Deluge/Preaction Systems Annotated Instructor s Guide

Similar documents
Deluge/Preaction Systems Annotated Instructor s Guide

Hangers, Supports, Restraints, and Guides Annotated Instructor s Guide

System Layout Annotated Instructor s Guide

Contren Learning Series Apprenticeship Training Program for Fire Sprinkler Fitters

This module introduces trainees to the various types of all-air systems used in commercial buildings.

Orientation to the Electrical Trade Annotated Instructor s Guide

This module describes basic calculation procedures and calculations for commercial and residential applications.

PLAN REVIEW CHECKLIST

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS

CONSTRUCTION REQUIREMENTS

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

SECTION SPRINKLER SYSTEMS

COURSE OUTLINE Fire Protection Systems

Sprinkler System Installer Level 2

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

Gas Station & C Store SECTION CWM Job No

Becoming an Expert on Dry-pipe, Preaction, and Deluge Sprinkler Systems

TECHNICAL DATA OBSOLETE

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

SECTION WET-PIPE SPRINKLER SYSTEMS

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

New Construction Fire Inspection Process

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

Port of St Helens SIA Aircraft Hanger Scappoose, OR

TOTALPAC2 Integrated Fire Protection System

SUMMARY. Building receiving sprinkler credit: SPRINKLERED. Grade: 68. Percent of Building Sprinklered: 100% Sprinkler Demand Met: 91%

Refer to the specific sprinkler or spray nozzle technical data pages for sprinkler listings and approvals.

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

SECTION FIRE PUMP AND CONTROLS

TECHNICAL DATA. Viking Technical Data may be found on. The Viking Corporation s Web site at.

esfr pendent sprinkler vk510 (k25.2)

standard response elo upright and pendent sprinklers (storage-density/area)

A. This section includes design and performance information for fire protection and suppression systems.

esfr pendent sprinkler vk510 (k25.2)

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

False Sense of Security???

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

SECTION ELECTRIC-DRIVEN, FIRE PUMPS

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

2. Welding Materials and Procedures shall conform to the ASME Code.

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

SECTION Fire Pumps

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

SYLLABUS. Departmental Syllabus. Fire Protection Equipment Alarm Systems. Departmental Syllabus. Departmental Syllabus. Departmental Syllabus

RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS

Fire Protection Systems FST 209. COURSE SYLLABUS Fire Protection Systems FST 209 [Semester] CRN 3 Credits

standard response/ quick response extended coverage

SAN DIEGO COMMUNITY COLLEGE DISTRICT MIRAMAR COLLEGE ASSOCIATE DEGREE COURSE OUTLINE

Sprinkler Permit Applications

ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA

quick response Sprinkler 105a October 25, 2010

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Advanced Integrated Fire Protection Systems TOTALPAC 2. Owner's Operation and Maintenance Manual FIRECYCLE III. September 2009 FM-086G-0-5E

Report of Inspection/Test

SECTION : FIRE PROTECTION SYSTEMS

SECTION FIRE SUPPRESSION SYSTEMS

Sprinkler Standards Proposed Technical Changes

ADDENDUM #1 ITB# Fire Protection Maintenance Services Responses to Clarification Questions 10/06/2015

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

micromatic standard response stainless steel sprinklers

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

Inspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems

B. Section Identification for Fire Suppression Piping and Equipment.

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

MODULE 2. Water-Based Suppression System Basics

DIVISION 21 - FIRE SUPPRESSION

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

standard response fusible link sidewall sprinkler VK112 (K5.6)

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

System Test Report CLEAN AGENT

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

microfast sr/qr extended coverage pendent sprinkler

TECHNICAL DATA OBSOLETE

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

SECTION WET-PIPE SPRINKLER SYSTEMS

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

Transcription:

Deluge/Preaction Systems Annotated Instructor s Guide Module 18301-07 Module Overview This module covers different types of preaction and deluge systems. It discusses deluge valves, auxiliary detection systems, release systems, and hydraulic and pneumatic activation. It also covers installation and troubleshooting techniques. Prerequisites Prior to training with this module, it is recommended that the trainee shall have successfully completed Core Curriculum; Sprinkler Fitting Level One; and Sprinkler Fitting Level Two. Objectives Upon completion of this module, the trainee will be able to do the following: 1. Identify and explain differences between deluge and preaction systems. 2. Identify the critical components of a deluge system and a preaction system. 3. Explain where preaction systems and deluge systems are generally installed. 4. Trip and reset a deluge valve. 5. Identify the three types of discharge nozzles used with a deluge system. 6. Identify and explain various methods of activating electrical release and electrical supervision. 7. Demonstrate the procedures to place a Firecycle system in service. 8. Identify and explain non-, single-, and double-interlocked preaction systems. 9. Explain the main precautions that must be observed when placing non-, single-, and doubleinterlocked systems into service and describe activation. 10. Perform a hydrostatic test. Performance Tasks Under the supervision of the instructor, the trainee should be able to do the following: 1. Trip and reset a deluge valve. 2. Demonstrate the procedures to place a Firecycle system in service. 3. Using charts provided by your instructor, identify the differences between double-air-locked, single air-locked, pneumatic, and electric preaction systems. 4. Perform a hydrostatic test. Materials and Equipment Multimedia projector and screen Sprinkler Fitting Level Three PowerPoint Presentation Slides (ISBN 978-0-13-272926-0) Computer Whiteboard/chalkboard Markers/chalk Pencils and scratch paper Appropriate personal protective equipment Basic trainee tools Measuring tape Calculator Deluge valves Manufacturers literature on hydraulic release mechanisms Standard sprinkler heads and associated manufacturers literature Fixed-temperature releases and associated manufacturers literature Rate-of-rise releases and associated manufacturers literature Deluge valve with a pneumatic release system Electric release mechanisms and associated manufacturers literature Protectowire, accessories, and manufacturer s literature Electrical thermostats Infrared detectors and manufacturers literature continued

Manufacturers installation literature on preaction systems*** Discharge nozzles Thermostatic release devices Release setting tool kit Heat-activated device Various detectors Mercury checks Air tubing Rate compensating valve Quick Quiz* Module Examinations** Performance Profile Sheets** * Located at the back of this module ** Single-module AIG purchases include the printed exam and performance task sheet. If you have purchased the perfect-bound version of this title, download these materials from the IRC using your access code. *** Training graphics and posters are available from major manufacturers. For example, Viking corporation produces system posters that are available by making a Viking literature request, or by contacting the local sales office. Posters that are available include: Deluge system Preaction system Surefire single-interlock system Firecycle III system Foam/water deluge sprinkler system Safety Considerations Ensure that trainees are equipped with appropriate personal protective equipment and know how to use it properly. This module may require that trainees visit job sites. Ensure that trainees are briefed on site safety policies prior to any site visits. This module requires trainees to work with sprinkler systems and perform hydrostatic testing. Ensure all trainees are briefed on appropriate safety procedures. Additional Resources This module presents thorough resources for task training. The following resource material is suggested for further study. Automatic Fire Sprinkler Handbook, Latest Edition. Quincy, MA: National Fire Protection Association. NFPA 13, Latest Edition. Quincy, MA: National Fire Protection Association. NFPA 25, Latest Edition. Quincy, MA: National Fire Protection Association. NFPA 72, Latest Edition. Quincy, MA: National Fire Protection Association. Teaching Time For This Module An outline for use in developing your lesson plan is presented below. Note that each Roman numeral in the outline equates to one session of instruction. Each session has a suggested time period of 2 1 2 hours. This includes 10 minutes at the beginning of each session for administrative tasks and one 10-minute break during the session. Approximately 40 hours are suggested to cover Deluge/Preaction Systems. You will need to adjust the time required for hands-on activity and testing based on your class size and resources. Because laboratories often correspond to Performance Tasks, the proficiency of trainees may be noted during these exercises for Performance Testing purposes. Topic Planned Time Sessions I through III. Introduction; Deluge Systems A. Introduction B. Deluge Systems C. Deluge System Components Using a Fixed Piping Network D. Deluge Valves E. Release Mechanisms for Deluge Systems F. Hanger Connecting Units and Attachments

G. Detection Systems for Electric Release Mechanisms H. Laboratory Have trainees practice tripping and resetting a deluge valve. This laboratory corresponds to Performance Task 1. Sessions IV through VI. Preaction Systems A. Preaction Systems B. Non-Interlocked Preaction Systems C. Single-Interlocked Preaction Systems D. Double-Interlocked Preaction Systems E. Laboratory Have trainees practice identifying the differences between different types of preaction systems. This laboratory corresponds to Performance Task 3. Sessions VII through X. Firecyle Systems A. Firecyle Systems B. Core System Components C. System Components D. Maintenance E. Firecyle III F. Laboratory Have trainees practice demonstrating the procedures to put a Firecyle system in service. This laboratory corresponds to Performance Task 2. Sessions XI through XV. Trim; Installation Techniques; Troubleshooting A. Packaged Trim and Packaged Systems B. Installation Precautions C. Preparation for Hydrostatic Testing D. Hydrostatic Test Demonstration E. Laboratory Have trainees practice performing a hydrostatic test. This laboratory corresponds to Performance Task 4. F. Troubleshooting Auxiliary Detection Systems Session XVI. Review and Testing A. Module Review B. Module Examination 1. Trainees must score 70% or higher to receive recognition from NCCER. 2. Record the testing results on Training Report Form 200, and submit the results to the Training Program Sponsor. C. Performance Testing 1. Trainees must perform each task to the satisfaction of the instructor to receive recognition from NCCER. If applicable, proficiency noted during laboratory exercises can be used to satisfy the Performance Testing requirements. 2. Record the testing results on Training Report Form 200, and submit the results to the Training Program Sponsor.

Standpipes Annotated Instructor s Guide Module 18302-07 Module Overview This module identifies and explains wet and dry standpipes; describes standpipe sizing, classification, and building codes; and reviews standards that must be followed for installation. It explains fire department connections, sleeves, bracing, and fire stopping. Prerequisites Prior to training with this module, it is recommended that the trainee shall have successfully completed Core Curriculum; Sprinkler Fitting Level One; Sprinkler Fitting Level Two; and Sprinkler Fitting Level Three, Module 18301-07. Objectives Upon completion of this module, the trainee will be able to do the following: 1. Identify the different types and classifications of standpipes. 2. Explain the requirements for standpipes for buildings under construction. 3. Explain the basic requirements for sizing standpipes hydraulically and by schedule. 4. Describe a hose rack assembly and how it works. 5. Describe roof manifolds. 6. Identify and explain fire department connections. 7. Identify types of hose valves and adapters. 8. Demonstrate flow test procedures used to validate minimum pressure and flow capability. 9. Identify, test, and adjust a pressure-reducing valve (PRV). 10. Demonstrate LINK-SEAL installation procedures. Performance Tasks Under the supervision of the instructor, the trainee should be able to do the following: 1. Identify differences in valve size between Class I, II, and III standpipes. 2. Demonstrate flow test procedures used to validate minimum pressure and flow capability. 3. Identify standpipe components from schematics. 4. Pull hoses out of a cabinet and reassemble. 5. Identify different types of valves. 6. Adjust a PRV. Materials and Equipment Multimedia projector and screen Sprinkler Fitting Level Three PowerPoint Presentation Slides (ISBN 978-0-13-272926-0) Computer Whiteboard/chalkboard Markers/chalk Pencils and scratch paper Appropriate personal protective equipment Basic trainee tools Measuring tape Calculator Standpipe schematics NFPA 14 Building and fire codes Hose racks Cabinets Roof manifolds Fire department connections Various styles of hose valves Pressure-reducing valves and manufacturers literature Sleeves continued

Clamps Sway bracing Link-Seal assembly and instructions Quick Quiz* Module Examinations** Performance Profile Sheets** * Located in the back of this module ** Single-module AIG purchases include the printed exam and performance task sheet. If you have purchased the perfect-bound version of this title, download these materials from the IRC using your access code. Safety Considerations Ensure that trainees are equipped with appropriate personal protective equipment and know how to use it properly. This module may require that trainees visit job sites. Ensure that trainees are briefed on site safety policies prior to any site visits. This module requires trainees to work with sprinkler systems and pressure reducing valves. Ensure all trainees are briefed on appropriate safety procedures. Additional Resources This module presents thorough resources for task training. The following resource material is suggested for further study. Automatic Fire Sprinkler Handbook, Latest Edition. Quincy, MA: National Fire Protection Association. NFPA 13, Latest Edition. Quincy, MA: National Fire Protection Association. NFPA 14, Latest Edition. Quincy, MA: National Fire Protection Association. NFPA Fire Protection & Fire Service Reference Directory, Latest Edition. Quincy, MA: National Fire Protection Association. Underwriters Laboratories Fire Protection Equipment Directory, Northbrook, IL: Underwriters Laboratories Inc. Teaching Time For This Module An outline for use in developing your lesson plan is presented below. Note that each Roman numeral in the outline equates to one session of instruction. Each session has a suggested time period of 2 1 2 hours. This includes 10 minutes at the beginning of each session for administrative tasks and one 10-minute break during the session. Approximately 25 hours are suggested to cover Standpipes. You will need to adjust the time required for hands-on activity and testing based on your class size and resources. Because laboratories often correspond to Performance Tasks, the proficiency of trainees may be noted during these exercises for Performance Testing purposes. Topic Planned Time Sessions I and II. Introduction and Standpipe Classification A. Introduction B. Standpipes C. Standpipe Classification D. Laboratory Have trainees practice identifying standpipe components from schematics. This laboratory corresponds to Performance Task 3. E. Standpipe System Types F. Standpipe Sizing G. Laboratory Have trainees practice identifying differences in valve sizes between Class I, II, and III standpipes. This laboratory corresponds to Performance Task 1.

Sessions III and IV. Testing A. Test Risers, Drains, and Main Drain Test Connections B. Hydrostatic Tests C. Flow Tests D. Laboratory Have trainees practice demonstrating flow test procedures. This laboratory corresponds to Performance Task 2. E. Minimum Flow Capability Session V. Standpipe Requirements A. Standpipe Requirement Sources B. Standpipe Requirements C. Standpipe Installation Session VI. Standpipe Appurtenances, Part One A. Hose Racks B. Cabinets C. Laboratory Have trainees practice pulling hoses out of cabinets and reassembling them. This laboratory corresponds to Performance Task 4. D. Roof Manifold E. Fire Department Connections Sessions VII and VIII. Standpipe Appurtenances, Part Two A. Valves B. Laboratory Have trainees practice identifying different types of valves. This laboratory corresponds to Performance Task 5. C. Pressure-Reducing Valves D. Laboratory Have trainees practice adjusting a PRV. This laboratory corresponds to Performance Task 6. Session IX. Sleeves, Clamps, Sway Bracing, and Link-Seal A. Sleeves B. Clamps C. Earthquake Protection D. Link-Seal Session X. Review and Testing A. Module Review B. Module Examination 1. Trainees must score 70% or higher to receive recognition from NCCER. 2. Record the testing results on Training Report Form 200, and submit the results to the Training Program Sponsor. C. Performance Testing 1. Trainees must perform each task to the satisfaction of the instructor to receive recognition from NCCER. If applicable, proficiency noted during laboratory exercises can be used to satisfy the Performance Testing requirements. 2. Record the testing results on Training Report Form 200, and submit the results to the Training Program Sponsor.

Water Supplies Annotated Instructor s Guide Module 18303-07 Module Overview This module identifies the chemical and physical properties of water and covers the different water supplies available for automatic sprinkler systems. It describes the types of tanks, water main configurations, flow test procedures, system meters, fire department connections, and split pit requirements. Prerequisites Prior to training with this module, it is recommended that the trainee shall have successfully completed Core Curriculum; Sprinkler Fitting Level One; Sprinkler Fitting Level Two; and Sprinkler Fitting Level Three, Modules 18301-07 and 18302-07. Objectives Upon completion of this module, the trainee will be able to do the following: 1. Recognize federal, state, and jurisdictional requirements for supply and disposal of fire sprinkler system water. 2. Identify different water supplies for automatic sprinkler systems. 3. Explain the three qualities that are critical to the water supply for fire sprinkler systems. 4. Identify types of water storage and explain their usage. 5. Describe different water main configurations. 6. Perform flow test procedures. 7. Plot residual and static pressure on a graph. 8. Read a flow test results sheet and determine the number of outlets flowed, hydrant outlet size, and static and residual pressure. 9. Fill out a flow test summary sheet. 10. Identify and describe backflow preventers and methods of installation. 11. Identify and describe meters used in fire sprinkler systems. Performance Tasks Under the supervision of the instructor, the trainee should be able to do the following: 1. Perform flow test procedures. 2. Plot residual and static pressure on a graph. 3. Read a flow test results sheet and determine the number of outlets flowed, hydrant outlet size, and static and residual pressure. 4. Fill out a flow test summary sheet. Materials and Equipment Multimedia projector and screen Sprinkler Fitting Level Three PowerPoint Presentation Slides (ISBN 978-0-13-272926-0) Computer Whiteboard/chalkboard Markers/chalk Pencils and scratch paper Appropriate personal protective equipment Basic trainee tools Measuring tape Calculator Standpipe schematics Hydrant wrenches Tapped hydrant caps Air chambers Detector check valves Backflow preventers Check valve assembly continued

Water supply maps Fire department connections Municipal water supply map Flow test reports Pitot tubes Static/residual pressure gauges Pitot tube pressure gauges Hydrant diffusers Disc-type meter Compound meter Turbine meter Quick Quizzes* Module Examinations** Performance Profile Sheets** * Located in the back of this module. ** Single-module AIG purchases include the printed exam and performance task sheet. If you have purchased the perfect-bound version of this title, download these materials from the IRC using your access code. Safety Considerations Ensure that trainees are equipped with appropriate personal protective equipment and know how to use it properly. This module may require that trainees visit job sites. Ensure that trainees are briefed on site safety policies prior to any site visits. This module requires trainees to work with sprinkler systems. Ensure all trainees are briefed on appropriate safety procedures. Additional Resources This module presents thorough resources for task training. The following resource material is suggested for further study. Automatic Fire Sprinkler Handbook, Latest Edition. Quincy, MA: National Fire Protection Association. Manual M-14, Latest Edition. Denver, CO: American Water Works Association. NFPA 13, Latest Edition. Quincy, MA: National Fire Protection Association. NFPA 22, Standard for Water Tanks for Private Fire Protection, Latest Edition. Quincy, MA: National Fire Protection Association. Recommended Practice for Backflow Prevention and Cross-Connection Control, Latest Edition. Norwood, MA: FM Global Engineering & Research. Teaching Time For This Module An outline for use in developing your lesson plan is presented below. Note that each Roman numeral in the outline equates to one session of instruction. Each session has a suggested time period of 2 1 2 hours. This includes 10 minutes at the beginning of each session for administrative tasks and one 10-minute break during the session. Approximately 15 hours are suggested to cover Water Supplies. You will need to adjust the time required for hands-on activity and testing based on your class size and resources. Because laboratories often correspond to Performance Tasks, the proficiency of trainees may be noted during these exercises for Performance Testing purposes. Topic Planned Time Sessions I and II. Introduction to Water Supplies A. Introduction B. Water Chemistry C. Water Supplies D. Tank Types E. Infrastructure

Sessions III and IV. Testing A. Measuring Water Supply Capability B. Flow Tests C. Laboratory Have trainees practice performing flow test procedures. This laboratory corresponds to Performance Task 1. D. Plotting Information E. Laboratory Have trainees practice plotting residual and static pressure on a graph. This laboratory corresponds to Performance Task 2. F. Laboratory Have trainees practice reading a flow test results sheet, determining the number of outlets flowed, hydrant outlet size, and static and residual pressure. This laboratory corresponds to Performance Task 3. G. Laboratory Have trainees practice filling out a flow test summary sheet. This laboratory corresponds to Performance Task 4. Session V. Water Supply Appurtenances A. Water Purveyor B. Meters C. Detector Check Valves D. Backflow Preventers E. Fire Department Connections F. Pits Session VI. Review and Testing A. Module Review B. Module Examination 1. Trainees must score 70% or higher to receive recognition from NCCER. 2. Record the testing results on Training Report Form 200, and submit the results to the Training Program Sponsor. C. Performance Testing 1. Trainees must perform each task to the satisfaction of the instructor to receive recognition from NCCER. If applicable, proficiency noted during laboratory exercises can be used to satisfy the Performance Testing requirements. 2. Record the testing results on Training Report Form 200, and submit the results to the Training Program Sponsor.

Fire Pumps Annotated Instructor s Guide Module 18304-07 Module Overview This module identifies and explains various fire pump systems, pumps, and drivers, controllers, and sensing lines. It describes supervision and project requirement checklists. Testing, maintenance, and troubleshooting are discussed, as well as inspection and maintenance in existing pump rooms and frequently encountered problems. Prerequisites Prior to training with this module, it is recommended that the trainee shall have successfully completed Core Curriculum; Sprinkler Fitting Level One; Sprinkler Fitting Level Two; and Sprinkler Fitting Level Three, Modules 18301-07 through 18303-07. Objectives Upon completion of this module, the trainee will be able to do the following: 1. Explain the basic components and types that make up a fire pump system. 2. Identify the NFPA standard that covers the installation of fire pumps. 3. Explain the minimum residual pressure in pounds per square inch (psi) that can be used when pumping from a municipal water supply. 4. Convert pressure ratings from psi to feet of head and vice versa. 5. Explain how to set and align a pump. 6. Discuss the different types of and requirements for fire pump controllers. 7. Discuss monitoring requirements for fire pumps. 8. Describe acceptance testing of fire pumps. 9. Perform a mechanical check of a fire pump system. 10. Measure the flow of a system. 11. Identify potential causes for a malfunctioning fire pump. Performance Tasks Under the supervision of the instructor, the trainee should be able to do the following: 1. Identify different fire pump elements such as pumps, drivers, strainers, pump controllers, bypasses, test headers, and flow meters. 2. Identify potential causes for a malfunctioning fire pump. 3. Perform a mechanical check of a fire pump system. 4. Measure the flow of a system. 5. Troubleshoot the cause and give corrective action for a malfunctioning fire pump. Materials and Equipment Multimedia projector and screen Sprinkler Fitting Level Three PowerPoint Presentation Slides (ISBN 978-0-13-272926-0) Computer Whiteboard/chalkboard Markers/chalk Pencils and scratch paper Appropriate personal protective equipment Basic trainee tools Measuring tape Calculator Standpipe schematics Hydrant wrenches Alignment tools Pumps Drivers Meters Nozzles Mercoid switches Controllers continued

NFPA 20 Flow meters Jockey pumps Eccentric suction reducers Concentric discharge increasers Pump casing relief valves Automatic air release valves Relief valves String and weight or other centrifugal device Centrifugal pump and rotor Horizontal split-case pump Vertical in-line pumps Vertical turbine pumps Electric driver Pump performance curves Civil checklists Mechanical and electrical checklists Operating and maintenance manuals Various types of flow meters Quick Quizzes* Module Examinations** Performance Profile Sheets** * Located at the back of this module. ** Single-module AIG purchases include the printed exam and performance task sheet. If you have purchased the perfect-bound version of this title, download these materials from the IRC using your access code. Safety Considerations Ensure that trainees are equipped with appropriate personal protective equipment and know how to use it properly. This module may require that trainees visit job sites. Ensure that trainees are briefed on site safety policies prior to any site visits. This module requires trainees to work with fire pumps. Ensure all trainees are briefed on appropriate safety procedures. Additional Resources This module presents thorough resources for task training. The following resource material is suggested for further study. NFPA 13, Latest Edition. Quincy, MA: National Fire Protection Association. NFPA 13D, Latest Edition. Quincy, MA: National Fire Protection Association. NFPA 20, Latest Edition. Quincy, MA: National Fire Protection Association. NFPA 70, Latest Edition. Quincy, MA: National Fire Protection Association. Teaching Time For This Module An outline for use in developing your lesson plan is presented below. Note that each Roman numeral in the outline equates to one session of instruction. Each session has a suggested time period of 2 1 2 hours. This includes 10 minutes at the beginning of each session for administrative tasks and one 10-minute break during the session. Approximately 40 hours are suggested to cover Fire Pumps. You will need to adjust the time required for hands-on activity and testing based on your class size and resources. Because laboratories often correspond to Performance Tasks, the proficiency of trainees may be noted during these exercises for Performance Testing purposes. Topic Planned Time Sessions I and II. Introduction to Fire Pump Systems A. Introduction B. Fire Pump Categories and System Functions C. Rated Enclosure D. Fire Pump System Elements E. Fire Pump Performance Requirements F. Fire Pump Alignment

Sessions III through V. Pumps and Drivers A. Centrifugal Pumps B. Pump Types C. Driver History D. Driver Types (Electric, Gas, Diesel, Steam) E. Laboratory Have trainees practice identifying different fire pump elements. This laboratory corresponds to Performance Task 1. F. Pump Performance Curves Sessions VI and VII. Controllers, Sensing Lines, and Supervision A. Controller Functions B. Cabinet Styles C. Controllers D. Starting Mechanisms E. Transfer Switches F. Sensing Controls G. Supervision Session VIII. Project Checklists, Installation, and Startup A. Civil Checklist B. Mechanical and Electrical Checklists C. Environmental Issues D. Introduction to Pump Room Equipment Sessions IX and X. Installation and Testing A. The Test Header B. Flow Meters C. Pre-Startup Procedures D. Electric Fire Pump Checklist E. Laboratory Have trainees practice measuring the flow of a system. This laboratory corresponds to Performance Task 4. F. Diesel Fire Pump Installation Checklist G. Laboratory Have trainees practice performing a mechanical check of a fire pump system. This laboratory corresponds to Performance Task 3. Sessions XI and XII. Periodic Maintenance and Troubleshooting A. Weekly Test Procedures B. Six-Month Preventive Maintenance C. Troubleshooting D. Laboratory Have trainees practice troubleshooting a system. This laboratory corresponds to Performance Task 5. Sessions XIII through XV. Existing Pump Rooms A. Inspection of Existing Pump Rooms B. Frequently Encountered Problems C. Laboratory Have trainees practice identifying potential causes for a malfunctioning fire pump. This laboratory corresponds to Performance Task 2.

Session XVI. Review and Testing A. Module Review B. Module Examination 1. Trainees must score 70% or higher to receive recognition from NCCER. 2. Record the testing results on Training Report Form 200, and submit the results to the Training Program Sponsor. C. Performance Testing 1. Trainees must perform each task to the satisfaction of the instructor to receive recognition from NCCER. If applicable, proficiency noted during laboratory exercises can be used to satisfy the Performance Testing requirements. 2. Record the testing results on Training Report Form 200, and submit the results to the Training Program Sponsor.

Application-Specific Sprinklers and Nozzles Annotated Instructor s Guide Module 18305-07 Module Overview This module introduces special sprinklers and nozzles. It covers various types of sprinklers and nozzles and the area of coverage, positioning, and obstruction requirements. Prerequisites Prior to training with this module, it is recommended that the trainee shall have successfully completed the Core Curriculum; Sprinkler Fitting Level One; Sprinkler Fitting Level Two; and Sprinkler Fitting Level Three, Modules 18301-07 through 18304-07. Objectives Upon completion of this module, the trainee will be able to do the following: 1. Identify, describe, and explain application-specific sprinklers. 2. Explain areas of coverage, positioning, and obstruction requirements. 3. Select correct types of sprinklers based on occupancy and obstruction requirements. 4. Select proper escutcheon for recess sprinklers. 5. Identify and explain nozzles. 6. Describe different types of nozzles. 7. Size and install dry sprinklers. 8. Size and install an attic sprinkler. Performance Tasks Under the supervision of the instructor, the trainee should be able to do the following: 1. Select correct types of sprinklers based on occupancy and obstruction requirements. 2. Select the proper escutcheon for recess sprinklers. 3. Size and install dry sprinklers. 4. Install an attic sprinkler on a swing joist so as to align with the pitch of the roof. Materials and Equipment Multimedia projector and screen Sprinkler Fitting Level Three PowerPoint Presentation Slides (ISBN 978-0-13-272926-0) Computer Whiteboard/chalkboard Markers/chalk Pencils and scratch paper Appropriate personal protective equipment Basic trainee tools Measuring tape Calculator Extended coverage upright and pendent sprinklers Extended coverage sidewall sprinklers Residential sprinklers and manufacturers literature Control mode specific application (CMSA) sprinklers Early suppression fast response (ESFR) sprinklers Intermediate level sprinklers Dry sprinklers Hangers and supports Pipe Tools and supplies for installing sprinklers Institutional sprinklers On-off sprinklers Attic sprinklers Combustible concealed space sprinklers Nozzles Quick Quiz* Module Examinations** Performance Profile Sheets** * Located at the back of this module. ** Single-module AIG purchases include the printed exam and performance task sheet. If you have purchased the perfect-bound version of this title, download these materials from the IRC using your access code.

Safety Considerations Ensure that trainees are equipped with appropriate personal protective equipment and know how to use it properly. This module may require that trainees visit job sites. Ensure that trainees are briefed on site safety policies prior to any site visits. This module requires trainees to work with sprinkler systems. Ensure all trainees are briefed on appropriate safety procedures. Additional Resources This module presents thorough resources for task training. The following resource material is suggested for further study. Automatic Sprinkler Handbook, Latest Edition. Quincy, MA: National Fire Protection Association. A Reference Guide to Automatic Sprinklers, Latest Edition. Dallas, TX: American Fire Sprinkler Association. FM Global Approval Guide, Latest Edition. Norwood, MA: FM Global. NFPA 13, Latest Edition. Quincy, MA: National Fire Protection Association. NFPA 13R, Latest Edition. Quincy, MA: National Fire Protection Association. NFPA 15, Latest Edition. Quincy, MA: National Fire Protection Association. NFPA 16, Latest Edition. Quincy, MA: National Fire Protection Association. NFPA 214, Latest Edition. Quincy, MA: National Fire Protection Association. Underwriters Laboratories Fire Protection Equipment Directory, Latest Edition. Northbrook, IL: Underwriters Laboratories Inc. Teaching Time For This Module An outline for use in developing your lesson plan is presented below. Note that each Roman numeral in the outline equates to one session of instruction. Each session has a suggested time period of 2 1 2 hours. This includes 10 minutes at the beginning of each session for administrative tasks and one 10-minute break during the session. Approximately 27 1 2 hours are suggested to cover Application-Specific Sprinklers and Nozzles. You will need to adjust the time required for hands-on activity and testing based on your class size and resources. Because laboratories often correspond to Performance Tasks, the proficiency of trainees may be noted during these exercises for Performance Testing purposes. Topic Planned Time Sessions I through IV. Introduction; Special Sprinklers A. Introduction B. Extended Coverage Upright and Pendent Sprinklers C. Extended Coverage Sidewall Sprinklers D. Residential Sprinklers E. CMSA Sprinklers F. Early Suppression Fast Response Sprinklers G. Intermediate Level Sprinklers H. Laboratory Have trainees practice selecting the correct type of sprinklers based on occupancy and obstruction requirements. This laboratory corresponds to Performance Task 1. I. Laboratory Have trainees practice selecting proper escutcheon for recess sprinklers. This laboratory corresponds Performance Task 2.

Sessions V and VI. Dry and Institutional Sprinklers A. Dry Sprinklers B. Dry Sprinklers in Freezers C. Laboratory Have trainees practice sizing and installing dry sprinklers. This laboratory corresponds to Performance Task 3. D. Institutional Sprinklers Sessions VII through IX. Periodic Maintenance and Troubleshooting A. On-Off Sprinklers B. Special Sprinklers C. Attic Sprinklers D. Laboratory Have trainees practice installing an attic sprinkler. This laboratory corresponds to Performance Task 4. Session X. Nozzles and Coatings A. Nozzles B. Corrosion-Resistant Coatings Session XI. Review and Testing A. Module Review B. Module Examination 1. Trainees must score 70% or higher to receive recognition from NCCER. 2. Record the testing results on Training Report Form 200, and submit the results to the Training Program Sponsor. C. Performance Testing 1. Trainees must perform each task to the satisfaction of the instructor to receive recognition from NCCER. If applicable, proficiency noted during laboratory exercises can be used to satisfy the Performance Testing requirements. 2. Record the testing results on Training Report Form 200, and submit the results to the Training Program Sponsor.