UL TEST REPORT AND PROCEDURE

Similar documents
UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Dean King Dean King November 16, 2012

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

C E R T I F I C A T E O F C O M P L I A N C E

COVER PAGE FOR TEST REPORT

UL TEST REPORT AND PROCEDURE

Field Certification Certificate of Compliance

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

File S789 Project 04ME December 20, 2005 REPORT CONTROL UNIT (UOJZ) * * * * * * * * * * * * * * * * * * * * *

File E Project 97SC January 21, 1998 REPORT

EU Declaration of Conformity

Xiamen Comfort Science & Technology Group Co., Ltd 18 Long Shan South Road, Xiamen, Fujian Province, , China

Declaration of Conformity

Performer Cuspidor. Installation Instructions. (For Performer III Chair & International Performer I Chair) You Will Need. About This Install

UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

EU Declaration of Conformity

Listing Constructional Data Report (CDR)

CLASSIFICATION Constructional Data Report (CDR)

Certification Supplement Manual

Certification Supplement Manual

SPECIFICATION FOR APPROVAL

File E Project 08ME October 7, 2008 REPORT. UNLISTED COMPONENT - Attachment Plugs, Fuseless. For Use Only In

Certificate of Compliance

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

Listing Constructional Data Report (CDR)

SPECIFICATION FOR APPROVAL

This is a preview - click here to buy the full publication

INTERNATIONAL STANDARD

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

Test Report issued under the responsibility of:

This is a preview - click here to buy the full publication

Motogard. Over Temperature Protection System. Installation Instructions

SECTION LOW VOLTAGE LIGHTING CONTROLS

IECEE OPERATIONAL DOCUMENT

RECOGNIZED COMPONENT Constructional Data Report (CDR)

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

TECHNICAL REPORT IEC TR General testing procedures for medical electrical equipment. Edition

Certificate of Compliance

Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees

Part 2-55: Medical electrical equipment. Particular requirements for the basic safety and essential performance of respiratory gas monitors

ISO INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Certificate of Compliance

INTERNATIONAL STANDARD

Descriptive Report and Test Results

HARMONY LED385 EXAMINATION LIGHTING SYSTEM

ISO INTERNATIONAL STANDARD

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Demystifying Power Tap Use in Healthcare Settings John Garbarino Sr. Marketing Manager, Commercial/Industrial Leviton Manufacturing Co.

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

HISTORICAL OF SAMPLE RECEIVED EXAMINED SECTIONS

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

Regulatory Information and Specifications

Datasheet - MZM 100 ST-SD2PREM-A

Dissolved Oxygen Analyzers

Certificate of Compliance

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

SpotOn Temperature Monitoring System. SpotOn. Temperature Monitoring System. Model 370 Installation and Service Manual

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. BU-110 and BV-110 Loop Based Displays

INTERNATIONAL STANDARD

DETECT-A-FIRE Heat Detectors

Power Supply Display Module PSDM. Installation and Operation Manual

Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees

INTERNATIONAL STANDARD

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Australian/New Zealand Standard

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

Earth-Rite II PLUS Static Earthing System

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

Certificate of Compliance

INTERNATIONAL STANDARD

Jan05 Rev A EC

SECTION ISOLATED POWER SYSTEMS

INTERNATIONAL STANDARD

Datasheet - MZM 100 ST2-1P2PWREM-A

INTERNATIONAL STANDARD

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

ISIS SAFETY SYSTEM Installation guide

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

SOUTH AFRICAN NATIONAL STANDARD

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion

ORDINANCE NO

SOUTH AFRICAN NATIONAL STANDARD

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

File Ex643 Project 03NK31930 Project 04NK24425 Project 05NK25712 Project 06NK15719 Project 06NK06003 Project 06NK24531

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

Certificate of Compliance

Test Report. Appliance EMF Testing

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

BC3250. Blowdown Controller

Transcription:

Issue Date: 20110304 Page 1 of 12 Report Reference # E302267A32UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: UL 606011, 1st Edition, 20060426 (Medical Electrical Equipment, Part 1: General Requirements for Safety) CAN/CSAC22.2 No. 601.1M90, 2005 (Medical Electrical Equipment Part 1: General Requirements for Safety) Component Recognition QQHM2, QQHM8 (Power Supplies, Medical and Dental) ACDC Adaptor BP(a)040(b)(c)(d)(e) (a) can be A to Z for family related designs. (b) can be S for single. (c) can be 05, 09, 12, 15, 18, 24 or 48 for output voltage. (d) can be F or N or Q for input plug type. (e) can be 00 thru 99 for customer options, not related safety concerns. (a)enb1040(b)(c)(d)(e)(f) (a) can be A to Z for family related designs. (b) can be A to Z for design revision changes. (c) can be 05, 09, 12, 15, 18, 24 or 48 for output voltage. (d) can be 00 thru 99 for standard output cord options. (e) can be F or N or Q for input plug type. (f) can be 00 thru 99 for customer options, not related safety concerns. Rating: Rated Input; 100240Vac, 5060Hz, 1.2 A. Rated Output; 5Vdc, 5.0A or 9Vdc, 4.0A or 12Vdc, 3.4A or 15Vdc, 2.7A or 18Vdc, 2.2A or 24Vdc, 1.7A or 48Vdc, 0.83A. Rated output voltage is designated in the model name designation system). Applicant Name and Address: BRIDGEPOWER CORP 964 GOSAEKDONG GWONSEONGU SUWONSI GYEONGGIDO 441813 KOREA This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for FollowUp Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance with the FollowUp Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's FollowUp Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. Copyright 2011

Issue Date: 20110304 Page 2 of 12 Report Reference # E302267A32UL Prepared by: Reviewed by: KiSoo Ahn Underwriters Laboratories Inc. KiSoo Ahn Underwriters Laboratories Inc. Copyright 2011

Issue Date: 20110304 Page 3 of 12 Report Reference # E302267A32UL Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.

Issue Date: 20110304 Page 4 of 12 Report Reference # E302267A32UL Product Description Switching type power supply, which electronic components are mounted on PWB and housed in plastic enclosure and provided with appliance inlet. In addition, some series of power supply are the direct plugin units. See "model differences" Model Differences The BPM040 series is the basic model. Model (a)enb1040 series is identical to the basic model series except for the model type designations. The marked models as 05, 09, 12, 15, 18, 24 and 48 on nomenclature are similar, except for Main transformer (T1) windings, output rating and minor secondary circuit options not affecting safety. For each plugtype configuration FClass I appliance inlet type: IEC60320C14, QClass II appliance inlet type: IEC60320C18, NClass II appliance inlet type: IEC60320C8. Technical Considerations Classification of installation and use : Portable Supply connection : Appliance Inlet Accessories and detachable parts included in the evaluation : None Options included : None The product was investigated to the following additional standards:: EN 606011: 1990 + A1:1993 + A2:1995 The product was not investigated to the following standards or clauses:: Clause 36, Electromagnetic Compatibility (IEC 6060112), Clause 48, Biocompatibility (ISO 109931), Clause 52.1, Programmable Electronic Systems (IEC 6060114) The product is Classified only to the following hazards:: Casualty, Fire, Shock The degree of protection against harmful ingress of water is:: Ordinary The mode of operation is:: Continuous Software is relied upon for meeting safety requirements related to mechanical, fire and shock:: No The product is suitable for use in the presence of a flammable anesthetics mixture with air or oxygen or with nitrous oxide:: No Engineering Conditions of Acceptability

Issue Date: 20110304 Page 5 of 12 Report Reference # E302267A32UL For use only in or with complete where the acceptability of the combination is determined by Underwriters Laboratories Inc. When installed in an endproduct, consideration must be given to the following: Unit has not been evaluated for use in or likely to be used in the patient vicinity. Instructions shall be considered in the end product application. Marking shall be considered in the end product application. Leakage current measurements shall be considered in the enduse product. Unit was evaluated for use in a 40 C ambient. Additional Information Max. Normal Load Condition: Rated output current Markings and instructions Clause Title Marking or Instruction Details Company identification Classified or Recognized company's name, Trade name, Trademark or File Model Model number Supply Connection Voltage range, ac/dc, phases if more than single phase Alternating current Supply Frequency Power Input Class II Rated frequency range in hertz Amps, VA, or Watts Output Rated output voltage, power, frequency. Attention, consult accompanying documents Special Instructions to UL Representative Samples specified as below shall be selected from current production or stock for the tests indicated. Product Name: BPMseries and MENB series, CCL Item: Transformer (T1), Dielectric Voltage Withstand: Primary lead to secondary lead with 4000 V ac for 1 min.

Issue Date: 20110304 Page 6 of 12 Report Reference # E302267A32UL ProductionLine Testing Requirements Test Exemptions The following models are exempt from the indicated test Model Grounding Continuity Dielectric Voltage Withstand Patient Circuit Dielectric Voltage Withstand All models Not Exempt Not Exempt Exempt SolidState Component Test Exemptions The following solidstate components may be disconnected from the remainder of the circuitry during either Dielectric Voltage Withstand Test: N/A Sample and Test Specifics for FollowUp Tests at UL The following tests shall be conducted in accordance with the Generic Inspection Instructions Model Samples Test Test Details N/A N/A N/A N/A

Issue Date: 20110304 Page 7 of 12 Report Reference # E302267A32UL TABLE: List of Critical Components Object/part or Description Manufacturer/ trademark type/model technical data CCN Marks of Conformity Appliance Inlet (Class I) Rong Feng Industrial Co., Ltd. SS120 Rated 15 A / 250 V. AXUT2/8 Appliance Inlet (Class II) Rong Feng Industrial Co., Ltd. RF180 Rated 2.5 A / 250 V. AXUT2/9 Appliance Inlet (Class II) Alternate Rong Feng Industrial Co., Ltd. SS120A Rated 15 A / 250 V. AXUT2/8 Enclosure(Fire/Mech./El ec.) CHEIL INDUSTRIES. HN1064W(+) Overall Sized approx. 102.0 by 60.0 by 32.5mm. Min 2.0mm thickness, V1, RTI 80 degree C. Composed of two pieces, secured together by ultrasonic welding. QMFZ2/8 Fuse (F1) Save fusetech Inc SS5 Rated 250V, T3.15AL JDYX2/8 Fuse (F1) LITTELFUSE 392 Rated 250V, T3.15AL JDYX2/8 Alternate WICKMANN WERKE Fuse (F1) Hollyland co., ltd. 5ET Rated 250V, T3.15AL JDYX2/8 Alternate Fuse (F1) NIPPON SEISEN SLT Rated 250V, T3.15AL JDYX2/8 Alternate CABLE, LTD. Fuse (F2) Save fusetech Inc SS5 Rated 250V, T3.15AL JDYX2/8 Fuse (F2) LITTELFUSE 392 Rated 250V, T3.15AL JDYX2/8 Alternate WICKMANN WERKE Fuse (F2) Hollyland co., ltd. 5ET Rated 250V, T3.15AL JDYX2/8 Alternate Fuse (F2) NIPPON SEISEN SLT Rated 250V, T3.15AL JDYX2/8 Alternate CABLE, LTD. Varistor (ZNR4) Success Electronics SVR14D471K Rated 470 V, (linetoline), Overall dimension 14 VZCA2/8 (Optional) mm. Varistor (ZNR4) AMOTECH CO LTD INR14D471 Rated 470 V, (linetoline), Overall dimension 14 VZCA2 (Optional) Alternate mm. Varistor (ZNR4) (Optional) Alternate HONGZHI ENTERPRISES LTD HEL14D471K Rated 470 V, (linetoline), Overall dimension 14 mm. VZCA2

Issue Date: 20110304 Page 8 of 12 Report Reference # E302267A32UL Object/part or Description Manufacturer/ trademark type/model technical data CCN Marks of Conformity Thermistor (TH1) Various Various NTC, 5 ohm or 10 ohm at 25 degree C Line Filter (LF1) 3025634 Core: Ferrite, Coils: Polyurethane Enamelled Wire Min.130degree C. Bobbin: (QMFZ2) Bakelite, type PM9820@, V0, 150 deg C Xcapacitor (CX1) (Line Carli MPX Rated 250V, Max.. 0.47 uf. Marked with X1 or X2. FOWX2 to Line) Meets IEC/EN6038414. Xcapacitor (CX1) (Line Iskra KNB 1530 or Rated 250V, Max.. 0.47 uf. Marked with X1 or X2. FOWX2 to Line) Alternate 1562 or 1563 Meets IEC/EN6038414. Xcapacitor (CX1) (Line Pilkor PCX2 335M or Rated 250V, Max.. 0.47 uf. Marked with X1 or X2. FOWX2 to Line) Alternate PCX2 337 Meets IEC/EN6038414. Xcapacitor (CX1) (Line Okaya LE Rated 250V, Max.. 0.47 uf. Marked with X1 or X2. FOWX2 to Line) Alternate Meets IEC/EN6038414. Xcapacitor (CX1) (Line Sunil 436D Rated 250V, Max.. 0.47 uf. Marked with X1 or X2. FOWX2 to Line) Alternate Meets IEC/EN6038414. Xcapacitor (CX1) (Line Tenta MEX Rated 250V, Max.. 0.47 uf. Marked with X1 or X2. FOWX2 to Line) Alternate Meets IEC/EN6038414. BridgeDiode(BD1) Various Various Min. 4.0A, Min. 600V. Discharging Resister Various Various 510Kohm 1/8W (PR1, PR2) Electrolytic Capacitor Various Various Max. 82 uf, Min. 400 V, min. 105 degree. (C1) Switching IC (U1) Various Various Max 30V, Max.4mA FET (Q1) Various Various Min 650V, Max.7.2A for output 5 V 3025688001 JEC(B), Class B. Core: Ferrite, size 28 by 20 mm. C.Bobbin:(QMFZ2), V0, 130 degc. see Enclosure

Issue Date: 20110304 Page 9 of 12 Report Reference # E302267A32UL Object/part or Description for output 9V for output 12 V for output 15V for output 18 V for output 24 V for output 48 V Optical Isolator (U2) Optical isolator (U2) Alternate Optical isolator (U2) Alternate Manufacturer/ trademark Vishay Semiconductor COSMO ELECTRONICS CORP SHARP CORP ELECTRONIC COMPONENTS type/model technical data CCN Marks of Conformity 3025688002 JEC(B), Class B. Core: Ferrite, size 28 by 20 mm. C.Bobbin:(QMFZ2), V0, 130 degc. see Enclosure 3025688003 JEC(B), Class B. Core: Ferrite, size 28 by 20 mm. C.Bobbin:(QMFZ2), V0, 130 degc. see Enclosure 3025688004 JEC(B), Class B. Core: Ferrite, size 28 by 20 mm. C.Bobbin:(QMFZ2), V0, 130 degc. see Enclosure 3025688005 JEC(B), Class B. Core: Ferrite, size 28 by 20 mm. C.Bobbin:(QMFZ2), V0, 130 degc. see Enclosure 3025688006 JEC(B), Class B. Core: Ferrite, size 28 by 20 mm. C.Bobbin:(QMFZ2), V0, 130 degc. see Enclosure 3025688007 JEC(B), Class B. Core: Ferrite, size 28 by 20 mm. C.Bobbin:(QMFZ2), V0, 130 degc. see Enclosure TCET1103(G)D or Double protection optical isolator. Providing TCET1103 KP1010X PC123 isolation voltage 5000 Vac Double protection optical isolator. Providing isolation voltage 5000 Vac Double protection optical isolator. Providing isolation voltage 5000 Vac FPQU2/8 FPQU2/8 FPQU2 US

Issue Date: 20110304 Page 10 of 12 Report Reference # E302267A32UL Object/part or Description Manufacturer/ trademark type/model technical data CCN Marks of Conformity GROUP Optical isolator (U2) LITEON LTV817 Double protection optical isolator. Providing FPQU2/8 Alternat TECHNOLOGY CORP isolation voltage 5000 Vac Optical isolator (U2) Alternate KODENSHI KOREA PC17K Double protection optical isolator. Providing isolation voltage 5000 Vac. FPQU2/8 Bridging Capacitor (CY1, SUCCESS SE & CB 250Vmin, 1000 pf. Marked with Y1 & Y2. FOWX2 CY2) ELECTRONICS CO LTD PWB Various Various Min. V1, min 130 C. ZPMV2 Heatsink(HS1)Primary Various Various Metal, overall sized approx. 54 by 22 mm, 2 mm thickness. Wound by polyester film tape OANZ2), Min. 130 deg C, Heatsink(HS2) Secondary Various Various Metal, overall sized approx. 35 by 22 mm, 2 mm thickness. Wound by polyester film tape OANZ2), Min. 130 deg C, Output cable(lps) Various Various For use of external interconnection, max 3.05 m long, max. 300 V, 80 C, min.20 AWG, Marked with VW1 or FT1. Nameplate Label BETHEL BG1000 Suitable for use on surface of Polycarbonate (PC) with max. 60 C surface temperature. Bonding Glue Various Various Min. V2, min. 100 C for additional secureness of internal conductor. Wiring, internal (Primary) Various Various Max. 300 V, 80 C, min.20 AWG, Marked with VW 1 or FT1. Bonding conductor Various Various Mechanically clamped or secured on PWB from Appliance Inlet. Min 18 AWG, GreenandYellow Insulation. AVLV2 or ZJCZ PGDQ2, PGAA QMFZ2 AVLV2 AVLV2

Issue Date: 20110304 Page 11 of 12 Report Reference # E302267A32UL

Issue Date: 20110304 Page 12 of 12 Report Reference # E302267A32UL Enclosures Type Supplement Id Description Collateral Particular Photographs 345 External view of FClass I appliance inlet type: IEC60320C14. Photographs 346 External view of NClass II appliance inlet type: IEC60320C8. Photographs 347 External view of QClass II appliance inlet type: IEC60320C18. Diagrams Schematics + PWB 506 Circuit Diagram Schematics + PWB 507 PWB Pattern Manuals Miscellaneous 702 T1 transformer Spec(For 5Vdc output) Miscellaneous 709 T1 transformer Spec(For 9Vdc output) Miscellaneous 710 T1 transformer Spec(For 12Vdc output) Miscellaneous 711 T1 transformer Spec(For 15Vdc output) Miscellaneous 712 T1 transformer Spec(For 18Vdc output) Miscellaneous 713 T1 transformer Spec(For 24Vdc output) Miscellaneous 714 T1 transformer Spec(For 48Vdc output) Miscellaneous 716 Enclosure drawing Miscellaneous 734 Marking plate