ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

Similar documents
US$ 350 for a single warranty claim

Thermostat KPU. Data sheet

34% A temperature sensor overview Cut back on system costs Upgrade to the right technology. cost reduction

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

DOO IK ENG PRODUCT CATALOG DOO IK ENG TEMPERATURE SENSOR PRESSURE SWITCH NON FLOW SWITCH THERMOMETER

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

SITRANS T temperature transmitters A broad product family for every application. sitrans

Pressure switch KPU. Data sheet

Fan Heaters Type VLEx

Model 144H. Product Data Sheet , Rev DB February Content

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

SENSOR PRESENTATION MISSION CRITICAL APPLICATIONS IN HARSH ENVIRONMENT

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

Model 144H. Product Data Sheet , Rev DB February Content

Gas cylinder scale Model GCS-1

Dräger Polytron 5100 EC Detection of toxic gases and vapors

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Increased safety and reducing energy consumption with the motion control RPI 01

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

SITRANS F M MAG 3100 P:

Inductive slot sensor

OPTIBAR DP 7060 Supplementary Instructions

DICTATOR Hold-Open Systems for Hazardous Areas

API Marine. Sensors Presentation. Mission critical applications in harsh environment. - API - Acoustic Precise Instruments -

Rosemount 3490 Series

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Rosemount 2090P Pulp and Paper Pressure Transmitter

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

80% leak risk reduction through fully hermetic coupling. Reduce lifecycle costs Increase savings and design freedom.

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Dew-Point Transmitters and Instruments

Annubar Flowmeter Series

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

MAKING MODERN LIVING POSSIBLE. Performer VSD. For Residential Applications - R410A. Quick reference

17 % better water hammer damping than industry standards. Protect your system Hammer your costs. ia.danfoss.com

Technical Data. General specifications. Rated operating distance s n 5 mm

VERSAFLOW VORTEX Supplementary instructions

80% leak risk reduction through fully hermetic coupling. Reduce lifecycle costs Increase savings and design freedom.

17 % better water hammer damping than industry standards. Protect your system Hammer your costs. ia.danfoss.com

PEPPERL+FUCHS GmbH

Dräger Polytron 5700 IR Detection of flammable gases and vapours

ProcessMaster, HygienicMaster FEX300, FEX500

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

Zero Superheat Control

Integrated Solutions Low Voltage Systems

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Building Services Brochure

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech

OPTIBAR P 1010/2010 C Supplementary instructions

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Intrinsically Safe Solutions

Recalibrate the way you look at gas detection

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Capacity controller EKC 331T REFRIGERATION AND AIR CONDITIONING. Manual

DGS - Danfoss Gas Sensor Check / Calibration Procedure

Worcester Controls PS/PM Series UltraSwitch. Switchbox

Temperature controller for steam (PN 25) AVT / VGS - external thread

Manual Power relay SR853

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Absolute and Gage Pressure Transmitter

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

MAKING MODERN LIVING POSSIBLE. Wiring Diagram. DHP-iQ.

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Temperature controller for limitation for the discharge gas temperature EKC 319A REFRIGERATION AND AIR CONDITIONING. Manual

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

PWM expansion valves 2028

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Operating Instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Sanitary Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

Flameproof Manual Call Points Series MCP

Rosemount 4500 Hygienic Pressure Transmitter

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

/8 DIN Level Indicator

Dräger PIR 7200 Toxic Gas Detection Transmitter

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

ALTAIR 5X Multigas Detector Product Specification

Installation Guide. BasicPlus 2 WT-DR & WT-PR Room Thermostats

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Emerson Superheat Control. The smart solution for your application

ATEX Explained A brief Introduction

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Rosemount 2088 Absolute and Gage Pressure Transmitter

Transcription:

Brochure Controls Tough controls for tough environments Danfoss controls - designed and approved for hazardous areas ATEX approved program ia.danfoss.com

Danfoss controls tailored for use in hazardous areas In Ex areas, where people s lives and high-value materials are at stake, safety, robustness and reliability requirements leave no room for compromise. By working in partnership with Danfoss Industrial Automation, you can be confident that you will get precisely the controls needed to achieve optimum safety. Our comprehensive range of intrinsically safe solenoid valves, switches, pressure transmitters and temperature sensors is designed and approved to be used in environments where there is a danger of explosion. Our products cover countless applications within the heating, marine & engine, hydraulic and vacuum industries. 2

A partner you can trust With more than 70 years of experience, Danfoss Industrial Automation has acquired unparalleled knowledge of technologies and applications. This experience has given us a leadership position within our key technologies of pressure sensors and controls, temperature sensors and controls, fluid controls and motor starters. Thanks to the scope of our product range, we can often deliver what might be termed special configurations directly from stock, saving you time and money. Where necessary, we can modify products to your specifications or, where the specifications do not yet exist, we ll help you define them. Serving a broad, global market within diverse and demanding industries, Industrial Automation is your one-stop partner for industrial control components and systems. Through Danfoss Industrial Automation, you gain access to the entire Danfoss pool of technology. 3

Solenoid valves Danfoss solenoid valves are designed for explosion-risk environments; i.e., where flammable liquids and gasses are produced, transported or tapped. They are delivered as a part programme, with a separate valve and coil, and can be quickly and simply assembled without tools, providing optimum product flexibility and availability. Approval Approved for use in Zone 1 in accordance with directive Atex 2014/34/EU Coils for Solenoid valves ATEX 2014/34/EU Ex mb IIC T4 Gb ITS 09 ATEX 16835X Compatibility for Valve type Power consumption holding Coil type Supply voltage Volt Code No. EV210B 1,5-2,5 EV310B 1,5-3,5 EV220B 6-100 EV250B 6-22 EV251B 10-22 EV222B 15-50 EV224B 15-32 EV227B 6-22 10W 21 VA BO024C 24V50/60 Hz 018Z6595 BO110C 110V50/60 Hz 018Z6593 BO230C 230V50/60 Hz 018Z6592 BO240C 240V50/60Hz 018Z6591 10W BO024D 24 DC 018Z6596 + = (see data sheets for further details) Coils for Solenoid valves ATEX 2014/34/EU Ex mb IIC T4 Gb DEMCO 14 ATEX 1314X IECEx ULD 14.0001X Compatibility for Valve type Power consumption holding Coil type Supply voltage Volt Code No. EV220B 6-10NC EV220B 12-22NC EV220B 6-10NO EV220B 15-50NC EV250B EV224B EV227B 8,6W BZ120C 110V 50Hz 9,0W BZ120C 120V 60 Hz 9,5W BZ240C 230V 50 Hz 9,0W BZ240C 230V 60Hz 018F4703 018F4704 + = (see data sheets for further details, reduced MOPD) 4

Switches The Danfoss RT-E series, pressure, differential pressure and temperature switches, are designated for industrial refrigeration and general industrial application in explosive zones. The range includes solutions for refrigeration systems with ammonia, hydrocarbons and other applications where flammable gases, vapours, mists are likely to occur. RT-E pressure and temperature switches for use in explosive zones incorporate an SPDT changeover switch, where contact position depends on the pressure or temperature values of the system. Approval Approved in accordance with 2014/34/EU ATEX directive, explosive zone 1, for surface equipment, category 2. Pressure Switches (as standard connection G3/8A and with auto reset) Type Range Differential Max. working pressure Code no. RT 112E 0.1 to 1.1 bar 0.07 to 0.16 bar 7 bar 017-518566 RT 113E 0 to 0.3 bar 0.01 to 0.05 bar 0.4 bar 017-519566 RT 1AE -0.8 to 5 bar 0.5 to 1.6 bar 22 bar 017-500966* RT 116E 1 to 10 bar 0.3 to 1.3 bar 22 bar 017-520166 RT 5E 4 to 17 bar 1.2 to 4 bar 22 bar 017-525266 RT 6AEW 5 to 25 bar fixed 3 bar 34 bar 017-513866* RT 6 AEB Man. reset 10 to 28 bar fixed 1.5 bar 34 bar 017-513466* RT 6AES Man. reset 10 to 28 bar fixed 1.5 bar 34 bar 017-522166* RT 117E 10 to 30 bar 1 to 4 bar 42 bar 017-529866 * with welded nipple Ø6.5/10 mm Differential Pressure Switches (as standard connection G3/8A and with welded nipple Ø6.5/10 mm) Type Range Differential Max. working pressure Code no: RT 260AE 0.5 to 4 bar fixed 0.3 bar 22 bar 017D003666 RT 262AE 0.1 to 1.5 bar fixed 0.1 bar 11 bar 017D003066 Temperature Switches (as standard with 2 m capillary tube) Type Range Type of charge Max. sensor temp. Code no: RT 9E -45 to -15 C A 150 C 017-617866* RT 14E -5-30 C B 150 C 017-509866 RT 14E -5-30 C B 150 C 017-617966* RT 101E 25-90 C B 300 C 017-512666 RT 101E 25-90 C B 300 C 017-618066* RT 107E 70-150 C C 215 C 017-515366 RT 107E 70-150 C C 215 C 017-618266* RT 123E 150-250 C C 300 C 017-521666 RT 123E 150-250 C C 300 C 017-618366* Type of charge: A= Vapour, B = Adsorption, C = Partial * 5m capillary tube 5

Pressure Transmitters Our Eex pressure transmitter programme offers reliable pressure measurement, even in harsh and demanding applications. It covers a 4-20 ma output signal, absolute and gauge (relative) versions, measuring ranges from 0-1 to 0-600 bar, and zero point and span adjustment with a wide range of pressure connections. Some models are also available with integrated pulse snubber for protection against cavitation, liquid hammer or pressure peaks. Approval EEx ia IIC T6 explosion protected in accordance with ATEX 100a. Pressure Transmitters (as standard with span/zero adjustment, connection G1/2A, 4-20 ma output signal and with Pg9 electrical plug) Type Measuring range Pe (bar) Comments Code no. MBS4701 0-1 bar 060G4303 MBS4701 0-1.6 bar 060G4300 MBS4701 0-2.5 bar 060G4304 MBS4701 0-4 bar 060G4305 MBS4701 0-6 bar 060G4306 MBS4701 0-10 bar 060G4307 MBS4701 0-16 bar 060G4301 MBS4701 0-25 bar 060G4308 MBS4701 0-40 bar 060G4309 MBS4701 0-60 bar 060G4302 MBS4701 0-100 bar 060G6326 MBS4751 0-160 bar with pulse-snubber 060G4311 MBS4751 0-250 bar with pulse-snubber 060G4312 MBS4751 0-400 bar with pulse-snubber 060G4313 MBS4751 0-600 bar with pulse-snubber 060G4314 6

Temperature sensors and transmitters Danfoss temperature sensors are designed for heavy-duty applications and are based upon decades of global experience within the marine industry and in refrigeration plants - among the toughest environments. The range includes different versions with measuring ranges from -50 C to 800 C. MBT 5113 and MBT 5116 for measuring and regulating exhaust gas in stationary and marine equipment like diesel engines, turbines and compressors, among others. MBT 5250 and MBT 5252 for measuring and regulating temperature in piping systems and refrigeration plant on ships or at all points where reliable, robust and accurate equipment is required. These temperature sensors include Pt-sensing elements which are passive components and therefore classified as a simple apparatus. As such they cannot be approved according to the ATEX directive. Temperature transmitter MBT 9110, EEx approval: KEMA 03ATEX1339 X II 1 G D, T80 C T105 C EEx ia IIC T6 / T4 Max. amb. temperature for T1...T4 85 C Max. amb. temperature for T5 and T6 60 C ATEX, applicable in zone 0, 1, 2, 20, 21 or 22 The EEx approved transmitter can be used together with our temperature sensors if certain measures are taken. Approval Included in the Danfoss programme is the temperature transmitter, MBT 9110, which is a terminal block version in accordance with the ATEX directive. Ex installation For safe installation of MBT 9110 transmitters in hazardous areas, the following points must be observed: The module must only be installed by qualified personnel who are familiar with national and international laws, directives and standards that apply. The transmitter is approved to be mounted in a metal enclosure Form B according to DIN 43729 that is providing a degree of ingress protection of at least IP 6X in accordance with EN 60529. The ATEX transmitter can be mounted in the standard B-head or in a heightened lid, but only the transmitter is ATEX approved and marked according to this. 7

Danfoss Ex products where people s lives and high-value materials are at stake, safety, robustness and reliability requirements leave no room for compromize Solenoid valves Temperature sensors and transmitters Pressure Transmitter Switches Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. IC.PB.DIC.J3.02 Copyright Danfoss Produced by DCS (ck) 2017.04