Contents Overview...1 Characteristics...1 Scope of application...2 Working principle... 2 Technical Parameters... 3 Power requirement... 4 About servi

Similar documents
Laser Particle Sensor Module PM2008M

Laser Particle Sensor Module PM2008M

Installation Instructions for the

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Laser Particle Sensor Module PM2009

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Rev Flame Detection Sensor. TF100 User Manual

HUM-M2 Humidity Sensor Module Description

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

Grove - Laser PM2.5 Sensor (HM3301)

SprintIR -W CO2 Sensor

The reprint reproduction or disclosure of this material to the third party is prohibited. PARTICULATE MATTER SENSOR. Introduction of

FIS SMART SENSOR U (Draft 1) June 25, 2001

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

ICC. Macurco Modbus Monitor Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Series Temperature Controller Instruction Sheet

Infrared Carbon Dioxide Sensor Module CM1107-Dual Beam

High-accuracy Multi-sensor IAQ Detector MSD Commercial grade for intelligent& green buildings

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

ECO N DATE DESCRIPTION OF CHANGE CHG

Smart GPS Antenna A1035-D

Multi-sensor System For Indoor Environment Monitoring Zheng-yu Wanga, and Xiao-ru Zhangb

FST DFS Notifier Onyx 640

ModBus DE-1 INSTALLATION AND USER MANUAL

Sintrol Snifter A1+ Manual. Version 1.2.2

/8 DIN Level Indicator

Series Digital Controller Instruction Sheet

Data Aire DAP TM III. Metasys Control Points

4590 Tank Side Monitor. Service Manual. WM550 Communication Protocol. Software Versionv2.03 SRM011FVAE0808

User manual. KNXgal. version

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

User manual. KNXpar. version

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

FlameGard 5 UV/IR HART

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

M15-GSL12P30 M15-GSL12P30S Heat Spy Infrared Thermometer User Manual

Technical data Humidity Temperatur General data Electrical data Two designs duct version (LK) wall mounting

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

GPON OLT Optical Transceiver SFP Module RTXM RTXM Features

USER MANUAL FOR OPERATING SYSTEM

Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14A)

RS485 MODBUS Module 8AI

FCX-11AB5-3XX-XX 155Mbps BIDI SFP TRANSCEIVER(100Km)

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Temperature Controllers

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

POWER METER INSTRUCTION MANUAL

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Use of the application program. Functional description. instabus EIB Application program description. October CO Touch-Manager wave

Be prepared for Sigfox RF & Protocol Tests

TSI Model 8630 PRESSURA Room Pressure Monitor Modbus Communications Application Note LC-106

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Product Specification

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

Instructions for the fan motor control system with integrated wiring terminals SILVER C

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

EPON ONU Optical Transceiver SFF Module

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

RSMFM-2R MULTIFUNCTIONAL

Sub psi SPECIFICATIONS

General Specifications

S3F8S28. Smoke Detector. Revision 0.00 February Samsung Electronics Co., Ltd. All rights reserved.

APPROVED by U.S. EPA As a Class III Equivalent Method Designation for the measurement of PM 2.5

IM 77J01H07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

MODEL P531, P532 AND P532UI FLAME MONITOR OPERATING MANUAL

Instruction Manual Model Backup Switch, 1 for 8

SprintIR -6S CO2 Sensor

FS Mircom FX2000 Fire Alarm Panel

Stratos Optical HD/SD BNC to "ST" Video Media Converter (Transmitter)

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Infrared Carbon Dioxide Sensor Module CM1106SL

GPS Evaluation Kit EVA1037/1080

POP_ Smoke Detector

FIS30XXseries Gas sensor module SPECIFICATIONS

Ethernet General Purpose

Turbimax CUE21 / CUE22

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Key Features. General Description

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

FIRERAY 5000 range USER GUIDE

SPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan

FieldServer Driver - Serial FS Notifier NCA

Wireless Smart Metering LAN-WMBUS-M. Wireless MBUS, door and window sensor. With optional glass break accessory.

Turbimax CUE21 / CUE22

LCF Touch Modbus Datasheet Application Security Advice Caution

POP_ Smoke Detector

2-wire Passive Intelligent Loop (LED) Display Meter

Transcription:

Laser PM2.5 Sensor specification Product model: SDS021 Version: V1.0 Nova Fitness Co.,Ltd 2015-10-14

Contents Overview...1 Characteristics...1 Scope of application...2 Working principle... 2 Technical Parameters... 3 Power requirement... 4 About service life...4 Product specifications... 5 1.Product size...5 2.Interface specification... 5 The UART communication protocol...5 Extended functionality... 6 Installation size... 7 Matters needing attention...8 Contact...9

Overview The SDS021 using principle of laser scattering,can get the particle concentration between 0.3 to 10μm in the air. It with digital output and built-in fan is stable and reliable.product has passed the CE, FCC and RoHS certification. Characteristics 1. Accurate and Reliable: laser detection, stable, good consistency; 2. Quick response: response time is less than 10 seconds when the scene changes; 3. Easy integration: UART output (or IO output can be customized), fan built-in; 4. High resolution: resolution of 0.3μg/m 3 ; 1

5.Certification:CE,FCC,RoHS; 6.Cutter: professional internal spiral duct, cutting the small particles effectively;make the measurement more accurate; 7.Flocculant prevention design:with inlet which can calculate the space of the fence specially,effectively prevent the catkin floc etc; 8.Clean hole:independent design,convenient maintenance; 9.Smallest:the minimum volume of laser PM2.5 sensor. Scope of application Detector of PM2.5;Purifier;Fresh air system and other detection field. Working principle Using laser scattering principle: Light scattering can be induced when particles go through the detecting area. The scattered light is transformed into electrical signals and these signals will be amplified and processed. The number and diameter of particles can be obtained by analysis because the signal waveform has certain relations with the particles diameter. 2

Technical Parameters No Item Parameter Note 1 Measurement parameters PM2.5,PM10 2 Range 0.0-999.9 μg /m 3 3 Rated voltage 5V 4 Rated current 60mA±10mA 5 Sleep current <4 ma Lase&Fan sleep 6 Temperature range Storage environment:-20 ~ +60 Work environment:-10 ~ +50 7 Humidity range Storage environment:max 90% Work environment:max 70% 8 Air pressure 86KPa~110KPa 9 Corresponding time 1s 10 Serial data output frequency 1Hz 11 Minimum resolution of particle <0.3 μm 12 Counting yield 70%@0.3μm 98%@0.5μm 3

13 Relative error Maximum of ± 15% and ± 10μg/m 3 25, 50%RH 14 Product size 42.5x32x24.5mm 15 Certification CE/FCC/RoHS Power requirement Power Voltage:4.7~5.3V Power supply:>1w Supply voltage ripple:<20mv About service life Service life is the key parameter of laser dust sensor. The laser diode in this sensor has high quality and its service life is up to 8000 hours. If you need real-time data (such as detector), you can use the default configuration that measures at the frequency of 1time per second. On the occasion of real-time demand is not high (such as filter, air quality monitoring, etc.), you can use the discontinuous working method to prolong the service life. For example, you can start the sensor for 30 seconds per minutes. If you have any other requirements, please contact us, we are willing to serve for manufacturers and developers. 4

Product specifications 1.Product size L*W*H=42.5*32*24.5mm 2.Interface specification No Name Comment 1 5V 5V Input 2 NC Not Connect 3 GND Ground 4 R RX of UART(TTL)@3.3V 5 T TX of UART(TTL)@3.3V The UART communication protocol Bit rate :9600 Data bit :8 Parity bit:no Stop bit :1 Data Packet frequency: 1Hz The number of bytes Name Content 0 Message header AA 1 Commander No. C0 2 DATA 1 PM2.5 Low byte 3 DATA 2 PM2.5 High byte 4 DATA 3 PM10 Low byte 5 DATA 4 PM10 High byte 6 DATA 5 ID byte 1 5

7 DATA 6 ID byte 2 8 Check-sum Check-sum 9 Message tail AB Check-sum: Check-sum=DATA1+DATA2+...+DATA6 PM2.5 value: PM2.5 (μg /m 3 ) = ((PM2.5 High byte *256) + PM2.5 low byte)/10 PM10 value: PM10 (μg /m 3 ) = ((PM10 high byte*256) + PM10 low byte)/10 Extended functionality 1.Manual hibernation(sleep and wake up) 2.Timed hibernate(cycle to work) 3.User ID setting 4.Set data reporting mode(active report and query report) 5.Version number query If you have any other requirements, please contact us. 6

Installation size 7

Matters needing attention 1 In the context of the sensor power supply; 2 Do not press the sensor fan site; 3 Note the process design to ensure smoothness and stability of sensor airflow; 4 Please ensure that the sensor to work under normal conditions of temperature and humidity; 5 Avoid severe vibration during transport, so as not to affect the accuracy of detection and accuracy; 6 Follow this specification is the correct sensor installation. 8

Contact Nova Fitness Co.,Ltd TEL :+86-0531-82868288 FAX:+86-0531-82868198 www.inovafitness.com 9