Type MTS Miniature Test Switches

Similar documents
Testing Accessories. Test PaddleS. Test Paddle Attachment Plugs Insulated Socket Wrench Jumper Strips Test Lead Kit

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

Battery Interconnects

PART GENERAL 1.01 SECTION INCLUDES

PANELBOARDS & BUILDING DISTRIBUTION

KUFO/SECO DUST COLLECTOR

SECTION AUTOMATIC TRANSFER SWITCHES

Revisions to this application specification include: Updated document to corporate requirements Changed product types in table in Figure 6

SECTION (16140) - WIRING DEVICES

Reliability in Laboratory Centrifuges Since Operator s Manual. Models 614B, 614L, 614U/UL and 614V/VL Laboratory Centrifuge. Rev. 5.

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

CONVERSION KIT INSTRUCTIONS Commercial Electric Water heaters

SECTION AUTOMATIC TRANSFER SWITCHES

Hex-Key Wrenches. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation

Description. Construction

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

KUH. Horizontal Unit Heater. Applications. Description

Standard Duct Heaters Open Coil

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

Installation Instructions

Installation Instructions

Electric Space Heater

Custom Duct Heaters. Special Applications

Engineered Solutions SYSTEMS CUSTOM ENGINEERED TO YOUR SPECIFICATIONS. Fused Coordination Panelboards...ES 2. Fusible Shunt Trip Switch..

Custom Duct Heaters. Special Applications

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

Operation Manual. ParaBeam 400/200 Series. ParaBeam 400 Center Mount. ParaBeam 400 Pole-Op

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description

CADDY CORPORATION. Utility Distribution Systems

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

SECTION ISOLATED POWER SYSTEMS

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

2408/2900. Fire Guard

Quick response concealed horizontal sidewall sprinkler VK481

Tamper & Weather Resistant Receptacles

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

2 PREPARE THE OPENING

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Q7800H Integrated Burner Control Subpanel

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

Page 1 of 7. Form No. F_ Rev Replaces Form No. F_ Rev 17.1 (added 205deg version)

Ilnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER

mirage standard response concealed pendent sprinkler vk492 (K5.6)

Installation Instructions

Commercial and Light Industrial Fire Alarm Control Panel

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

2409/2900. Fire Guard

Installation Instructions

FREEDOM RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK480 TECHNICAL DATA

Installation Instructions

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

TECHNICAL DATA. Page 1 of 6

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

Specification Grade Straight Blade Receptacles. Quality solutions that provide reliable connectivity in all applications

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

SINGLE DUCT TERMINAL UNITS

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

quick response horizontal sidewall sprinkler vk360 (K8.0)

EEMAX ProAdvantage Series 1

ELITE SERIES Downflow - High Efficiency Blower Motor

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Light Duty Commercial Electric Voltage and Wattage Conversion Instructions

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

Rugged Telephones GAI-TRONICS. A Hubbell Company

Academy Owner s Manual

SECTION (15900) - INSTRUMENTATION AND CONTROL FOR HVAC

SAFETY PRODUCTS CATALOG

Greentrol Automation, Inc.

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

NT DUAL CHANNEL DISPLAY. User Guide

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

freedom residential concealed pendent sprinkler vk474 (K5.8)

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

MERIT Series R-410A - Upflow / Horizontal

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

IMPORTANT SAFETY INFORMATION:

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

SUPPORT EQUIPMENT MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE

Standard Spray concealed horizontal sidewall sprinkler VK481

freedom residential concealed pendent sprinkler VK488 (K3.0)

Service Handbook. Servicing should only be performed by a Qualified Service Agent.

Transcription:

Type MTS Miniature Test Switches Compact and versatile Front- and back-connected styles Safe, durable, rugged and reliable Recognized by CUL & UL Class IE qualified per IEEE Standard 33-1974 DESCRIPTION In many panelboard, switchgear, metering, control circuit and instrumentation applications, space is at a premium. Yet provisions must be made to facilitate troubleshooting, testing, calibration and checkout of relays, meters, transducers, instruments and control systems. STATES Type MTS Miniature Test Switches are the compact, versatile solution for disconnecting and testing these devices and circuits. They are the result of over 60 years of experience in the design and manufacture of test switches, and make use of the latest improvements in material composition and construction techniques. Many features are incorporated for increased safety, durability, ruggedness and reliability. All the features you need, including potential elements, current elements and make-before-break short-circuiting elements for current transformer circuits and test jacks, are available in test switches ranging from 1 to 5 poles on one base, and in a miniature size. Each switch blade can be operated independently or, where required, adjacent handles can be ganged for simultaneous operation. All Type MTS Test Switches are available in both front- and back-connected styles. Protective covers are automatically included with all back-connected styles and may be ordered as an optional item with front-connected switches. CLASS 1E QUALIFIED PER IEEE STANDARD 33-1974 Type MTS Test Switches have successfully completed a generic test program that meets the requirements of most nuclear power plants for Class 1E applications outside containment. Extensive accelerated-life testing was conducted by an outside, independent firm using thermal aging, mechanical aging, environmental extremes, radiation exposure and seismic simulation to conduct tests. The service conditions and parameters of the test program included: 41-year life at 131 F (55 C), 600 operations, 95% humidity,. x 108 rads of radiation and 10g maximum accel- eration seismic level. Recognized by UL and CUL Underwriters Laboratories Inc. recognizes STATES Type MTS Miniature Test Switches under its component program, File No. E75355, with a rating of 600 volts, 30 amperes. Space-saving miniaturization means full test capability; yet, a Type MTS 10-pole switch requires just 7 inches of mounting space. Unit-pole construction permits virtually any pole arrangement from 1 to 5 poles mounted on a single base. STATES TYPE MTS TEST SWITCHES 1

FEATURES AND BENEFITS " Self-extinguishing materials: All non-metallic components are made of self-extinguishing, flame-retardant materials with Underwriters Laboratories best rating for selfextinguishing materials (V-O). " Nonferrous material: All current-carrying metallic components, including hardware, are made of highest quality nonferrous materials such as copper, bronze, brass or phosphor bronze. This ensures excellent conductivity and minimizes galvanic action between dissimilar metals. " Nickel plating: All current-carrying metallic components, including hardware, have a corrosion-resistant nickel finish that ensures good electrical contact and smooth operation of moving parts even after years of inactivity. " Safety-grip handle: A molded handle covers the terminal and includes a lower lip that projects over the metal parts of the switch, thus protecting the operator from contact with live components. " One-piece jaw and hinge: One-piece construction of hinge and jaw eliminates unnecessary, multiple connection points. " Special blade shape: All blades are shaped so that the edge of the blade enters at a right angle to the jaw; thus, the blade enters and exits the full width of the jaw simultaneously. " Switch jaws: All STATES Test Switches have uniform contact pressure over the full width of the blade. The ping heard when opening the blade is due to the special, spring-grade phosphor bronze used in the jaw. This design ensures an excellent low-resistant contact that will not overheat. " High barriers: Maximum circuit isolation is obtained by extra-high barriers that provide uncompromised protection. Barriers are permanently mounted and cannot fall out or be knocked out, as in some snap-in designs. " Short-circuit jaw: A rugged, make-before-break element is used to short the secondary of a current transformer. " Fixed terminal studs: The screw terminals on which wiring connections are made are a part of a rigid, immovable assembly and cannot be turned or backed out. " Test jack: The test jack eliminates the possibility of opening current transformer secondaries and permits safe, easy measurements to be made in current circuits without disturbing permanent wiring. A dual-circuit test plug, such as the STATES Cat. No. 15000, inserted into the test jack puts the measuring instrument in series with the current circuit. The test jack does not carry current except when making a test because it is shunted by a standard switch blade that is opened only when the test jack is used. " Color-coded handles: Unless otherwise specified, potential elements have red handles and current elements have black; however, the following other colors are available at additional cost: blue, orange, white, yellow, green. " Identification card holder: Each safety grip handle is slotted for insertion of an identification card for marking or coding. Cards are available under Cat. No. MTS8. Safety-grip handle Pole-ganging available Identification card holder Special angled blade Extra-high, permanent barriers Fixed terminal studs Self-extinguishing flame-retardant insulating material One-piece jaw and hinge 5 8 inch centers compatible with Type NT Terminal Blocks STATES Type MTS Test Switch STATES TYPE MTS TEST SWITCHES

All configurations are available in either a front- or back-connected style. FRONT-CONNECTED SWITCHES The front-connected test switch usually is used where wiring entering and leaving the test switch is located on the same side of the panel that the test switch is mounted. To order front-connected switches, refer to Ordering Information. Front-connected type BACK-CONNECTED SWITCHES All switches can be provided in a back-connected version so that the switch is mounted on one side of a panel and the wiring connections are made on the opposite side. Back-connected switches have factory-installed insulated barriers that project from the rear of the switch. They include either clear or opaque covers. To order back-connected switches, refer to Ordering Information. Back-connected types STATES TYPE MTS TEST SWITCHES 3

COVERS STATES Type MTS Test Switches feature rugged, virtually unbreakable covers available in clear or opaque styles. These covers are manufactured from tough, self-extinguishing, flame-retardant polycarbonate. The covers are constructed so that all switch blades must be closed when the cover is properly sealed. Switches provided with covers include two insulated studs that have holes for wire seals. To add a cover, refer to Ordering Information. COVERS FOR FRONT-CONNECTED SWITCHES Covers for front-connected switches are open or slotted at the bottom of each side to permit wiring to enter and exit between the cover and the panel. COVERS FOR BACK-CONNECTED SWITCHES A cover is automatically included with a back-connected test switch. However, you must select either a clear or opaque style. Slotted, front-connected clear cover Nonslotted, back-connected clear cover The nonslotted covers for back-connected switches fit flush with the panel because all wiring exits at the rear of the test switch. Front-connected opaque (C1) cover Back-connected opaque (C) cover Front-connected clear (C3) cover Back-connected clear (C4) cover 4 STATES TYPE MTS TEST SWITCHES

TYPICAL INSTALLATIONS FOR STATES TYPE MTS TEST SWITCHES 1 1φ Watt Transducer 4-Pole Test Switch - Cat. No. 04-N D.C. OUTPUT (4 POLE) 3φ Watthour Meter 7-Pole Test Switch - Cat. No. 07-K 1 3 (7 POLE) 1 3 Overcurrent Relays 10-Pole Test Switch - Cat. No. 10-E 13N 51-1 51-51-3 V M A M V M A M V M A M (10 POLE) 1 3 N STATES TYPE MTS TEST SWITCHES 5

The catalog numbers under the arrangements on the following pages are for front-connected switches without covers. These same numbers are also used as the basis for ordering back-connected. The catalog numbers are three digits followed by a letter or letter and number combination. Example: 03-A 1/1/1 03-A The slashes / in the arrangements represent barriers that are installed standard between any adjoining elements of opposite polarity. To order front-connected switches Specify the catalog numbers shown under the arrangements on the following pages. Example: 10-A For covers, add the appropriate prefix: Cover Prefix Front-connected, slotted, opaque C1 Front-connected, slotted, clear C3 Example: C3-10-A To order back-connected switches Specify the desired arrangement and add the suffix -B. Example: 10-A-B All back-connected switches are provided with either a clear or opaque cover. For covers, add the appropriate prefix: Cover Prefix Back-connected, solid, opaque C Back-connected, solid, clear C4 Example: C4-10-A-B Special Orders Special Arrangements: In addition to the typical arrangements shown on the following pages, special arrangements are available. These can be made of any combination of potential or current elements, with a maximum of 5 poles. For more information, refer to the following example and illustrations on Page 38. ORDERING INFORMATION To specify non-standard colors, add to the element number the appropriate color code: Color Color Code Color Color Code Black k Red r Blue b White w Green g Yellow y Orange e To order a switch with handles in non-standard colors, you must specify the arrangement with colors indicated. For example, to order a 10-pole switch with special handle colors, specify: Arrangement: 10/10r/10g/10w/1k/1k Ganged handles: You may specify a yoking bar to gang adjacent handles. For example, to order a switch with the adjacent potentials ganged, you must specify: Gang all potentials Hinge position: The U in an arrangement indicates the hinge is positioned upside down from the typical arrangement. OPTIONAL ACCESSORIES Socket Wrench and Insert To speed installation of the terminal nuts on STATES Test Switches, the socket wrench (Cat. No. 1608) and 3 8 inch insert (Cat. No. 1607) are available. Also available are the 5 16 inch insert (Cat. No. 1605) for use in installing the terminal nuts on STATES Type Terminal Blocks and STATES Type MTS Test Switches. The screwdriver attachment (Cat. No. 160) makes this wrench your complete meter installation tool. Dual Circuit Plug By inserting the STATES Dual Circuit Plug (Cat. No. 15000) into the test jack, safe measurement can be made of current transformer secondary current. To order a customized, 10-pole, back-connected switch with a clear, back-connected cover, specify: Switch Type: STATES Type MTS No. of poles: 10-pole test switch Arrangement: 10//11/1/16 Style: Back-connected Cover: Clear, back-connected Handle Colors: The standard colors for handles are red for potential and black for current. Handles are also available in other colors. Jumper Strips Cat. No. TBT167 Pole Strap Cat. No. TBT168 58 Pole Strap (The TBT168 can be cut to the required length) This nickel-plated jumper strip is made specially for the STATES Type NT & ZWM Terminal Blocks and the STATES Type MTS Test Switches. 6 STATES TYPE MTS TEST SWITCHES

FRONT VIEW 1-POLE 1 Other -Pole Standard Arrangement: 6-4 0-G 4-POLE 1/1/1/1 4-POLE (CONT.) 1/1/13 3-POLE 01-A Color Options: 1k 01-C 1y 01-D 1/1/1 03-A 04-A / 04-B 1/13/1 9 16 04-D Color Option: k/k 04-A 04-L 13/1/1 01-B 03-D 1/1/1/1 -POLE 1/1 1/10 04-E 04-M 13/13 0-A Color Options: 0-B k 0-J 10 0-C 11 0-F Color Option: 1k/1k 0-H 1y/1y 0-D 11r 0-L 03-B 10/1 03-C 13/1 03-H 1/13 03-J 17 03-E Other 3-Pole 6-6-5 03-K 1/1/10 04-F 1/1/11 04-J 10/1/1 04-K 10/ 04-G 1/10/1 04-N 04-H 0-4 04-C Other 4-Pole 1/10/4 04-A3 1/16 04-A5 9/9/9/9 04-R 9/4-14 04-S 11/11 04-W 11b/11e 04-Z 0-9 04-A4 0r-4 04-U 4-19r 04-T 13 6-6-4 03-L 11/10 0-E 9/9/9 03-F 9/4-5 03-G 04-Q Color Key: k: Black b: Blue g: Green e: Orange r: Red w: White y: Yellow STATES TYPE MTS TEST SWITCHES 7

FRONT VIEW 6-POLE 6-Pole (CONT.) 7-Pole (CONT.) 5-POLE 1/1/1/1/1/1 1/1/13/13 1/10/1/10/1 1/1/1/1/1 06-A 06-S 07-K 05-A // 13/13/13 1/10/1/11/1 1/1/16 05-H 1/1/1/10 06-D 16/16 06-E 06-B Other 6-Pole 1/1/1/1/11 06-P //13 06-L 07-B 1/1/1/10/10 07-C 05-B 1/1/10/1 1/1/1/10/1 7-POLE 1/1/1/1/1/1/1 Color Option: 1k/1k/1k/10/10 07-P 06-F 1/1/1/10/11 05-C 1/10/1/1 1/10/10/1 07-A 1/10/1/1/1/1 07-E 06-G 1/13/1/13/1 05-D 10/1/10 1/1/10/10 07-G 1/1/10/1/1/1 07-D 06-J 13/13/13/9 05-F 11/1/10 11/11/11 07-F 1/1/1/1/10/1 07-L 05-G 9/9/9/9/4 05-J 1/1/1/13 06-K 10/10/10 06-C 1/13/13/1 07-H 16/10/10 07-J Other 7-Pole #1/1/1/1/1/1/1# 07-M 1/1/1/1/11/11 07-Q 1/6-1-6-9-9/1 07-N 6-6-6-6-6-6-4 07-S 9/9/9/4-19 07-R 06-H 05-E Color Key: k: Black b: Blue g: Green e: Orange r: Red w: White y: Yellow 8 STATES TYPE MTS TEST SWITCHES

FRONT VIEW 8-Pole (CONT.) 9-POLE 10-POLE 8-POLE 1/1/1/1/1/1/13 1/1/1/1/1/1/1/1/1 1/1/1/1/1/1/1/1/1/1 1/1/1/1/1/1/1/1 08-C 09-A 10-A 08-D 1/13/1/1/13/1 16/16/16 1/1/1/1/1/1/1/10/1 1/1/1/10/1/1/1 08-H 09-B 10-B 08-E 1/1/1/1/13/13 1/1/1/10/10/10 1/1/1/1/1/10/10/1 1/10/1/1/11/1 08-J 09-U 10-C 08-A 16/4/13/13 16/10/10/10 1/1/1/10/1/1/10/1 10/10/1/1/1/1 08-F 09-E 10-D 08-B 1/13/13/13/1 1/10/1/10/1/10 1/10/1/1/1/1/10/1 1/1/1/1/10/10 08-M 09-K 10-F 08-G 13/13/13/1/1 1/13/1/13/1/13 1/10/1/10/1/10/1 1/10/10/10/1 08-N 09-H 10-E 08-K 13/13/13/13 1/1/1/13/13/13 1/1/1/1/10/10/10 10/10/10/1/1 08-W 09-D 10-H 08-L 10/10/10/10 08-P 1/1/1/13/1/1/1 08-Q Other 8-Pole #1/1/1/1/1/1/1/1# 08-T 1/6-1-6-9-1-9/1 08-R /// 08-S 6-6-6-6-6-6-6-6-4 09-C Other 9-Pole 1/1/4/10/10/10 09-F 9/9/9/9/9/9/9/9/1 09-G 11/9/11/9/11/9 09-J 1/1/1/10/10/10/1 10-J 1/10/10/10/10/1 10-K 10/10/10/10/1/1 Color Key: k: Black b: Blue g: Green e: Orange r: Red w: White y: Yellow 10-L STATES TYPE MTS TEST SWITCHES 9

FRONT VIEW 10-Pole (CONT.) 10/10/10/10/10 10-M 1/13/1/13/1/13/1 10-G 13/13/13/13/13 10-N 13/13/13/1/1/1/4 10-P Other 10-Pole 1/1/1/4/10/10/10 10-T 1/1/1/4/13/13/13 10-AA 1/10/1/10/1/10/4 10-R //// 10-Y 9/9/9/9/9/9/9/9/9/9 10-Q 9/9/9/9/4-5-5-5-5-5 10-V 9/9/9/4#-19-19# 10-U 10/10/10/1/1/1/1 10-W 13/13/13/13/13 10-X 1/1/1/1/9-5-9-5-9-5 10-S 11-POLE 1/1/1/1/1/1/1/1/1/1/1 11-A 10/10/9/10/9/9/ 11-C 13/13/1/1/1/1/1/1/1 11-B 1-POLE 1/1/1/1/1/1/1/1/1/1/1/1 1-A ///// 1-B 1/1/1/1/1/1/1/1/1/1/1/1 1-C 10/10/10/10/10/10 1-D Other 1-Pole 1/1/10/1/10/1/10/1/1 1-F 1/10/1/10/1/10/1/10 1-E 9/9/9/9/9/9/9/9/9/16 1-H 13/13/13/13/13/13 1-G 16-POLE 16 - #1 elements 16-A 8 - # elements 16-B Other 16-Pole 1/1/1/1/13/13/1/1/1/1/1/1/1/1 16-D 1/1/1/4/10/10/10/10/10/10 16-C 1-POLE 1 - #1 elements 1-A 13/13/13/4/13/13/13/4/13/13/13/4 1-B 4/13w/13g/13k/4/13w/13g/13k/4/ 13w/13g/13k 1-C 13k/13g/13w/4/13k/13g/13w/4/13 k/13g/13w/4 1-D -POLE - #1 elements -A ////////// -B 4-POLE 4 - #1 elements 4-A 1 - # elements 4-B 1 - #13 elements 4-E 6-POLE 6 - #1 elements 6-A 6 - #1k elements 6-K 40-POLE 40 - #1 elements 40-A 0 - #13 elements 40-B 5-POLE 5 - #1 elements 5-A 6 - #13 elements 5-B Color Key: k: Black b: Blue g: Green e: Orange r: Red w: White y: Yellow 10 STATES TYPE MTS TEST SWITCHES

ELEMENTS FOR CUSTOMIZED SWITCHES NOT LISTED UNDER TYPICAL ARRANGEMENTS 1 16 Single-Pole Potential Ganged Double-Pole Potential Ganged Three-Pole Potential 13 17 9 Ganged Two-Pole Short-Circuiting Current Assembly Ganged Three-Pole Short-Circuiting Current Assembly Current Test Jack 6 10 0 Short-Circuiting Assembly With Right-Hand Common Bar Right-Hand Current Assembly Consists of Test Jack and Short-Circuiting Current Assemblies Ganged Three-Pole Short-Circuiting Current Assembly, Right Extension 5 11 19 Short-Circuiting Assembly With Left-Hand Common Bar Left-Hand Current Assembly Consists of Test Jack and Short-Circuiting Current Assemblies Ganged Three-Pole Short-Circuiting Current Assembly, Left Extension 90 91 4 Right-Hand Short-Circuiting Assembly Ending at a Terminal 5 Left-Hand Short-Circuiting Assembly Ending at a Terminal 5A 6 Through Bar 600-Volt 50-Volt Fuse Holder NOTES: 1. Barriers are provided between poles of opposite polarity.. Potential handles are red and current handles are black unless otherwise specified. 3. Specify adjacent handles to be ganged (yoked) if desired. 4. Arrange elements left to right, front view. Blank Space Color Key: k: Black b: Blue g: Green e: Orange r: Red w: White y: Yellow STATES TYPE MTS TEST SWITCHES 11

3.475 in. Dimensions (in inches) NUMBER OF POLES 1 3 4 5 6 7 8 9 10 11 1 13 14 15 16 17 18 19 0 1 3 4 5 6 A B C D 1 3/8 5/8 3 1/4 3 7/8 4 1/ 5 1/8 5 3/4 6 3/8 7 7 5/8 8 1/4 8 7/8 9 1/ 10 1/8 10 3/4 11 3/8 1 1 5/8 13 1/4 13 7/8 14 1/ 15 1/8 15 3/4 16 3/8 17 5/8 1 1/8 1 3/4 7/3 3 3 5/8 4 1/4 4 7/8 5 1/ 6 1/8 6 3/4 7 3/8 8 8 5/8 9 1/4 9 7/8 10 1/ 11 1/8 11 3/4 1 3/8 13 13 5/8 14 1/4 14 7/8 15 1/ 16 1/8 17 3/8 9/16 1 3/16 1 13/16 7/16 3 1/16 3 11/16 4 5/16 4 15/16 5 9/16 6 3/16 6 13/16 7 7/16 8 1/16 8 11/16 9 5/16 9 15/16 10 9/16 11 3/16 11 13/16 1 7/16 13 1/16 13 11/16 14 5/16 14 15/16 15 9/16 16 13/16 1 13/16 1/ 3 1/8 3 3/4 4 3/8 5 5 5/8 6 1/4 6 7/8 7 1/ 8 1/8 8 3/4 9 3/8 10 10 5/8 11 1/4 11 7/8 1 1/ 13 1/8 13 3/4 14 3/8 15 15 5/8 16 1/4 16 7/8 18 1/8 E 43/64 1 19/64 1 59/64 35/64 3 11/64 3 51/64 4 7/64 5 3/64 5 43/64 6 19/64 6 59/64 7 35/64 8 11/64 8 51/64 9 7/64 10 3/64 10 43/64 11 19/64 11 59/64 1 35/64 13 11/64 13 51/64 14 7/64 15 3/64 15 43/64 NUMBER OF POLES 7 8 9 30 31 3 33 34 35 36 37 38 39 40 41 4 43 44 45 46 47 48 49 50 51 5 A B C D 18 1/4 18 7/8 19 1/ 0 1/8 0 3/4 1 3/8 5/8 3 1/4 3 7/8 4 1/ 5 1/8 5 3/4 6 3/8 7 7 5/8 8 1/4 8 7/8 9 1/ 30 1/8 30 3/4 31 3/8 3 3 5/8 33 7/8 34 1/ Note: To provide extra mounting support, at 6 poles one blank space is added; at 51 poles two blank spaces are added. Panel cutout mounting not recommended 18 18 5/8 19 1/4 19 7/8 0 1/ 1 1/8 1 3/4 3/8 3 3 5/8 4 1/4 4 7/8 5 1/ 6 1/8 6 3/4 7 3/8 8 8 5/8 9 1/4 9 7/8 30 1/ 31 1/8 31 3/4 3 3/8 33 5/8 34 1/4 17 7/16 18 1/16 18 11/16 19 5/16 19 15/16 0 9/16 1 3/16 1 13/16 7/16 3 1/16 3 11/16 4 5/16 4 15/16 5 9/16 6 3/16 6 13/16 7 7/16 8 1/16 8 11/16 9 5/16 9 15/16 30 9/16 31 3/16 31 13/16 33 1/16 33 11/16 18 3/4 19 3/8 0 0 5/8 1 1/4 1 7/8 1/ 3 1/8 3 3/4 4 3/8 5 5 5/8 6 1/4 6 7/8 7 1/ 8 1/8 8 3/4 9 3/8 30 30 5/8 31 1/4 31 7/8 3 1/ 33 1/8 33 3/4 34 3/8 E STATES Type MTS Front-Connected Switches STATES Type MTS Back-Connected Switches 3 in. 1/ 4 in 119/ 3 in 33 / 64 in BACK-CONNECTED BARRIER OUTLINE 9/ 16 in 5/ 3 in 3 3/ 64 in COVER OUTLINE 11/16 11/16 B RECOMMENDED PANEL CUTOUT FOR BACK-CONNECTED E 0.7 in. OVERALL LENGTH 3 / 8 in COVER D OVERALL LENGTH STANDARD ON BACK- CONNECTED SWITCH Color Key: k: Black b: Blue g: Green e: Orange r: Red w: White y: Yellow 1 STATES TYPE MTS TEST SWITCHES

471 BRONZE WAY DALLAS TX 7537-1019 USA Ph: 1 800 35 4574 Toll Free: 1 14 331 7316 Fax: 1 14 331 7368 Email: states@megger.com Web: www.statesproducts.com MTS_DS_en_V0