SAT- 3 Installation Setup Guide

Similar documents
SAT-3 Room Temperature Controller

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

Safety & Installation Instructions

ONX908MTW-0/24V MULTI STAGE THERMOSTAT

Please read this manual carefully before installation and use.

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Instruction Guide: Thermostat Operation

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

ETN-24-SUPER-SF Series

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

Installation Instructions

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

Model: Available in: Sapphire Black and Glacier White. 1 Series

ETN-24-SUPER-PROG (US Program - Celsius)

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

GreenCon On/Off Room Thermostat

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Touch Screen Room Thermostat with Modbus Communication

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

ETN-24-HC21-PROG Econo-Vent

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Installation Manual for Hot Yoga Studio Electric Radiant Heating

Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01.

Model: Touch-RS. 1 Touch-RS

Model: Edge-HC. 1 edge-hc

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

TB8220U Commercial Programmable Thermostat OWNER S GUIDE

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

EL-TSTAT-8820 Safety & Installation Instructions

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

GreenCon On/Off Room Thermostat

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

Model: Available in : Sapphire Black and Glacier White. 1 Series

User s Manual

SC Installation, Operation & Application Guide

Model: Touch-RF. 1 Wireless Series

USER'S OPERATING INSTRUCTIONS

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

Installation Instructions

Programmable Thermostat

Model: PRT-TS / PRT-NTS

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

User Manual THR870CUK Programmable Thermostat

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

SMART 2000 Digital Programmable Thermostat Installation Manual Robertshaw 2/

Model: Slimline-N. 1 Slimline Series

OWNER S MANUAL Venstar Inc. 08/07

Underfloor Heating Programmable Thermostat

T-32-TS Touchscreen Thermostat. Installation Manual

SC Installation, Operation & Application Guide

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

User Guide for EHE & EHE Programmable Room Thermostat

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

USER S INFORMATION MANUAL

1F Non-Programmable 5/1/1 Day 7 Day

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

Operating Instructions Model : HC HC-N

INSTALLATION & USER MANUAL

OWNER S MANUAL Venstar Inc. 08/07

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

ELECTRONIC COMMUNICATING THERMOSTAT

User Manual THR872CUK Wireless Programmable Thermostat

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

HEAT PUMP PROGRAMMABLE THERMOSTAT

USER S MANUAL. Wired Remote Controller MWR-WS00. System Air Conditioner ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA RUSSIAN

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

Sapphire Series TSVW & TWWS Chillwater Digital Thermostats

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

OWNER S MANUAL Venstar Inc. 08/07

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS

Installation Instructions

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

Safety & Installation Instructions

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

Programmable Digital Thermostat

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis

AMANA PHWT-A200 THERMOSTAT

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Elegance. SMT-700 User manual. Ver

HEAT COOL. Meets Commercial California Title 24

For Quick Set-Up go to Page 14

Safety & Installation Instructions

7-Day. Digital Thermostat. residential. & 2-cool

Installer Guide. WARNING Important Safety Information. 1 Specifications

HEAT HEAT HEAT COOL COOL

Transcription:

SAT- 3 Installation Setup Guide Date: 4 February 2016 Issue: 2 Applies to: SAT- 3 room temperature controller, part number 201-000- 146

Contents 1. Quick Start Guide...2 1.1. General... 2 1.1.1. Installation Settings... 2 1.1.2. Clock Setting... 2 1.2. Fan Setup... 2 1.3. Air- Conditioner Commissioning... 2 2. Detailed SAT- 3 Configuration...3 2.1. Installation Settings... 3 2.2. Fan Settings... 5 2.3. Commissioning Mode... 6 2.4. Return Air Sensor Option... 6 3. SAT- 3 Fault Indications 8 Page 1 of 7

1. Quick Start Guide 1.1. General Refer to the User s operating instruction booklet for everyday operation of the SAT- 3. The system may include only one SAT- 3. In the following instructions, to navigate the settings of the SAT- 3 thermostat press or. To adjust a setting press or. 1.1.1. Installation Settings Apply power to the system. The SAT- 3 is configured by default to operate with standard Temperzone air- conditioners and in most cases no adjustment is necessary. If required, refer to section 2.1 on page 3 for details of the installation settings and how they may be adjusted. 1.1.2. Clock Setting Hold down the or key for 3 seconds to start adjusting the clock. The clock symbol will start to flash as well as the presently selected day of the week. Set the day of the week and time using the keys detailed in section 1.1. When the day and time are set correctly, leave the SAT- 3 for 15 seconds to return to normal operation. 1.2. Fan Setup Activate fan setup by holding down and together for 3 seconds. When fan setup is active the symbol on the display flashes on and off. 1. Adjust the low fan to a suitable low level while monitoring the airflow. 2. Adjust the high fan to a suitable high level while monitoring the airflow. When adjustment is complete press to exit fan setup. Setting Display Range Notes Low level fan SET Lo 2.0 to 8.0 Default 5.0 Steps of 0.333 e.g. 2.0, 2.3, 2.7, 3.0, etc. High level fan SET Hi 4.0 to 10.0 Default 8.0 Steps of 0.333 e.g. 4.0, 4.3, 4.7, 5.0, etc. 1.3. Air-Conditioner Commissioning Activate commissioning by holding down and together for 3 seconds. Test the cooling cycle and (if installed) heating cycle operation of the air- conditioner. Refer to section 2.3 on page 6 for full details of Commissioning. Page 2 of 7

2. Detailed SAT-3 Configuration 2.1. Installation Settings To activate installer hold down and together for 3 seconds. When the unit is in installer the symbol i will be shown. To confirm and save the new setting(s) press operation and the new settings will apply.. The thermostat will return to normal To cancel changes to the settings at any time press. Any changes made will be discarded and the thermostat will return to normal operation using the old settings. Setting Display Range Notes Minimum setpoint i SET Ct 5.0 C to Ht Steps of 0.5 C temperature Maximum setpoint i SET Ht Ct to 50.0 C Steps of 0.5 C temperature Temperature i td 0.5 to 1.5 C Steps of 0.5 C differential Indoor fan type i Ft 1 or 3 Single- or three- speed fan Default 3- speed Enable/disable Heating i On or off Default on Enable/disable Cooling i On or off Default on Enable/disable i On or off Default on (see note 1) Cool/Heat (auto) Enable/disable Fan i On or off Default on Only Enable/disable Dry i On or off Default off (see note 2) Enable/disable Quiet i On or off Default on Enable/disable Sleep i On or off Default on Enable/disable i On or off Default on Economy 12 or 24 hour clock i tc 12 or 24 hours Default 24 hours Number of stages i St 1 or 2 Default 1 Room temperature sensor Zone 1 temperature i rt 1, 2, 3 or 4 Default 1 (internal, see note 3) i OF - 4.0 to +4.0 C Steps of 0.1 C, default 0 (see note 4) Page 3 of 7

Zone 2 temperature Zone 3 temperature Zone 4 temperature Zone 5 temperature Zone 6 temperature Enable/disable zone control Maximum difference of zone setpoint from zone 1 set point Minimum number of zones that must be on i ZONE En On or off Default off. Must be off to function correctly without zone control board. i ZONE SP 2.0 to 10.0 C N/A see note 6 i ZONE nn 0, 1 or 2 N/A see note 6 Zone 1 Size i 1 to 5 N/A see note 6 Zone 2 Size i 0 to 5 N/A see note 6 Zone 3 Size i 0 to 5 N/A see note 6 Zone 4 Size i 0 to 5 N/A see note 6 Zone 5 Size i 0 to 5 N/A see note 6 Zone 6 Size i 0 to 5 N/A see note 6 Programmable timer function Set display backlight duration Set display backlight intensity Set modbus device address i tf 1 or 2 Default 1 (standard, see note 5) i bd 0 to 59 s Default 30s I bl 0 to 10 Default 10 i Ad 1 to 99 Default 8 Other settings will not function correctly. Set RS485 baud rate i br 1 to 4 1:4800 2: 9600 3:14400 Default 4: 19200 Zone controlled auto dead band i Ab 0 to 10.0 C N/A see note 6 Page 4 of 7

Notes: 1. Auto cool/heat can only be enabled if both cooling and heating are also enabled. 2. Dry (de- humidification) can only be enabled if cooling is also enabled. 3. Room temperature sensor: 1 = internal, 2 = external, 3 = average of internal and external, 4=zone 1 temperature (from modbus do not use with un- zoned systems). 4. Zone 1 temperature calibration is applied to the room temperature from the selected source described above in note 3. 5. Programmable timer function: 1 = standard, 2 = advanced. 6. Not applicable to systems without zone controller. 2.2. Fan Settings To activate fan setup hold down and together for 3 seconds. When Fan Setup Mode is active the symbol on the display flashes on and off. Settings in Fan Setup Mode are as follows: Setting Display Range Notes Low level fan SET Lo 2.0 to 8.0 Default 5.0 High level fan SET Hi 4.0 to 10.0 Default 8.0 Additional zone SET Ad 0 to 950 voltage increase Default 300 Zone 1 balance bl 10 to 100% Zone 2 balance bl 10 to 100% Zone 3 balance bl 10 to 100% Zone 4 balance bl 10 to 100% Zone 5 balance bl 10 to 100% Zone 6 balance bl 10 to 100% Steps of 0.333 e.g. 2.0, 2.3, 2.7, 3.0, etc. Not applicable to systems without zone controller As the settings are adjusted the unit controller adjusts its operation to allow the settings to be evaluated: Setting Unit controller operation Low level High level The indoor fan operates at the low voltage level selected The indoor fan operates at the high voltage level selected Page 5 of 7

If the key is pressed or if no key is pressed for 15 minutes the SAT- 3 will return to normal operation using the updated settings. If the button is pressed the SAT- 3 will discard the updated settings and resume normal operation with the previous settings. 2.3. Commissioning Mode To activate or de- activate commissioning hold down and together for 3 seconds. When commissioning is active the symbol i on the display flashes on and off. Commissioning automatically ends after 30 minutes and the thermostat returns to normal operation. Commissioning also can be terminated by again pressing and together for 3 seconds or by removing and then re- applying power to the thermostat. Operation in commissioning is identical to that in normal except that safety timer durations are made shorter as follows: Delay Normal Commissioning Minimum compressor on- time 90 seconds 10 seconds Minimum compressor off time 90 seconds 20 seconds Minimum time from compressor- on to next 6 minutes 30 seconds compressor- on Minimum cooling- to- heating change- over time 10 minutes 1 minute Minimum heating- to- cooling change- over time 10 minutes 1 minute Power on delay prior to starting compressor 2 minutes 2 minutes 2.4. Return Air Sensor option To use a return air sensor with the SAT- 3 the return air sensor must be connected to the SAT- 3. The SAT- 3 provides a socket that accepts a 2 pin JST connector of the standard type that Temperzone uses for its optional temperature sensors. The SAT- 3 must be configured to use the return air sensor. This is done with the Commissioning settings - see section 2.3 above. The options for selecting the controlling sensor are: 1 = internal, 2 = external, 3 = average of internal and external, 4=zone 1 temperature (from modbus do not use with un- zoned systems). In this case the "external" option refers to the return air sensor plugged in to the SAT- 3. Note: Return air sensing picks up on the air temperature in the return air duct. When the fan is off this may not be a good indication of the room temperature. For this reason we recommend using fan on with return air sensing. Fresh air introduced up- stream of the return air sensor will affect the temperature reading making it less representative of the room temperature. Take care with the sensor placement so that the temperature is not influenced by a fresh air intake better to be placed prior to any any fresh air introduction. Page 6 of 7

3. SAT-3 Fault Indications The SAT- 3 indicates some faults that may be useful during installation. Faults are indicated in the bottom right area of the display. Wiring changes should only be made with the power disconnected. Code Description Remedy displayed t1 SAT- 3 internal temperature sensor error The internal temperature sensor of the SAT- 3 is damaged. Replace the SAT- 3. t2 SAT- 3 external temperature Check the external temperature sensor t3 sensor error No communications between SAT- 3 and unit controller connected to the Sat- 3. Check the wiring between the unit controller and the SAT- 3. Check the SAT- 3 baud rate is set at 19200 baud (see section 2.1). Page 7 of 7