SS-100. Pyrometer. Temperature Range: 800~2400

Similar documents
SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500

2-Channel Smoke Detector SD - 110

Multi-Channel Gas Detector Monitoring Unit GMS

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

RS Pro Infrared Temperature Sensor

Innovative Technology for Traditional and Challenging Applications

optris TM Temperature Monitor for Infrared Sensors Operators manual

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

IRT2 Dual Laser IR Thermometer - User Guide

M15-GSL12P30 M15-GSL12P30S Heat Spy Infrared Thermometer User Manual

Infrared Temperature Sensor

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

FIRERAY 5000 range USER GUIDE

Dual Laser InfraRed (IR) Thermometer

Dual Laser InfraRed (IR) Thermometer

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

+ A B V B NO NC V COM PV PV

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Precision Infrared Thermometer. Users Manual

Series Temperature Controller Instruction Sheet


High Temperature InfraRed Thermometer with Laser Pointer

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

R2310. Infrared Thermometer. Instruction Manual

Users Manual. Visit us at

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Improving Quality and Productivity with Non-Contact Temperature

Key Features. General Description

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

User s Guide OS210-C4. IR Temperature Sensors. Shop online at omega.com. For latest product manuals: omegamanual.

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Using the Model 1500 Portable Chilled Mirror Hygrometer

Precision Infrared Thermometer. Users Manual

CTT8 TEMPERATURE MONITOR DEVICE

More Precision. thermometer // Non-contact IR temperature sensors

PRO SERIES NONCONTACT TEMPERATURE SENSORS

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

MO n : 12JMC rév A

Modline. 5 Stand Alone Temperature Sensor. You can bet your process on it!

Gas Detection System TOX ALARM DG2000-Garage

Contents. Photoelectric Sensors / Standard Sensors...4. Safety Sensors Photoelectric Sensors / Miniature Sensors... 12

INSTALLATION AND OPERATION MANUAL FOR THE PYROSIGHT SERIES

UDC 700 Universal Digital Controllers and Indicator Specifications

Datasheet: K-22 LO Sensor

I/R Thermometer Gun 12:1

CTlaser LT/ 1M/ 2M/ CTglass

Danfoss gas detection units

General Specifications

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

CLEANROOM MONITOR CR3A Network - Installation Instructions

Visit us at testo 835 Infrared and contact thermometer

End To End Optical Beam Smoke Detector. Additional Information

Danfoss gas detection unit Type GD Heavy Duty

SPOT HIGH PRECISION PYROMETERS A PRODUCT OF THE SYSTEM 5 FAMILY. 50 to 1800 C / 122 to 3272 F QUALITY CUSTOMER SOLUTIONS

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Motorised Infrared Optical Beam Smoke Detector. User Guide

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Address: 2857 Sherwood Heights Dr. Unit 2, Oakville, ON, Canada. L6J 7J9 Toll free: LOGIKA

Networkable Fan Coil Controller Specification and Installation Instructions

Manual PCE-889 pyrometer

Williamson Pro Series Pyrometer

Instruction Manual CTVM-3H3 CTVM-2L CTVM-2H CTVM-2H1 CTVM-3L CTVM-3H CTVM-3H1 CTVM-3H2 CTVM-1L CTVM-1H CTVM-1H1

Sitron s CF Line of Flow Switch Monitors

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

Motorised Infrared Optical Beam Smoke Detector. User Guide

RTD TEMPERATURE SENSING SYSTEM

User s Guide OS-MINI22 SERIES. Shop online at omega.com SM. For latest product manuals: omegamanual.info

RS485 MODBUS Module 8AI

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Apollo Intelligent Auto Aligning Beam Detector. User Guide

Superdew 3. Hygrometer. Operating Instructions

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

Temperature-Relay TR210

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

F4 Process Controller Installation and Operation Guide

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

User s Guide OS100E SERIES. Mini-Infrared Transmitters. Shop online at omega.com SM

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

E3M-V. Mark Sensor. Applications

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

Manual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

1. Quick start-up guide

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

CMT MANUAL 6. NMC SENSORS

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

Option output. 0 None. 4 RS485 communication output. 0 None. Alarm output. CH2 control output. 0 None. CH1 control output. 0 None

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Using the DewTrak II Dew Point/ Humidity Transmitter

Transcription:

Two Color Non-Contact Pyrometer Temperature Range: 800~2400 SS-100 GasDNA Co.,Ltd C-910C, Bupyeong Woolim Lion s Valley, #425, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507 FAX: +82-32-623-7510 E-mail: sales@gasdna.com Web: www.gasdna.com Cheongcheon-Dong,

1. Features SS-100 non-contact pyrometer is adapting two-color sensor, which make it to measure target object accurately than One-color sensor under a emissivity change. Two-color sensor is using two comparing sensors which have a different wavelength. This sensor can measure target object accurately although it is partially obscured by an obstacle, or smoke in the air, dust, veiled by large dust particles. And it still can be measured accurately when sensor lens is piled up with foreign substances SS-100 non-contact pyrometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) or RS-485 communication signal output, it still provides relay contact for alarm signal. It can measure from 800 to maximum 2400 and user can change a temperature range, it has a high accuracy by adapting optical lens. SS-100 can measure a target in long distance through80:1 D:S (Distance to Spot). Emissivity is 0.75 ~ 1.25 adjustable in two-color mode. Two built-in laser pointers can aim at the target. *Applications: Aluminum, Chrome, Copper, Metal, Magnesium, Oxide-n ickel, Platinum, Gold, Silver, Oxided- Titanium, Zinc, Tin, Steel, Oxided- Steel, Oxided-Brass 2. Ordering information Code Number SS-100- - - L Code A Temperature Range 1 800~1800 2 800~2400 Z Code B M N Other Output DC 0~20mA DC 4~20mA V DC 1~5V Z Code C Other Cable Length 1 3m Cable Z Other Description

3. Accessories Description Shape Usage Remark Fixing nut Sensor fixing nut Basic accessory 4. Product specification Segment Range 800~2400 Accuracy 2 or ±1% Repeatability ±1% of reading Distance : Spot (D:S) 80:1 Wavelength Range 0.8~1.1μm Sensor Type Two color ( Si/Si ) Response Time Within 0.1 sec Emissivity (one color) 0.10~0.99 Emissivity (two color) 0.75~1.25 Analog Output Communication output Relay output 4~20mA, 1~5V(option) RS-485 SS-100 1 step- Relay Contact (High/Low) Power DC 12~24V(Max 200mA) Ambient temperature 0~70 Temperature Resolution 1 Operating Relative Humidity 5~90% Storage Temperature -30~85 Waterproof IP65,NEMA 4 Laser point Housing material Weight Cable length 630~670nm(red) SUS 960 g 3m,other

5. Optical Field of View (D:S= 80:1) 34.2 14.6 5 4.8 0 500 1000 2000 SPOT SIZE [mm] MEASURING DISTANCE A[mm] 6. Laser pointer adjustment [ switch ] To aim a target object, enter the switch. Please press switch for laser pointer on/off.

7. Product description 4 digit display DOWM UP Name UP DOWN UP+DOWN Description - Enter into Set-up Mode. - Move to other menu on setting menu Increase the value of measuring range by 1 unit. When you keep touching it during 5 sec, the value increases fast. Decrease the value of measuring range by 1 unit. When you keep touching it during 5 sec, the value decreases fast. Press UP & DOWN at the same time when want to enter measuring mode from setting menu Store the set value.

8. Wiring No. Wire color Usage 1 Black Power 24VDC(+) 2 Brown Power 0V(-) 3 Red Analog output(+) 4 Orange RS485 A 5 Green RS 485 B 6 Blue Relay Normal close 6 Purple Relay Common 7 Grey Relay Normal open

9. Menu (PARAMETERIZING) <1> 800 <2> [mono && Colr ] & SAVE <3> Emis 0.75 ~1.25 & SAVE <4> LO-S 800 ~ 1500 & SAVE <5> HI-S 1000~3500 & SAVE <6> AL-T [H&L, L&L, H&H] & SAVE <7> AL-1 800 ~ 2500 & SAVE

<8> <1> AL-2 800 ~ 2500 & SAVE <9> D-Ti 0 ~ 99 & SAVE <10> OFFS -999 ~ 999 & SAVE <11> ADDr 1 ~ 99 & SAVE <12> <1> BAUD [4800bps ~ 57600bps] & SAVE <13> B-EA 1 ~ 19 & SAVE <14> B-ti <1> 0.01 ~ 3.00 & SAVE

<1> Measuring Mode - Display a measuring temperature by 4 DIGIT - Enter the setting mode when press 2 seconds <2> - Select 1-color or 2-color <3> Emission - Adjust emissivity of target <4> LO-SCALE - 4mA setting for FULL SCALE <5> HI-SCALE - 20mA setting for FULL SCALE - (ex) If you set HI-SCALE as 2000: 4mA Analogue Output ---------- Lo Display. 12mA Analogue Output ---------- 1400 Display. 20mA Analogue Output ---------- 1000 Display <6> AL-TYPE (ALARM-TYPE) - Three(3) types of alarm settings (H-L, L-L, H-H) - ALARM Relay can use two - ALARM-1,ALARM-2 6-1> H&L Setting ALARM-1: ALARM-1 (If more than set value, relay on ) ALARM-2: ALARM-2 (If less than set value, relay on ) 6-2> L-L Setting ALARM-1: ALARM-1(If less than set value, relay on) ALARM-2: Ignoring 6-3> H-H Setting ALARM-1: ALARM-1(If less than set value, relay on) ALARM-2: Ignoring <7> ALARM-1 - ALARM-1 Alarm relay output (Please refer to ALARM TYPE setting) <8> ALARM-2 - ALARM-2 Alarm relay output (Please refer to ALARM TYPE setting) <9> AL-TIME(ALARM TIME) - This menu is to prevent abrupt malfunction affected by shock or noise from outside. <10> OFFSET (Compensate measured value) - compensate the error of measured value which happened by sensor. ex) OFFSET: If you set -5: When the sensor output error is +5, display shows 0 after it compensates -5.

<11> ADDRESS - RS-485 <12> BAUDRATE - RS-485 <13> B-EA (sampling buffer number, use when measuring high temperature ) - user use it in the range of 1~19 - calculate average value as much as buffer number - ex) Temperature average = (500+502+504+506)/4=503 4 samples 500 502 504 506 <14> B_TIME ( Sampling delay time. Use when measuring high temperature) - user use it in the range of 0.00 ~ 3.00 sec ex) - 0.00 sec setting sampling of temperature value every 1 msec. - 0.01 sec setting sampling of temperature value every 10 msec. - 1.00 sec setting sampling of temperature value every 1000 msec 10. Communication specification and software Serial Interface((Initial value setting )) Baud Rate: 9600 baud Data bits: 8 Parity: none Stop bits: 1 *Please refer to software menu additionally.

11. Option Air-purge Air cooler

Up and down adjustable Bracket 485 To RS232 Converter Indicator (DI-20) 2 Inch Led Display

12. INSTALLATION Please make sure the target area is larger than the field of view. Best Good Incorrect SENSOR Target diameter Equal to view field Target diameter Larger than view field Target diameter Less than view field Background The spot size is decided by the distance from the sensor to the target. Please refer to the section 5. Optical field of view and make sure your target area is larger than the field of view. 13. Dimension

Bracket AL1