J. LINES, Graham Corp., Batavia, New York

Similar documents
Figure 1. Ejector cross-sectional drawing. Figure 2. Precondenser to left of vacuum flasher. pressure.

Reliable Vacuum Condenser Performance

International Association of Certified Practicing Engineers

Understanding Process Vacuum for Process Improvement

Optimization of Hybrid Noncondensable Gas Removal System for a Flash Steam Geothermal Power Plant

CHAPTER 7 COMPARISON OF HEAT EXCHANGERS

KBC Petro-SIM Design Tools Integrated Equipment Operations. Al Shelton - KBC

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence

Compression of Fins pipe and simple Heat pipe Using CFD

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

No matter how adventurous a process engineer may

Jet ejectors for the oil industries. Vacuum solutions for refineries and the petrochemical industries

(Refer Slide Time: 00:00:40 min)

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

Vacuum distillation APPLICATION REPORT

Evaporators. Direct Expansion Flooded Recirculated Over Feed

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Points to be Considered when Purchasing a Steam Jet Vacuum Pump

Published in Heat Transfer Engineering Vol. 20, No

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

How is the heat transfer?

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

Evaporation studied on a duplicated vessel, pilot scale evaporator equipped with a heat pump

Evaporation is a unit operation that separates a liquid

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

The Condensate Water Systems

Heat Exchangers. Heat Exchangers 1

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments

DEVELOPING INDUSTRIAL CRYSTALLIZATION SYSTEMS USING ESP SOFTWARE DON GENIESSE SWENSON TECHNOLOGY

Vacuum Booster for Distillation Process

Chapter 5 Heat-transfer Equipment

2. HEAT EXCHANGERS MESA

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

In order to be useful, many substances must be available in pure form.

Shyam Enterprises 9 PACKAGE UNIT

Shale Oils Designing for Improved Crude Preheat Train Reliability and Performance

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

HEAT EXCHANGER FORMULAS & EXAMPLE

CHAPTER 8 EVAPORATION. The basic factors that affect the rate of evaporation are the:

Paper No. : 04 Paper Title: Unit Operations in Food Processing Module- 14:Evaporation

OURSE TITLE : MASS TRANSFER OPERATIONS 1 COURSE CODE : 5071 COURSE CATEGORY : A PERIODS/ WEEK : 4 PERIODS/ SEMESTER : 52 CREDIT : 4 TIME SCHEDULE

System Modeling of Gas Engine Driven Heat Pump

2007 KBC Advanced Technologies plc. All Rights Reserved.

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Drying principles and general considerations

EJECTOR PROCESS VACUUM SYSTEMS BULLETIN # PVS EVS

USING THE P-T CARD AS A SERVICE TOOL

POWERENERGY

As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists

CL4001 HEAT TRANSFER OPERATIONS

GESTRA Information A 1.7

Dynamics of Solid Bed Dehydration in a Niger Delta Natural Gas Liquids Plant

Modeling Solids Dryers and Granulators with Aspen Plus V8

The Complete Guide to Gas Sample Drying for Your Analyzer or Process

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Economical and simplified solutions that offer quality and optimum steam trap service.

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

Removal of Non-condensable Gases and Air Is Critical In A Steam System

Steam Trap Inspection Methods And Steam Cost Analysis

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

SOFTWARE DEVELOPMENT FOR MECHANICAL DESIGN OF SHELL AND TUBE HEAT EXCHANGER

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

A formula for success

MECHANICAL SCIENCE Module 2 Heat Exchangers

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

Economical analysis between Vacuum system with ejectors and VS with liquid ring pump

ω = (1) Kirby S. Chapman Ph.D.

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Real Time Pipeline Leak Detection on Shell s North Western Ethylene Pipeline

A M E M B E R O F T H E K E N D A L L G R O U P

VACUUM TOWER WASH SECTION DESIGN: MYTH AND REALITY

R-407A R-448A R-449A

OPTIMISE VACUUM TO IMPROVE PLANT PERFORMNCE

Process Simulation and Optimization of Cryogenic Operations Using Multi-Stream Brazed Aluminum Exchangers

the NC gases and the partial pressure Pv of the water vapor. Then, (1) Pt = Pnc + Pv Also, M v M nc

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Abnormal Situation Management: Detection of Fouling and Longitudinal Bypass in Heat Exchangers

Capital Cost Reduction by the Use of Divided Wall Distillation Column

ecodry Figure 1 - Process Diagram ecodry B General Process Description

E. Baffle Tray Column (or, Termed Shower Deck, No Holes, Caps, or Other Contact Devices)

STEAM AND TRAP FUNDAMENTALS

LIQUID REFRIGERANT CONTROL IN REFRIGERATION AND AIR CONDITIONING SYSTEMS

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

PROCESS & MECHANICAL DESIGN FOR DISTILLATION COLUMN RELIABILITY

c. 13,000 gallons/minute to m3/day

MACH CI. (Condensing-Indirect) Water Heating

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

All rights reserved, Armando B. Corripio, PhD, PE, Solid Dryer Design Introduction Continuous Dryer Design...

THE SIGNIFICANCE OF RELIABLE PRESSURE CONTROL IN OILFIELD BURNER SYSTEMS

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Efficient Steam System Design

LOW-NOX BURNER RETROFIT CHALLENGE

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Cascade Refrigeration System for LPG Subcooling. Related Technical Data and Information for the Case:

Transcription:

Originally appeared in: January 2017, pgs 77-81. Used with permission. Process Engineering J. LINES, Graham Corp., Batavia, New York Key design considerations for vacuum process condensers The crude oil refining and petrochemical industries make extensive use of condensers that operate under vacuum (i.e., below atmospheric pressure). Distillation is the most common process using these condensers, either as a process precondenser ahead of an ejector system, or as an intercondenser within an ejector system. Proper operation of a vacuum condenser is essential for distillation process throughput and/or fractionation. When these condensers perform poorly, it can become a major issue for the refiner or petrochemical plant because profit loss is significant when distillation product quality is inferior, or when throughput is scaled down to maintain process quality. Vacuum condenser design is challenging because available software for modeling performance is inadequate and unreliable. Therefore, reliance on know-how and proven experience from ejector and process vacuum technology providers is important. Here, important considerations are proposed for developing purchase specifications, evaluating designs, selecting an appropriate supplier and considering what may be causing under-performance. and to permit continual extraction of noncondensibles (FIG. 1). Several distinct differences between vacuum condensers and conventional S&THEs exist: Open areas above the tube bundle that permit flow distribution and reduce pressure loss Lack of conventional flow directing segmental or double-segmental baffling, which reduces pressure loss and appropriately manages vapor-liquid equilibrium Extraction of noncondensible gases within a tube bundle (FIG. 2). Heat release data. To properly design a vacuum condenser, it is important to understand the compositional makeup of the process load and shape of the heat release curve (i.e., how condensing takes place as the process vapors are cooled). Often, the shape of the heat release curve informs the engineer designing or evaluating the design of a vacuum condenser about what elements are critical to ensure proper performance. The effect of noncondensible loading is always important. Two important considerations should be taken into account for noncondensible FIG. 1. Process vacuum condenser serving a distillation process for nylon intermediate production. Vacuum condenser. Externally, a vacuum condenser may appear to be an ordinary shell and tube heat exchanger (S&THE). It has similar construction features that follow Tubular Exchanger Manufacturer Association (TEMA) or American Petroleum Institute (API) 660 guidelines; however, the internal configuration is different due to its operation under a vacuum, its condensing of vapors with noncondensibles and its handling of miscible condensates to ensure correct vapor-liquid equilibrium FIG. 2. Cross-section of a TEMA X shell vacuum condenser with a longitudinal baffle for venting noncondensibles.

gas loading in a vacuum condenser. The first is suppression of efficient heat transfer caused by the gases that lower the overall heat transfer coefficient. The greater the percentage of noncondensible gases in the process load, the lower the overall heat transfer coefficient. As vapors condense along the heat release curve, the percentage of noncondensibles increases correspondingly. Secondly, the presence of noncondensible gases will lower the effective log mean temperature difference (LMTD). For example, a pure component will condense isothermally and, therefore, will have a maximum effective LMTD. Alternatively, under the same conditions but with 10% of the load being noncondensible gas, such as air the LMTD is lower. Both a lower LMTD and overall heat transfer Temperature, F 150 140 130 120 110 100 90 80 70 0 Log mean temperature difference 0 lb/hr air load 49 F 250 lb/hr air load 47 F 500 lb/hr air load 45.1 F 750 lb/hr air load 43.1 F 500,000 1,00,000 1,500,000 Heat rejection, Btu/hr coefficient result in greater surface area for the vacuum condenser. FIG. 3 illustrates an example where pure steam is condensed, and the LMTD and overall heat transfer rate are compared under varying amounts of air loading. In a comparison of the case of pure steam without air loading, the required vacuum condenser surface area is 150 ft 2. A case with 750 pph of air load along with steam will require 275 ft 2. Heat release data for crude oil refining processes whether for vacuum distillation column, ultra-low-sulfur diesel (ULSD), lube oil fractionation or hydrodesulfurization service are usually given with a grouping of lighterend cracked gases that are classified as noncondensible gases, steam (when stripping or fired heater velocity steam applies) and petroleum fractions or Heat transfer rate 370 Btu/hr ft 2 F 250 Btu/hr ft 2 F 215 Btu/hr ft 2 F 0 lb/hr air 190 Btu/hr ft 2 F 250 pph air 500 lb/hr air 750 lb/hr air 2,000,000 2,500,000 3,000,000 FIG. 3. Effect on LMTD and heat transfer rate from increases in noncondensible loading. Chart shows 2,500 lb/hr of steam condensing with differing air loads. Pressure is 3 psia and cooling water is 80 F at inlet and 100 F at outlet. Temperature, F 350 300 250 200 150 100 50 0 0 2,000,000 Process vapors Pseudocomponents condense throughout the cooling curve with lowest normal boiling point fractions meaningfully condensing below 180 F Cooling water 4,000,000 6,000,000 8,000,000 10,000,000 12,000,000 14,000,000 Duty, Btu/hr FIG. 4. Heat release curve for ULSD process vacuum precondenser. Pressure is 6 psia isobaric heat release, loading is petroleum fractions with steam and noncondensibles, and LMTD is 74 F. pseudocomponents with varying normal boiling points. An example for a ULSD process is detailed in TABLE 1. Inspection of the heat release curve (FIG. 4) infers that the pseudocomponent petroleum fractions condense along the cooling curve, as might be anticipated. A critical consideration is that vaporliquid equilibrium (and, therefore, heat release profile) assumes that the vapors and liquids remain in contact and at the same temperature throughout the heat exchanger. The pseudocomponents form miscible condensates. The amount of a pseudocomponent condensed at a given temperature along the cooling curve will depend on its partial pressure, which is a function of its vapor pressure and mole fraction in the condensate (i.e., Raoult s Law). For lower-normal-boiling-point pseudocomponents with greater vapor pressures and generally lower molecular weights, a lower mole fraction in condensate will drive greater condensation. Therefore, it is imperative that the heat exchanger design permit the formed condensate and vapors to remain together throughout the cooling curve; otherwise, predicted vapor-liquid equilibrium will not be achieved. If the condensate is not kept in contact with the vapors due to baffling, which separates the vapors from condensate, then more pseudocomponents will remain in the vapor phase and will not be recovered as condensate, due to the mole fraction in the liquid being greater. This critical process equipment must condense the maximum amount of vapor. Consider two condenser configura- TABLE 1. Process loading to ULSD process vacuum precondenser Component Heat release curve Measurement, lb/hr Steam 300 Noncondensible gases 60 Pseudocomponents 52,000 Normal boiling point breakdown 150 F 200 F 18,400 200 F 300 F 19,500 300 F 400 F 6,500 400 F 500 F 6,000 > 500 F 1,600

tions for the aforementioned ULSD service: a properly designed vacuum condenser keeping the vapors and condensate together in a TEMA X shell configuration; and a segmentally baffled unit with four cross-passes (TEMA E shell) where condensate is removed at each cross-pass and is no longer available in subsequent passes. In the E shell case, condensate is removed at 250 F, 180 F and 150 F due to flow configuration. The objective is to condense the process load from 300 F to 110 F. Two important definitions for the method of condensation and vapor-liquid equilibrium include: Integral condensation: When vapors and condensate remain together throughout the heat release curve Differential condensation: When condensate is removed at intervals along the heat release curve and is no longer available in subsequent intervals. Note: Process simulations regarding vapor-liquid equilibrium and heat release curves are based on integral condensation (TABLE 2). A rigorous stepwise analysis will be required for differential condensation. This analysis will apply when conventional baffling is used. Note the variation in exit conditions between integral and differential condensation (FIG. 5). Differential, in this case, resulted in approximately three times the mass and volumetric flowrate exiting the condenser as vapor. Loading to an ejector downstream of the vacuum condenser is also changed by roughly three orders of magnitude. Consider the effects if a vacuum condenser for the proposed case had been designed for optimum heat transfer using segmental or double-segmental baffling, where differential condensation is applied. Use of the process simulation heat release and vapor-liquid equilibrium information would cause incorrect performance. Process operating pressure would rise due to greater volumetric flowrate, causing higher pressure drop across the condenser. This would also result in higher vapor carried from the condenser to the ejector downstream. Heat transfer companies that specialize in optimum performance may not configure the condenser appropriately to balance TABLE 2. Vacuum condenser process conditions at inlet and outlet comparing integral to differential condensation Outlet conditions Integral Inlet conditions condensation Temperature, F 300 110 110 Steam, lb/hr 301 41 118 Noncondensible gas, lb/hr 60 60 60 52,000 398 1,470 Pseudocomponents vapor phase, lb/hr Pseudocomponents liquid phase, lb/hr 52,000 lb/hr pseudocomponents 6 psia and 300 F 34,600 lb/hr pseudocomponents 180 F 46,600 lb/hr pseudocomponents 250 F 5,400 lb/hr pseudocomponents 250 F Differential condensation in four cross passes 12,000 lb/hr pseudocomponents 180 F 118 lb/hr steam 1,470 lb/hr pseudocomponents 110 F 26,320 lb/hr pseudocomponents 150 F 8,280 lb/hr pseudocomponents 150 F 182 lb/hr water 50,530 lb/hr pseudocomponents 148 F 182 lb/hr water 24,850 lb/hr pseudocomponents 110 F FIG. 5. Schematic representation of differential and integral condensation. efficient heat transfer with low pressure loss; nor may they be able to maintain vapors and liquid in contact throughout the cooling (condensing) curve. In cases where pressure rises above design, field operating measurements may appear to indicate that the process simulation is Integral condensation 52,000 lb/hr pseudocomponents 6 psia and 300 F 41 lb/hr steam 398 lb/hr pseudocomponents 110 F 259 lb/hr water 51,602 lb/hr pseudocomponents 110 F Differential condensation 0 51,602 50,530 Total gas/vapor flowrate, lb/hr 499 1,648 Heat Exchange Institute water 310 980 vapor equivalent, lb/hr Volumetric flowrate, ft 3 /sec 30.4 86.4 TABLE 3. Impact of pseudocomponent characterization on LMTD Pseudocomponents, % Normal boiling point range Design Greater light ends Greater middle ends Typical breakdown 150 F 200 F 35 40 9 15 200 F 300 F 37.5 33 64 25 300 F 400 F 12.5 12.5 12.5 25 400 F 500 F 11.5 11.5 11.5 25 > 500 F 3 3 3 10 Effective LMTD, F 74 66 98 132 incorrect; however, in reality, the vacuum condenser configuration is incorrect. Pressure drop is also important. It has a multiplier effect. Greater pressure drop will lower the LMTD, resulting in greater condenser surface area requirements. It will also reduce the amount of vapors

condensed, thereby increasing the vapor loading to equipment downstream of the vacuum condenser. Consider the aforementioned example: if vapor side pressure drop is 0.3 psi, then the LMTD is 74 F, and 499 lb/hr exit the condenser as load to the downstream equipment. If the pressure drop were 1.2 psi, then the LMTD is 67 F, and 800 lb/hr exit the condenser as load to the downstream equipment. FIG. 6. Shell-side flow arrangements for vacuum condensers. Assessing and characterizing pseudocomponent breakdown of a hydrocarbon mixture require diligence. This breakdown is generally performed via a distillation assay, where boiling point range is determined in a lab for the crude oil. Too often, this lab assessment can be measurably off due to actual distillation column performance caused by stripping efficiency, vapor velocities and crude slate variation. It is common to observe that condensable hydrocarbon exiting a vacuum distillation column is meaningfully above design mass flowrate, and that a greater number of highernormal-boiling-point pseudocomponents are present than the design basis. TABLE 3 shows how variation in pseudocomponent distribution affects the LMTD as a result of changes to the heat release curve, using the ULSD example. A similar situation can be found in petrochemical industries, where process loads are mixtures of petrochemicals, and where steam may form miscible, non-ideally miscible and immiscible condensates, or where chemical reactions occur. A common challenge is found in alcohols, acids, esters or urea processes, where the process load to the vacuum condenser requires integral condensation. Differential condensation, such as that which results from the use of baffling for improving heat transfer, will materially alter the heat release and vapor-liquid equilibrium results. Considerations when specifying or evaluating process vacuum condensers include: 1. Conservatively estimate noncondensible gas load. This is particularly important for refining services where crude slate may vary, or where cracked gases from fired heaters cannot reliably be predicted. Caution: The most common cause of poor performance is incorrectly specifying noncondensible gas loading. 2. Understand the compositional makeup of the process load and assess: Are condensates ideally miscible, immiscible or non-ideally miscible? Are gases soluble in condensate, and to what degree should that be considered? Are the chemical reactions between vapors, gases and condensate exothermic or endothermic? In refining services, accurate process simulation of pseudocomponents is challenging due to the varied crude slates processed, as well as to the assumption of distillation column stripping efficiency. It is important to carefully and conservatively specify the condensable pseudocomponent loading:

1. Use a molecular weight specific to each normal boiling point pseudocomponent. Do not use a constant and equal molecular weight for all pseudocomponents. 2. Run sensitivities to characterize the pseudocomponents and ensure the safest way to specify the pseudocomponents. A greater percentage of higher-normalboiling-point pseudocomponents will generally condense more quickly. Alternatively, a greater percentage of lower-normalboiling-point pseudocomponents will result in less condensing. 3. Bring the vacuum equipment supplier into the discussion early to understand how changes in characterization will impact design. 4. Evaluate the appropriateness of the condenser configuration to ensure that vapor-liquid equilibrium or chemical reaction equilibrium is achieved to match the process simulation for heat and material balance (heat release curve). 5. Provide at least two isobaric heat and material balance simulations, one at the inlet pressure to the condenser and another at 80% 90% of the inlet pressure. 6. Evaluate if condensate should be at the vapor outlet temperature. 7. Perform sensitivity analyses to understand how outlet compositional flow varies with outlet pressure and temperature. Caution: A process vacuum condenser is always part of an overall vacuum producing system. Never evaluate a process vacuum condenser in isolation. Evaluate the complete system, including interdependencies between the vacuum condenser and system components both upstream and downstream of it. 8. If commercially available software or software from research institutions is used, apply a rigorous analysis to validate pressure drop assumptions and outlet composition tied to flow arrangement. Note: At present, no reliable commercial software or software from research organizations are available. Recommendations. Process vacuum condensers are specialized heat exchangers. How they are designed, and what factors should be kept in mind to ensure that the vacuum system (including condensers and ejectors) performs properly, are key to successful operation. These condensers are critical for efficient and reliable process performance. A first step toward successful integration of this type of heat exchanger into a refining or chemical industry process is respect for the important differences between vacuum condensers and process S&THEs. This integration should be followed by a rigorous and deliberate analysis of the design, where coupling heat transfer and mass transfer with low pressure loss configuration is paramount. Process vacuum condensers are used successfully throughout the industry. However, when critical design considerations are not thoroughly analyzed, underperformance and economic loss are certain to result. JIM LINES is an engineer at Graham Corp. in Batavia, New York. He has 33 years of experience in heat transfer and vacuum system design. He holds a BS degree in aerospace engineering from the University of Buffalo in New York. He has authored or coauthored numerous articles in the fields of heat exchanger and ejector system design. Electronic and single printed copies for distribution with permission to Graham Corporation from Hydrocarbon Processing January 2017 Gulf Publishing Company

www.graham-mfg.com Superior Vacuum Column Performance Graham Ejector Systems. No Substitute for Proven Experience. Reliable flash zone pressure Successful global installations Trusted for over 8 decades Efficient energy consumption Technical and quality leadership Exceptional field service and support Go to www.graham-mfg.com/ejector-videos to view our ejector performance videos Select 95 at www.hydrocarbonprocessing.com/rs Graham Corporation, 20 Florence Ave, Batavia, NY 14020 585-343-2216 applicationengineering@graham-mfg.com