OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-10 AseptiMini Pneumatic Portable Dental System

Similar documents
OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-20B CompriCart

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-17A Express Air Portable Dental System

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-17X2 Express Plus II Portable Dental System

OPERATION AND MAINTENANCE MANUAL

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AEU-425 Transport II Portable Dental System

Installation Operation Maintenance Troubleshooting Version Dec/17. Mobile Cabinets

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AMC-20CF Mobile Dental System

Use and Care Guide. Over the Patient Units and Swing Mount Units

Operating Manual for Profident / Profident PLUS

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215]

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AEU-525 Transport III Portable Dental System

Procenter Delivery Systems. [Includes: Delivery Units and Assistant s Units (All Styles)] (no serial numbers on Assistant s Units)

Artizan Ortho-Pedo Bench Installation / User Manual

A-dec 300 Support Systems

INSTRUCTIONS FOR OPERATION AND CARE OF

Unlimited Mobility. The Mobile Dental Units From. B-Productions

18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler.

Important Safeguards. Save these instructions for future reference. (continued on next page)

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

USER S OPERATING AND INSTRUCTION MANUAL

OPERATING INSTRUCTIONS

Troubleshooting the MPH 24FP Series Pedestal Hydrant

48 MaxxAir Portable Evaporative Cooler Owner s Manual

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

X99 Series. Dental Handpiece. Instruction For Use

K-COMPACT Use & Care Guide. Get the most from your new Keurig brewer

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

OPERATING INSTRUCTIONS

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

ENCLOSED UNIT TECHNICAL MANUAL Items # &

Garment Steamer Model SC620

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

USER MANUAL. Bottled Water Dispenser SAVE FOR FUTURE USE. Model #

FOOD WARMING/MERCHANDISING CABINET MODEL

MODEL 7000 SUCTION UNIT

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

K-SELECT Use & Care Guide. Get the most from your new Keurig brewer

WA A Aqua Sub Bottom-load Water Cooler

STORM. Bottom-Load. Water Dispenser User Manual

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

Operator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes

SELF-CONTAINED POWER MISTER

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

Installation & Operating Instructions

INSTRUCTIONS FOR OPERATION AND CARE OF

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Electric Digital Kettle

HW-17 Record Cleaning Machine Setup and Instruction Manual

INSTALLATION and OPERATION INSTRUCTIONS

OPERATING INSTRUCTIONS. Hearing Instrument Restoration System.

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER

30-pint Dehumidifier User Guide

Dental Unit User's Guide

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

PumpLab TM Operator s Manual

Instructions for Use. Technical and General 2 Ablion Pl. London W6 0QT, United Kingdom Rev. A. European Representative

INSTRUCTIONS FOR OPERATION AND CARE OF

OPERATION MANUAL. LED Coupling OM-TR355E. Please read this operation manual carefully and file for future reference.

Glendale 52 in Ceiling Fan Owner's Manual. Glendale Ventilador de Techo de 1.32 m Manual del Propietario

Use & Care Guide. Get the most from your new Keurig brewer

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE

STERI-VAC CENTRAL SUCTION SYSTEM

Table of Contents. English

SACKSAFOAM QUICK FILL OPERATIONS MANUAL 2019A

Lifetime Limited Warranty

EL400 OPERATION MANUAL

UNDERCOUNTER DISHWASHER

Cat 5 Pro Vacuum OPERATOR S MANUAL

User Manual J0841X. Piezo Electric Ultrasonic Scaler / Polisher Combo Unit. Jorgensen Laboratories, Inc.

Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model)

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

30 Misting/Oscillating Fan Model Number 01030

Beer Keg Dispenser User s Manual

Model ST243. Instructions for Use & Warranty Information

EXCELSIOR ENGLER HIGH SPEED VETERINARY DENTAL AIR UNIT INSTRUCTION MANUAL

IMPORTANT SAFETY INFORMATION:

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900

Installation & Operating Instructions

USER MANUAL SAVE THESE INSTRUCTIONS

Downloaded from 5KSS1121

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC016 - AC018. Water Claw 4282 South 590 West Salt Lake City, UT FAX

Couverture B80 oneway seb.qxd:couverture B80 oneway seb.qxd. USA: CANADA :

PowerVac G Single to Twin Conversion Kit [ ]

OPERATING INSTRUCTIONS

Wax Base Heater & Dispenser

MODEL NO RUSSELL HOBBS APOLLO 1.8L DIGITAL FILTER COFFEE MAKER

Bag-In-A-Box Oil System Instruction Manual Model #2257EX & 2257DX For Export Bag-In-Box Pumps Made After March 2003

User Manual / Installation Instructions

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

Installation & Operation Manual

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

Transcription:

OPERATION and MAINTENANCE INSTRUCTION MANUAL ADU-10 AseptiMini Pneumatic Portable Dental System

TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Setting Up the Unit...................2 Operation Functions..................4 Operation...........................6 Sterilization & Maintenance.............7 Troubleshooting......................9 Warranty...................Back Cover SPECIFICATIONS: Size: 11.75 x 14.75 x 13.75 (30 cm x 37 cm x 35 cm) Weight: 24 lbs (11 kg) Power Source: Air Connection P.O. Box 1548 Woodinville, WA 98072 8333 216 th Street S.E. Woodinville, WA 98072 International (425) 487-3157 Toll Free(800) 426-5913 www.aseptico.com info@aseptico.com 0459 Aseptico Inc 98072 USA EC REP Advena Ltd HR4 9DQ U.K. To prevent injury to people and damage to property, please heed relevant warnings and remarks. They are marked as follows: WARNING: CAUTION: NOTE: Serious injury or death may result if ignored. Damage to property or the environment may result if ignored. Important additional information and hints.

Your new Aseptico ADU-10 AseptiMini delivery system is one of the finest portable pneumatic units available to the dental profession. The ADU-10 is designed for field or operatory use. The system features a three-way air/water syringe, automatic highspeed and lowspeed handpiece controls, and an optional high volume vacuum and saliva ejector vacuum. A pressurized water tank supplies water for handpiece coolant and syringe. The AseptiMini is powered by a single connection to compressed air via the air supply line. Congratulations This system is engineered to provide many years of reliable service. Please read the instructions provided in this manual to receive the best and longest service from your Aseptico equipment. Separate manuals may be provided to cover the operation and maintenance of handpieces or other accessories for your unit. PACKAGE CONTENTS ADU-10 System Case/Control Box Highspeed and Lowspeed Handpiece Controls TA-90D 3-Way Air/Water Syringe with Tips NWS-8 Water Reservoir Accessory Tray Wet/Dry Foot Control AA-21 High Volume Vacuum (Purchased separately) AA-25 Low Volume Vacuum (Purchased separately) 1

SETTING UP THE UNIT (Refer to Fig. 1) 1. Place the ADU-10 AseptiMini in an upright position (the carrying handle at the top) on a flat, stable surface. 2. Unlatch and open the case. 3. Remove all protective packing materials such as foam, clear plastic wrap and gray corrugated cover on the foot control toggle switch. 4. Check to make sure the syringe, highspeed and lowspeed handpieces are hanging in their proper holder. 5. Place the foot control on the floor. 6. Remove the white plastic water supply tank and the high volume vacuum system (optional) from behind the storage strap and install on proper quick disconnect, just above each bottle. 7. To install, pull back snap ring, push bottle into quick coupler, and release. 8. Hang the vacuum hoses (optional) in their holders on the holder bar. Figure 1 AA-25 SALIVA EJECTOR SYSTEM AA-21 HIGH VOLUME VACUUM SYSTEM SYRINGE & HANDPIECE CONTROLS WATER SUPPLY TANK AIR SUPPLY LINE FOOT CONTROL 2

OPERATION TA-90D 3-WAY AIR/WATER SYRINGE: Depress the right button for air operation, and the left button for water operation. Depressing both buttons will create a mist. The syringe features quick-change autoclavable tips: To remove a tip, press on the locking collar surrounding the tip socket and pull the used tip straight out of the socket (Fig. 2). To insert a new tip, press locking collar and push tip into socket as far as it will go. Release collar and gently tug on tip before using to ensure that tip is securely locked into socket. Syringe Tip Sterilization: 1) Remove contaminated syringe tip. 2) Remove all visible signs of contamination before autoclaving. 3) Autoclave tip at 132 C (270 F) for ten minutes. 4) Sterilize between each patient use. NOTE: Since only the tips can be autoclaved, it is recommended that the air/water syringe be bagged with a disposable, single-use plastic sleeve between each patient use. Figure 2 - Tip Removal & Installation DEPRESS LOCKING COLLAR NOTE Avoid damage to the syringe by removing the tip when closing the ADU-10 case for transportation. 3

HANDPIECE CONTROLS: The Aseptico ADU-10 includes one highspeed control with water coolant and one lowspeed control mounted to a swivel holder bar (Fig. 3). These are fully automatic. By placing a handpiece into its proper holder, the pressure is automatically shut off. When a handpiece is removed from it's holder, pressure is automatically opened and ready for use with the foot control. Figure 3 3-WAY AIR/WATER SYRINGE HIGHSPEED CONTROL LOWSPEED CONTROL WET/DRY FOOT CONTROL: The foot control provides variable speed operation to the handpieces and activates water coolant spray to the highspeed handpiece control (Fig. 4). Remove the foot control from its storage compartment in the case and position it on the floor. For handpiece operation, apply foot pressure to any part of the center disk. The handpiece must be removed from its holder before operation can begin. To activate the water coolant to the highspeed handpiece control, move the wet/dry toggle switch to the right position. Move the toggle switch to the left position to disable water coolant. Figure 4 OFF Water Coolant Toggle ON AIR SUPPLY LINE: To activate the ADU-10 unit, you must connect the air supply line to a dry, filtered, 70-100 psi air source such as the Aseptico AA-74 compressor. Simply remove the 1/4" grey air supply line from the storage compartment in the ADU-10 case and connect the quick disconnect into the compressed air source (Fig. 5). Figure 5 4

WATER SUPPLY TANK: The Aseptico ADU-10 incorporates a self contained pressurized water system. This consists of a 28oz. white plastic tank dispensing water through the 3-way syringe and highspeed handpiece control. The water tank screws in to the ADU-10 case (Fig. 6). Before removing the tank for refilling, it must be depressurized. Disconnect the tank from the air supply allowing pressure to release. To fill the tank, release pressure, then unscrew tank and fill with water. Screw tank back into place. Sterilization of tank is recommended between uses. PRESSURE GAUGE: The pressure gauge on the front panel gives you a visual indication of the drive air pressure to handpieces (Fig. 7). WATER COOLANT FLOW CONTROL: Adjusts the flow of water coolant to the highspeed handpiece control (Fig. 7). AIR COOLANT ON/OFF TOGGLE: Stops the flow of air coolant to the highspeed handpiece control (Fig. 7). Figure 6 CAUTION Water Supply Tank is pressurized during operation. Depressurize water bottle by loosening 1/2 turn before removing. Figure 7 PRESSURE GAUGE PRESSURE 1 2 HANDPIECE ADJUST WATER AIR FLUSH VACUUM + WATER COOLANT FLOW CONTROL AIR COOLANT TOGGLE FLUSH TOGGLE AA-25 SALIVA EJECTOR ON/OFF HANDPIECE DRIVE AIR ADJUSTMENTS 5

FLUSH TOGGLE: The flush toggle allows you to quickly and completely flush your handpieces, washing away contaminants which may have accumulated in the handpiece and tubing. You should flush the handpieces for about 5 seconds after every patient, and about 20 seconds at the beginning of each day to reduce overnight bacterial accumulation which may have occurred. To flush your handpieces remove them from their holder, directing the spray away from you and into a basin, then flip the flush toggle (Fig. 7) and hold the desired number of seconds. Release the flush the flush toggle. OPTIONAL AA-21 HIGH VOLUME VACUUM SYSTEM: The AA-21 Steri-Vac is an air powered, self contained oral evacuator system. It is supplied with a plastic waste container and a single high velocity hose (Fig. 8). Remove the vacuum bottle and hose assembly from behind the storage strap and install into the quick disconnect above it. To operate, remove the vacuum hose from holder and insert a standard oral evacuator tip. Depress the on/off switch on the side of the hose end for vacuum. Waste from the vacuum system will collect in the attached plastic bottle. When the waste container is 3/4 full, it should be emptied. After each use, the vacuum system should be cleaned by running clean water or a vacuum system cleanser through the evacuator hose and thoroughly cleaning waste bottle. A small and large capacity waste container are provided and are interchangeable. Figure 8 QUICK-DISCONNECT VACUUM ON/OFF WASTE CONTAINER 6

OPTIONAL AA-25 SALIVA EJECTOR VACUUM SYSTEM: The AA-25 Saliva Ejector is an air powered, self contained oral evacuation system. It is supplied with a plastic waste container and a single low velocity hose (Fig. 9). To operate, remove the saliva ejector valve from holder and insert a standard saliva ejector tip. Turn the vacuum toggle switch on. The vacuum may be adjusted by moving lever valve on the saliva ejector tip. The lever valve assembly snaps apart at the swivel and may be autoclaved. Waste from the vacuum system will collect in the attached plastic bottle. When the waste container is 3/4 full, it must be emptied to prevent a back-up in the system. After each use, the vacuum system should be cleaned by running clean water or vacuum system cleanser through the evacuator hose and thoroughly cleaning the waste bottle. Also, remove rubber tip and clean or replace the plastic screen. Figure 9 SALIVA EJECTOR VALVE W/LEVER WASTE CONTAINER 7

ADJUSTMENTS HANDPIECE DRIVE AIR ADJUSTMENT: The handpiece drive air pressure must be adjusted to meet the handpiece manufacturer's specifications. For most highspeed handpieces, the maximum drive pressure is 32 PSI, and 45 PSI for most lowspeed handpieces. Locate the drive pressure adjustment controls labeled '1' and '2' on the front panel (Fig. 7). Control '1' adjusts the highspeed handpiece control, and control '2' adjusts the lowspeed handpiece. Install and run a highspeed or lowspeed handpiece. While watching the pressure gauge, turn the handpiece drive air pressure control with a small screwdriver until the handpiece runs at the specified maximum pressure when the foot control is fully depressed. Clockwise decreases pressure and counterclockwise increases pressure. WATER COOLANT FLOW ADJUSTMENT: The water coolant to the highspeed handpiece control can be varied from a fine fog spray to a heavy stream. Install and run a highspeed handpiece at a midrange speed. Make sure the wet/dry toggle is in the 'on' position on the foot control. Turn the water coolant flow control located on the front panel clockwise until it seats softly. Begin turning counterclockwise until a fine mist is visible. This will provide excellent cooling while bur is cutting. MASTER PRESSURE REGULATOR VALVES: These adjustment valves are preset for normal operating pressures and should not require any further adjustment. These valves are located on the left panel of the delivery head as you face the unit. If for some reason they need further adjustment, you can adjust as follows: MASTER AIR LINE PRESSURE VALVE: The regulator valve toward the back of the delivery head controls the line pressure from the compressed air source to the unit. Turning the valve stem clockwise will increase this pressure and counterclockwise will decrease pressure. MASTER WATER PRESSURE VALVE: The regulator valve toward the front of the delivery head controls the air input pressure in the water tank. Turning the valve stem clockwise will increase water pressure and counter-clockwise will decrease pressure. Do not over-pressurize the water tank. 8

MAINTENANCE Because of its simple design, the Aseptico ADU-10 AseptiMini requires very little maintenance. Any maintenance that is needed can be performed in minutes. BLEEDING THE SYSTEM: If the unit will not be used for an extended period of time or the unit might be subjected to freezing conditions, you should bleed the system. Simply empty the contents of the water supply tank and install the tank back onto the quick disconnect. Operate the air/water syringe and highspeed handpiece with water coolant 'on' until only air comes through the water lines. Pack unit and store as normal. HANDPIECE FLUSH: Flush the handpieces for about 5 seconds after every patient, and about 20 seconds at the beginning of each day. Refer to page 4. GENERAL CLEANING: The external surfaces of the case should be cleaned using a mild solution of liquid detergent and water. Any external surfaces of the unit that are contacted during use should carefully be wiped down with a disinfectant at the beginning of each day and between each patient. As described in the vacuum section the optional high and low volume vacuum systems should always be thoroughly cleaned after use. PACKING THE UNIT FOR TRANSPORTATION: If the ADU-10 unit is going to be shipped abroad, it is recommended that the original or similar packing material be put into place to avoid dents and scratches from parts inside of the case shifting. 9

WARRANTY Aseptico warrants these products against defects in material or workmanship for a period of one (1) year, from date of original invoice. Some handpieces are warranted for one year under the same conditions. Other handpieces and expendable components, such as air turbines and light bulbs, are covered by shorter warranty periods, or have no warranty. Aseptico's sole obligation under product warranty is (at its sole option and discretion) to repair or replace any defective component or product in part or whole. Aseptico shall be the sole arbiter of such action. In the event of alleged defect under warranty, the purchaser is to notify Aseptico's Customer Service Department promptly. Customer Service will provide instructions, usually directing that the product be returned for service. Shipment to Aseptico and the cost thereof is always the responsibility of the purchaser. Accidental misuse, inappropriate installation, or failure to perform directed maintenance voids the warranty. Aseptico does not assume, under this warranty, any risks or liabilities arising from the clinical use of its products, whether or not such use involves coincidental utilization of products manufactured by others. NOTE: In the interest of serving our customers more efficiently, customers receiving service on nonwarranted repairs are expected to accept charges that are less than $250.00 without further notification. P/N: 420197 Rev. C ECO 12075 04/2009 P.O. Box 1548 Woodinville, WA 98072 8333 216 th Street S.E. Woodinville, WA 98072 (425) 487-3157 (800) 426-5913 www.aseptico.com info@aseptico.com PRINTED IN THE USA