Landis & Gyr RAV 91 Operating Instructions

Similar documents
Operating Instructions

Operating Instructions

Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482

REA22 Room Temperature Controller

Model: Slimline-RF. 1 Slimline Series

Model: Slimline-B. Battery Series

Model: Touch-RF. 1 Wireless Series

Drayton Digistat +3RF

Model: PRT-TS / PRT-NTS

Self-learning Room Temperature Controller

Operating Instructions Model : HC HC-N

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

Designer TT Programme Set Up

Operating your heating system with the Prefect PRE5701 Programable Thermostat

: PRT / PRT PRT / PRT-N1

Vokèra OpenTherm 711 without external sensor connected

Underfloor Heating Programmable Thermostat

Vokèra OpenTherm 711 with external sensor connected

Model: Edge-HC. 1 edge-hc

Self-learning Room Temperature Controller

PRT-TS WiFi PRT-TS WiFi

Self-learning Room Temperature Controller

Model: Touch-RS. 1 Touch-RS

Model : PRT-EN Model: PRT-EN1

ECL Comfort 210 / 296 / 310

Owner s Manual. 5+2 Day Programmable Digital Thermostat

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

Model: Slimline-N. 1 Slimline Series

Self-learning Room Temperature Controller

CS027 User Instructions

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

Remote Controller. <Open the front cover> <ARC452A4>

Battery Powered Electronic Room Thermostat Cat. No. TRT033

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

Owner s Manual. Part Number 33CS250-01

Operating Instructions

Elegance. SMT-700 User manual. Ver

Operating Instructions Model: PRT/HW - PRT/HW-N Version 3. 09/09 Revision 2 Ref: PRT/HW/NV3

Programmable 5-2 Day Digital Thermostat

Cat No. 099A. Digital Programmable Thermostat for Weekday/Weekend Setting. User Maunal

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Battery Powered Electronic Programmable Room Thermostat

5+2 DAY PROGRAMMABLE DIGITAL THERMOSTAT

Customer Information Visually Impaired Programmable Talking Thermostat VIP 1007 Single Stage VIP Stage & Heat Pump VIP Stage Heat /Cool

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

OWNER S MANUAL. Part Number P

Room thermostat with 24-hour time switch and large LCD

3 Channel Multi-Purpose Programmer User Instructions

MAKING MODERN LIVING POSSIBLE. FP975 7-Day Electronic Programmer. User Guide. Danfoss Heating

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

Room Unit. Building Technologies SYNERGYR

CT2800 Programmable Thermostat

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

WLM2 WLTA WLTD WLTP WLCT2

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

Installation Instructions

Omnistat Architectual Specifications

Mynute. Standard efficiency system boiler 12e - 16e - 20e. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

C-Stat 17-ZW User Instructions

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Why Vaillant? Because there s smart and then there s vsmart. Vaillant vsmart. The USER Guide

Model: RT510RF. Installation Manual

Easy-Stat. Wireless Programmable Room Thermostat Pt No

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

ENGLISH REMOTE CONTROL MANUAL

Slimline Curve Electric Radiator. Step by Step Programming Guide

Model: Available in : Sapphire Black and Glacier White. 1 Series

DUO PLUS. Instruction manual

danfoss Heating Solutions 5

Self-learning Room Temperature Controller

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

TC-PHP01-A, TC-PAC01-A Comfort Series Programmable Thermostat. Owner s Manual

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

REMOTE CONTROL MANUAL

Programmable Load Management Thermostat

Room Units and Sensors for Use in Heating Plants. Siemens Building Technologies HVAC Products SIGMAGYR. Type summary

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

WARNING Important Safety Information

ES3247B. 3 Channel Programmer. User and Installation Instructions

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

Programmable Touchscreen Thermostats. Read all instructions before proceeding. Store this manual for future reference

RF Programmable Room Thermostat User Instructions

Owner s Manual. Digital Thermostat

Transcription:

Landis & Gyr RAV 91 Operating Instructions Siemens Building Technologies/HVAC Products RAV91 1/6

Operation, Settings, Readings 1) Setting wheel for time switch When setting the time switch, note items (2) and (3) (wheel can be turned in both directions). 2) 24-Hour Scale Showing the 24-hour day. This scale is used to select the heating program by means of the setting sliders (6a) (6b) (7a) (7b). 3) Time indicator Indicating the time of day (e.g. 7.00 h or 19.00 h) 4) Normal room temperature Here you set the room temperature you require when you are at home. Recommendation: 19 21 C. 5) Reduced room temperature Here you set the room temperature you require at night or when you leave the house for a few hours or for the weekend. Guide value: 10 15 C. 6a) Start of the normal heating program in the morning The time to be set here should be about ½ - 1 hour prior to the time you usually get up. This is the time when normal heating starts (red). 6b) End of the normal heating program in the evening The time to be set here should be about ½ - 1 hour prior to the time you usually go to bed. This is the time when reduced heating starts (blue). Siemens Building Technologies/HVAC Products RAV91 2/6

Overriding of the normal heating program in the evening 7a) Start of override function The time to be set here should be about ½ hour prior to the time you go to work. This is the time when reduced heating starts (blue). 7b) End of override function The time to be set here should be about 1 hour prior to the time you usually get home from work. This is the time when normal heating starts (red). 8) Overriding of the normal heating program: YES or NO Selection of the automatic overriding function 8a) Blue section pulled out Normal heating program is overridden (for weekdays). 8b) Blue section pushed back Normal heating program is not overridden (for Saturdays, Sundays, or holidays) 9) Selection of the heating program The heating program is selected here according to the symbols. 9a) Position (clock) means: Operation of the heating system according to the automatic time switch program set with the sliders (6a) (6b) (7a) and (7b). - From red to blue on normal room temperature. - From blue to red on reduced room temperature. 9b) Position (sun) means: This position provides continuous normal room temperature (4). The automatic heating program according to the time switch is inoperative. 9c) Position (moon) means: This position provides continuous reduced room temperature (5). The automatic heating program according to the time switch is inoperative. Siemens Building Technologies/HVAC Products RAV91 3/6

9d) Position (readiness) means: This position provides no heating, but the heating system is ready to operate. Also, it is automatically put into the operation and maintains a room temperature of 8 C whenever there is a risk of frost in the living room. 10) Indication of the actual mode of operation Window is red: normal heating program. Window is blue: reduced heating program. 11) Override Switch This switch is used to manually override the automatic time switch program. This means that you can change over from normal (red) to reduced (blue) heating and vice versa. After the next switching operation, the heating system returns to the automatic time switch program. Note: The override switch is operative only if; - The program selector slider (9) is set to (9a) - The last automatic switching operation took place more than 45 minutes ago. 12) Battery Check This light is used to check the condition of the batteries. Procedure: Move the program selector slider (9) upwards: - Red lamp lights up: Batteries are still in good condition. - Red lamp does not light up: replace batteries with new ones. 13) Operation Check Must turn (in steps of seconds) 14) Instructions for replacing the battery Batteries are replaced every 4 to 5 years (see also item 20). Siemens Building Technologies/HVAC Products RAV91 4/6

Heating and Saving Tips Maintain your room temperature at 20 C to 21 C (4), never above, because every additional degree increases your heating costs by 6 to 7 percent. However, if you feel comfortable at 18 C then set the temperature to 18 C and you reduce your heating costs by 6 to 7 percent. When you sleep, you lie in your warm bed. So why should you maintain normal room temperature? Reduce the temperature at night (5) to perhaps 12 C or 15 C. If you leave the house for more than two hours (when you go shopping, for example), set your heating system to reduced operation (10). If you are absent for several days (e.g. holidays, weekends), you should set your heating system to frost protection operation (9d). Check if your heating system does not switch too early to normal temperature and too late to reduced temperature. If necessary, change the switching times (6a) (6b) (7a) (7b). Renewing the room air by having the windows slightly open is expensive, so don t do it. Renew the room air by opening the windows fully, but only for short periods of time. If you don t have the thermostatic radiator valves in your house, it s time to fit them, because they reduce the consumption of heat. Contact your heating installer and ask for RADIAGYR. During the warm season, when heating is not required, you should switch off your heating installation on the room unit (17). Did you know - That with CHRONOGYR you can heat less at night, i.e., the room temperature can be reduced. (5) - That you can also heat less during the day, if you are a working couple. (5) (7). - That CHRONOGYR operates your heating system fully automatically according to a pre selected program (6) (7) (8). - That you can switch the automatic heating program off without erasing it (9). - That with CHRONOGYR you can operate and also switch off your heating system from your living room. - That CHRONOGYR switches your heating system automatically off when it is warm enough outside and on again, when this becomes necessary. Siemens Building Technologies/HVAC Products RAV91 5/6

- That CHRONOGYR offers energy savings with frost protection operation when you leave the house for several days (e.g. during your holiday). (9d) Replacing the Batteries 1) Insert screw driver in the slot of the black baseplate and press slightly down. (see fig. 1) 2) Remove unit by swinging it upwards (see fig. 2). 3) Remove old batteries (3 pieces) and replace by new batteries according to symbols. Recommended type of battery: Alkaline type, leaking proof. 4) Replace unit in baseplate an swing downward (must engage in baseplate) 5) Check if the unit is fitted properly. 6) Set correct time. Siemens Building Technologies/HVAC Products RAV91 6/6