RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS

Similar documents
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

MONTECITO FIRE PROTECTION DISTRICT

2009 International Residential Code Draft of New Fire Sprinkler Related Requirements

RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

What You Need to Know about Residential Sprinkler Design

Zurn Pex, Inc. Residential Fire Protection Presentation. PEX Plumbing, Radiant Heating and Residential Fire Protection Systems

What Builders Need to Know about Residential Sprinkler Design

FIRE SUPPRESSION SPRINKLER SYSTEM

DESIGN & CONSTRUCTION GUIDELINES

Fire District Dwelling Construction Requirements

Sprinkler Permit Applications

Fire Sprinkler System Design and Installation Requirements

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

SECTION : FIRE PROTECTION SYSTEMS

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

FIRE SPRINKLER SYSTEMS POLICY

Best Practices Guide. for Residential Fire Sprinklers

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

McMAHON FP200 OUTAGAMIE COUNTY ADMINISTRATION CENTER S. WALNUT & W. 8TH, APPLETON, WI ALTERATION / ADDITION

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

City of Vista Fire Department

FIRE ALARM APPLICATION CITY OF MADISON HEIGHTS

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

FIRE SPRINKLER SYSTEMS POLICY

Center for Life Safety Education

ADDENDUM NO. 3 March 19, 2018

September 30, Dear Fire Suppression System Contractor/Designer:

CITY OF PASADENA FIRE DEPARTMENT

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

AUTOMATIC FIRE SPRINKLER SYSTEMS

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Design & Construction Standards, Revised January

Deluge/Preaction Systems Annotated Instructor s Guide

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

APPENDIX H (DESIGN SUBMISSION CRITERIA)

2. Welding Materials and Procedures shall conform to the ASME Code.

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

Commercial Remodel/ Add On Rules and Regulations

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

SECTION POLICY MANUAL

May 1, Dear Fire Suppression System Contractor/Designer:

Commercial Rules and Regulations

PLAN REVIEW CHECKLIST

Deluge/Preaction Systems Annotated Instructor s Guide

Port of St Helens SIA Aircraft Hanger Scappoose, OR

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

Fire Permit Application

Fire Sprinkler Submittal Requirements and Acceptance Testing

WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12" 12" 24"

FIRE SPRINKLER SHOP DRAWING SUBMITTAL REQUIREMENTS

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

1.3 REFERENCE STANDARDS

A. This section includes design and performance information for fire protection and suppression systems.

ALTERNATE METHODS FOR COMPLIANCE WITH THE 2003 INTERNATIONAL RESIDENTIAL CODE (IRC) & GARAGE FIRE SUPPRESSION SYSTEM

2016 California Building Code Adoption OC amendments Summary Title/Subject Justification/Comments Action

DIVISION 21 FIRE SUPPRESSION

State Board of Examiners of Plumbing, Heating & Fire Sprinkler Contractors. Residential Fire Sprinkler Inspections

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

SPRINKLER PROTECTION OF COMBUSTIBLE CONCEALLED SPACES WITH LESS THAN 6 BETWEEN OPPOSITE FACES IN CAVITY.

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

TABLE OF CONTENTS ADOPTED FIRE CODES... 3 AFPD SERVICE AREA... 3 SITE AND DEVELOPMENT SUBMITTAL REQUIREMENTS... 4 PLAN REVIEW FEES...

SECTION WET-PIPE SPRINKLER SYSTEMS

Photovoltaic (Solar) Array Installation Guide

Brighton Area Fire Authority

Fire Sprinklers The Ultimate Fire Fighters Eric Skare

Apply & Pay for Building Permits on Accela Citizen Access

NZS 4517:2010. New Zealand Standard. Fire sprinkler systems for houses. Superseding NZS 4517:2002 NZS 4517:2010

FIRE DEPARTMENT SYSTEM PERMIT APPLICATION

VILLAGE OF DOWNERS GROVE Report for the Village Council Meeting

Report: Summary of Building Codes Division Process, Residential Fire Sprinklers December 2008

CONSTRUCTION REQUIREMENTS

SECTION SPRINKLER SYSTEMS

SECTION RECORD DOCUMENTS and FIELD ENGINEERING

New Rehabilitated Area (ft 2 ) Private Homeownerinstalled

Plan Submittal Checklist

The definitions provided in , C.R.S., apply to these rules and regulations. The following additional definitions also apply:

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

FIRE SUPPRESSION SYSTEM REVIEW APPLICATION 1. NEW PLAN REVIEW RESUBMITTAL

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS

FIRE & LIFE SAFTEY STANDARD

Sandwich Community Fire Protection District. Plan Review Submittal Guidelines and Requirements

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

To expedite the plan review and inspection processes, please refer to the information below.

NFPA Edition Update

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

El Reno Fire Department Fire Alarm Plan Review Worksheet

Commercial Application/Plan Review Submittal Checklist

Orange Township Fire Department Fire Prevention Bureau

Transcription:

History: RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS Per the City adopted 2009 IRC, section R313, automatic fire sprinkler systems are required for all one and two family dwellings and townhomes. Per a City amendment, the implementation date of these code provisions was set at January 1, 2013. As of January 1, 3013, the City proceeded with the implementation of residential fire sprinklers. Fire sprinklers are not required for additions or alterations to existing buildings. Multi-purpose vs Stand-alone: There are basically two types of residential fire sprinklers systems multi-purpose and stand-alone. Multi-purpose systems are handled through the City. This includes submittal review, permitting, fees, and inspections. Stand-alone systems are handled by the City Fire Division. This includes plan review, permitting, fees, and inspections. In the case of stand-alone systems, separate permits are issued by the City Fire division, as well as separate permit fees are assessed. Permits for stand-alone fire sprinkler system are to be submitted after the Building permit has been submitted. permit issuance will not be delayed should a stand-alone system submittal not be received or approved by the Fire Division. Installation of the water service line will not be allowed until a fire sprinkler submittal has been received, reviewed, and approved by the City. With a stand-alone system, the branch point between the domestic water system and the fire sprinkler system is to occur within the dwelling. Any questions regarding stand-alone fire sprinkler systems should be directed to Mike Schafer, Fire Lieutenant-Fire Plans Examiner, at 303-658-4544. General requirements for submitting a Multi-purpose system. The complete fire sprinkler submittal for a multi-purpose system can be included with the building plans when submitting for a new residential build or can be handled as a deferred submittal. Provide a Building Permit Application form completely filled out. Updated 02/16/2016 Page 1 of 7

Clearly describe which standard, NFPA 13D or IRC 2904, that the system is being designed and installed under. Provide THREE copies of all documents other than application (only one copy of the application is required). Public Works / Water Department Requirements Street main system design pressures to be verified with the City Public Works division to insure that any future City infrastructure changes are incorporated into the design. Contact Public works Senior engineer Andy Walsh at 303-658-2563. Verify meter information: type, size, and friction loss with City. Design considerations All underground service lines from the main to the meter and from meter to house to be type K copper per City engineering standards. See appendix 2 for meter information. See appendix 3 for meter pit details Updated 02/16/2016 Page 2 of 7

APPENDIX 1 FIRE SPRINKLER SUBMITTALS ARE TO INCLUDE THE FOLLOW: System Design information Water supply information: o Date of test o Static pressure o Source of information (fire department, water purveyor, contractor) o Elevation change between water supply line and main floor elevation of house Water Service pipe information o Diameter and type of Water Service pipe between water supply and meter o Distance between water supply and meter o Diameter and type of pipe between meter and riser/ manifold / PRV/ or house shut off valve o Distance between water meter and house Pressure-reducing devices and friction loss data o Examples include backflow preventers, check valves, pressure-reducing valves, water softeners, water filters, and lawn irrigation systems. System layout and design; to include o Pipe layout o Location where Water Service pipe enters house o Type of sprinklers, i.e., recessed, concealed, pendant, upright, etc o Provide pipe sizing calculations. Provide either computer hydraulic calculations or if prescriptive based, indicated which tables used. Provide house construction information on the plans to include: o Information as to where vaulted, sloped, or cathedral ceilings occur. Indicate pitch and direction of slope for all pitches greater than 2:12. o Information on attic and concealed spaces. Include the type of insulation and its R value. Indicate how piping is being protected from freezing. o Information on floor framing, to include how girders / floor beams are being penetrated or routed around. o Information on unfinished spaces, to include whether pipe material will be metallic or what protection methods will be used. Updated 02/16/2016 Page 3 of 7

Hydraulic calculations (provide three copies) Product literature / cut sheets/ calculations (provide three copies) Sprinkler heads being used, to include temperature ratings and K-factor Pipe materials being used Backflow preventers, if used Pumps and storage tanks, if used Updated 02/16/2016 Page 4 of 7

APPENDIX 2 Updated 02/16/2016 Page 5 of 7

Updated 02/16/2016 Page 6 of 7

APPENDIX 3 Updated 02/16/2016 Page 7 of 7