Arteor TM LCS2 Cat. 6A STP RJ 45 socket

Similar documents
Arteor TM LCS2 Cat. 6A UTP RJ 45 socket

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

LCS 2 THE CATEGORY 6A GUARANTEE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

CATEGORY 6A FTP RJ45 SOLUTION

Compact Module. Category 6A FTP Cabling System 1.1

Multi-Core Fire Resistant Cable

Cat 6 Unshielded Patch cords

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

LCS 2 YOUR digital infrastructure

/Oct/2014 Rev E

INTERNATIONAL STANDARD

/Oct/2014 Rev B

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

FEB. 17 Rev. A1

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description

Cat 6 Shielded Patch cords

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

PRODUCT CATALOGUE Norröna

Sonos-SB Siren/Beacon

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Mar11 Rev B

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Battery Interconnects

IP Access FACP Adapters. Installation Guide. Entrada2DMK - IP Access FACP Adapter Kit. Kit Includes: Entrada2DMR - IP Access FACP Receiver

The Next Generation of Data Communicatons Solutions

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

Around the cable. Pressing and crimping.... convincing solutions

Type MTS Miniature Test Switches

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

4-Channel Contact Closure Fiber Link Card System

Introduction. Technical Features

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Call stations and extensions

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

D45. High performance door entry system CATALOGUE. A Group Brand

simply fits your needs

Caledonian Flame Retardant Coaxial Cables

INTERNATIONAL STANDARD

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Qualification Test Report 1/Jul/2005 Rev. A

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Control and Indicating Equipment

C-Bus Four Channel Analogue Output Unit Installation Instructions

FIRE RESISTANT CABLES

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

A. The requirements of this Section and the other Division 26, 27 & 28 Sections apply to all the video surveillance system work.

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Special Provision No. 683S28 December 2017

CABLES FOR ALARM AND SAFETY SYSTEMS

Industrial Ethernet Circular Sealed RJ-45 Connectors

Z-PACK TinMan 85 ohm Connector Overview

Industrial Ethernet Products. RoHS. Ready

This document is a preview generated by EVS

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus

Introducing Hermaphroditic Blade and Receptacle Connector

Contents. 30 References

EASY-WAVE Trash & Linen Chute System Installation

PROJECT DATE FLANGE FINISH

Telephone and Data Structured Wiring

INTERNATIONAL STANDARD

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

Universal Connectivity Platform A Modular Approach to Infrastructure Design

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

Fibre Specification Standards

Product Specification Qualification Test Report

Instruction Manual SCD24. Read this document prior to installation. Contents

C-Bus Four Channel General Input Unit Installation Instructions

Flame Retardant Overall Screened Instrumentation Cables (multicore)

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

INTERNATIONAL STANDARD

Index D45 D45. system. Catalogue. System overview 4 Entrance panel overview 6 Internal unit overview 7

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

Switches compliant with ATEX directive

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

PRESENTING OUR NEW RANGE FROM PLATINUM TOOLS

4 Channel Contact Closure SFP DIN Fiber Link System

This document is a preview generated by EVS

4120 Fire Alarm Network Reference

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

Comtran Cable. Hub-LINK Cables for Transit Applications

EXECUTING HIGHLY ACCURATE FIBER MEASUREMENTS IN A FRACTION OF THE TIME

Architectural and Engineering Specification for a. Flash / Flare

Ericsson RBS Commissioning. Version: 01. Guide 1/16

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

VPS3 Installation Manual

SA-3841 User Manuel. 1U 4 Fans Unit with Thermostat Sensor. Version 1.1 Copyright All Rights Reserved

Transcription:

87045 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Arteor TM Page 5 723 06 5 723 50 1. General characteristics....1 2. Presentation...1 3. Real life scenarios...1 4. Technical characteristics...2 5. Connection...2 6. Overall dimensions....2 7. Usual connection of RJ 45 sockets...2 8. Standards and approvals...3 9. Performance.... 3-6 1. GENERAL CHARACTERISTICS Cat. 6A RJ 45 terminal socket for high speed connection to a network. Enables data transmission at 10 Gbit/s. Socket is used with Cat. 6A F/UTP or S/FTP cables. Colour code and Contact number Identification number STP : SA63 1 2 2. PRESENTATION Désignation Nbre de modules STP white magnesium 1 1 5 723 06 5 734 32 5 728 06 5 737 32 RJ 45 safety socket Cat. 6A STP white 2 5 723 50 Category colour code: Cat. 6A yellow RJ 45 safety socket Cat. 6A STP magnesium white orange cover 2 5 728 50 1 5 723 51 3. real life scenarios Mechanisms can be flush-mounted or surface-mounted. * white green cover 1 5 723 52 * magnesium orange cover 1 5 728 51 magnesium green cover 1 5 728 52 * * not supplied with the mechanism Unlocking Technical data sheet: F01496EN/00 Updated : Created: 10/04/12 1/6

4. TECHNICAL CHARACTERISTICS 4.1 Material characteristics Contacts: gold/nickel, minimum thickness of gold > 0.8 µm Metal parts: bronze, nickel, platinum, gold PBT polycarbonate For STP products the body and the spreader are made of metal alloy with a copper-nickel coating. 4.2 Electrical characteristics Breakdown voltage 1000 V Contact resistance m Insulation resistance 500 M at 100 V DC Connector tested and guaranteed under PoE restrictions, IEEE 2.3af standard and PoE+, draft standard 2.3at, up to 2500 on-load connections / disconnections. Tests are carried out with 2 simultaneous PoE+ circuits for a minimum total power of 50 W. 4.3 Mechanical characteristics Max. number of connections and disconnections: 5 without refreshing the wiring. Endurance: 2500 movements (plug insertion/withdrawal) IK03 4.4 Climatic characteristics Operating temperature: - C to + 70 C Humid heat cycle 21 days 6. OVERALL DIMENSIONS (cont.) Side view: 5 723 06-5 734 32 5 728 06-5 737 32-5 723 51/52 31 7. USUAL CONNECTION OF RJ 45 Accepts the following cable connectors: RJ11 (4 contacts), RJ12 (6 contacts), RJ45 (9 contacts). Double colour code EIA TIA 568 A and B on terminals: - STP 9 contacts 3 screen 5. CONNECTION L1 L3 EIA 568 A EIA 568 B L2 L1 90 m L2 5 m L3 5 m Conductors supported: - Single-wire: 0.5 to 0.65 mm, AWG 22 to 25 - Multiple-wire: AWG 26 - Polyethylene conductor insulation: max Ø with insulation 1.58 mm. RJ 45 connectors are equipped with a locking nut that does not require the use of a specific tool and which enables re-cabling in the event of error. 6. OVERALL DIMENSIONS Front view: 1 2 5 723 50-5 728 50 5 723 06-5 734 32-5 728 06 5 737 32-5 723 51/52-5 728 51/52 45 45 45 22,5 Technical data sheet: F01496EN/00 Updated : Created : 10/04/12 2/6

7. USUAL CONNECTION OF RJ 45 (cont.) This system allows the wire pairs to be spread easily before mounting them on the connector. 4 9. PERFORMANCE 9.1 Performance of permanent link with F/UTP cable Return loss 3 OK 10 5 Attenuation Spreading cables ensures that each pair is separated by the specified 13 mm. Spreading pairs by 90 in relation to the cable ensures optimum performance. 8. STANDARDS AND APPROVALS Compliant with standards: ISO 111 Second edition EN 50173 Second edition EIA/TIA-568-B.2 NF C 730 Standard 8877-3.7 10 NEXT (Near end Crosstalk Attenuation) 10 1 MHz 500 Mz Technical data sheet: F01496EN/00 Updated : Created : 10/04/12 3/6

9.1 Performance of permanent link with F/UTP cable (cont.) PS NEXT (Power Sum NEXT) 9.1 Performance of permanent link with F/UTP cable (cont.) Delay skew 0 ns 10 ACR-N (Attenuation to Crosstalk Ratio) 100 ns 9.2 Performance of permanent link with S/FTP cable Return loss 10 10 ACR-F (Equal Level End Crosstalk Attenuation) Attenuation 10 10 Technical data sheet: F01496EN/00 Updated : Created : 10/04/12 4/6

9.2 Performance of permanent link with S/FTP cable (cont.) NEXT (Near end Crosstalk Attenuation) 9.2 Performance of permanent link with S/FTP cable (cont. ACR-F (Equal Level End Crosstalk Attenuation) 10 PS NEXT (Power Sum NEXT) 10 Delay skew 0 ns 10 100 ns ACR-N (Attenuation to Crosstalk Ratio) - db 9.3 Performances canal (Channel) Return loss 0 db 10 Technical data sheet: F01496EN/00 Updated : Created : 10/04/12 5/6

9.3 Channel performance (cont.) Attenuation 9.3 Performances canal (Channel) (cont.) ACR-N (Attenuation to Crosstalk Ratio) - db 0 10 db NEXT (Near end Crosstalk Attenuation) ACR-F (Equal Level End Crosstalk Attenuation) 10 10 PS NEXT (Power Sum NEXT) Delay skew 0 ns 10 100 ns Technical data sheet: F01496EN/00 Updated : Created : 10/04/12 6/6