipe 3-in 2 Pipe 3-in 1 1 5 NA NA NA NA NA 1-1/2 1-1/2 70 70 65 60 60 55 2 2 70 70 70 70 70 70 1-1/2 1-1/2 20 15 10 5 NA NA 2 2 70 70 70 70 70 70 1-1/2 1-1/2 10 NA NA NA NA NA 2 2 55 50 35 30 30 20 2-1/2 2-1/2 70 70 70 70 70 70 2 2 5 NA NA NA NA NA 2-1/2 2-1/2 40 30 20 20 10 NA 3 3 70 70 70 70 70 70 2-1/2 one disk 2-1/2 10 NA NA NA NA NA 3 NA 45 40 35 30 25 20 3 nodisk 3 70 70 70 70 70 70 2-1/2 one disk NA 5 NA NA NA NA NA 3 onedisk NA 40 35 30 25 20 15 3 nodisk NA 60 56 52 48 44 40 4 no disk NA 70 70 70 70 70 70 2 Pipe 3-in 1-1/2 1-1/2 67 62 57 52 52 47 2 2 70 70 70 70 70 70 1-1/2 1-1/2 17 12 7 NA NA NA 2 2 70 67 66 61 61 61 2 2 49 44 30 25 25 15 2-1/2 2-1/2 70 70 70 70 70 70 2-1/2 2-1/2 35 26 16 16 6 NA 3 3 70 70 70 70 66 61 3 NA 14 9 NA NA NA NA NA 3 63 62 62 61 61 61 3 nodisk NA 70 70 63 56 50 43 4 no disk 4 nodisk 70 70 70 70 70 70 3 onedisk NA 20 15 10 5 NA NA 3 nodisk NA 39 35 31 27 23 19 4 no disk NA 70 70 70 70 70 70 (IN)* 1-1/2 1-1/2 64 59 54 49 48 43 2 2 70 70 70 70 70 70 1-1/2 1-1/2 16 11 6 NA NA NA 2 2 68 63 62 57 57 56 2 2 46 41 28 23 22 13 2-1/2 2-1/2 70 70 70 70 70 70 2-1/2 2-1/2 33 24 15 14 5 NA 3 3 70 70 70 66 61 56 3 nodisk NA 65 58 51 44 38 31 NA 3 59 59 58 57 57 56 4 no disk 4 no disk 4 nodisk 70 70 70 70 70 70 3 onedisk NA 11 6 NA NA NA NA 3 nodisk NA 30 26 22 18 14 10 4 no disk NA 70 70 70 70 70 70 6

COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT/2-PIPE (ALL SIZES) AND /1-PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED) 4001 to 5000 5001 to 6000 6001 to 7000 See notes at end of table 138,000 138,000 138,000 2 Pipe 3-in 2 Pipe 3-in 1-1/2 1-1/2 60 55 50 45 44 39 2 2 70 70 70 70 70 70 1-1/2 1-1/2 15 10 5 NA NA NA 2 2 64 59 58 53 52 52 2 2 44 39 26 21 20 11 2-1/2 2-1/2 70 70 70 70 70 70 2-1/2 2-1/2 31 22 13 12 NA NA 3 3 70 70 67 62 57 52 3 nodisk NA 53 46 40 33 26 20 NA 3 56 55 54 53 52 52 4 no disk 4 nodisk 70 70 70 70 70 70 3 nodisk NA 21 17 13 9 5 NA 4 no disk NA 69 64 59 54 49 44 2 Pipe 3-in 1-1/2 1-1/2 57 52 47 42 40 35 2 2 70 70 70 70 70 70 1-1/2 1-1/2 14 9 NA NA NA NA 2 2 60 55 54 49 48 47 2 2 41 36 23 18 17 8 2-1/2 2-1/2 70 70 70 70 70 70 2-1/2 2-1/2 29 21 12 11 NA NA 3 3 70 67 62 57 52 47 3 nodisk NA 42 35 29 22 15 9 NA 3 53 52 50 49 48 47 4 no disk 4 nodisk 70 70 70 70 70 70 3 nodisk NA 12 8 NA NA NA NA 4 no disk NA 42 37 32 27 22 17 (IN)* (IN)* 1-1/2 1-1/2 53 48 43 38 37 32 2 2 70 70 68 67 66 64 1-1/2 1-1/2 13 8 NA NA NA NA 2 2 57 52 50 45 44 43 2 2 38 33 21 16 15 6 2-1/2 2-1/2 70 70 68 67 66 64 2-1/2 2-1/2 27 19 10 9 NA NA 3 3 68 63 58 53 48 43 3 nodisk NA 31 24 18 11 NA NA NA 3 49 48 47 45 44 43 4 no disk 4 nodisk 70 70 70 70 67 62 4 no disk NA 17 12 7 NA NA NA 7

COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT/2-PIPE (ALL SIZES) AND /1-PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED) 7001 to 8000 8001 to 9000 9001 to 10,000 2 Pipe 3-in 138,000 NA 2 Pipe 3-in 1-1/2 1-1/2 49 44 39 34 33 28 2 2 66 65 63 62 60 59 1-1/2 1-1/2 12 7 NA NA NA NA 2 2 53 48 46 41 40 38 2 2 36 31 19 14 12 NA 2-1/2 2-1/2 66 65 63 62 60 59 2-1/2 2-1/2 25 17 8 7 NA NA 3 3 63 58 53 48 43 38 3 nodisk NA 20 13 7 NA NA NA NA 3 46 44 43 41 40 38 4 no disk 4 nodisk 61 56 51 46 41 36 138,000 NA 2 Pipe 3-in 1-1/2 1-1/2 46 41 36 31 29 24 2 2 62 60 58 56 55 53 1-1/2 1-1/2 11 6 NA NA NA NA 2 2 49 44 42 37 35 34 2 2 33 28 17 12 10 NA 2-1/2 2-1/2 62 60 58 56 55 53 2-1/2 2-1/2 23 15 7 5 NA NA 3 3 59 54 49 44 39 34 3 nodisk NA 10 NA NA NA NA NA NA 3 43 41 39 37 35 34 4 no disk 4 nodisk 35 30 25 20 15 10 138,000 NA 1-1/2 1-1/2 42 37 32 27 25 20 2 2 57 55 53 51 49 47 2 2 45 40 38 33 31 29 2 2 30 25 14 9 7 NA 2-1/2 2-1/2 57 55 53 51 49 47 2-1/2 2-1/2 21 13 5 NA NA NA 3 3 54 49 44 39 34 29 NA 3 39 37 35 33 31 29 4 no disk 4 nodisk 10 5 NA NA NA NA *Disk usage-unless otherwise specified, use perfated disk assembly (facty-supplied in loose parts bag). If one disk is stated, separate 2 halves of perfated disk assembly and use shouldered disk half. When using shouldered disk half, install screen side toward inlet box. Wide radius elbow. Vent sizing f Canadian installations over 4500 ft (1370 m) above sea level are subject to acceptance by the local authities having jurisdiction. NA-Not Allowed; pressure switch will not make. NOTES: 1. Do not use pipe size greater than those specified in table incomplete combustion, flame disturbance, flame sense lockout may occur. 2. Size both the combustion-air and vent pipe independently, then use the larger diameter f both pipes. 3. Assume two 45 elbows equal one 90 elbow. Wide radius elbows are desirable and may be required in some cases. 4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length elbow count. 5. The minimum pipe length is 5 ft f all applications. 6. Use 3-in. diameter vent termination kit f installations requiring 4-in diameter pipe. 8

MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH AND WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT* 024040 036040 024060 036060 048060 036080 048080 060080 048100 060100 060120 060140 WINTER DESIGN TEMPERATURE ( F) MAX PIPE DIAMETER (IN.) WITHOUT INSULATION WITH 3/8-IN. OR THICKER INSULATION 20 1-1/2 51 70 0 1-1/2 28 70 20 1-1/2 16 70 20 2 65 70 0 2 35 70 20 2 20 70 20 2-1/2 70 70 0 2-1/2 47 70 20 2-1/2 28 70 20 3 70 70 0 3 50 70 20 3 28 70 20 4 70 70 0 4 48 70 20 4 23 70 20 4 70 70 0 4 57 70 20 4 30 70 * Pipe length (ft) specified f maximum vent pipe lengths located in unconditioned spaces. Vent pipes located in unconditioned space cannot exceed the total allowable pipe length as specified in Maximum Allowable Pipe Length table. Insulation thickness based on R value of 3.5 per in. 9

CONDENSATE TRAP BLOWER SHELF CONDENSATE TRAP (INSIDE) DOOR CONDENSATE TRAP SIDE DOOR SIDE 4 7 8 4 5 3 4 5 3 4 4 ALTERNATE DRAIN TUBE LOCATION CONDENSATE TRAP DRAIN TUBE LOCATION UPFLOW APPLICATIONS FIELD DRAIN CONN 26 1 4 1 26 1 1 2 FIELD 4 DRAIN CONN SIDE VIEW FRONT VIEW END VIEW FRONT VIEW DOWNFLOW AND ALTERNATE EXTERNAL UPFLOW APPLICATIONS 3 4 HORIZONTAL APPLICATIONS 3 4 SLOT FOR SCREW HORIZONTAL APPLICATION (OPTIONAL) 1 1 2 1 4 OD COLLECTOR BOX TO TRAP RELIEF PORT 1 2 OD INDUCER HOUSING DRAIN CONNECTION WIRE TIE GUIDES (WHEN USED) 1 3 4 7 8 7 1 8 2 1 4 5 8 OD COLLECTOR BOX DRAIN CONNECTION SCREW HOLE FOR UPFLOW OR DOWN- FLOW APPLICATIONS (OPTIONAL) 1 2-IN. PVC OR CPVC FRONT VIEW SIDE VIEW A93026 10

ACCESSORIES CONCENTRIC VENT FOR DIRECT VENT (2-PIPE) APPLICATION (ALL MODEL SIZES) MEDIA FILTER CABINET B IN. DIA PVC VENT/EXHAUST F 23 5 /8" 23 3 /8" 25 5 /8" 24 3 /8" Opening with Flanges Bent 23 1 /8" Opening E A B Opening 1 1 /2 1 3 /16 C IN. DIA D Furnace Side 23 3 /4" Centerline Screw Slots 5 3 /4" Duct Side Media Filter Cabinet A B 16" 17" 16" 20" 21" 20" Shipped with sizes 024040, 036040, 024060, 036060, 048060, 036080, 048080 060080, 048100, 060100 A B IN. DIA PVC INTAKE/COMBUSTION AIR A97110 24" 25" 24" 060120, 060140 A05218 DIMENSIONS (In.) PART NO. A* B C D E F KGAVT0501CVT 33-3/8 2 3-1/2 16-5/8 6-1/4 5-3/4 KGAVT0601CVT 38-7/8 3 4-1/2 21-1/8 7-3/8 6-1/2 * Dimension A will change accdingly as dimension D is lengthened shtened. Dimension D may be lengthened to 60 in. maximum. Dimension D may also be shtened by cutting the pipes provided in the kit to 12 in. minimum. NOTE: See furnace Installation Instructions when venting multiple furnaces near each other. ACCESSORY DOWNFLOW SUBBASE FIELD-SUPPLIED 2-IN. DIAMETER PVC 90 ELBOW FIELD-SUPPLIED 2-IN. DIAMETER PVC PIPE A COMBUSTION-AIR DISC (FACTORY-SUPPLIED IN LOOSE PARTS BAG) A96211 LENGTH OF STRAIGHT PIPE PORTION OF COMBUSTION AIR INLET PIPE ASSEMBLY (IN.) CASING WIDTH A 17-1/2 8-1/2 ± 1/2 21 10-1/2 ± 1/2 24-1/2 12 ± 1/2 11

ACCESSORY DOWNFLOW SUBBASE LOCATING TAB B 1 1 / 4 TYP PLENUM OPENING LOCATING TAB D 1 2 3 4 A ;; Disassembled 4 3 2 1 A88207 FACTORY-SUPPLIED FIELD-INSTALLED INSULATION Assembled C A97427 CASING WIDTH 17-1/2 21 24-1/2 IN DOWNFLOW APPLICATION Furnace with without Cased Coil Assembly Coil Box Furnace with without Cased Coil Assembly Coil Box Furnace with without Cased Coil Assembly Coil Box PLENUM OPENING* FLOOR OPENING HOLE NO. FOR WIDTH A B C D ADJUSTMENT 15-1/8 19 16-3/4 20-3/8 3 18-5/8 19 20-1/4 20-3/8 2 22-1/8 19 23-3/4 20-3/8 1 * The plenum should be constructed 1/4 in. smaller in width and depth than the plenum dimensions shown above. 12

AIR DELIVERY CFM (With Filter)* 024040 RETURN-AIR SUPPLY SPEED Med- EXTERNAL STATIC PRESSURE (In. wc) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1075 850 740 1040 825 700 995 780 650 945 740 620 895 685 565 840 635 515 760 560 455 670 480 385 036040 Med- Med- 1470 1315 1125 930 1415 1280 1110 925 1400 1235 1085 910 1285 1180 1045 850 1215 1115 990 830 1120 1035 915 770 995 930 830 705 890 825 740 635 024060 Med- 1100 890 745 1065 865 710 1005 810 670 945 765 625 900 705 565 805 620 505 730 540 425 610 475 360 036060 048060 Med- Med- Med- Med- 1430 1270 1070 915 1700 1500 1325 1205 1375 1260 1055 895 1695 1465 1295 1170 1325 1215 1045 885 1640 1435 1265 1145 1275 1160 1015 865 1580 1385 1230 1110 1200 1105 975 840 1545 1355 1190 1080 1135 1035 920 800 1450 1300 1150 1035 1040 950 850 720 1380 1250 1105 990 935 850 750 650 1310 1185 1050 950 036080 Med- Med- 1535 1395 1200 1040 1470 1350 1175 1020 1405 1300 1125 990 1330 1225 1065 960 1245 1155 1030 910 1160 1080 970 860 1065 985 890 785 935 880 780 680 048080 Med- Med- 1750 1495 1310 1135 1685 1455 1260 1105 1635 1405 1225 1075 1575 1355 1170 1040 1525 1305 1125 995 1445 1250 1095 995 1380 1185 1040 910 1310 1120 980 860 060080 both sides and Med- Med- Med- 2200 2100 1815 1560 2360 1965 2175 2025 1760 1555 2280 1925 2085 1945 1720 1515 2210 1870 2025 1865 1670 1460 2130 1830 1925 1785 1620 1435 2035 1760 1820 1700 1550 1390 1960 1710 1735 1620 1480 1340 1875 1670 1635 1540 1405 1270 1790 1575 048100 Med- Med- 1740 1500 1340 1195 1705 1470 1315 1175 1660 1445 1300 1165 1615 1410 1270 1130 1570 1375 1235 1100 1500 1330 1200 1070 1425 1280 1140 1030 1355 1210 1095 975 060100 both sides and Med- Med- Med- 2250 2020 1725 1490 2360 1960 2175 1950 1690 1480 2315 1940 2090 1900 1660 1460 2265 1930 2020 1840 1630 1440 2200 1900 1930 1790 1575 1380 2130 1850 1855 1710 1520 1340 2055 1800 1760 1640 1460 1295 1965 1740 1670 1545 1370 1230 1890 1660 060120 060140 only both sides and only only both sides and only Med- Med- Med- Med- Med- Med- Med- Med- 2350 2100 1770 1545 2435 2040 2255 1985 2285 2020 1675 1460 2310 1975 2140 1930 2250 2015 1720 1520 2360 2000 2190 1930 2210 1970 1650 1445 2255 1945 2080 1850 2160 1955 1675 1465 2285 1950 2115 1890 2140 1920 1620 1430 2185 1900 2025 1800 2070 1875 1620 1415 2220 1905 2045 1840 2065 1870 1590 1400 2120 1860 1945 1740 2000 1810 1575 1365 2130 1835 1965 1780 1990 1805 1560 1370 2045 1835 1875 1725 1885 1710 1515 1325 2050 1790 1890 1720 1910 1730 1510 1320 1965 1775 1795 1660 1790 1650 1450 1265 1965 1725 1800 1645 1830 1660 1450 1275 1880 1720 1725 1580 1635 1540 1365 1185 1875 1650 1710 1560 1745 1590 1390 1230 1800 1640 1625 1495 * Airflow shown is f only return-air supply with facty-supplied 1-in. washable filter(s). F air delivery above 1800 CFM, see Air Delivery table f other options. An airflow reduction of up to 7% may occur when using the facty-specified 4 5/16-inch wide, high efficiency media filter. F best furnace efficiency when using the 4 5/16-inch wide media filter, adjust the blower speed tap to near the mid-point of the rise range. F hizontal and downflow applications, use only as an airflow reference. 13

OUTDOOR UNIT COMBUSTION AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) A/C COIL VENT PIPE HUMIDIFIER COMBUSTION AIR INLET (NON-DIRECT 1-PIPE APPLICATION) ELECTRONIC AIR CLEANER GAS-FIRED WATER HEATER AIRFLOW FRONT OF A05064 ELECTRONIC AIR CLEANER VENT COMBUSTION AIR INLET (NON-DIRECT VENT/ 1-PIPE APPLICATION HUMIDIFIER COMBUSTION AIR (DIRECT VENT/ 2 PIPE APPLICATION OUTDOOR UNIT A/C COIL FRONT OF AIRFLOW A05065 14

COMBUSTION-AIR INLET (/1-PIPE APPLICATION) VENT PIPE COMBUSTION AIR PIPE DIRECT VENT/2-PIPE APPLICATION) ELECTRONIC AIR CLEANER FRONT OF CONDENSATE DRAIN REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW A05066 COMBUSTION - AIR INLET (/ 1-PIPE APPLICATION) COMBUSTION AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) VENT PIPE REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW CONDENSATE DRAIN FRONT OF ELECTRONIC AIR CLEANER A05067 15

Legacy Plus 90 Single-Stage/Deluxe Gas Furnace GENERAL System Description Furnish a (4-way multipoise) fixed capacity gas-fired condensing furnace f use with natural gas propane (facty authized conversion kit required f propane); furnish cold air return plenum; furnish external medial cabinet f use with accessy media filter standard filter. Quality Assurance Unit will be designed, tested and constructed to the current ANSI Z 21.47/CSA 2.3 design standard f gas-fired central furnaces. Unit will be 3rd party certified by CSA to the current ANSI Z 21.47/CSA 2.3 design standard f gas-fired central furnaces. Unit will carry the CSA Blue Star and Blue Flame labels. Unit efficiency testing will be perfmed per the current DOE test procedure as listed in the Federal Register. Unit will be certified f capacity and efficiency and listed in the latest GAMA Consumer's Directy of Certified Efficiency Ratings. Unit will carry the current Federal Trade Commission Energy Guide efficiency label. Delivery, Stage, and Handling Unit will be shipped as single package only and is sted and handled per unit manufacturer's recommendations. Warranty (f inclusion by specifying engineer) U.S. and Canada only. Warranty certificate available upon request. PRODUCTS Equipment Components shall include: slow-opening gas valve to reduce ignition noise, regulate gas flow, with electric switch gas shut-off; flame proving sens, hot surface igniter, pressure switch assembly verifies inducer operation; flame rollout switch, drain tubing and installed condensate drain trap, blower and inducer assembly, 40va transfmer; low-voltage (heating) (heating/ cooling) thermostat. Blower Wheel and Blower Mot Galvanized blower wheel shall be centrifugal type, statically and dynamically balanced. Blower mot of PSC type shall be permanently lubricated with sealed bearings, of hp, and shall be multiple-speed direct drive. Blower mot shall be soft mounted to the blower scroll to reduce vibration transmission. Filters Furnace shall have reusable-type filters. Filter shall be in (x) in. An accessy high efficiency Media Filter is available as an option. Media Filter. GUIDE SPECIFICATIONS Casing Casing shall be of.030 in. thickness minimum, pre-painted galvanized steel. Inducer Mot Inducer mot shall be soft mounted to reduce vibration transmission. Primary Heat Exchangers Primary Heat exchangers shall be 3-Pass 20 gauge crosion resistant aluminized steel of fold-and-crimp sectional design, which operates under negative pressure. Secondary Heat Exchangers Secondary Heat exchangers shall be of a flow-through design having a patented interi laminate coating of polypropylene f greater crosion resistance with fold-and-crimp design, which operates under negative pressure. Controls Controls shall include a microprocess based integrated electronic control board with at least 11 service troubleshooting codes displayed via diagnostic flashing LED light on the control, has ability to ste fault codes, when activated a self-test feature checks all maj functions of the furnace within one minute, and a replaceable automotive-type circuit protection fuse. Multiple operational settings available including separate blower speeds. Cooling airflow will be selectable between 350 400 CFM per ton of air conditioning. Features will also include tempary reduced airflow in the cooling mode f improved dehumidification when a Thermidistat is selected as the thermostat. Operating Characteristics Heating Capacity shall be Btuh input; Btuh output capacity. Fuel Gas Efficiency shall be 93% AFUE. Air delivery shall be cfm minimum at 0.50 in. wg. external static pressure. Dimensions shall be: depth in.; width in.; height in. (casing only). Height shall be in. with A/C coil and in. overall with plenum. Electrical Requirements Electrical supply shall be 115 volts, 60 Hz, single-phase (nominal). Minimum wire size shall be AWG; maximum fuse size HACR-type, designated circuit breaker shall be Amps. Special Features Refer to section of the product data sheet identifying accessies and descriptions f specific features and available enhancements. Bryant Heating & Cooling systems 7310 W. Mris St. Indianapolis, IN 46231 Printed in U.S.A. edition date: 01/06 Catalog No. PDS 350A.40.1 RA Manufacturer reserves the right to change, at any time, specifications designs without notice and obligations 16 Replaces: PDS 350A.40.1